Loading...
HomeMy WebLinkAboutNOA; Series HR120-Sentinel Aluminium Horizontal Sliding WindowMIAWDADE DEPARTMENT OF REGULA BOARD AND CODE ADMINI NOTICE OF ACCE CGI.WINDOWS and DOOR 3780 W.104'h Street Hialeah, FL_ 33018 SCOPE: This NOA is being issued uni materials. The documentation Product Control Section to be i Having Jurisdiction (AHJ). This NOA shall not be valid Control Section (In Miami —Du the right to have this product c fails to perform in the accepted may immediately revoke, mod: RER reserves the right to revok Section that this product or mat This product is approved asdE Code; including the High Veloc DESCRIPTION: Series "HR APPROVAL DOCUMENT: Alum. Horizontal Sliding Wi manufacturer, signed and seale Control Revision stamp with 1 County Product -Control Sectioi MISSILE IMPACT RATIN COO �® P —D COUNTY, FLORIDA 50 PRODUCT CONTROL SECTION 'AND ECONOMIC RESOURCES (RER) 11805_ SW 26 Street, Room 208 TION DIVISION T (786) 315-2590 F (786) 315' 2599 ONCE (NOA) WWW.MiamidadLgov/economy Il LICM the applicable rules and regulations governing the use of construction mitted has been, reviewed and accepted by Miami —Dade County RER— in Miami —Dade County and other areas where allowed by the Authority after the expiration date stated below. The Miami —Dade County Product e County) and/ or the AHJ (in areas other than Miami —Dade County) reserve r material tested for quality assurance purposes. If this product or material manner, the manufacturer will incur the expense of such testing and the AHJ fy, or suspend the use of such product or material within their jurisdiction. this acceptance, if it is determined by Miami —Dade County Product Control trial fails to meet the requirements of the applicable building code. scribed herein and has been designed to comply with the Florida Building ity Hurricane Zone. O-Sentinel" Aluminum Horizontal Sliding Window — L.M.I. .awing No. HR 120LM-NOA Rev A (former W10-18), titled "Series 120 low-LM", 'sheets 1 through 14 of 14, dated 06/03/20, prepared by by Anthony Lynn Miller, P: E., bearing the Miami —Dade County Product Notice of Acceptance number and expiration date by the Miami —Dade Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate.this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion_ of the NOA is displayed, then it shall be done '�n its entirety. INSPECTION: A copy of tl}is entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews! NOA No. 17-0918.09 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation reviewed by Ishaq I. Chanda, P. E. �i,aMNUAae eounrr NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 Page 1 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under�NOA's.No.'s 10-0510.12 and 15-0512.05) 2. Drawing No. W10-18, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw. (L.M.I./ S.M.I.)", sheets I; 1. 1, 2, 2.1, 3, 3.1, 4 through 11 of 11, dated 03/20/10 with revision "G" dated 05/02/I6, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 201-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test, per FBC, TAS 201-94 5) CyclicWind Pressure Loading, per FBC, TAS 203-94 6) .Forced Entry Test, FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a series Sentinel 120 aluminum horizontal sliding wind w, ' prepared by Certified Test Laboratories, Test Report No. CTLA- 3062W, dated 07/07/15, signed and sealed by Ramesh C. Patel, P.E. 2: Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series fixed window, to qualify DuPont `iButacite" PVB interlayer; Duraseal® and Super Spacer(P insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, RE. (Submitted under; previous NOA No. 15-0512:05) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 21 Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer(g insulating glass spacer; prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under previous NOA No. 15-0512.05). 