HomeMy WebLinkAboutAPPROVED REVISION S2-01 Notes & Schedules REVISION 1 - Maverick Boats Plant Expansion 04-08-21STRUCTURAL NOTES CONTRACTOR NOTE: THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. WIEDER ENGINEERING, INC. IS NOT RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION OR FOR RELATED SAFETY PRECAUTIONS AND PROGRAMS. CODES AND STANDARDS 1. WIND LOADS ARE PER ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, FOR A 160 MPH WIND SPEED (124 MPH NOMINAL WIND SPEED), EXPOSURE C, ENCLOSED BUILDING (+/-0.18 INTERNAL PRESSURE COEFFICIENT) AND RISK CATEGORY II 2. THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE: A. FLORIDA BUILDING CODE 7TH EDITION (2020) B. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318) C. SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301) D. MANUAL OF STD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315) E. SPECIFICATION FOR THE DESIGN, FABRICATION & ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. AMERICAN INSTITUTE OF STEEL CONSTRUCTION - (AISC) ASD/ 9TH EDITION F. BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530, 530.1/ASCE 5, 6/TMS 402, 602) 3. THE STRUCTURAL DRAWINGS ARE PART OF THE CONTRACT DOCUMENTS AND DO NOT BY THEMSELVES PROVIDE ALL THE INFORMATION REQUIRED TO PROPERLY COMPLETE THE PROJECT STRUCTURE. THE GENERAL CONTRACTOR SHALL CONSULT THE SIGNED AND SEALED PRE-ENGINEERED METAL BUILDING SHOP DRAWINGS AS WELL AS THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND COORDINATE THE INFORMATION CONTAINED IN THESE DRAWINGS WITH THE STRUCTURAL DRAWINGS TO PROPERLY CONSTRUCT THE PROJECT. 4. REFER TO ARCHITECTURAL, MECHANICAL OR ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS, DEPRESSIONS, FINISHES, INSERTS, BOLTS SETTINGS, DRAINS, REGLETS, ETC. 5. BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS TO PROPERLY SIZE OR FIT THE WORK. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED BY THE OWNER RESULTING FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT. 6. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH ANY WORK. 7. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE VERIFIED AND COORDINATED WITH THE PRE-ENGINEERED METAL BUILDING AND ARCHITECTURAL DRAWINGS BY THE CONTRACTOR BEFORE PROCEEDING WITH THE CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING BEFORE PROCEEDING WITH ANY WORK. 8. ALL DETAILS, SECTIONS AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE SHOWN. A:1Xd/_1111111wd4,1m1z144:141],tie] 1111111111101111 1. THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE THE PROPER SUBMISSION OF SPECIALTY ENGINEERED SHOP DRAWINGS WHICH SHALL BE SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ASSURE THAT THE SPECIALTY ENGINEERED SHOP DRAWINGS ARE SUBMITTED IN A TIMELY MANNER SO AS TO ALLOW REVIEWS