Loading...
HomeMy WebLinkAboutNOA; Series Sentinel 110 Aluminium Single Hung Window, OPI M MIAMI-00p M CO CONTROL SECCOUNTY 0GO PRODUCTON 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) wwiv.miarnidadL.gov/hui1din- CGI Windows and Doors, Inc. 3780 W 100 Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in. Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade'County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to . have this product or material tested for quality assurance purposes. If this product or material fails to. perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Sentinel 110" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. SH110-LM-NOA, titled "Series 1.10 Alum. Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed' and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall, bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and'followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-1018.08 and consists of this page 1 and evidence pages E=1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0722.09 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 9/1/20 Page 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUSNOA's A. DRAWINGS 1. Manufacturer's' die drawings and sections. (Submitted under NOA No. 10-0510. 11) 2. Drawing No W10-03, titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10, with revision D dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) B. TESTS 1. Test reports on- 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared. by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 2. Test reports on. 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 .3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to, qualify.DuPont "Butacite" PVB interlayer; Duraseal® and Super Spacer(9 insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) Manuel Pe Product Control E NOA No. 20 Expiration Date: September Approval Date: September E-1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED, UNDER PREVIOUS NOA's (CONTINUED) B. TESTS .(CONTINUED) 4. Test reports on-,1) Air Infiltration Test, per FBC; TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, .per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a series "Sentinel" aluminum singlehung window, prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J. Abraham, P.E. , (Submitted under NOA No. 10-0510. 11) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6" Edition (2017), dated 09/29/17, prepared by Al=Farooq, Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas®1 (Clear and White)_ Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America,_ Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 00/07/17, expiring on 12/11/18. 4, Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. Manuel i Product Control E NOA No. 2U Expiration Date: September Approval Date: September E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED i 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) F. STATEMENTS I 1. Statement letter of conformance, complying with FBC 51b Edition (2014), and of no financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Laboratory. compliance letter for Test Report No. HTL-0080-0101-10, issued by, Hurricane Test, Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.11) 3. Test Proposal for the qualification of Butacite@ PVB glass interlayer by DuPont as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by, Jaime Gascon, ,Supervisor. (Submitted under NOA No. 15-0512. 