Loading...
HomeMy WebLinkAboutRevisions; Proposed Lifting of Existing Residence PlansM DECORATIVE �4 END POST CAP ® 2" X 6" P.T. W001 I I TOP RAIL CAP I I 1 2" X 4" P.T. WOO I I f I I 2" X 2" P.T. WOO I PICKETS ® 51/2 MAX. 4" BETWED I I F6" X 6" P.T. WOOI I I END POST I I I I I 2" X 4" P.T. WOO I I BOTTOM RAIL �I I TYPE 2 HANDRAIL NOTE: HANDRAIL TO COMPLY WITH 2O17 FB.C. TOP RAIL - POST CAP 6"X6" END BOTTOM RAIL 4" THICK CONC. SLAB MIN. 9.04' N.G.VD. v- - 2" X 2" X 1/4" ALUMINUM TUBING - FOR WALL MOUNTED BRACKET PROVIDE 1/4" TAP CONS 0 6" O.C. INTO CBS. WALL EXISTING GRADE — 1/2°' = 19-0" WOOD FLOOR JOIST WOOD BEAM (1) MTSM16 WITH (8)10d NAILS ---� AND (4) 2 1/4" TAPCONS 0 EACH COLUMN OR HETA16 SET IN POUR WITH (6)10d NAILS TO WOOD BEAM 12" X 12" C.B.S. COLUMN 3 COURSES HIGH WITH (2) #5 BAR POURED SOLID WITH 3000 PSI. CONCRETE DOWEL & EPDXY (2) #5 BAR MIN. 6" EMBED INTO FDOTER 24" W. X 24" W. X 12" D. COLUMN PAD #5 BARS @ 8" (EACH DIRECTION) 2" X 6" P.T. WOOD TREADS 2" X 12" P.T, WOOD STRINGER A.C. COMP. 4" CONC, SLAB 8" X 16" CONC. BLOCK— �VISQUEEN VAPOR BARRIER FINISH GRADE pl ``-----THICKENED SLAB EDGE 8" WIDE X 8" DEEP WITH (1) #5 BAR CONC, FILLED CELLS W/ 1 # 5 BAR HOOKED TO FOOTING & " STEM WALL FTG. 24" WIDE HOOKED TO THK'D SLAB EDGE ° " X 12" DEEP WITH (3) #5 BARS IW*m ' - , i #5 DOWELS ® 8' O.C. #4 BAR ® NOSING V�s " a s s s 8" X 12" THICKENED SLAB WITH (2) #5 BARS 97 ; 4" CONC. SLAB VISQUEEN VAPOR BARRIER THICKENED SLAB EDGE 8" WIDE X 8" DEEP WITH (1) #5 BARS >TEM WALL FTG.24" WIDE X 12" DEEP WITH (3) #5 BARS EXISTING ROOF TRUSSES EXISTING HURRICANE STRAPS \ \ 1 --------- ---- - -- - -- Gk. --------- -------- - - - - -- 1 �\ EXISTING FASCIA & DRIP EDGE I II I II I EXISTING CONCRETE BEAM I " I F, II- I r-EXISTING 8" X 8" X 1V CBS WALL I II I I-"- I �rb I CUT LINE 0 EXISTING CBS WALL . NOTE: THE WHOLE HOUSE IS BEING RAISED & WITH A NEW FLOOR 2" X 12" P.T. LEDGER ANCHORED TO CONCRETE WALL 5/8" SLEEVE ANCHORS 0 48" O.C. 3/4" T&G SUB -FLOOR ON 2" X 12" JOIST 0 16" O.C. SET N JOIST HANGERS PROVIDE R-3D BATT INSULATION IN FL. SYSTEM SIMPSON LUS210 AT EA. JOIST -W- 2" X 12" SHORING UNDER LEDGER TAP CONCS TO CBS WALL (SEE PLAN FOR LACTIONS) EXISTING CONCRETE SLAB & FOUNDATION TO REMAIN DOWEL & GROUT (1) #5 BAR INTO EXIST, POURED CELL AT EXISTING POURED CELL LOCATIONS NEW 8" X 16" CONC. BLOCK WALL WITH (1) #5 BAR AS PER PLAN NEW FINISH FLOOR 1125' NAND, BASE FLOOD (AE 9) 9A' NAND. EXISTING GRADE EXISTING FINISH FLOOR -- ; 7.92' NAND. DOWEL & EPDXY (1) #5 BAR MN. 6" EMBED INTO EXIST. POURED CELL EXISTING FOOTER TO REMAIN SHEETINDEX 1 NOTES & DETAILS 2 FOUNDATION PLAN 3 FRAMING PLAN PROJECT INFO, SITE ADDRESS: 3695 AVE, FT. PIERCE, FL PROJECT ENGINEER: JOSEPH P. McCARTY PROJECT CONTRACTOR: BROWNIE COMPANIES LLC DESIGN CRITERIA FLORIDA BUILDING CODE: 2020 EDITION JURISDICTION: CITY OF FT. PIERCE, FLORIDA ULTIMATE DESIGN WIND SPEED: 160 M.P.H. NOMINAL DESIGN WIND SPEED: 124 M.P.H. OCCUPANCY CATEGORY: I I (RESIDENTIAL) MINIMUM SOIL BEARING PRESSURE: 2500 P.S.F. NOTE• 1. RELOCATION CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE BEGINNING WORK. 2. THIS FOUNDATION PLAN IS FOR RAISING AND OR RELOCATING STRUCTURE. LOCATION OF ALL INTERIOR FOOTERS, PIERS AND SUPPORTING WALLS MAY VARY AND CAN BE PLACED AT THE PROPER POSITION AT THE ENGINEERS DISCRETION AFTER THE STRUCTURE IS ELEVATED TO DUPLPATE EXISTING LOCATIONS OF SUPPORTS, AS WELL AS ADD ANY ADDITIONAL c3UPPORTS DEEMED NECESSARY. 