AND RESUBMISSIONS AS REQUIRED. ALL SPECIALTY ENGINEERED PRODUCTS SHALL BE DESIGNED FOR THE APPROPRIATE GRAVITY LOADS AND WIND LOADS INCLUDING UPLIFT AND LATERAL LOADS. INTERIOR SPECIALTY PRODUCTS SHALL BE DESIGNED FOR LATERAL LOADS TO ASSURE STABILITY. FOUNDATION 1. ALL SITE PREPARATION AND EXCAVATION WORK IS TO BE PERFORMED IN STRICT ACCORDANCE WITH THE SUBSURFACE SOIL EPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION REPORT PREPARED BY ANDERSON ANDRE CONSULTING ENGINEERING, INC, DATED NOVEMBER 4, 2020 (AACA File No. 20-249) 2. BOTTOM OF FOOTINGS TO BEAR ON SOIL CAPABLE OF SAFELY SUPPORTING 2500 PSF 3. SOILS SUPPORTING ALL FOOTINGS MUST BE INSPECTED AND APPROVED BY A REGISTERED SOILS ENGINEER BEFORE COMMENCING WORK. APPROVAL IN WRITING MUST INDICATE THE SOIL IS ADEQUATE TO SAFELY SUSTAIN SPECIFIED SOIL BEARING PRESSURE. 4. BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE A MIN. OF 18" BELOW EXTERIOR FINISH GRADE. 5. ALL EXCAVATION SHALL BE KEPT DRY. EXCAVATE TO DEPTHS AND DIMENSIONS INDICATED. TAKE EVERY PRECAUTION TO GUARD AGAINST ANY MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES, UTILITIES, PIPING, ETC. 6. PROVIDE ANY BRACING OR SHORING NECESSARY TO AVOID SETTLEMENT OR DISPLACEMENT OF EXISTING FOUNDATION OR STRUCTURES. 7. CENTERLINE OF FOOTINGS: SHALL COINCIDE WITH CENTERLINE OF COLUMNS UNO 8. ALL PILES SHALL BE HELICAL ANCHOR TYPE WITH A MINIMUM ALLOWABLE TENSION CAPACITY OF 45 KIPS (ASD w/ A FACTOR OF SAFETY OF 2) CONCRETE 1. ALL CONCRETE SHALL BE READY MIX AND MEET THE FOLLOWING REQUIREMENTS: A. A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS FOR FOUNDATIONS] B. A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI @ 28 DAYS FOR SLABS ON GRADE & SHALL HAVE SRA ECLIPSE ADMIXTURE AT MINIMUM OF 1 '/2 GAL/CY C. SLUMPS SHALL BE 5 INCHES +/- 1 INCH D. CONCRETE SHALL HAVE 2% +/-1.5% ENTRAPPED AIR E. ALL CONCRETE TO HAVE MAXIMUM WATER/CEMENT RATIO OF 0.40 F. JOBSITE WATER SHALL NOT BE ADDED 2. FLY ASH AND SLAG SHALL BE LIMITED TO A MAXIMUM OF 25% OF THE CEMETICIOUS MATERIAL IN ANY CONCRETE MIX AND SHALL NOT BE USE TOGETHER. FLY ASH AND/OR SLAG SHALL NOT BEUSED UNLESS DOCUMENTATION IS PROVIDED THAT THESE PRODUCTS ARE COMPATIBLE WITH THE SRA ECLIPSE ADMIXTURE PRODUCT SPECIFIED ABOVE 3. CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS REQUIRED BY ACI SPECIFICATIONS. 4. LAP ALL BARS PER ACI MINIMUM REQUIREMENTS FOR TENSION LAP SPLICE BUT NOT LESS THAN 48 BAR DIAMETERS. LAP ALL WWF A MINIMUM OF 12 INCHES 5. ALL HOOKS SHOWN IN STEEL REINFORCING BARS SHALL BE PER ACI RECOMMENDATIONS (NOT LESS THAN 12 BAR DIAMETERS PAST BEND) LINO 6. WELDED WIRE FABRIC SHALL COMPLY WITH ASTM A185. PLACE FABRIC (OR REINF.) IN THE CENTER OF THE SLAB ON GRADE AND SUPPORT ON SLAB BOLSTERS SPACED AT X-0" O.0 7. ALL