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series aluminum fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA- 3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted unde I previous NOA No. 15-0512.05) Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-1 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 201-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile. Impact Test, "per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 6) Forced Entry Test, FBC 241-1 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram 'of a series "Sentinel" aluminum horizontal sliding window, prepared by Hurricane Test.Laboratory, LLC, Test Report No. HTL-0080-0102-10, dated 06/04/16, signed and sealed by Vinu J. Abraham, P. E. (Submitted under NOA No. 10-0510.12) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5th Edition (2014), prepared by Al-Farooq Corporation, dated 09/17/15 revised on 05/11/16, signed and sealed by Javad Ahmad, P: E. 2. Glazing complies' with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their "Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/18. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP, Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. 4. Notice of Acceptance No. 14-0423.17 issued to ]Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers", expiring on 05/21/16. I F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 511 Edition (2014) and of no financial interest, dated 08/17/15, issued by A1=Farooq Corporation, signed and sealed by Javad Ahmad, P. E. 2. Laboratory compliance letters for Test Report No. CTLA-3062W, dated 07/07/15, issued by Certified Test Laboratories, signed and sealed by Ramesh. C. Patel, P. E. 3. Testing Proposal issued by the Product Control Section, dated 04/08/15, signed by Jaime Gascon, P. E., Section Supervisor. 4. Laboratory compliance letters for Test Reports No.'s CTLA-3056 WA, dated 03/03/15, CTLA-3056 WB; dated 03/03/15 and CTLA-3056 WC, dated 04/16/15, all issued by Certified Test Laboratories, all signed and sealed by Ramesh C. Patel, P. E. (Submitted under previous NOA No. 15-0512.05) lshaq 1. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-2 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS (CONTINUED) 5. Testing Proposal issued by the Product Control Section, dated 12/16/14, signed by Jaime - Gascon, P. E., Section Supervisor. (Submitted under previous NOA No. 15-0512.05) 6. Laboratory compliance letters for Test Report No. HTL-0080-0102-10, issued by Hurricane Test Laboratory, LLC, dated 06/04/10, signed and sealed by Vinu J. Abraham, P. E. (Submitted under NOA No.10-0510.12) G. OTHERS 1. Notice of Acceptance No..15-0512.05, issued to CGI Windows & Doors for their Series "Sentinel 120" Aluminum Horizontal Sliding Window - L.M.I., approved on 08/20/.15 and expiring on 09/22/20. 2. EVIDENCE SUBMITTED UNDER PREVIOUS NOA A. DRAWINGS 1. Drawing No. W10-18, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw. (L.M.I./ S.M.I.)", sheets 1rr 1.1, 2, 2.1- 3, 3.1, 4 through 11 of 11. dated 03/29/10 with revision "H" dated 09/05/1"7, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). i E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated O1/19/17, expiring on 07/08/19. .2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Interlayer" dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP _ Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. Ishaq 1. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-3 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to FBC 51h Edition (2014) and FBC 6th Edition (2017), dated 08/30/17, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P. E. G. OTHERS 1. This NOA revises NOA #15-0929.13, expiring on 09/22/20. 3. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. HR 120LM-NOA Rev A (former W10-18), titled "Series 120 Alum. Horizontal Sliding Window-LM", sheets 1 through 14 of 14, dated 06/03/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E. B. TESTS 1.. Test reports on: 0Air Infiltration Test, per FBC, TAS 202-94 2)� Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3)1 Water Resistance Test, per FBC, TAS 202-94 4)� Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203:-94 6)1 Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all CGI Windows and Doors; Inc. and PGT Industries, Inc., 'epresentative units listed below and tested to qualify Dowsi1791 and Dowsi1983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc.; Test Reports No.: CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI 8H360 Aluminum Single Hung Window (unit .1 in proposal) FTL-10- 2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 m. AluminuFixed Window(unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E. FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/.14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20- 2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT. PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with. FBC 71h Edition (2020), dated 03/26/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing -complies with ASTM E1300-04, -09, -12 and 46. Ishaq'I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-4 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. NEW EVIDENCE Continue: D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/24. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/23. 3. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. 4. Notice of AcceptanceiNo. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflez and Saflex HP Composite Glass Interlayers with PET Core", expiring on 12/11/23.� F. STATEMENTS 1. Statement letters of conformance to FBC 2020(7th Edition), dated 03/26/20, prepared, signed & sealed by Lynn Miller, P. E. 2. Statement from Successor Engineer, adopting another Engineer's work as his own per FLA 51G915.27-001, signed and sealed on 06/03/20 by Anthony Lynn Miller, P.E. 3. Statement of Lab compliance as part of the test report. G. OTHER 1. This NOA revises and renews NOA No. 17-0918.09 and updates to FBC 2020 (7t' Edition) expiring 09/22/25. 2. RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda, P.E. Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020. E-5 FLANGE &FLANGE ADAPTOR FRAME EQUAL LEG FRAME LAMINATED GLASS THESE WINDOWS ARE RATED FOR LARGE INSULATING LAM. GLASS & SMALL MISSILE IMPACT. SHUTTERS ARE LARGE MISSILE IMPACT NOT REQUIRED. SMALL MISSILE IMPACT SERIES `SENTINEL 1200' ALUMINUM HORIZONTAL ROLLER WINDOIP DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEETS 3-6. - APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF H.R./H.R. OR HORIZONTAL ROLLING WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI-DADE COUNTY APPROVED CLIPPED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION)/2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE ANCHORS SHALL BE CORROSION' RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALUC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MELT THE REQUIREMENTS OF THE 2017/2020 FLORIDA BUILDING CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, Le. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL PRODUCT REVISED as.eomplying with the Florida Building Code NOA-No. 20-0610.03 Expiration Date: 09/22/2025 Miami -Dade Product Control ImIREVISED FOR R00RMATT D-ADDED ANCHORJR- 29 o 0 0 m O N C J � 2 � ryk O woa 0 � Z Y Y Z n O Ag �MDIQ Q O pQC m0-,o N 5I v _ •aN z u• UUo ul Qa�2^ Z LL 0 adz z p (/J Z 0 _ rz- Z G O U `� J a l0 T•q G 1 � F¢-• � aiw _odd ¢ � w 0 Sto¢m Z 0 W in J rs� mxS� x 4 w Z z �IJ J O N ®QQ N W tO.X-' 0 = nAl LYNAt �'��•'' 1,1GENSF ����� * No.58705 *� l'1 �EF A LYNN MILLER, P.E. P.E # 58705 FLANGE & FLANGE ADAPTOR FRAME 110" E BUCK WIDTH o 5H7 2" MAX. 13 15 16" 1 � MI'G. STILES HEAD SILL � m E2 r N Y a N= O ax mto w j �; mD m - — FALSE MUNTINS (SURFACE APPLIED) 24 1 2" 49 5/B" OPTIONAL DL OPG. .28" D.L. OPG. VENT WIDTH FIN FRAME 0 IS (St EQUAL LEG FRAME LAMINATED GLASS THESE WINDOWS ARE RATED FOR LARGE INSULATING LAM. GLASS & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. LARGE MISSILE IMPACT' SMAIJ MISSILE IMPACT JELS HS PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0610.03 Expiration Date: 09/22/2025 By' _ I y-i I- Z' :,- MlamHDado Product Control z N 5 Q Q o O w m N Z elp0 K .Z J un+u10 >- u: O >n P N m Orop 'ON 2 LL p w=W O 0M0 �UQ ,<L Z Cc i LL O IL z 0 Z p N iea45 W O O Z J Q m Z ,ty ¢ O alna5 tL m o� Aq g6e N O m J LU Z a= �� - P:N w N U vi2`r ¢ O � ij = aqq �asa0 sauaS )VV LYNIV No. 58705 r L a, •Ft ORTD .••' ;� NAL A LYNN'MILLER, P.E. P.E.# 58705 DESIGN LOAD CAPACITY - PSF (XO OR OX SIZES) FLANGE DIMS. BUCK DDIS. ' Sm. LTG. RAIL I.D. LTG. RAIL CfAS3 TYPES . 'A'k'AI'L 'B'k'Bl' GLASS TYPES . IS, k 'Bl' WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-)- 26-1/2" 37" 53-1/8' 74" 26' 25-1/2' 36" 52-1/8' 73' 1, 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 26-1/2" 37" 53-1/8' 74' 38-3/8' 25-1/2' 35' 52-1/8' 73' 37-3/8' 65.0 65.0 00.0 90.0 65.0 65.0 00.0 90.0 65.0 85.0 80.0 90.0 65.0 85.0 80.0 90.0 26-1/2' 37"_ - 53=1/8' 74' 50-5/8" - 25-1/2' - 36 - 52-1/8' 73' -49-5/8'- 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 85.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 26-1/2" 37" 53-1/8" 74" 83" . 25-1/2' 36' 52-1/8' 1. B2. 85.