10) .; G. OTHERS 1. Notice of Acceptance No. 15-0512.10, issued to CGI Windows & Doors for their Serieg "Sentinel 110" i Aluminum Single Hung Window - L.M.I., approved on 08/06/15 and expiring on 09/22/20. Manuel Perez, P, Product Control Ex TM NOA No. 2 0722. Expiration Date: September- , 2 Approval Date: September 1 , 20 E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No SH110-LM-NOA, titled "Series 110 Alum Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on� 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 . 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested -to qualify Dowsi1791- and Dowsil 983 silicones,- per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc.,, Test Reports No.: PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1; PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) 'and. FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, C.GI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08124%N and signed and sealed by Idalmis Ortega, RE C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 711 Edition (2020), dated 07/11/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. Product Control E NOA No. 2U Expiration Date: September Approval Date: September E-4 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. . 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/;08/24. 3. Notice of Acceptance No.18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18; expiring on 12/11/23. 4. Notice of Acceptance No.17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 61h Edition (2017) and the FBC 7th Edition (2020), dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated July 16, 2020, signed and sealed by Anthony Lynn Miller, P.E. 5. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 17-1018.08, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 12/2.1/17 and expiring on 09/22/20. Manuel Tpe, Product Control•E ,1 NOA No. 29 Expiration Date: September Approval Date: September E-5 D.L.O. (FIX. LITE) 20 9/16- ** MAX. A HEAD/SILL n u II II 11 11 II II re -)if ! f! ===__#_— C 47 7/16- D.L.O. (FIX. LITE) 20 9/16- MAX. Al HEAD/SILL i II II II �, If II •� II 0 uC� 47 7/16" FLANGE & FLANGE ADAPTOR FRAME EQUAL.LEG FRAME SERIES SENTINEL 110 ALUMINUM SINGLE HUNG WINDOW LARGE & SMALL MISSILE (LM & SM) DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. NTINS APPI FIN FRAME APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WINDOW WITH OTHER CENTER ANCHOR REQUIRED WHEN MLAM1—DARE COUNTY APPROVED WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN SPACING EXCEEDS 20 9/16" PRESSURE FROM WINDOWS OR MULUON APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) AND2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). LAMINATED GLASS 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED INSULATING -LAM. GLASS PRODUCT LOADS TO THE BUILDING STRUCTURE. SMALL MISSILE IMPACT ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED _ LARGE MISSILE IMPACT EMBEDMENT TO BASED MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON —COMPRESSIBLE MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, Le. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE, ETC. . CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL PRODUCT REVISED as w [ Ing with the Florida Building Code REVISED FOR 2020 FBC, ADDED ANCHOR TYPE, BACKBEDDING & REFORMATTED -JR- 07roz/20 p m 0 0 w slap O Q o $7 Z N QON IaOL mO z v . u a0 O !q W U U d K O ZZs, IWzI W n � S (0. aN JMO ILL r Z O — W C9 O � C is o If a -j cmo Z W 1aa45 w of W y0. 3 cm z E3 Sa�� rn F W, = w F ¢ o ®z o c� s W W W _ rn alll •asap saua5 ``7\1111111/l7j' ` � 0 LYNNj/� ` ��i \,\CENgF �F i ` No. 58705 ••; M�[/ U � � i sS A LYNN MILLER, RE P.E.p 58705 EQUAL LTTNS WDiDORS DIM I= CApAmTr - PSP 1IdNGE DDm. BUCK BDDI. . muss TYPID 'L eAv 0L8B TYPE 'B-&%r Wuni HEIGHT WIDTH HDGKI DU.(+) m.(-) D (T.(+) 110'.(-) 18-1/8'- 26-1/2' 37" 49' 53-1/8• 28' 18-1/81 25-1/2' 38' 4B' 52-1/8• 1. 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.D 05.0 75.0 75.0 80.0 85.0 75.0 75.0 804 85.0 19-1/8' 26-1/2' 37' 48' 53-1/e' 3a-3/8' 18-I/8' 25-1/2• W. 48' 52-1/8' 37-3/8' 76.0 75.0 80.1) 85.0 75.0 75.0 80.D 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 1 75.0 80.0 85.0 19-1/e' 25-1/2' 37' 49' 53-1/8' 50-5/W 18-1/8' 25-1/2' 38' 48' 52-1/B' 49-5/8' 75.0 75.0 80.0 85.0 75.0, 75.0 80.0 8,5.0 75.0 75.0 80.1) 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 55.0 19-1/8' 26-1/2' 37' 49' 53-1/8' 0. 16-1/8' 25-1/2' 36' 48' 52-1/8" 62' 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 76.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 15.0 80.0 65.0 19-1/8' 26-1/2' 37' 49' 78' 18-1/1 25-1/2' 38' 46' 52-1/8' 75' 75.0 75.0 80.0 ..0 75.0 75.0 90.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 r53-1/5' -1/8' 25-1/2' 45-1/2' 76.0 75.0 90.0 a5.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 85.0 75.0 75.0 80.0 &5.0 WIDTH EQUAL LITES NOTE GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219. UMUAL, LMS VMOVS DESIGN UW CBPAf= = PSP FUNGN DIYB. BUCK Dills. KMTOP UM GUM WM WWW' Gib n7M Vh Bl' mmm HI•jGW Woo moff 'A' Dm E1U.(+)' BIT.(-) E%f.(+) INL(-) 53-1/8' 78' 52-1/9' 75' 36-1/4' 75.0 75.0 80.0 85.0 49' 79 48' 78' 39-1/4' 75.0 ' 75.0 80.0 B5.0 26-1/2' 31' 33' 37' 43' 85' 25-1/2' 30' 32' 38' 42' 84' 70-5/e' 75.0 75.0 80.0 85.0 83-5/8' 75.0 75.0 80.0 BSA 80' 75.0 740 B6.0 85.0 53-1/2• 75.0 75.0 80.0 B5.0 45-1/4' 75.0 75.0 1 80.0 85.0 UNEQUAL LITES (ORIEL TYPE) Y! TIP. YX, TYP. BUCK DIMS FLANGE FRAME FLANGE DIMS BUCK DIMS �j EQUAL LEG FRAME BUCK DIMS FIN FRAME BUCK DIMS FLANGE ADAPTOR FRAME FLANGE DIMS UNEQUAL LrrES (ORIEL TYPE) PRODUCT REVISED as complying with the Florida Building Code �JI o o � •nab aloe 0 0 d Z of z Z z O mZ � 00 " a = '7 W K Z S co UMp 0W1 Z a L" z a W a z m :3 = C o W i7 0 N Is o ai in G o Z (A 7aa4S 3 2. NL 9� 1Z~_- zg3 D�Q w z C7 to 0 v c�in4� tWn , y e11'1 'asap saua5 oAYILYlvIv .. .�• F=�? L10ENyF �/CCU No. 58705 ���'•, TE F s/ NAL 0\0\ / AO111��716)II�1 ' P.E. P.EA 5B705 .075' SaBax CP With PET Core By 'Eastman Chemical Go.' M .090' Saflex Clear And Color Glass By 'Eastman Chemical Co.' ,x .090' SentryGlas® By 'Kuraray America, Inc.' 1/0- ANNEALED GLASS .090' Trosifol PVB By Kuraray Ameica, Inc.' 1/8' ANNEALED GLASS Im GEcI 1200 N A `DOW CORNING 791, / 899. 