Loading...
HomeMy WebLinkAboutPA FL16994-R6Florida Building Code Online 1122J21, 9:58 AWN �,.13R11F�2iMl1�4' �. ssional Regulation o�,S P't�'�HgNF. iri' ➢BA'H� oSi�k oIVldFrk;Iri i b,p Product Approval d.r � USER:Public user Prod uct Approval hLemt PDAuc[�[9nnit[aYion Sear > Aanlicat 0n_Li�y > Application Detail FL 4 Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Suhcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL15994-R6 Revision 202❑ Approved Southeastern Metals Mfg. Co. 11801 Industry Drive IacksonviIle, FL 32218 (904) 696-4682 j hkelsey@semetaIs,com ]eremy Kelsey j hkeisey@semetals, cam Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Zachary R. Priest PE-74021 UL LLC 12/20/2023 Steven M_ Urich, PE Validation Checklist - Hardcopy Received FL16994 R6 CO1 SEM1400 .5a 2020 F13C Eyal_Off- gidge vent f riai.prlf https://www.floridabuild!ng.orglpr/pr_app_dti.aspx?param=wGEVXQwtDgvBwYugTr7Nm4u1g03EalhUyA3HWjfCFjF%2frNZE9go"YQ%3d%3d Page 1 of 2 Florida Building Code Online Sections from the Code 1t22121, 9:68 AM 1503.5 1709.2 Product Approval Method Method 2 Option B Date Submitted 08/11/2020 Date Validated 09/01/2020 Date Pending FBC Approval 09/20/2020 Date Approved 12/15/2020 Date Revised 12/17/2020 5ummary of Products FL # Model, Number or Name Description 16994.1 Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FLi6994 R6 1I SEM14001.6a 2020 FSC Eval Off -Ridge Vent final.qdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-18 Created by Independent Third Party: Yes other: See Evaluation report for limits of use. Evaluation Reports FL16294 K6 AL M 40 1. a 02 FB Ri ge Vent Frtal. pdf Created by Independent Third Party: Yes 16994.2 Tile Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete tile Limits of Use Installation instructions Approved for use in HVHZ: No F 1 6994 R6 11 M 14001.5b 2020 FD EvaI Til f V final.adf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-9 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports FL15494_r�A�_SEM14001..6h9Q_F13C_val Tile Roof Vent Lapa Created by Independent Third Party: Yes sack Contact Us :: ZOO L 314W Stone II F Phone: 850,-4{ 7-1824 The State of Florida is an AA/FEO employer. Copyriotit 2007-2613 State of Florida.:: Privacy 50tement :: Accessibility Statement!! ent Under Florida law, email addresses are public records. If you do not want your a -mail address released In response to a Pull records request, do not send electronic mail to this entlty. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 85n.487A395. *Pursuant to Section 455.275(1), Florida Statutes, etfecl October 1, 2012, Ilcensees licensed under Chapter 455, F.S. must provide the Department with an emali address If they have one. The email& provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a Personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . P '1d L ARP"­1 Accapb• Credit Card Safi' httpsillwww.floridabuilding.org/prlpr_app-dti.aspx?param=wGEVXQwtDgvBwYu9TrZNm4ulqD3EalhUyA3HWjfCFjFOA2frN2E9gOnyQ%3d%3d Page 2 of 2 EVALUATION REPORT Certificate of Authorization No. 29824 17520 Edinburgh Di Tampa, FL 33647 (813) 480-2421 FLORIDA BUILDING CODE, 7" EDITION (2020) Manufacturer: Southeastern Metals Manufacturing Co., Inc. (SEMCO) 11801 Industry Drive Jacksonville, FL 32218 (800)874-0335 httl3J/www_semetals. com Manufacturing Plant: Jacksonville, FL (duality Assurance: UL LLC (QUA9625) SCOPE Category: Subcategory: Code Sections Properties: REFERENCES Issued August 11, 2020 Roofing Roofing Accessories that are an Integral Part of the Roofing System 1503.5, 1709.2 Roof Ventilation 1=ntity PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) Zachary R. Priest, P.E. (CREEK Technical Services) PRODUCT DESCRIPTION Report No_ Standard Year SEM-029-02-01 ASTM E 330 2014 SEM-031-02-01 ASTM E 330 2014 SEM14003 Calculations 2014 Off Ridge Vent: Minimum 26 ga. ASTM A792 or ASTM A653 CS Type B steel-, Shall conform with FBC Section 1503.2 Maximum dimensions of the vent are 24-inch wide x 102-inch long x 4.25-inch high. Vent is available in nominal 4-ft, 6-ft and 8-ft sizes. SEM14001.6a FLi&994-R6 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3- The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Go., Inc. Nook& COff Ridge Vent �''� K Im E l-, TECHNICAL SERvicEs, L.L PRODUCT APPLICATION Deck Type: Minimum 7116-inch APA span rated OSB sheathing or 15132-inch APA span rated plywood sheathing for new and existing roof deck (Deck shall be designed by others in accordance with FBC requirements). Roof slope: Minimum 2,12 Installation Height: Maximum 33-ft Roof Cut -Out: 2.5-inch wide x 42-inch opening for the nominal 4-ft vent 2.5-inch wide x 66-inch opening for the nominal 6-it vent 2.5-inch wide x 90-inch opening for the nominal 8-ft vent Attachment Method: Cut-out opening as prescribed above into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. in - Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM ❑ 4586 or ASTM D 3409, Type I roofing cement/mastic to the underside of the perimeter flange to continuously surround and seal the flange. Position the vent over the opening in the roof sheathing. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with #9 x min. 1.5-inch HWH screws with 0.5-inch sealing washers or min. 12 ga. x 1- 1/4-inch ring shank nails with min. 3/8-inch diameter heads having sufficient length to penetrate through the sheathing a minimum of 318-inch. The fasteners shall be located 1- inch from the edge of the flange and 5.5-inches o.c. along all four sides of the vent. All loosened shingles shall be adhered down with roof cement/mastic. When nails are used to attach the vent, all penetrations through the vent flange shall be sealed using ASTM D 4586 or ASTM D 3409, Type 1 roofing cement/mastic. Viv 1 rih in ��/�� � f�� f , r . r i1•ta Allowable Roof Asphalt shingles Coverings: Maximum Design -13.5 psf for 4-ft and 6-ft vents Pressure -18 psf for 8-ft vent Pressures cafculated using 2:1 margin of safety per 1504.9 5FM14001.62 FL16994-R6 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify GREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specificaliyaddressed herein_ Southeastern Metals Manufacturing Co., Inc. Off Ridge Vent E NE"'K TECHNICAL EP-RVIC , , LLC LIMITATIONS 1) This report is not for use in the HVHZ. 2) Fire Classification is outside the scope of this evaluation. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) SEMCO vents shall he installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) lnstallation of the roof assembly is outside the scope of this evaluation. 7) SEMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R_ Priest, P.E. have demonstrated compliance with the Florida Building Code, 70 Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. rr►rru rrrer,jfr R. P�'!� �� G E tv s� S. f: No 74021 Q: STATE OF 41r►` J#�,ir yC? N A� E �;•t`�• CERTIFICATION OF INDEPENDENCE 2020.08.11 14:2 2 :5 5 -041001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LL.0 does not have, nor will it acquire: a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. .Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT SEM14001.6a FLi 6994-R6 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.