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 60.2 6D.2 00.0 90.0 (1/2W)- (1/2W) G OPERATING VENTS TO BE,1/2 OF THE WINDOW WIDTH 'XO OR OX' DESIGN LOAD.CAPACITY - PSF (XOX SIMS) FLANGE DIMS. - DUCK DIMS. STD. MM. RAIL. R.D. LTG. RAIL H.D. LTG. RAIL GUM TYPES 'A'YAI'L 'B'k'BI' GLASS TYPES 'B' k 'BI' GG879 TYPES V k 'Cl' WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 55-3/4' 78-15/18" 83-1/2' 26' 54-3/4' 77-15/16" 82-1/2' - 25' 65.0 65.0 80.0 90.0. 65.0 65.0 65.0 65.0 80.0 90.0 65.0 65.0. 65.0 65.0 80.0 90.0 65.0 65.0 55-3/4' 78-15/16' 83-1/2' 38-3/8" 54-3/4' 77-15/15' 82-1/2' 37-3/B' 85.0 65.0 80.0 90.0 1 65.0 65.0 65.0 65.0 60.0 90.0 85.0, 65.0 65.0 65.0 80.0 90.0 65.0 85.D 55-3/4' 78-15/16' 83-1/2' 50-5/8 54-3/4' 77-15/16' 82-1/2' 49-5/8' 65.0 65.0 80.0 90.0 65.0 65.0 - - - 65.0 65.0 - - - - 65.0 65.0 55-3/4' 76-15/16' 83-1/2' 63' 54-3/4' 77-15/16' 82-1/2' fit' 65.0 65.0 00.0 90.0 65.0 85.0 - - - - 85.0 65.0 - - - - 65.0 65.0 (1/3W) (2/3W) G VENTS TO BE 1/3 OF THE WINDOW WIDTH XO OR OX' PRODUCT REVISED as eompyin® with the Florida Building Code Non -No. 20-0623.10 Expiration Date0512712024 MismHDade Product Control S' TYP. BUCK DIMS X! TYP. BUCK DIMS BUCK DIMS 3 FLANGE FRAME EQUAL LEG FRAME FLANGE ADAPTOR FRAME FLANGE DIMS 7 1 FLANGE DIMS E5 E4 E4 STD. MTG. RAIL: H.D. MTG. RAIL: NOTE: GLASS CAPACITIES ON THIS SHEET ARE. BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 FLANGE FRAME FLANGE ADAPTOR FRAME EQUAL LEG FRAME. f�N Y Q W�1 $ o O O Q 2 g 2 ry aI�O � z W Z Zp o Y n F fg N x d0 G OMC . O Z uj (7 w=W� w O 0 UOm K 19 ❑ z X> o 0 Z O m 1ee4 � A J O Z O t N -1 IQ- z 41 �rr oGf N 'j Z O O d z3=N Z C9 ' o ... 0 1) Q o V qu ❑ N x \\\`1111111111///// ON�i`�F No. 58705 J`a 0'.• STATE OF i�C�ss,",<ORIDI`.-' N '.,ONAL'1111111IE A. LYNN MILLER, RE P.F # 58705 DESIGN LOAD CAPACITY - PSF '(ROR SIZES) FLANGE DIMS. BUCK. DIMS. STD. IITG. BAII. MD. IlTO. Ben GGS9 7YPS7 'e'k'e!', CIA.99 7YPB8 'B' k 'Bl•, WIDTH HEIGHT WIDTH HEIGHT FXT.(+) IM.(-) EXL(+) IM.(-) 74' 106-1/4' 111' 28' 73' 105-1/4' 110' 25' B5.0 B5.0 B0.0 90.0 85.0 85.0 80.0 90.0 65.0 65.0 B0.0 80.0 74' 108-1/4' 111' 3H-3/B' 73' 105-1/4' 110' 37-3/B• 85.0 65.0 80.0 9D.0 85.0 85.0 ' 80.0 90.0 85.0 B5.0 80.0 90.0 74' 106-1/4' 111' S0-5/8' 73' 105-1/4' 110' 49-5/B' 85.0 65.0 80.0 90.0 65.0 85.0 80.0 90.0 65.0 65.0 80.0 80.0 74' 108-1/4' 111' 63' 73' 105-1/4' 110' 62' 65.0 65.0 80.0 90.0 81.8 61.6 B0.0 9D.0 80.0 BO.O 80.0 90.0 DESIGN LOAD CAPACITY - PSF ' (XOX SIZES)' FLANGE DIPS. BUCK DIPS. Brn. rrG. Ben nn: MTG. Ben B.n. Y1Yl. Ben GI1S4 TYPls 'e'k'u•, 'B'k'BI' GIe98 SYPffi •B' k 'BI' GTABS TYPB9 'c' s •ct' HEIGHT WIDTH HEIGHT EM.(+) IM.(-) E1Lf.(+)� IM.(-) EM.(+) IM.(-) r106-1/4' 26' 73' 105-1 /4' 110' 2fi' 65.0 65.0 80.0 90.0 65.0 B5.0 65.0 85.0 80.0 90.0 65.0 65.0 65.0 65,0 B0.0 90.0 65,0 85.0 38-3/B' 73' 105-1/4' 110' 37-3/8' 85.0 85,0 80.0 90.0 65.0 B5.0 65.0 85.0 80.0 90.0 85.0 65.0 85.0 85.0 80.0 90.0 65.0 85.0 74' 106-1/4' 111' S0-5/B' 73' 105-1/4' 110' 49-5/B' B5.0 85.0 80.0 90.0 65.0 65.0 - - - - 85.0 fi5.0 - - - - 65.0 85.0 74' 106-1/4' 111' 63' 73' 105-1/4' 110' 62' 65.0 85.0 B0.0 90.0 65.0 65.0 - - - - 85.0 65.0 - - - - 65.0 fi5.0 PRODUCT REVISED as comp)yIng with the Florida Building Code NOA No. 20-0623.10 Expiration DatooS/27/2024 By I M.1 Dade Product Control N - Q - - N ]S�JJ[ nay W O O (1/4W) (1/2W) (1/4W) °�' eo0 x l / z¢ Z 9 0 �' T n uMalO K $�` a mO�o OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH w d w O seta o z O IL XOX' XOX' IL 6 a�z" CD v z_ • 0 laa4g 8 f- A of = ¢ N z H G ul Z W along S w N W Yt� TIP. BUCK DIMS J¢' TlP. BUCK DIM9 BUCK DIMS is o w K W z E S�LLm = a w Lu In o < co �+ FLANGE FRAME EQUAL LEG FRAME FLANGE ADAPTOR FRAME ®5.� N wo x FLANGE DIMS - FLANGE DIMS aDU nsa0 sal�ag pxY LYNN ..GEN,gF * ; N0. 58705 * - FLANGE FRAME - - FLANGE ADAPTOR FRAME �o'•.. 3 OFb ,:4U` NOTE:. F/ORIDL _� E4 E4 GLASS CAPACITIES ON THIS SHEET ARE EQUAL LEG FRAME ;°ssi"•N�'�`' BASED ON ASTM E1300-09 (3 SEC. GUSTS) �,�� �NAL STD. MTG. RAIL: H.D. MTG, RAIL: AND FLORIDA BUILDING COMMISSION A LYNN MILLER, P.E. DECLARATORY STATEMENT DCA05-DEC-219 P.E.N b8705 (1/3W) (1/3W) 1(1/3W) DESIGN LOAD CAPACITY - PSF (XO OR OX SIZES) BUCK DIMS. STD. MTG. RAH. N.D. MTG. RAD. SIM TYM MASS T1110 WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) WT.(-) 25-1/2' 36, 52-1/8' 73' 25, 65.0 65.0 00.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 05.0 65.0 1 80.0 80.0 25-1/2' 38' 52-1/8' 73' 37-3/8' 1 65.0 65.0 80.0 80.0 65.0 65.0 00.