983 & 995 GLASS TYPE 'A' 5/18' OVERALL LAM. GLASS (L.M.I & S.M.I.) 075' Safex CP With PET Core By 'Eastman Chemical Co.' ' 1/8' ANNEALED GLASS z .090' Saflex Clear And Color Glass By 'Eastman Chemical Co.' 1/4- AIR SPACE .090' SmtryGlos® By 'Kuraray America, Inc.' 1/8- ANNEALED D90' Trosifol PVB OR TEMPERED- GLASS By Kuraray Amelca; Inc.' 1/8' ANNEALED GLASS SILICONE, GE 1200 5 !? DOW CORNING 791, 899, 9B3 & 995 " M1 XL EDGE SPACER ST. STEEL BY 'CARDINAL' 14 OR 0 DURASEAL BY 'QUANIX' E9 OR 1 SUPER SPACER BY 'QUANIX' W GLASS TYPE 'Ai' 0.70' OVERALL INSUL LAM. GLASS (L.M.I & S.M.I.) .075' Saflex CP With PET Care By 'Eastman Chemical Co:' M .090' Saflex Clear And Color Glow. SBy 'Eastman Chemical Co.' .09D' SentryGlas® By 'Kuraray America, Inc.' 09D' Troeifol PVB 1/8- HEAT STREN'D GLAS By 'Kuraray Amelca, Inc.' 1/8' HEAT STREN'D GLASS SILICDNE: m GE 120D DOW CORNING 791, M7 899, 983 & 995 ' co n - -- 0 1 1 1-) GLAS• S TYPE 'H' 5/16- OVERALL LAM. GLASS (L.M.I & S.M.I.) .075' Saflex CP With 'PET Core By 'Eastman Chemical Go.' 1/8- HEAT STREN'D GLASS.090' Saflex Clear .And Color Glass By 'Eastman Chemical Co.' 1/4' AIR SPACE 090' SentryGlas® By 'Kuraray America, Inc.' 1/8- HEAT STREN'D .090' Troalfol PVB OR TEMPERED- GLASS By 'Kuraray Amelca, Inc.' 1/8' HEAT STREN'D GLASS SILICONE, = m GE 1200 DOW CORNING 791. N M1 899, 983 & 995 XL EDGE SPACER ST. STEEL BY 'CARDINAL' OR C _ OURASEAL BY 'QLIANEW OR SUPER SPACER BY 'QUANDP 1 GLASS TYPE 'HI' 0.70' OVERALL INSUL LAM. GLASS (L.M.I & S.M.I.) • FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LATE (CAP) MUST BE TEMPERED. PRODUCT REVISED ascomp with the Florida Building Code NOA-No. 20-0722.09 ADDED BACKBEDDING TYPES - JR - 07/07/20 s LOV Y Q O �1 ,eda n S o 0 LiUu m °7OO W O Z ZM a Zp p 2 LU OZLLQ U) u aD y "Vu a:sZs Qa�Z� 7 oN (D OMO Wn v cc = W W 0 La Z J (� A th o v Z N Ix y 1ea45 61 � 0. p7 W DC 3 �wm J Z Z O 6c Q �"O' o W _ r E�� W a) o V � U) U) a8f rosaD sauag �. `��11YILYNIV4 i No. 58705 rTE F S�ONAL A. LNNN NILLW. P.E. P.E# 58705 TYPICAL ANCHORS SEE ELEV. 1BY FOR SPACING WOOD BUCK �,. �d r `• sad. SWEEP LOCK OPTIONAL TO EGRESS LOCK AT SILL m TYPICAL ANCHORS SEE ELEV. t�3 FOR SPACING m LE-DGE og � S= i 2 3/8- MIN. 2 3/� WHEN. USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%-. THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. FLANGE & FLANGE ADAPTOR FRAME s WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WOW. o MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. 1 0 W � S4 1 i ES M9 . O I 14 t d i a �o. .,.a -• , . ..:,p. � 4 .. a EDGE DI. J "' . EDGE ° :• \ .• •.. I TYPICAL ANCHORS ' r. DIST. f I TYPICAL ANCHORS •. SEE ELEV. FOR SPACING BY SEE ELEV. WOOD BUCK FOR SPACING HORS IIAMI-DADE COUNTY APPROVED IULUON h MULLION ANCHORS 'SEE SEPARATE NOA EDGE DIST. I TYPICAL ANC% SEE ELEV. FOR SPACING TYPICAL -ANCHORS: SEE ELEV. FOR SPACING 1/4" DIA. TAPCON BY 'ITW' (Fu-125 KSI, Fy=100 KSI) 1 /4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) 1/4" DIA. ULTRACON+ BY 'DEWALT'(Fu=184 KSI, Fy=148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1.-1/4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) #14 SMS OR SELF DRILLING SCREWS (Fu— KSI, Fy-57 KSI) INTO MWMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) -THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN. STEEL ;,1/8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL.EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD.STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD, SILL OR JAMBS SG=0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS I'm - 2000 PSI MIN. PRODUCT REVISED as comp%yIn8 with tho Florida Builtlin8 Cod. ADDED ANCHOR TYPE - JR - 07/07/20 z a � Q o r= � p •nsy m o "IW to p C Q z z co W i dC9 F o 0 Z ii uMwO w V u d Z_ QWZWW 'ON 9M0 a j r z = W U- w w O 0 - 1 p z V) sr iss45 w z W Fl o� Ot_u = J Q J Q Emma z W og� z =Rn' w w Z rn o UJ g LL Una a)ILL 1.3.5G seue5 LYNN�7j�'�i CENg.. Mfw 41 • v1 F ;�`,p No..58705 •W o . 