HomeMy WebLinkAboutAPPROVED Dijoy-Metal Alliance FL Approval.pdfBCIS Home Lag In User Registration db,pr +) Product Approval Ik USER: Public User Hot Topics Submit Surcharge Stars S Facts Publications Contact us SCIS Site Map links Search Product Approval Menu > Product or Apalicatwn Search > Aggllcatiun List > Application Detail FL # FU9523-RS Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Metal Alliance Inc. 2120 SW Poma Dr. Palm City, FL 34990 J 4444) 638-254_Q orders@metalalliance.com Tara Faulkner orders@metalalliance.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received David Eng PE-81377 Keystone Certifications, Inc. 04/22/2030 James R Wally, PE Validation Checklist - Hardcopy Received FL29523 RI COI 32AI 1005L_plywood nonHVHZ.pdf Standard Year TAS 100 1995 TAS 125 2003 UL580 2006 Ilps:fjfloridabuilding.orgjprlpr_app_dtl.aspx?param=wGEVXQwtDquDIJZOKCH08euJlR2VS4wAPLbCuLWfBsMgrM4sxtfrSA%3d%3d 4115121, 1:31 PM Page 1 of 3 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/11/2020 08/13/2020 08/19/2020 10/13/2020 FL s Modelr Number or Name Description 29523.1 01: 100SL I" Nailstrip 032 100SL 1" Nailstrip panel from nominal 0.032" aluminum or Aluminum thicker on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL29523 Rl-ll_32AI 1005E olvwood nonHVHZ.odf Verified By: David Eng, PE 81377 Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Created by Independent Third Party: Yes Evaluation Reports Other: 168.5 psf @ 6" oc FL29523 1 AE 32AI 100-1 plywood nonHVHZ.odf Created by Independent Third Party: Yes 29523.2 02: 100SL 1" Nallstrip 24ga 100SL 1" Nallstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank Installation Instructions Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL29523 R1 11_24aa 100SL plywood nonHVHZ odf Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-206 Evaluation Reports Other: 206 psf @ 6 " oc FL29523 Rl AE 24ga 1005L plywood nonHVHZ odf Created by Independent Third Party: Yes 29523.3 03: 100SL 1" Nailstrip 269a HVHZ IOOSL 1" Nallstrip panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL29523_R1 II 26ga 1005E olvwood odf Verified By: David Eng, PE 81377 Impact Resistant: N/A Design Pressure: +N/A/-176 Created by Independent Third Party: Yes Evaluation Reports Other: 176 psf @ 6" oc WITH sealant, 116 psf D 6" oc FL29523 R3 AE 26ga 100SL olvwood odf without sealant Created by Independent Third Party: Yes 29523.4 04: 100SL 1" Nallstrip 032 100SL 1" Nailstrip panel from nominal 0.032" aluminum or Aluminum HVHZ thicker on 15/32" (min) plywood or 3/4" (min) wood plank Installation Instructions Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL29523 R1_II 32AI 1005L plywood-12 Verified By: David Eng, PE 81377 Impact Resistant: N/A Design Pressure: +N/A/-175 Created by Independent Third Party: Yes Evaluation Reports Other: 175 psf @ 6" oc WITH sealant FL29523 RI AE 32AI 1005L plywood odf Created by Independent Third Party: Yes 29523.5 _ 05: 150SL 1.5" Nallstrip 24ga 150SL 1.5" Nailstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank Limns of Use Installation Instructions Approved for use in HVHZ: No FIFI 29529 Ri II 24ga 1505E olvwood nonHVHZ odf Approved for use outside HVHZ; Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: 153.5 psf @ 6" oc WITH sealant Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523 R1 AE 24oa_15051plywood nonHVHZ ndf Created by Independent Third Party: Yes 29523.6 06: 150SL 1.5" Nailstrip 032 Aluminum 150SL 1.5" Nallstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions h11p5:pf1ondanu0dir;q,pr9/Dr/pr_a Dp dtl.aspaloaram_wGEVXOw1DquDIJZOKCHOB: ',I4,x1frSA%3d%3d 4j15,1 1.31 FU Page 2 of 3 A& METALALLIANCL A Value Added Supplier of Metals 1" NailStrip 24ga Steel Panels 24ga (min) 1" Nail Strip over 15/32" (min) plywood Metal Alliance, Inc 2120 SW Poma Dr I Palm City FL 34990 Produced by Metal Alliance's Network of Approved Regional Manufacturers Product Description Nailstrip, snaplock style panel with a 16" maximum panel width and a nominal rib height of 1" Product Material 24ga (min) steel 24ga is nominally 0.0239" with yield strength of at least 50ksi, and shall be corrosion resistant per FBC 1507.4.3 where required. Fastener #10 1-inch pancake style fastener Compliant with FBC 1506.6 where required. Substrate/Deck 15/32" (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 www.TimberLakeCove.com ���llnlliri Qp`.•�`CENS,F No. 81377 Pj 100SL FL29523.02-R1 Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope: Comply with local building code or FBC 1507.4.2 where required. Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Maximum Allowable Loads & Installation Requirements: Method A• #10 x 1" fastener at 6" O.C.along nail strip- 206 PSF A factor of safety of 2 has been applied. Fasteners are installed through the metal flange, NOT through the pre -punched slots. Technical Documentation: This product has been tested to the UL 580 standard by Intertek Testing (TST-1527), report J6368.05-450-44 RO. Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The some entities do not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. METALALLIANLt A Value Added Supplier of Metals 100SL FL29523.02-R1 Instructions: Select the appropriate load table that applies to the structure in question. Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within each roof zone. NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken for each zone and reported using the standard zones 1-2-3: Zone 1 includes zones 1 and 1' Zone 2 includes zones 2e, 2r, and 2n Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple scheme, at the expense of some design efficiency. Contact Metal Alliance Inc for further information, or consult a licensed design professional. Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof, or gable/hlp roof with max slope of 46° Have either a flat roof, or gable/hip roof with max slope of 45' Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL29623.02: 24aa 100SL 1" nail strip on 16/32" plywood FL29623.02: 24 a 100SL 1" nail strip on 16/32" olvwood Wind 106 110 120 130 140 150 160 170 180 190 200 Wind 106 110 120 130 140 160 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A I Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 7', hip roof with Have either a flat roof less than 7°, hip roof with max slope of 45°, or gable roof with slope between 20° and 46° max slope of 46°, or gable roof with slope between 200 and 450 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL29523.02: 24na 100SL 1" nail strip on 16/32" P1 ood FL29623.02: 24 a 100SL 1" nail strip on 15/32" 1 ood Wind 105 110 120 130 140 160 160 170 180 190 200 Wind 106 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A A 5 A& METALALLIANCE -f _ A Value Added Supplier of Metals r METALALLIANCE A Value Added Supplier of Metals 1" NailStrip 24ga Steel Panels 24ga (min) 1" Nail Strip over 15/32" (min) plywood Metal Alliance, Inc 2120 SW Poma Dr I Palm City FL 34990 Produced by Metal Alliance's Network of Approved Regional Manufacturers Product Description Nailstrip, snoplock style panel with a 16" maximum panel width and a nominal rib height of 1" Product Material 24ga (min) steel 249a is nominally 0.0239" with yield strength of at least 50ksi, and shall be corrosion resistant per FBC 1507.4.3 where required. Fastener #10 1-inch pancake style fastener Compliant with FBC 1506.6 where required. Substrate/Deck 15/32^ (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 www.TimberLakeCove.com 100S L• l" NAI LSTRI P 24GA �tiin Ilt,,,� � Q •'•�1GENSR '•.�i No. 81377 .� 41 STATE OF ��� David E Eng �- 2020.08.10 18:45:33-04'00' This Rem has been digitally signed and sealed by D.E. Eng. PE, on the date indicated Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 100SL FL29523.02-R1 Underlayment: comply with local building code or FBC 1507.1.1 where required Slope: Comply with local building code or FBC 1507.4.2 where required. Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Maximum Allowable Loads & Installation Requirements: Method A• #10 x 1" fastener at 6" o c along nail strip 206 PSF A factor of safety of 2 has been applied. Fasteners are installed through the metal flange, NOT through the pre -punched slots. Technical Documentation: This product has been tested to the UL 580 standard by Intertek Testing (TST-1527), report J6368.05-450-44 RO. Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. 01 METAULLIANCE A Value Added Supplier of Metals 100SL FL29523.02-R1 Instructions: Select the appropriate load table that applies to the structure in question. Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within each roof zone. NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken for each zone and reported using the standard zones 1-2-3: Zone 1 includes zones 1 and 1' Zone 2 includes zones 2e, 2r, and 2n Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple scheme, at the expense of some design efficiency. Contact Metal Alliance Inc for further information, or consult a licensed design professional. Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof, or gable/hip roof with max slope of 450 Have a mean Roof Height of 30 feet or less Use this load table for structures which meet the following criteria. Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 460 Have a mean Roof Height of 30 feet or less FL29523.02: 24aa 100SL 1" nail strip on 16/32" plywood FL29523.02: 24ga 100SL 1" nail strip on 15/32" plywood Wind 105 110 120 130 140 160 160 170 180 190 200 Wind 105 110 120 130 140 160 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 70, hip roof with Have either a flat roof less than 7°, hip roof with max slope of 45°, or gable roof with slope between 200 and 450 max slope of 46°, or gable roof with slope between 20' and 46° Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL29523.02: 24ga 100SL V nail strip on 15/32" Plywood FL29623.02: 24ga 100SL 1" nail strip on 16132" pi od Wind 106 110 120 130 140 160 160 170 180 190 200 Wind 106 110 120 130 140 160 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zane 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A , A A A A A Zane 3: A A A A A A A A A A METAL ALLIANCE A Value Added Supplier of Metals