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 25-1/2' 36' 52-1/8' 73' 49-5/8' 65.0 65.0 80.0 80.0 65.0 65.Q 80.0 80.0 65.0 85.13 80.0 80.0 65.0 1 65.0 80.0 80.0 25-1/2' 36' 52-1/8' 73' 62, 65.0 _ 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 60.2 60.2 00.0 80.0 (1/2W) (1/2W) G OPERATING VENTS TO BE 1/2 OF THE WINDOW WIDTH 'X0. OR OX' E5 E4 E4 STD MTG. RAIL: H.D. MTG. RAIL: DESIGN LOAD CAPACITY - PSF (XOX SIZES) BUCK DIMS. STD. MM. BAIL H.B. MID. RAIL H.D. MTG. PAM GIA>H TYPES 'A'k'AI'. 'B'k'B1' GII88 TYM 'B' k 'BI' VIA TYP® V k 'Cl' WIDTH HEIGHT EXr.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 54-3/4' 77-15/16' 82-1/2' 25' 65.0 65.0 80.0 80.0. 65.0 65.0 65.0 65.0 00.0 80.0 65.0 65.0 55.0 65.0 80.0 80.0 65.0 65.0 54-3/4' 77-15/16' 82-1/2' 37-3/B' 65.0 65.0 80.0 B0.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 54-3/4' 77-15/16' 82-1/2' 49-5/8' 65A 65.0 80.0 B0.0 65.0 65.0 - - - - 65.0 65.0 - - - - 85.0 85.0 54-3/4' 77-15/16' 82-1/2' 62' 65.0 65.0 ' 80.0 80.0 B5.0 65.0 - - - - 65.0 65.0 - - - - 65.0 65.0 (1/3W) (2/3W) G OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH 'XO OR OX' NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E130ID-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 BUCK DIMS FIN FRAME FIN FRAME PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20.0623.10 Expiration Date05/27/2024 By MIamFDade Product. Control T _ N Q Nnab O Z ry rn o N 0. N a a155 ? � z JY n � g ural0 o - oN mOro y W 13Z I. Z api 0 z � vOi Ieey F N (A Z '2 Z U) w dloa; �$W N .N W Aq �NM O W Z Z E3 0 SooQ=Q >aW j a z to w m 'N wp S \\IIIIIiII!-C" Or 84� * No.58705 0 �6 Z 5 a �O%\'.. STA OF !V�` 77 TONAL TEN A. LYNN MILLER. RE P.E.#68705 DESIGN LOAD CAPACITY - PSF (XOX SIZES) BUCK DIMS. BTD. MTG. RAM H.D. MTG. RAH. CUSS TYPES 'A'A'Al', 'B'4'Bl' . GLASS TYPES IV & 181' WIDTH HEIGHT EKT.(+) INT.(-) EXT.(+) [MT.(-) 73• 105-1/4' 110' 25- 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 73' 105-1/4- 110• 37-3/8• 65.0 65.0 80.0 Bo.O 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 73• 105-1/4• 110• 49-5/6• 65.0 65.0 80.0 80.0 65.0 65.0 80.0 SM0 65.0 65.0 80.0 1 80.0 73' 105-1/4• 110• 62- 65.0 65.0 80.0 80.0 61.6 61.6 80.0 1 80.0 60.0 60.0 Bo.O 80.0 (1/3 (1/3W) (1/3W) OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH 'XOX' ES 411 E4 STD. MTG. RAILD. MTG. RAIL: DESIGN LOAD CAPACITY - PSF (XOX SIZES) BUCK DIMS. STD. MTG. RAM, H.D. MTG. RAH, H.D. MTG. RAIL GLASS TYPES 'AIVAI'. 'B'k'B , GLASS TYPES '!I• t 'Bl' GLASS TYPES 'C' A: 'Cl' WIDTH HEIGHT EXT.(+) INT.(-) EKT.(+) .INL(-) EKL(+) INT.(-) 73' 105-1/4• 110! 25• 65.0 65.0 50.0 90.0 65.0 65.0 65.0 65.0 80.0 00.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 73• 105-1/4' 110• 37-3/8' 85.0 80.0 80.0 65.0 65.0 �±5.0 ,0 85.0 80.0 80.0 65.0 •65.0 85.0 65.0 80.0 50.0 65.0 .65.0 73' 105-1/4- 110• 49-5/8• 65.0 65.0 80.0 80.0 65.0 65.0 - - - - 65.0 65.0 - - - - 65.0 65.0 73' 105-1/4' •110' 62' 95.0 _ 65.0 50.0 80.0 65.0 65.0 - _ _ _ 85.0 85.0 - - - - 65.0 65.0 j(1/4W) (1/2W) (1/4W) OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH 'XOX' NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 BUCK DIMS FIN FRAME FIN FRAME PRODUCT REVISED as complying with the Florida Building Code NOA No. 20-0623.10 Expiration Date06/27/2024 By MIaml-Dade Product Control N Y Q N �aa Q z N N O y O Z K = Y ^ O F fB uma0 O N K Y0 m$LL'g_ �' 3 oN -,ma UUd W Woocc O �o>v Zs S O o. z LD z � 1eey; � Z z z A J 4 v t O vi y pa F- Z in W elvv; W 2 a p 3 14 of j U) e m O: O = a z E3'�� $o3fg Sr o 0 Z) Q Z O w N N o z x LYNA(,,, �•, No.58705 -v d ,o �Q�•,, /,, j0jNA1 i A LYNN MILLER, P.E. P.E.# 58705 .075' Saflex CP With PEr Core .075" Saflex CP With PET Core By 'Eastman Chemical Co: By 'Eastman Chemical Go.' 090" Saflex Clear And Color Glass ¢ .090".. Saflex Clear And Color Glass .075" Saflex CP With PET Core By 'Eastman Chemical Go.' g By 'Eastman Chemical Co. By 'Eastman Chemical Co.' ¢ .09 K S mtryGlas® By 'Kuroray America, Inc.' 090' SentryGloa By 'Kumray America, Inc.' g ¢[ 090' SentryGlos® h1 4 'Kuroray America, Inc.' _ Troaifol PVB 1/8" HEAT _ 090" Troeifol PVB 1/8' HEAT PRODUCT REVISED as complying with the Florida By 'Kuroray Ameica, Inc.' 1 /6' AAVADER STREN'D GLASS By 'Kuroray Ameica, Inc.' STREN'D GLASS Building Coda ANN. GLASS 1/8' HEAT STREN'D GLASS 1/8- HEAT STREN'D