1 F 'l/v; ;o'•. S/ONAL ` A. LYNN MILLER, P.E P.E.058705 -& FLANGE ADAPTOR FRAME FLANGE ADAPTOR FRAME INTALLATION DETAILS SHOWN ON PAGES 4 AND 5 APPLY TO BOTH FLANGE FRAME AND .FLANGE ADAPTOR FRAMES. PRODUCT REVISED as eomplying Building with the FloridaCode NOA-No. 20-0722.09 gill a irrr/�� � ,kV LyNJV ........... No. 58705 .EGF� S 10NAL 1'r— A LYNN MILLER, RE P.E.# 68705 TYPICAL ANCHORS SEE ELEV. 1BY FOR SPACING WOOD BUCK EDGE-DIS17.it r TYPICAL ANCHORS SEE ELEV. FOR SPACING 9 EQUAL LEG FRAME II MNMI-DADE COUNTY APPROVED II I I MUWON k MULLION ANCHORS I I li SEE SEPARATE NOA it PRODUCT REVISED I I as complying with the Florida Building Code L l TYPICAL ANCHORS FOR SPACING MNMI-DARE COUNTY FOR SPACING L SEE FLEV. - Nllam pads Produe�t'Co trot I FOR SPACING - APPROVED MULLION Ec'MULDON ANCHORS o I S MB 1/4' MAX. BUCK WIDTH BUCK WIDTH SEE SEPARATE NOA ' J , SHIMS BUCK WIDTH o s '• ° r- —i� SWEEP LOCK '•' I N Y Q OPTIONAL TO 1 EGRESS LOCK I I o •n°B AT SILL -, —• - — � c O e j j O Izu� °I°0 0 O I I t zd OZ z 6 Z B E5 GE A3 F EDGE ' E4 DIST. L J Q U' o O Y m Z% g U1 0 "'0 in 0=W 5SS j 1 m #14 X1' FH. SMS. z v 7 °N j Wo j� z JMO N 3 f0 EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY. m 19 1 w- y 1°°a5 ` a o INTO WOOD, CONCRETE .OR METAL STRUCTURES ;,� °ry o J aWITHOUT THE NEED OF A WOOD BUCK. o o o z W i 1 ate_ o C7 Zr rc 4I� 2 3/8' MIN. RS LL "°� -1 V) W N 1 802 {Nil j p 54 ® W C7 = - °111 nse0 seueS i E8 2 3/8' MIN. . w ; . -1 d• d . MB ' ` .•:e < ,� .:' ' J, \ LYNNQ "'I, iv ��\ •.r^" - d `i E j •TYPICAL ANCHORS �� •��`•. •'�ICEPJSF '•zSEE i C. I 1 �` *• , a: 'I" I FOR SPACING ` .e No.58705 �• WHEN USED THE MIN. WOOD BUCK, D DEPTH SHALL BE 2)6". THE USE OF 0,n .•/•. • E6ce •.� 'r •. DEEPER OR BEVELED WOODBUCKS IS DIST.� CHORS PERMITTED.SEE ELEV. •'' 1BY I FOR SPACING ��lllllll y A WOOD BUCK LYNN MILLER, P.E. P.E.# 58705 TYPICAL ANCHORS ILLUSTRATIVE DTLS. ONLY FOR SPACING Flit/ FRAMEEXT. OR INF. FINISHES E1 NOT BY CGI z ' s r ' HOUSE WRAP TYPICAL. ANCHORS: SEE ELEV. FOR SPACING NOT BY CGI #B SMS (Fu=74 KSI, Fy=57 KSI) OEt INTO 2BY WOO BUCKS OR WOOD STRUCTURES PRODUCT REVISED A2 Q as comp)CIonB with the Florida BACKBED MIN. PENETRATION INTO WOOD NOA-No. do 20.0722.09 M2 CAULKING Eiplration Date• 9122/2025 ss Br— ' Miem ede Product•!: trot � M9 a 0 c C SWEEP LOCK N 4 Q 1 OPUONAL TO a EGRESS LOCK o •nay AT SILL iz O Lu WOOD NOT BY CGI RE t/a' MAt(. BUCK HEIGHT 1/4� Wk w al°G K Z IJ GAP B 6 0 1/2- MIN. 1/2' MIN. ,Q> N F 'W+ o E4 1 m 6U2a 'ON 1 ZZ . � 0M0 i DZ a�z� (3) x LL B4CKBED O • i CAULKING c z Z r iq G ! O cn 11145 u� O W o t 3 ❑ .� Z 2u,1 �+ 05 = ¢ F a 6 a o J Z. .W o 0 C2 s4 •' t O _ W Oz _ m$ W 1 HOUSE WRAP O _ " aql 'asap seua5 E6 I- NOT BY CGI i E3 ® EXTERIOR \\``tL,illlllrrrrii M9 . D.L. OPG. `�'��OS•4CEN,gff'1j/C�'�ii 14 BACKBED C(�, •:�� CAULKING = No. 58705 HOUSE WRAP - ��O AT OF NOT BY CGI a g %��`S'••!