3. NOTE, ANY OTHER RENOVATIONS TO THE STRUCTURE OTHER THAN WHAT IS SHOWN ON THE SUBMITTED PLANS WILL NEED TO BE PERMITTED SEPARATELY. NOTE: THIS PROJECT IS AN ALTERATIONS - LEVEL 3 ACCORDING TO F.B.C. FOR EXISTING BUILDING CHAPTER 7. THE SCOPE OF WORK DOES NOT REDUCE THE STRUCTURAL STRENGTH OR STABILITY OF THE BUILDING. THE NEW STRUCTURAL MEMBERS IN THE ALTERATIONS DOES COMPLY WITH THE F.B.C. 2020 RE�E EOD OR , CODE COMPLIANCE GENERAL NOTES: ST. LUCIE BoCC UNTY THIS OCCUPANCY SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES, WHETHER IMPLIED OR NOT IN THIS SET OF BUILDING PLANS ALL LUMBER IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRESSURE TREATED ALL STRUCTURAL FRAMING TO BE HEM FIR #2, SPF #1, SOUTHERN PINE #2 OR APPROVED ALTERNATE W/ fb=1000 P.S.I. MIN. - NON -STRUCTURAL FRAMING MAY BE SELECTED SPECIES - "STUD" GRADE DESIGN AND CONSTRUCTION OF ALL ELEMENTS CONCERNING THIS PLUMBING INSTALLATION, SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THE STANDARD PLUMBING CODE, AS WELL AS THE LOCAL AMENDMENT TO THE STANDARD PLUMBING CODE. CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AVAILABLE AT SITE BEFORE PROCEEDING W/ CONSTRUCTION LcI nu • a r — - w A � N .—IIII III U rn Q� d � cr o� 1-0 Q J z o w o ® o lit o::D cr_ !— ) Cn 04 0. DRAWN BY R.C. DATE 26 MAR 19 7MAY 19 2 JULY 19 11 FEB 2021 27 MAR 2021 1/2" _ 19-0" 1/2" ® 1'-On 48'00 EXISTING CBS. RESIDENCE 210" - 11O0" � 2'0' NEW CONCRETE PATIO EXISTING CBS. RESIDENCE I I vi 0 a PROVIDE (8) - 8" X 16" ENGINEERED FLOOD VENTS 8 " X 160181FLOOD VENT ODEL 6CS AS PER CODE (SEE LOCATIONS ON PLAN) 205 SQ. OFCOVERS HOUSE SQ. IFT. l — 2,820 SQ. FT. (FOUNDATION) / 205 SQ, FT. PER FLOOD VENT = 14 FLOOD VENTS REQUIRED 14 FLOOD VENTS PROVIDED NOTE: THE DESIGN OF THE OPENINGS WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWING FOR THE AUTOATIC ENTRY AND EXIT OF FLOODWATERS AS PER THE 2017 F.R.B.C. F— — — — — — — — — — I] oi IQL— IEII 13 Ell El 6'0 1 Fr (3000 PSI. CONCRETE) I I 3D 4' THICK CONC, SLAB WITH 6" X 6" 10/10 W.WF. WITH CHAIRS TO LOCATE MESH IN TOP HALF OF SLAB I OVER VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE I p I I TREATED SOIL(25DO PSF. SOIL) I I I I I I I I rEll I Ho 4'6' I 7'1* 1 — V(-- 5'gr INDICATES 8" X 16"— OPENING IN WALL FOR VENTILATION. VENT COVERS BY OTHERS. 8,00 32'0" 810. NEW CONCRETE PATIO NEW CONCRETE PATIO r- — — — — — — 1 0 E]l 101 IE3 I El CL w 8 NEW CONCRETE STAIRS SEE DETAIL SHEET #1 C X 16" CONC. BLOCK STEM WALL --- WITH (1) #5 BAR AS PER PLAN lwjI — — — — — — — — — — — — — — — — — — — - El Ell Ig flini) JEII Eol 0 - - --- - - - - - - - - - - - - --- - - - - - - - --- - - - - - - - --- - - - - - - - - (3000 PSI. CONCRETE) 4!'THICK CONC. SLAB WITH 6" X 6" 10/10 WNF. WITH CHAIRS TO LOCATE MESH IN TOP HALF OF SLAB OVER VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED SOIL (2500 