REINFORCING STEEL SHALL COMPLY WITH ASTM A615 GRADE 60 8. AT CORNERS OF CONCRETE WALLS, BEAMS, TIE BEAMS, BOND BEAMS AND CONTINUOUS WALL FOOTINGS, PROVIDE (1) MATCHING HORIZONTAL BARS X 5'-0" BENT BAR FOR EACH HORIZONTAL BAR SCHEDULED AT EACH FACE. MASONRY 1. MASONRY UNITS SHALL BE, LOAD BEARING ASTM C90 AND SHALL BE TESTED IN ACONFOMANCE WITH ASTM C140. MASONRY SHALL BE LAID IN A FULL BED OF MORTAR IN RUNNING BOND (UNO) 2. THE COMPRESSIVE STRENGTH OF MASONRY (F-M) SHALL BE 1,500 PSI AS CALCULATED IN ACCORDANCE WITH ASTM C1314. 3. ALL MORTAR SHALL BE TYPE M OR S ONLY, IN ACCORDANCE WITH ASTM C270 4. GROUT SHALL BE A HIGH SLUMP MIX IN ACCORDANCE WITH ASTM C476 AND HAVING A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AND HAVE A SLUMP OF 9" +/- 2" 5. PROVIDE HOT DIPPED GALVANIZED LADDER TYPE HORIZONTAL JOINT REINFORCEMENT (9 GA.) AT 16" ON CENTER VERTICAL IN ALL MASONRY WALLS USING PREFABRICATED CORNER AND T INTERSECTIONS. 7. PROVIDE EXPANSION JOINTS IN MASONRY WALLS AT LOCATIONS OF FLOOR EXPANSION JOISNTS. TIE BEAM AT TOP OF WALL SHALL NOT HAVE ANY EXPANSION JOINTS STEEL 1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE 9Tx Ed. OF THE AISC CODE. STRUCTURAL STEEL SHALL CONFORM TO: A. ASTM A992 GRADE 50 FOR ALL WIDE FLANGE BEAMS B. ASTM A36 FOR MISCELLANEOUS STEEL SHAPES (ANGLES, PLATES, CHANNELS, ETC.) C. SQUARE OR RECTANGULAR HSS SHALL CONFORM TO ASTM A500 GRADE B (FY=46 KSI). D. ROUND HSS SHALL CONFORM TO ASTM A500, GRADE B (FY=42 KSI). ROUND HSS WITH A WALL THICKNESS GREATER THAN 5/8, SHALL CONFORM TO ASTM A53, GRADE B (FY=35 KSI) E. ALL STEEL SHALL BE HOT DIP GAVANIZED F. ALL MILL CAMBER TO BE ORIENTED UPWARD DURING FABRICATION AND ERECTION G. STEEL BEAMS INSTALLED IN PARALLEL WITH STEEL BAR JOISTS MUST HAVE CAMBER EQUAL TO BAR JOISTS. 2. ALL WELDING SHALL BE PERFORMED BY WELDERS QUALIFIED, AS DESCRIBED IN "AMERICAN WELDING SOCIETY'S STANDARD QUALIFICATION PROCEDURE" (AWS D1.1), TO PERFORM THE TYPE OF WORK REQUIRED. 3. ALL BOLTED CONNECTIONS SHALL USE 3/4" DIAMETER, A325 HIGH STRENGTH BOLTS UNO 4. ALL CONNECTIONS SHALL BE FULL DEPTH DOUBLE CLIP ANGLE CONNECTIONS UNO (BOLTS TO BE AT 3-INCH O/C VERTICAL UNO) 5. ALL CONNECTIONS TO HOLLOW STRUCTURAL (HSS) COLUMNS ARE TO BE THRU-PLATE UNO 6. ALL ALUMINUM AND STEEL MEMBERS TO BE TREATED OR PROPERLY SEPARATED TO PREVENT GALVANIC AND CORROSIVE EFFECTS. 7. ALL ANCHOR BOLTS SHALL BE ASTM A36 THREADED ROD (OR EQUAL) DIAMETER, SPCING AND LOCATION SHALL BE PER THE SIGNED AND SEALED PRE-ENGINEERED MATAL BUILDING ENGINEERS APPROVED SHOP DRAWINGS 8. ALL STEEL WELDING RODS SHALL BE E70XX ELECTRODES (STRUCTURAL WELDING CODE - STEEL AWS D1.1) 9. SHEAR CONNECTORS TO BE HEADED STUD TYPE (BY NELSON OR EQUAL), ASTM A/108, GRADE 1015 OR 1020, COLD FINISHED CARBON STEEL, WITH DIMENSIONS COMPLYING WITH