Loading...
HomeMy WebLinkAboutAPPROVED Updated roofing permit information sheet.pdfLl1LlL - C L ST. LUCIE ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1 g,4,5,8,7 Concrete or Clay Tile A, 8, D, E 1,2,3,4,5,807 Metal Roofs A, B, D Wood Shingles and A, B, D Shakes Other As Applicable 1,2,4,6,6,7 1,2,3,4,8,6,7 ATTACHMENTS REQUIRED As Applicable): 1. 1 Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. 1 Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. 1 Other Component of Product Approval 1 5. 1 Municipal Permit Application 1 6. 1 Owners Notification for Roofing Considerations (Reroofing Only) 7. I Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE Master Permit No. 2104-0227 Contractors Name: Alliance Group Job Address 6008 Raintree Trail Section A (General Information) Process No. License # CCC 1330918 ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles ® Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ New roof ❑ Repair Low Slope Roof Area (SF) ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ Maintenance M Reroofing ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 2,538 ❑ Recovering Total (SF) 2,538 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. SEE ATTACHED ROOF SKETCH mom NEI 1-00M�W111111111 ME In 0 MEN "ON ST. LUCIE NORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: _ Zone 2: _Zone 3: _ Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_" oc @ Lap, # Rows— 0.00 Zone 1—" oc @ Lap, # Rows — ® — ao Zone 2:—" oc @ Lap, # Rows — ® — oo Zone 3—" oc @ Lap, # Rows— ® _ oc Number of Fasteners Per Insulation Board: Zone 1':—Zone 14Zone 2:—Zone 3* Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. ST. LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer Metal Alliance Notice of Acceptance Number: FL31652-R1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1*32.3zone 2e732-kone 2n!'51 •� one 2r:"51 •Zone 3e: -51-gone 3r: -55•7 Deck Type: Plywood C DX 112" Type Underlayment: Tribuilt HT Smooth self -adhered Roof Slope: 5____ 12 Insulation: NIA Fire Barrier: NIA Rida7,AVentilation? Fastener Type & Spacing: N/A lM Adhesive Tyne: NIA MeanRoof Height: 10 1 Type Cap Sheet NIA Roof Covering: 26-gauge 5-V Type & Size Drip 6-gauge 3x3 Edge: ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: -x,l-= )- mg: -=Me- Product Approval M, (Zone 2e: -xx-= I- Mg: _=M2 _ Product Approval Mr (Zone 2n: -xa-=-Mg: -=Mm- Product Approval Mr (Zone 2r: -x1t_= _)-Mg:-=Mm- Product Approval Mr (Zone 3e: _-xx-= -)-Mg: -=Me.- Product Approval Mi (Zone 3r: _ x )L-= -) - M9: -_ Mm- Product Approval Mr Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf M, required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 4iY 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30A 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 1 24.4 1 25.9 1 27.1 28.2 30.0 *Must be used In conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Fn Product Approval F' (Zone 2e: x L_=x W:=) -W: cos r =F,u_ Product Approval F'. (Zone 2n: x L=x W:=) -W: cos r =F,2n_ Product Approval F', (Zone 2r: x L_=x W:= ) -W: cos r =Fr2,_ Product Approval F', (Zone 3e: x L=x W:=) -W: cos r =F,u_ Product Approval F', (Zone 3r: x L= x W ) -W: cos r =Frsr_ Product Approval F', Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope B Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Ms Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L= length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.