GLASS NOA-No. • 20-0623.i0 Expiration Date05/27/2024 SILICONES: SILICONES: SILICONES: Dy Icier GE-1900, DOW 791, g 899, 983, OR 995 i y =` MlADDED GE-1203, DOW 791, 899, 883, OR 995 = GE-1200, DOW 791, SSSnnn � 899983, OR 995 Miami -Dade Product Central BACKBEDDING N TYPES -'JR - 5/29/20 O O Ell EB ES o YYn a POINTS ON LTTES AT 1/4 POINTS ON U1TES AT 1R ON LRtS M7 HAN 36' WWW WIDER THAN 36" WIDER THAN 36' AN 3 w Q Z GLASS TYPE 'A' GLASS TYPE 'B' GLASS TYPE 'C' 5/16" NOMINAL LAM. GLASS 5/18' NOMINAL LAM. GLASS 5/16''NOMINAL LAM. GLASS W . p C 0 (L.M.I & S.M.I.) (L:M.I & S.M.I.) (L.M.I & S.M.I.) °lea -, z y O s N • �>n F uxaa � 2 >Lo aN axe / 1/8' ANN. GLASS .075" Saflex CP With PET Core 1/8- HEAT STREN'D GLASS .075' Saflex CP With PET Core 1/8- HEAT STREWD GLASS cWi o L5 p By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' a' a' Saflex CP With PET Cora z o Z � O 1/4- AIR SPACE 090" Sall" Clear And Color Glow By 'Eastman Chemical Co.' 1/4- AIR SPACE .090' Safex Clear And Color Glass By 'Eastman Chemical Co.' 1/4- AIR SPACE .D75' � g BY Eastman Chemical Co.' v a z 1 /8' ANN. OR � 090' SentryGlas® TEMPERED- GLASS �" By 'Kuraray America, Inc.' 1/8' HEAT STREN'D OR rc 090' SentryGias® � By 'Kuroray America, Inc.' 1/8" HEAT �[ 090' SentryGlas® � BY 'Kuroray America, Inc.'n p _ 1ea4S uJ Z TEMPEREDTEMPERED 090' Trosifol FNB GLASS .090' TrosNol PVB GLASS ` • o �, By 'Kuromy Ameica, Inc.' By 'Kuroray Ameica, Inc.' r"ren t N Z a/%S 1/8" ANN. GLASS 1/8- HEAT SrREN'D GLASS 1/8" HEAT STREMD GLASS 't� a;J a: SILICONES: sg S ❑¢m ro v o O ¢ LU Z SILICONES: u, GE-1200, DOW 791, Z N SILICONES: GE-1200, DOW 791, ? m GE-1200, DOW 791, 1 �" m E = p Z W 899, 9B3, OR 995 M1 899, 903. OR 995 899, 983. OR 995 N Mi M1 \ rj .- z qw_� ® _ o Z PACER XL EDGE SIX XL EDGE SPACER XL EDGE SPACER g o`er' ST. STEEL BY 'CARDINAL! Sr. STEEL BY 'CARDINAL' ST. STEEL BY 'CARDINAL' Lr n 2 CD _ OR C, DURASFAL BY 'QUANEW 04 OR �_DURASEAL BY 'QUANEX' OR 14 DURASEAL BY 'QUANDP °lit •asap sauaS RR `�`�NY LYNN, O OR O OR O OR yW E9 SUPER SPACER BY 'QUANEX' z Ell SUPER SPACER BY 'QUANEX' E9 SUPER SPACER BY 'QUANEX* M7 AT 1/4 POINTS ALL SIZES M7 AT 1/4 POINTS ALL SIZES M7 AT 1/4 POINTS ALL SIZES `� �'t. •' UICENSF'��� i GLASS TYPE 'Al' • 0.70' OVERALL INSUL LAM. GLASS GLASS TYPE 'Bl' 0.70" OVERALL INSUL LAM. GLASS GLASS TYPE 'Cl' 0.70' OVERALL INSUL LAM. GLASS ' * : NO.58705 - (L.M.I & S.M.I.) (L.M.I & S.M.I.) (L.M.I & S.M.I.) 6 3 0 it �O�'.• A OF TONAL I\`` •`• • FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LiTE (CAP) MUST BE TEMPERED. A LYNN MILLER, RE P.E.# 58705 FLANGE & FLANGE ADAPTOR FRAME TYPICAL ANCHORS SEE ELEV. FOR SPACING O O FOR SPACING a d a. TYPICAL ANCHOR: SEE ELEV. INTALLATION DETAILS SHOWN ON PAGES 1PEEPHOLES: 8 & 9 APPLY TO BOTH FLANGE FRAME W1 = 1/4" X 1-112" WEEP SLOT AT 4-118" FROM EACH END WITH PLASTIC COVER. AND FLANGE ADAPTOR FRAMES. W2 = 1/8" X 1/2 WEEP SLOT AT 3-1/8 FROM EACH END. W3 = 1/8" X 1/2" WEEP SLOT AT 3-1/8" FROM EACH END. rMIAMI-DARE COUNTY APPROVED MULLION do MULLION ANCHORS SEE SEPARATE NOA EDGE L- --J ANCHORS TYPICAL ANCHORS y SEE ELEV. ACING FOR SPACING WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING 11//4" DIA. ULTRACON BY 'ELCO(Fu-177 KSI, Fy-155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) TYP, EDGE DISTANCE INTO WOOD STRUCTURE = 1" MIN. THRU 1BY BUCKS INTO CONC. OR CMU OR DIRECTLY INTO CONC. OR CMU 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO CMU (JAMBS) TYP. EDGE DISTANCE INTO CONCRETE AND CMU = 2-1/2" MIN. 1/4" DIA. ULTRACON+ BY 'DEWALT' (Fu-164 KSf, Fy-148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 173/8" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) 1" MIN. EDGE DISTANCE THRU 1 BY BUCKS INTO CONC. OR DIRECTLY INTO CONC. 1" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-3/4" MIN. EDGE DISTANCE THRU 1 BY BUCKS INTO HOLLOW CMU OR DIRECTLY INTO HOLLOW CMU 1-1/4" MIN. EMBED INTO CMU (JAMBS) 1-1/2" MIN. EDGE DISTANCE #14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO MIAMI—DADE COUNTY APPROVED MULLIONS (MIN. THK.=1/8") OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM : 1/8" THK. MIN. (6063—T5 MIN.) STEEL : 1/15" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD, SILL OR JAMBS SG - 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. C-90 HOLLOW/FILLED NORMAL WEIGHT BLOCK AT JAMBS f'm = 20GO PSI MIN. PRODUCT REVISED • as complying with the Florida building Code ND=. 