AISC SPECIFICATIONS. STEEL STAIRS ENGINEERED CONCRETE FILLED STEEL STAIR SYSTEM AND ALL CONNECTIONS OF THE SAME TO THIS STRUCTURE SHALL BE DESIGNED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA. SUBMIT SHOP DRAWINGS BEARING THE EMBOSSED SEAL AND THE SIGNATURE OF THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. THE CONFIGURATION OF THE STEEL STAIR SYSTEM SHALL BE SHOWN ON THE ARCHITECTURAL DRAWINGS. STEEL STAIR SYSTEM AND ALL CONNECTIONS SHALL BE DESIGNED FOR ALL APPLICABLE LOADS AS INDICATED ON THE PLANS AND IN ALL APPLICABLE BUILDING CODES. THE LOADS SHALL BE CLEARLY INDICATED ON ALL SHOP DRAWINGS. SHOP DRAWINGS SHALL SHOW AND SPECIFY ALL CONNECTIONS UTILIZED WITHIN THE STEEL STAIR SYSTEM AS WELL AS CONNECTIONS TO AND LOADS IMPOSED UPON THESTRUCTURAL SYSTEM SHOWN OF THESE PLANS. JOISTS 1. ALL JOISTS SHALL HAVE A SHOP COAT OF RUST INHIBITIVE NON -BITUMINOUS PAINT. 2. JOIST FABRICATOR SHALL HAVE A SPECIALTY ENGINEER REGISTERED IN THE STATE OF FLORIDA SIGN AND SEAL ALL STEEL JOIST SHOP DRAWINGS. THESE SHOP DRAWINGS SHALL CONTAIN A STATEMENT CERTIFYING THAT THE STEEL JOISTS CAN SAFELY RESIST THE WIND UPLIFT FORCES AS NOTED. 3. STEEL JOISTS SHALL BE DESIGNED, FABRICATED AND ERECTED TO THE REQUIREMENTS OF THE SPECIFICATIONS OF THE STEEL JOIST INSTITUTE FOR K SERIES. MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE. PROVIDE BRIDGING IN ACCORDANCE WITH SJI STANDARDS UNLESS NOTED OTHERWISE ON THE DRAWINGS. DECK 1. FLOOR DECK TO BE: GALVANIZED; 0.6 C (9/16") 22 GAGE FORM DECK AS MANUFACTURED BY VULCRAFT/NUCOR OR APPROVED EQUAL. FLOOR DECK MUST COMPLY WITH STEEL DECK INSTITUTE STANDARDS. ALL FLOOR DECK SHALL BE CONTINUOUS OVER A MINIMUM OF THREE SPANS. SHOP DRAWINGS 1. SHOP DRAWINGS SHALL BE SUBMITTED IN COMPLETE PACKAGES FOR THE FOLLOWING: A. CONCRETE MIX DESIGNS B. CONCRETE REINFORCING STEEL AND WELDED WIRE FABRIC C. CONCRETE MASONRY UNIT SUBMITTALS AND OTHER MASONRY ACESSORIES D. STRUCTURALSTEEL E. PRE-ENGINEERED STEEL JOISTS F. STEEL DECK. G. PRE-ENGINEERED STEEL STAIRS. H. PRE-ENGINEERED METAL BUILDINGS. 2. PRE-ENGINEERED ITEMS SHALL BE SUBMITTED SIGNED AND SEALED BY A SPECIALTY ENGINEER REGISTERED IN THE STATE OF FLORIDA HELICAL PILES 1. ALL MATERIALS USED FOR THE HELICAL PILES SHALL BE HOT DIP GALVANIZED PER ASTM A153 CLASS B-1 2. HELCAL PILES SHALL BE INSTALLED BY A QUALIFIED INSTALLER APPROVED BY THE PRODUCT MANUFACTURER (CHANCE HELICAL PILES OR APPROVED EQUAL) 3. HELICAL PILES SHALL BE SS200 AND INSTALLED BY A QUALIFIED INSTALLER APPROVED BY THE PRODUCT MANUFACTURER. 