��ORIDP,. •'G���: c'J � 1 TYPICAL ANCHORS A LYNN MILLER, P.E. SEE ELEV. FOR SPACING P.E058705 ITEB PART / QUANTITY DESCRIPTION HATSIDAL MANP./S1DPPLLlER/RBIGB1f9 E1 CGI-1 DO 1 FRAME HEAD 6063-T6 - E2 CGI-101 1 FRAME SILL 8063-T6 - E3 CGI-102 2 FRAME JAMB 6063-TB - E4 CGI-103 1 MEETING RAIL 6063-T6 - E5 CGI-104 1 LOCK RAIL 6083-T6 - E6 CGI-105 1 HANDLE RAIL B063-TS - 'E7 CGI-106 2 SASH RAIL 6063-TB - EB CGI-107 AS READ. 5/16- GLAZING BEAD 6063-TS E9 CGI-108 AS READ. 0.700' GLAZING BEAD 6063-T5 - ElO CGI-109 AS READ. FRONT FLANGE ADAPTOR 6063-TB - Ell CGI-110 AS REOD. NAIL FIN ADAPTOR 6063-T5 E12 CGI-135 1 FLANGE FRAME HEAD 6063-T6 E13 CGI-136 2 FLANGE FRAME JAMB 6063-TB - E14 CGI-137 1 FLANGE FRAME SILL 8063-TB - E17 CGI-605 OP ION& SCREEN FRAME 6063-15 - M1 CGI-382V AS REOD. GLAZING BULB VINYL (DUROMETER 75-80 SHORE A) PVC - M2 CGI-111 OPTIONAL SCREW COVER PVC PROTOTYPE. OR EQUIV. M3 CGI-112 AS READ. EQUAL LEG COVER/SHIM, 3- LONG AT ANCHOR LOCATIONS PVC - M9 SUPER BOOST 2/ WDW. SPIRAL BALANCE - BSI OR EQUN. M10 - 2/ WDW. BLOCK/TACKLE BALANCE - BSI OR EQUN. ` M11 W23201NG AS REQD. PILE WITH CENTER FIN WOOL ULTRAFAB OR EQUN. M12 CGI-129 1/ WDW. I EGRESS LOCK ALUM. SULLIVAN M13 CGI-131 2/ WDW. HANDLE RAIL END CAP NYLON M&M M14 E26019WN - 0 BULB-T SLOT PVC ULTRAFAB OR EQUIV. M15 CGI-133 4/ WDW. SASH GUIDE(SPIRAL BALANCE) NYLON FA&M M16 CGI-130 2/ WDW. SASH TOP GOIDE(SPIRAL BALANCE) NYLON M&M M17• A30730401-32 1/ WDW. CAM LOCK ZINC TRUM OR EQUN. M18 OGI-132 2/ WDW. SASH STOP, 2- LONG PVC PROTOTYPE OR EQUIV. M19 - 2/ UTE SETTING BLOCK EPOM DUROMETER, 85±5 SHORE A M20 CGI-125 2/ WDW. SASH ,CAM (B/T BALANCE) NYLON N&M M21 - 2/ WDW. SIT BALANCE TAKE OUT CUP - BSI OR EQUIV. M22 146-6 2/ WDW. WEEP COVER NYLON AMESBURY OR EQUN M23 CGI-134 - SILL SPACER PVC PROTOTYPE OR EQUIV. S2 - 2 OR 3/CORNER 111 10 X 1 1/4- LG. PHL. PH. SMS. ST/ST. ASSEMBLY SCREW - - S4 - 4/ WDW. # 8 X 1/2- PH. SMS. ST/ST BALANCE BRACKET SCREW - - S5 - 2 WOW. B X 1- LG. FH. SMS. Sr/Sr. SPIRAL B. ASSEMBLY - - S6 - 2/ LOCK 6 X 1/2- LG- FH. SMS. 0 CGI-133 & CAM LOCK - - PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0722.09 Exl?lm"Y'�AL''4'W &tlon� D��ar�t//e//�,•,, 9/22/2025 By Mlam ade ProduerCyntrol c :8 a 4 o � •naa O m O 1n O Q L� 1oNi 'ia0 d, O 2 qt Z aoN s0 W a in z � 0 ,. uw.wN �yULd K ZZ a122v > aN Wo�� Z Sma Q.2Ea O m S LL LU O N b O co A o 6 Z y O O N IaaVS w J ZO rji Igo L A 9L1II1L11L 6�G � r ZrC E U1 NCI O. Q 3 � W y W Z�x�W LL O O J LU = LLi ��^, m aCO m m apt •�ca0 cauaS L7 L1111111/!/! Ll'NN • L10ENgF'•. ��� ' No.58705 F AL A LYNN MILLER. P.E.P.E.#58705 2505- 2.50.5 .085 O65 1.745 1.550 ,8,1 .81 .1.fi80 .745 O6 ,.245 745 O65 lyP. .050 1.015 1.015 1.395 Et2 FLANGE FRAME HEAD Et FLUSH FRAME HEAD E71 NAIL FIN ADAPTER TYP 3.175 1.429 1 065 1.000 .500 E,4 FLANGE FRAME SILL E73 FLANGE FRAME JAMB .490 .705 .050 TYR O .864 5/16- GLAZING BEAD 1.3951 .180 .050 .Dfis M3 FLUSH FRAME COVER Oo FLUSH FRAME SILL E3 FLUSH FRAME JAMB .120 .705 I .050 iYP. O +i .864 - .700' GLAZING BEAD 1.449 293 .060 1.4,3 to SCREW COVER 3 E4 MEETING RAIL 1.220 1.043 1.788 085 7YR 1.015 Oo LOCK RAIL 2.195 rai 2 1.043 1.015 Efi HAND RAIL 1.395 .745 .665 .875 L SASH RAIL FRAME TOP CORNER 1.450 180 .55D ,050 E,0 FLANGE ADAPTOR VENT TOP CORNER VENT BOTTOM CORNER PRODUCT REVISED as eomplying with the Florida Bullding CCode ..A-Mo. 20-0722.09 �I o' i`1 • Y Q cv 0 •�aa W m n o alod � 0 O 2 �N F W. oZ m ura0 N it K 00 ZZ 0M0 LL p = w w 00 A - N It Z. V) o� ia54S Otj w W cri o z L m Q Z ,CyjZ� r! MW ® � 0 N UnS� W N Z fA aril 'asap sauo5 LYNN � � 1.IGENSC •• ��� .: No.58705 ; &6�j Qj lS ///" YONALfill0%�G A. LYNN MILLER, P.E P.E.#68705