PSF. SOIL) - L loll IIDI B'o" 7'4" 48" 7'0' 1,13" 6 4!0" 54" 34 k 7-8- x ' DOWEL & GROUT (1) #5 BAR DOWEL lk 'k Po L INTO EXIST, POURED CELL L EXISTING POURED CELL LOCATIONS T EXISTING POUR CELL :4- "I p vi cp 32" X 32" ALUMINUM ACCESS DOOR AS PER FBC. R408.4 Iii NOTE: STEEL DOOR FRAME 5? CAN BE USED AS A HEADER AND NO LINTEL IS REQUIRED. R —MR-0— It 7'10` 7'10" EXISTING CONCRETE SLAB & FOUNDATI IN TO REMAIN 7 f — — — Fl 3' DOWEL & GROUT (1) #5 BAR INTO EXIST. POUTED CELL ' AT EXISTING POURED CELL LOI, DNS ATI I--- 113'1 x r 4 IV, �i 1/4" = IP-00 FOOTING SCHEDULE FOOTING SIZE RE - BAR SIZE & QUANTITY FOOTING TYPE A 30" W. X 30" k X 12" D. #5 BARS @ 8" (EACH DIRECTION) COLUMN PAD B 24" W. X 120' D. (3) #5 BARS STEM WALL LLLJJ I I �t)I I ® IiL=jj I LL j I 00 IIr - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Ell 117I 101 1E] El 6!0" - - - - - - - - --- - - - - - - - --- - - - - - - --- - Z EXISTING CONCRETE SLAB & FOUNDATION TO REMAIN 7 -El Z EXIS LING CONCRE f SLAB & FOUNDATION TO REMAIN �® 01 7 s — 1 FE�l I® *:q- lb — — I n (3000 PSJ. CONCRETE) 10'20 VOO L 104" VON 104" Ll'O' L 510" 810"— l'o" 8,100 4" THICK CONIC. SLAB WITH 6" X 6" 10/10 WWF. WITH CHAIRS TO LOCATE MESH IN TOP HALF OF SLAB I OVER VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED SOIL (2500 PSF. SOIL) DOWEL & GROUT (1) #5 BAR INTO EXIST. POURED CELL AT EXISTING POURED CELL LOCATIONS 2-8- 10'0" VO4 46" 14" 7-4- B'O" I IO'o" 4!0" 54" — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — WITH CHAIRS TO LOCATE MESH IN TOP HALF OF SLAB I (3000 PS1. CONCRETE) 4" THICK CONC. SLAB WITH 6" X 6" 10/10 WWF. OVER VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE IIDI IECI TREATED SOIL (2500 PSF. SOIL) 7 Ir ---------------- mT ----------------------------------------------------------------- I I L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - __________I I 0 El B" X 160 CONIC. BLOCK WALL - EIj Ell 11211 IEII 1 19 El I @ WITH (1) #5 BAR AS PER PLAN I IE1I1I L— — — — — — — — — — — — — — — — — — — — — — -- -- — — — — ::I— — — — — — — — — — — — — — — — — — — — @ 80 X 160 CONC. BLOCK STEM WALL WITH (1) #5 BAR AS PER PLAN 32'00 34'4" NEW CONC. PORCH NEW CONC. WALKWAY cr 71'4" 21'2" EXISTING CBS. RESIDENCE EXISTING GARAGE / NEW CONC, STEM WALL I I--- m V) -0 E D cn 3 LIJ, < ci LLJ CD o cn CD cn c1f, c) eD Im I DRAWN BY R.C. DATE 26 MAR 19 REVISIONS 7 MAY 19 2 JULY 19 11 FEB 2021 27 �R2121 2 4FFT CONNECTOR SCHEDULE ID. MFG'R MODEL NO. FASTENERS UPLIFT LATERAL F1 / F2 DOWN LOAD STRUCTURE HEADER / FACE JOIST / TRUSS 1 SIMPSON MTS16 EMBED 8 — 10d 1 Poo -- 2 3 SIMPSON LUS210-2 -- 6 — 16d 4 — 16d 1 65 -- 1 315 4 SIMPSON-t77DUS210 6 - 10d 4 - 10d 1 65 36" HT. RAILING — DBL. 2 X 10" P.T. WOOD RIM BEAM (1) MTSM16 WITH (8)10d NAILS AND (4) 21/4' TAPCONS 0 EACH COLUMN OR HETA16 SET IN POUR WITH (6)10d NAILS TO WOOD BEAM 12" X 12" CBS. COLUMN 4 COURSES HIGH WITH (2) #5 BAR POURED SOLID WITH 3000 PSI. CONCRETE DOWEL &EPDXY (2) #5 BAR MIN. 6" EMBED INTO FOOTER 24" W. X 24" W. X 12" D. COLUMN PAD #5 BARS 0 8" (EACH DIRECTION) -. _ A. 1 A 1: u f- C IMP DRAWN BY R.C. DATE 26 MAR 19 REVISIONS 7MAY 19 2 JULY 19 11 FEB 2021 27 98 sj SHEET #