4. MATERIAL SHALL COMPY WITH THE FOLLOWING SPECIFICATIONS: A. SHAFT: ROUND-CORNERD SQUARE SOLID STEEL BAR PER ASTM A29 Fy= 90 KSI B. COUPLING BOLTS: ASTM A193 GRADE B7 HEX BOLTS (TYPE X) C. HELIX PLATES: ASTM A656 OR A1018 Fy= 80 KSI D. BRACKET BODY: ASTM A36 AND ASTM 570 GRADE 50 5. THE HELICAL PILES SHALL BE INSTALLED TO DEVELOP THE MIN. TENSILE LOAD OF: TENSION (T) = 90 KIPS (ULTIMATE) T = 45 KIPS (WORKING) 6. THE INSTALLER SHALL REVIEW THE GEOTECHINCAL ENGINEERING REPORT TO DETERMINE THE REQUIRED MINIMUM DEPTH AND/OR TORQUE NEED TO ACHIEVE THE RATED CAPCITIES INDICATED. 7, INSTALLATION SHALL BE MONITORED AND CERTIFIED BY AN INDEPENDENT ENGINEER STATING THAT THE INSTALLATION IS IN COPLIANCE WITH THE DESIGN DOCUMENTS. SUBMIT PILE LOG WITH CERTIFICATION PRIOR TO PLACING FOUNDATIONS. 8. THE CAPCITY OF THE HELICAL SYSTEM IS A FUNCTIO OF MAY ELEMENTS NOT LIMITED TO THE CAP BRACKET, PIER SHAFT, HELIXES AND BEARING STRATA AS WELL AS THE QUALITY OF PIER INSTALATION. 9. THE CAP PLATE SHALL BE WELDED TO THE HELICAL PILE SHAFT TO DEVELOP THE RATED DESIGN TENSION LOAD (FULL PENETRATION WELD) _ _A_ _A� EDGE OF SLAB O HAIRPIN BAR DETAL 3/4"=V-0" (1) #7 HAIRPIN BAR ANCHOR BOLTS BY METAL BUILDING MANUFACTURER CONCRETE COVER SCHEDULE CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 OR LARGER 2" #5 OR SMALLER 1 1 /2" CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS (#11 AND SMALLER) 3/4" BEAMS, COLUMNS (PRIMARY REINF., TIES, STIRRUPS, SPIRALS) 1 1 /2" CONCRETE FOR COASTAL CONSTRUCTION EXTERIOR CONDITIONS WALL & SLABS 2" OTHER MEMBERS 2 1/2" MASONRY WALL SCHEDULE MARK THICKNESS REINFORCING MW-1 8" CMU #5 @ 48" O.C. MW-2 8" CMU #6 @ 24" O.C. (ALL CELLS GROUTED SOLID) MASONRY WALL NOTES: 1. WALL SEGMENTS SHALL BE REINFORCED WITH 9 GA. GALVANIZED LATERAL REINFORCING @ 16" O.C. HORIZ. EXTEND REINFORCING 6" INTO POURED ELEMENTS AND AROUND ENCASED STEEL. 2. ADJACENT TO ANY EXTERIOR WALL OPENING AND AT CORNERS & WALL INTERSECTIONS, PLACE (1) SCHEDULED VERTICAL REINFORCING IN CELL GROUTED SOLID, FULL HEIGHT, U.N.O. 3. ALL MASONRY REINFORCED CELLS SHALL BE FILLED WITH 2500 PSI GROUT MIX. EDGE OF SLAB cc 2" DEEP SAWCUT (OR 1/3 x SLAB THICKNESS) WITHIN 24 HOURS OF POUR (DO NOT INTERRUPT MESH) CONTROL JOINT WIND LOAD SCHEDULE (ASD) COMPONENTS & CLADDING ROOF WIND LOADS WALL WIND LOADS (SEE NOTE 1) ROOF AREA WALL AREA 1 2 3 4 5 PRESSURE (PSF) +16.1 +16.1 +16.1 +36.2 +36.2 SUCTION (PSF) -39.5 -66.3 -99.8 -39.2 -48.2 1. EXTERIOR GLAZED OPENINGS IN BUILDINGS SHALL COMPLY WITH 7th EDITION FBC 2020 BY EITHER BEING DESIGNED FOR IMPACT RESISTANCE OR BEING PROTECTED BY IMPACT PROTECTIVE SYSTEMS. 2. CORNER DISTANCE, A = 12.5 FEET ASSUMED TRIBUTARY AREA = 10 SF MRH = 33 FEET 2x4 x CONT. WWF OR REINFORCING BARS KEY JOINT CONTINUOUS THRU CONSTRUCTION JOINT x x �p CONSTRUCTION JOINT TYPICAL SLAB -ON -GRADE NOTE: CONTROL JOINTS SHALL CREATE N.T.S. PANELS OF 625 SQ. FEET (MAXIMUM) 16" LAP IT 2'-6» BARS TO MATCH / FOOTING BARS LAP 2'-6" T (MIN.) SEE PLAN AND FOOTING SCHEDULE FOR SIZE AND REINFORCING TYPICAL STEP FOOTING DETAIL EDGE OF SLAB HAIRPIN 4" N.T.S. jp+ = i -v O HAIRPIN BAR DETAL 3 /4"=1 '- 0" HORIZONTAL JOINT REINFORCING NOT SHOWN - DISCONTINUOUS AT JOINT, TYPICAL VERTICAL REINFORCING EACH SIDE OF JOINT A A I I ® 5 I I ELEVATION PREFORMED GASKET 1/2"t BACKER BAR & CAULK JOINT EACH SIDE PLAN VIEW (MCJ) MASONRY CONTROL JOINT DETAIL Scale: N.T.S. NOTES:. 