20-0623.10 Expiration Onte05/27/2024 NIIamFDade Product Control ADDED ANCHOR TYPE & REFORMATTED -JR- °„ 5/29/20 z N Y Q rn Ba Q z a: N g ai°O > � F "zo Of o 03 0 m Z� 'N JMO wUUd 0 m � w wo�� $ O n�z 0 z O CO � m IBB4$ Z A o z N t z 0 loa$ N 0 cr ti ow w L0" 0' FQ-. Z z z _ w ® �3=� ¢ tw7 .o N_ U'ng� N Qz 1 fY Bill '�6BQ 6Bfla$ 111ll I11!1111, "LYNN �GENSF _ No. 58705 ` - �O� •., STATE OF (441 TONAL N •`• l A LYNN MILLER, P.E P.E.it 58705 FLANGE & FLANGE ADAPTOR FRAME SHIMS / BUCK WIDTHWIDTHSHIMS INTALLATION DETAILS SHOWN' ON, PAGES 8 SHIMS VENT WIDTH VENT WIDTH AND 9 APPLY TO BOTH FLANGE FRAME AND TYPICAL ANCHORS FLANGE ADAPTOR FRAMES. SEE ELEV. FOR SPACING O O O PRODUCT REVISED • as complying with the Florida a ' 1 1/2' Building Code ` NOA-No. 20-0623.10 • Expiration Dat905127/2024 80 By "7 1f FLANGE ADAPTOR FRAME Miami -Dade Product Control 1 1�4•' A2BY WOOD o ' W N SCREENS OPTIONAL BUCK OR 1/2' TYP. WOOD STRUCTURE 1BY WOOD BUCKS D.L. OPG. EXTERIOR 1-1-2 CHORS ELEV. FOR SPACING -- - - - - - - - E ' N Y Q MIAMI-OADE COUNTY APPROVED MULLION de MULUON ANCHORS SEE SEPARATE NOA Q BUCK WIDTH O ALTERNATE p 0 Z BUCK WIDTH ' SWEEP LACK z o SS u,na0 1 OPTIONAL TO 1 SPRING LOCK - z } F aOm Qa SB a m0�o N 2 LL. $ 7 oN SM0 Cl UWd OO Z lug W a:O � ILL Z y m TYPICAL ANCHORS E4 EXTERIOR E3 m c = ¢ z z SEE ELEV. FOR SPACING y vi Z eloas g 1/4• MAK. BUCK WIDTH 1/4• MAX. o CIV W Q Z SHIM 1 VENT WIDTH SHIMS a c ro E - Ln ��� _ Z U, _3 W _v) ANTYPICAL CHORS 1 QII O F G TYPICAL ANCHORS z 7q� ® o. 6N o SEE —SEE SEE ELEV. r _Q o FOR SPACING I 1 SPACING v•• f-'� �J'1 ��' x eI11 'osa0 _ sauag LUCKS `II11111I II/TTi' . �:' P'•;lam ; .* No.58705 Ck it )03 3 0 0 STATE OF �O f IVAL 11111�` A LYNN MILLER, P.E. P.E.#58705 EQUAL LEG FRAME T'PICAI ANCHORS TYPICAL ANCHORS SEE ELEV. FOR SPACING LMIAMI-OADE=COUNTY APPROVEID 11 MULLION h MULLION ANCHORS II SEE SEPARATE NOA II EDGE DIST. L-_� IN TYPICAL ANCHORS TYPICAL ANCHORS Lp SEE ELEV. SEE ELEV. FOR SPACING FOR SPACING TYPICAL ANCHORS SEE ELEV. - FOR SPACING -- -- - - - - 1/4' MAX. BUCK WIDTH 1 SHIMS E1 c.a 1 1 1 /4iO 8 a Es EXTERIOR •a i. ' q. x Y va TYPICAL ANCHORS >i L SEE ELEV. • ,a` I FOR SPACING EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY INTO WOOD, CONCRETE OR METAL STRUCTURES WITHOUT THE NEED OF A WOOD BUCK. 2 3/I II ` 1� WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%'. THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERL111TED. MIAMI-DARE COUNTY APPROVED MULLION k MULLION ANCHORS SEE SEPARATE NOA TYPICAL ANCHORS a PRODUCT REVISED as complying with the Florida Code :Building 0A-No. 20-0623.10 Expiration Date05/27/2024 Miami -Dade Product Control N N •Aaa a Z. g o 0 _ Z Y in O � >a F 4� u.uoi0 N x ao oN 9M0 m0�1 y Z L m O r W L) L) W C 12 z-LU ❑ Z a: `� O adz 0 Z O ❑ o I-WS F m co O tea o Z ti o g Q z F g Z as°5 ¢�a 0� ON F J �•oe3 �.g- Z Z �EeiLlm�`c x L9 j z 0$�� ? ^ ®� < ¢ o N Ocy� apt •°sa0 saua5 11I,I11 I111 ,, `. �n\A`( ^ SN,1��� t: No. 58705 0. ��Sd5dizFa "''SS70NAL 100" A LYNN MILLER, P.E. P.E.055705 FIN FRAME ILLUSFR EXT. OF NOT BY HOUSE V NOT BY r BZ HOUSE V NOT BY FOR SPACING 1/4- MAX. GAP . 1/2- MIN. JOT BY CGI Y I TYPICAL ANCHORS: SEE - FOR SPACING 48 'SMS (Fu - 74 KSI MIN.) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2- MIN. PENETRATION INTO WOOD 1/4- MAX. GAP . 1/2' MIN. PRODUCT REVISED as complying with the Florida ' Building Code NOA-No. 20-0623.10 Fxplration Date05/27/2024 By Mlam Dade Product Control c rc N S 0 m •nab Q z N O co o u1 2 K Z yO u O J } N {$ uMa Q o N m Z�fc y N OMO W UUd K Z� ^ ❑' zS •�- LL S O jai^ z '- laays co FA ` N Z O c z g aaas .m w O O *a �o F¢ z W z E3'�� = w gs=N D ly = PQ1 'asap sauag �NYILYNN �q�,''%. * No.58705 STATE OF (V�` S II 'l' A", O N I II I ER P.E. P.E.