HomeMy WebLinkAboutAPPROVED REVISION S1-01 Foundation Plan REVISION 1 - Maverick Boats Plant Expansion 04-08-2128.24 [A
10 11 12 13 14 15 16
17
25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25-0" 25'-0" 25'-0"
18 19 20
Lu
z 25-0" 25'-0" 25'-0"
J
U
H
Q
2
1/2" TS28.24
Zr EXPANSION JOINT
r _1 r -1 r
3 -� 112__�-6"
----- ----- - - - -
53.01
F70
12'-6"
1/2" SLAB
EXPANSION JOINT C.J. (TYP.)
21
25'-0"
TYP.
1
1.01
r -----r
TS28.24
22
23
25'-0"
25'-0"
24
25'-0"
25
25'-0"
26
25'-0"
27
25'-0"
28
25'-0"
1/2' TS28.24
EXPANSION JOINT
r-1 r- r r_1 r_1 r-I r
- - - - - - - - - - - - - - - - ----- 3 TS28.24 - - - - - -
F70 A F70 A F70 A F70 F70 A I I A F70 A F70 A
II
12'-6" I I 12'-6"
1/2" SLAB OIL EL. 0'-0"
EXPANSION JOINT T T.O. SLAB
IICL IL
II
II
53.01
TYP. ( I TYP.
C.J. (TYP.) 1
S6.01ZF6080 F6080 F8080 F8080 F8080 I I �d
2
_ --- - -
r
s3.o1
J L J Ll r, L, iJ TYP.
ui I� III I I I I I I I I
I III I I I I I o I I
II I I I I I I I I N I I
I°0_ 1 1°2 1 Ia2 1 Ia° I I
I I I� I I't I I� I 16 I I
I I F _ I I I _TYP. 2 1 1_ ch 1 1_
II
1/2" SLAB I( 1 54.01 1 ( 1
EXPANSION JOINT
III I I I I TYP.
1 1 I ( z RUN TS20.12 REINFORCING I S 01
THRU TS48.18 i
III °-° 1 1 I I I I N
1/2" TE-2 TS20.12
III o I I r -�
EXPANSION JOINT TYP.
III Q I I N l n r Mw-,- _-1 _ IN 11 3
I z I I _ of I l I I I I Io1 I - S4.01 _
(E)F4 I I (E)F4 III I I �I �I I (E) � 1F4 I �1 I I
E-2 I I I (E)F4 Co I V(E)F4 ~ I. I I I TE-2 I I I ��J�(E) 4
-� - J Co -�
MW
FS24x24 J L L J J` (E)TS24x24 J L
Z' � S4.01
J m U BB-1 (8'-4")
w 6 0)� �� 0)� 54.01
N i I I N i
mm mm
mm -- mm
BB-1 (8'-4")
5 12" x 1 5/8" x 16 GA. GALV.
S4.01 STEEL STUDS @ 16" O.C.
W/ BRIDGING @ 1/4 POINTS
ELECTRICAL ROOM
ROOF FRAMING PLAN
1/16" = 1'-0"
29
25'-0"
30
25-0"
31
25'-0"
18
I
■
PARTIAL FLOOR PLAN (WEST)
SCALE: 1/16" = 1'-0"
NORTH
32
25'-0"
TYP.
1
S3.01
r r r
6" CONC SLAB ON GRADE .�
W/ 4x4-W4xW4 WWF CENTERED r
OR #4 @ 12" O.C. EACH WAY
CENTERED, ON 10 MIL VAPOR
BARRIER ON COMPACTED
4 I
I
TREATED SUB -SOIL (TYPICAL)
`-
S3.01
TYP.
TYP. I
I
1
F8080
F8080 S6.01
F8080
F8080 I
I
F8080
F8080
F8080
F8080
r
r
II
r
r
r
r
�
-- - -- 1 `
`
--
_
_
----- i�
-----
�-`=
--
--
j L,
r
L,�
I
I
L,
rj
L,
rj
L,
rj
Li
rj
I
I I
I
I
I 1111
I
I
I
I
I
I
C.J. (TYP.)
III
275'-0"
FUTURE MEZZANINE FOOTPRINT
I
I I
I
I
1
°�
I
I °�
I
I °
I
I °2
r,
I°°
�.
10°
o
I6 I
I�
I
I� I
I
1
Io6
1
1c
106
IC6
o
I� I
IF-
I
I� I
I
I
I�
1
I�
�-
1�
v
F
z
_
1
-
_
_
-�
z
-
_
_
1
2 I
I
I
I I
1/2"
SLAB
I
I
EXPANSION
JOINT
I
I
uj
54.01 I
I
I
I I
I
(
I
I
I
I
I
uj
Li
I
I
I
I
I
I
I
C.J. (TYP.)