1) TIE BEAMS CONTINUOUS OVER JOINT, TYPICAL U.N.O. 2) MCJ TO ALIGN W/ SLAB EXPANSION JOINT O HAIRPIN BAR DETAL 3/4"=V-0" (1) #7 HAIRPIN BAR ANCHOR BOLTS BY METAL BUILDING MANUFACTURER 12" nHlrCr'IIV dF'1rC UC I HL 3 /4"=1 '- O" c C BEAM SCHEDULE MARK SIZE WxH (inches) REINFORCING STIRRUPS REMARKS BOTT TOP INT TIES SPACING BB-1 8 x 16 1 #5 1 #5 - _ _ MASONRY BOND BEAM BB-2 8 x 8 - - 1 #5 _ _ MASONRY BOND BEAM L-1 8F18 1 #5 1 #5 - - - PRECAST LINTEL BY CASTCRETE (SEE SECT. 1 /S3.01) FOOTING SCHEDULE IL MARK (W x x D) REINFORCING REMARKS F40 4'-0" x 4'-0" x 18" (5) #6 EACH WAY BOTT. PAD F50 5'-0" x 5'-0" x 24" (6) #7 EACH WAY BOTT. PAD F70 7'-0" x 7'-0" x 2'-6" (7) #7 EACH WAY TOP & BOTT. PAD (9) #7 SHORT WAY TOP & BOTT. & PAD W/(2) HELICAL F6080 6'-0" x 8'-0" x 2'-6' (7) #7 LONG WAY TOP & BOTT. TENSION PILES (SEE DETAILS) PAD W/(2) HELICAL F8080 8-0" x 8'-0" x 2'-6" (9) #7 EACH WAY TOP & BOTT. TENSION PILES (SEE DETAILS) (3) #5 CONT. BOTT. & TS20.12 2'-0" x CONT. x 12" #5 @ 24" O.C. TRANSV. BOTT. THICKENED SLAB (3) #5 CONT. TOP & BOTT. & TS24.24 2'-0" x CONT. x 2'-0" #3 STIRRUPS @ 16" O.C. THICKENED SLAB (3) #5 CONT. TOP & BOTT. & TS28.24 2'-4" x CONT. x 2'-0" #3 STIRRUPS @ 16" O.C. THICKENED SLAB (5) #6 CONT. TOP & BOTT. & THICKENED SLAB TS48.18 4'-0" x CONT. x 1'-6" #3 STIRRUPS @ 18" O.C. SEE 2/S6.01 TE-1 12" x CONT. x 12" (2 ) # CONT. BOTT. 5 THICKENED SLAB EDGE TE-2 12" CONT. 24" (2) #5 CONT. BOTT. & THICKENED SLAB x x (1) #5 CONT. TOP EDGE (4) #5 CONT. BOTT. & F30.14 3'-O" x CONT. x 14" #5 @ 24" O.C. TRANSV. BOTT. AT TRUCK WELL ANCHOR BOL METAL BUILD MANUFACTUR EDGE OF E CONCRETE PIER SCHEDULE 2'-0" "P-1" 24"x24" CONCRETE PIER W/(8) #6 VERTICAL & #3 TIES @ 6" O.C. V-2" 4" 0 I N O HAIRPIN BAR DETAL 3/4"=1 '- 0" a r. 65 Digitally signed by Allen Wieder, PE FL 43444 Allen Wieder, DIN: cn=Allen Wieder, PE FL 43444, o=Wieder Engineering, Inc, ou, PE FL 43444 email=awieder@wiederengineerin g.com, c=US Date: 2021.04.08 13:14:54-04'00' wieclpp �vt ineeNLl2 inc. STRUCTURAL ENGINEER 11718 SE FEDERAL HWY #373 uo #28036 (772) 546-5823 HOBE SOUND, FL 33455 FAX: (772) 545-3734 N 0 N O co 0 J Q 75 CIO D U) W a- ai U O o c N_ v CD 0 Q z 1- O w C) N 0 w L Q U) J_ Q I- LLI 0 06 ai LLI E I- z 0 � Z 0 0 o rn m m Q0 0 M CD O Q L m 'C N U �5 x z ii O m O �j (D O Q O N N z IJ . w U) CO cV I- U0 U C _ o M LL m �rn d m C'') U J U ILL N J U in LO `o -'tu- J_ O L >>o C)N N O N ' EO z ai m U � 0 N .p 0 p N ■ ■ O