# 58705 MATERIAL PROPERTIES: ITAI PART / QDAItTTI'Y DBBCRIPTION YATHEDAL. YANP./BUPPIJHR/BHItABIS Et CGI-100 - FRAME JAMB O FIXED GLASS 6063-T6 CGI EXTRUDER E2 CGI-113 - FRAME SILL 6083-T6 CGI EXTRUDER E3S CGI-102 - FRAME HEAD 6063-T6 CGI EXTRUDER E4 CGI-103 - MEETING RAIL 6083-T6 CGI EXTRUDER E5 CGI-104 - LOCK PoVL 6083=T8 CGI EXTRUDER EB CGI-105 - HANDLE RAIL 6083-T6 CGI EXTRUDER E7 CGI-106 - SASH RAIL 6063-TB CGI'EXTRUDER ER CGI-107 - 5/16' GLAZING BEAD 8083-T5 CGI EXTRUDER E9 CGI-108 - 0.700' GLAZING BEAD 6063-T5 CGI EXTRUDER E70 CGI-109 - FROM FLANGE ADAPTOR 8083-T6 CGI EXTRUDER E11 CGI-110 - NAIL FIN ADAPTOR 8083-T6 CGI EXTRUDER. E12 CGI-135 - TF FRAME JAMB O FIXED GLASS 6063-i6 CGI EXTRUDER E73 CGI-136 1F FRAME HEAD 8083-T6 CGI EXTRUDER E14 CGI-139 - TF FRAME JAMB 6063-T6 CGI EXTRUDER E15 CCI-140 - 1' MUNTIN 8063-T5 CGI EXTRUDER E76 CGI-141 25' MILLION 8083-T6 CGI EXTRUDER E17 CGI-605 SCREEN FRAME 6083-TS CGI EXTRUDER E18 CGI-114 - SILL SNAP IN 6063-T6 CGI EXTRUDER E19 CGI-115 - SILL FILLER 6083-T6 CGI EXTRUDER E20 CGI-116 - FRAME JAMB 8083-T6 CGI EXTRUDER E21 CGI-117 - HD LOCK RAIL 8063-T6 CGI EXTRUDER E22 CGI-138 - TF FRAME SILL - 6063-T6 .CGI EXTRUDER E23 CGI-109- - FRONT FLANGE ADAPTOR - 8083-TB CGI EXTRUDER M1 CGI-382V - GLAZING BULB VINYL (DUROMEI'ER 75-80 SHORE A) 'PVC - M2 CGI-111 - SCREW COVER (OPTIONAL) PVC - M3 CGI-112 3' O ANCHORS EQUAL LEG COVER/SHIM PVC - ' M4 - 0.700' % 0.040' BEAD GE1200 SILICONE SILICONE GE MS - 0.700' % D,040' BEAD DOW 791 OR 899 SILICONE DOW Mfi - 0.700' % 0.040' BEAD DOW 883 OR 695 SILICONE DOW M7 - 2/ LJTE SETTING BLOCK EPDM DUROMETER BOt5 SHORE A Mg - - PROTECTO WRAP WATERPROOFING OR EQUN. - - M9 684 - ROLLER TRACK PVC M10 CGI-128 2 PER SASH ROLLER HOUSING NYLON - M71 W23201 NG - PILE WITH CENTER FIN WOOL ULTRAFAB OR EQUN. M72 CGI-129 1 PER SASH EGRESS LOCK ALUM. SULWAN M13 CGI-131 2 PER SASH HANDLE RAIL END CAP NYLON M6eM M74 391-N 1 PER SASH ANTIUFT BLOCK NYLON MdtM MI5 - OPTIONAL RETICULATED FOAM 30 PPI - - M76 CGI-134 - JAMB SPACER PVC .PROTOTYPE OR EQUN. M17 A30730401-32 1 PER WD. CAM LACK ZINC TRUTH OR EgUN. M18 CGI-132 2PER WD. 2' SASH STOP PVC PROTOTYPE M79 CGI-111 "O FR. HEAD SCREW COVER F'YC PROTOTYPE M20 CGI-125 2PER SASH SASH CAM (B/T BALANCE) NYLON N&M M22 - VARIES HI-FLO WEEP COVERS PVC AMESBURY OR EQUN S2 - 2 OR 3 PER CORNER d 10 X 1 1/4' I.G. PHL PH. SMS. Si/Sf. ASSEMBLY SCREW - - • S3 - 1 1/4' EMBED. # B % 1 1/2' LG: PHL PH. SMS. FIN ANCHOR SCREW - - S4 - 4 PER WD. / B X 1/2- PH. SMS. Sf/Sf BALANCE BRACKET SCREW - - S5 2 PER WD. � B X 1' LG, fN. SMS. Sf/Si. SPIRAL B. ASSEMBLY - - SB 6 % 1/2' LG. FH. SMS. O CGI-133 &CAM LOCK - - SB - 4 OM. RAIL ft 10 X 4' I.G. PHL PH. SMS. Si/Sf. ASSEMBLY MEETING RAIL - - S9 - 2 PER ANRUFT l!10 X 5/8' LG. PHL -PH: SMS. ST/Si. ANTIUFi SCREW - - Material Mln. Fr Mln. F. #14 Steel Screw 1/4' Elco UlhaCon 114' DeWalt UltraCam UksiI84 6B6&T5 Aluminum A36 Steel PRODUCT REVISED as complying with the Florida Building Code Non -No. 20-0623.10 Expiration DateOS/27/2024 By l:c�.a:,", f. gip•^-.: ADDED BACKBEDDING TYPES - JR - 5/29/20 rc N Y Q 0 Z o 0 Oa z 1Wzu a)00 K Z O Z N ~ (g N 4 C doh � _ °N m Oro Z � O �UUd K U" 0 ¢�Zo � Z O 'L5z� (9 Z 0 w iaa4S H w m Vo z u) y °g a: Z fA Z al°aS J W m � 0 Ir Z e E o LL� F 0 LL O U) N e ® U n Q N = m = apq •°sa0 sauaS LYN * N..58705 S AT OF SS/ONAIL E?.��. A LYNN MILLER. RE P.E.# 58705 FLANGE FRAME HEAD .r"_% FLANGE FRAME SILL II E74 FLANGE FRAME JAMB II E12 FLANGE FRAME JAMB (FIXED) O FLUSH FRAME HEAD LJ FLUSH FRAME SILL E20 FLUSH FRAME JAMB (MOVING; .611 2.505 .065 TYP. 1.015 .500 1.245 E7 FLUSH FRAME JAMB (FIXED). E4 MEETING RAIL 1.766 .065 TYP. 1.015 1.220 1.043 O LOCK RAIL 1 E21 ALT. LOCK RAIL E6 HANDLE RAIL J1.395 •SASA � H RAIL 065 1.550 1.680 1.395 E71 NAIL FIN ADAPTER 1.496 F ' --I 2.264L 1.255 F. Eta SILL FILLER 1.450 100 .550 •050 E23 FLANGE ADAPTOR '490 .705 .050 TYP. 664 O 5/16" GLAZING BEAD 1.395 plea .050 1 065 N3 FLUSH FRAME COVER .120 .705 .050 TYP. 864 O .700" GLAZING BEAD 1.449 293 .060 1.413 M2 SCREW COVER PRODUCT REVISED a9 complying with the Florida Building Code NOA-No. 20-0623.10 Expiration Date05/27/2024 Miami-0ade Product Control "s K N =L Q ry is! nay Q z '8i o N 0 uu11 i> 7130 x :i z p = J } ^ O r 7g uxw0 N = OMo m z it O U U a z a�zo LL O O Z L] m_ 1�45 2 N G ul r Q Z a1w5 W O a ^� O I= e3$LL�x y LLJ _z ¢ 33Wo T ¢ R N U O 2 apt "osa0 saua5 `1A11111111/,, �YcEnISF ,n No.58705 a.� Sao �O�'.• u^TA OF (V-` A LYNN MILLER, RE P.E# 58705 q 52 IITI'll �%� j� PRODUCT REVISED as complying with the Florida 52 Bulldln9 Code NOA No. 20-0623.10 Expiration Date05/27/2024 By Miami -Dade Product Control "s a N Y Q .4, FRAME TOP CORNER _1c11 z G Y o GIDQ W p K O Z IIMOId ' VENT TOP/BOTTOM CORNERS .. 52 z It >- ° In F J m 2 El N 0M0 006 K v O zW S 7 0 O Z O Iaa4S H Z w m o z 10 Q Y N oe 3 ° � ¢F Z N� K arn�3 z p F w co N 5 ® a ^ 0 � 0 U = ep1 •asap seuag `�11 rrr/ No. 58705 ' :FRAME BOTTOM CORNER 0, •' STATE OF FIXED MTG. RAIL CORNER / ZONALIE��`� A LYNN MILLER, P.E. P.En58705