III
-Q:
ASSUMED MEZZANINE
COLUMN LINES
1
1 I
I
I
I I
I
1/2"
TE-2
I
I
I
I
III
I
I
EXPANSION
JOINT
I
I I
I
I
I
I
I
I
I
I
I
III
I
I I
I
_ I
I I
I
_ I
I
I
I_
1
1
111
_
_
I I
(E)F4 I
_
I
I (E)F4
I
(
I
I
_
(E)F4
III
I
I
()F4
I
(E)F4 I
I I
1 (E)F4 I
I I
(E)F4 I
I
I
I I
I (E)F4 I
-�
V -�i
-ram
-J
--rL
TE-2 -�
-_d
-rL
--L
--
J
--
J --
- )//4J--
FOUNDATION NOTES•
1) (E)F4 = EXISTING 6'-0" x 6'-0" x 30" THICK CONC. FOOTING
2) (E)TS24x24 = EXISTING 24" x CONT. x 24" THICKENED SLAB EDGE
3) ALL CMU IS TYPE "MW-1" UNLESS NOTED OTHERWISE
4) ® = HAIRPIN BARS, SEE DETAILS ON SHEET S2.01
5) SEE ARCHITECTURAL DRAWINGS FOR ALL CMU OPENING DIMENSIONS
33
34
25'-0" 25'-0"
7aS
35
25'-0"
19
25'-
a)
°D
O
NCo
O
o
Q
a
Z
'v
O
C/)_
w
L.L
N
M
V
O
M
Z
o
O
I-
U
r�
H
C)
z
O
U
ry
O
LL
U)
w
U)
J
Q
m
�
U
Q
H
W
C
0-
h
"t
rn QD
M
rK
0
J
1
Q
-
m
C N
CNI
Z
o
- LL
-0
M_
W
7
O
OQ>
Com N
C �
CD
%�
N O
o
W
a
z
oN
uj
w
cn
Q
^
Co
N I- -
70
K A)
F70 (J
F70
v
t�
L
o
i
NI
O
6
Lo
N
A
r�
55.01
B ~
vol
C.J.
(TYP.)
o
F
1
I
..
r
S5.01
F30.14 (-5'-0")
F40 I
o
20
>_
TYP. 4-SIDES
I
1
0
... - - -
---
- - - - - - - - -
------------�
- - - -
o
N
N
DIP POOL
3
S5.01 I
I
(BY OTHERS) P-1
(-2'-0'
O
-a1
55.01
C.J.
(TYP.)
I
F40
(-4'-8")
00
8080
I
I
/
/-F-6080 -_-
- -----------�
2
r
I_011 _
D io
--
S5.01
S3.01
J L_
J L_ J
O
_
(p
N
//
TYP.
-�
-oj
P-1 (-1'-0")
P-1 (-1'-0") 1
B
F6080 (-3'-8")
F6080 (-3'-8")
2 P-1 (-2'-0")
F40
55.01 F6080 (-4'-2")
(-2'-0")
N i
o
N
EXISTING 10" FIRE
SERVICE WATERMAIN
B I
/
SEE SHEET S6 01 FOR
o CTRUCK WELL AND CANOPY
/
I /
F40 I /l
TYP. (-2'-0") N I of // o
b // 1 Z
s3o1 1 �I /C14// LO
a.
(E)F4 (E)F4 (E)F4 (E)F4 O / -
Z
-� TE-2 O
---- ---- ---- - - - H
J L (E)TS24x24 J J o Q
(E)F4 I E
VERIFY ALL DIMENSIONS WITH METAL
BU I LD I N6 MANUFACTURER'S
DRAWIN65. IF DIFFERENT, METAL
BUILDING DIMENSIONS CONTROL.
NOTIFY EN61 NEER IMMEDIATELY OF
ALL I NGON515TENG I ES.
EXI ING z O
o) IL
LO ING NE 3
Dig' Ily signed by Allen Wieder, PE E
/Al r F 434 4
Allen Wieder, PE FL 43444,
er Engineering, Inc, ou,
PE FL 43444 email=awieder@wiederengineering.c
om, c=US
Date: 2021.04.08 13:12:59-04'00' O
PARTIAL FLOOR PLAN (EASI ulieclep ineepin 9nc.
�� E U)
SCALE: 1/16" = 1 -0' STRUCTURAL ENGINEER z
NORTH 11718 SE FEDERAL HWY #373 Uc #28036 (772) 546-5823
HOBE SOUND, FL 33455 FAX: (772) 545-3734 �
a)
1--0)
O M
Co
J
.` LL
Cn
Z U
L
O �
M LL
O
v
m Co
U LL J
U
J U
Ua
Lo If
t LL
LL
0
Lo
CD 0
N CD
ao
L Oa) IRt
Q
E o c
a�
Z6m
Z m_
0 C) N
0
p p N