HomeMy WebLinkAboutAPPROVED GAF LEAK BARRIERS MIAMI C]�ADE� MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Sheet,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 3 3 1 75-2474 T(786)315-2590 F(786)315-2599 evw .In wiartucladi go%,/ccouoiiiy NOTICE OF ACCEPTANCE (NOA) � .. GAF I Campus Drive Parsipanny,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revolve,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code, This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Leak Barriers and Roof Deck Protection LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 18-0119.15 and consists of pages I through 8. The submitted documentation was reviewed by Jorge L. Acebo. • NOA No.: 18-1023.10 MIAMI-DADECOUNTY � Expiration Date: 02/22/23 a y Approval Date: 05/09/19 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS/Polypropylene/Asphalt SCOPE : This approves GAF Leak Barriers and Roof Deck Protection underlayments, to be used on existing roof assemblies as described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code, PRODUCTS DESCRIPTION : Test Product Product Dimensions Specification Description WeatherWatch° 36" x 50' rolls ASTM D1970 Granular surfaced modified, fiberglass reinforced, Mineral Surfaced Leak 36" x 66.7' rolls bituminous sheet material for use as a leak barrier Barrier underlayment in sloped roof assemblies. Manufacturing Designed as an ice & rain shield. Location # 1, 8 StormGuare Film 36" x 66.7 ' rolls ASTM D1970 Modified, fiberglass reinforced, bituminous sheet Surfaced Leak Barrier material for use as a high temperature leak barrier Man¢tfacturing underlayment in sloped roof assemblies. Location # 1 , 8 Designed as an ice & rain shield. Liberty"' SBS Self- 39%" x 66 ' rolls ASTM D 1970 Self-adhering SBS roof membrane. Adhering Base/Ply ASTM D4601 Sheet Type II Manufacturing Location # 1, 8 Deck-Armor" Premium 54" x 222' rolls ASTM D226 A UV-stabilized polypropylene breathable Breathable Roof Deck 48" x 250' rolls Type II underlayment. To be used for roof deck Protection 48" x 100' rolls protection as an underlayment in sloped roof Mum factoring assemblies. Location # 7 Tiger Paw"' Roof Deck 48" x 250' rolls ASTM D226 A UV-stabilized polypropylene non-breathable Protection 48" x 100' rolls Type lI underlayment. To be used for roof deck protection Manufacturing as an underlayment in sloped roof assemblies. Location # 2, 4, 5, 7 NOA No.: 184023.10 MinMi•ono couNrr Expiration Date: 02/22/23 e Approval Date: 05/09/19 Page 2 of 8 I i i i i PRODUCTS DESCRIPTION. Test Product i Product Dimensions Specification Descriptlon FeltBusterl High- 48" x 250' rolls ASTM D226 A UV-stabilized polypropylene non-breathable Traction Synthetic Type II underlayment. To be used for roof deck protection Roofing Felt as an underlayment in sloped roof assemblies. Manufacturing Location # 6, 7 Shingle-Mate® Roof 36" x 144 ' rolls ASTM D226 Fibergass-reinforced asphalt felt underlayment. To Deck Protection Type I be used for roof deck protection as an j Manufacturing underlayment in sloped roof assemblies. Location # 3 Liberty"' SA Glass Cap 39 3/s" x 34' rolls ASTM D1970 Granular surfaced modified, fiberglass reinforced, Sheet ASTM D6163 self-adhering SBS roof membrane. Manufacturing ASTM D7530 Location # 8 GAFGLAS® Ply 4 39.37" ASTM D2178 Asphalt impregnated glass felt with asphalt Manufacturing ( 1 meter) Wide Type IV coating. Location # 8, 9, 10 GAFGLASo FlexPIyT" 6 39.37" ASTM D2178 Asphalt impregnated glass felt with asphalt Manufacturing ( 1 meter) Wide Type VI coating. Location # 8, 9, 10 Tri-Plyo Ply 4 39,37" ASTM D2178 Asphalt impregnated glass felt with asphalt Mmnefkc•turing ( 1 meter) Wide Type IV coating. Location # 8, 9, 10 MANUFACTURING LOCATION: 1 . Mt. Vernon, IN 2. Mission, British Columbia 3. Pryor, OK 4. Qingdao, China 5. Charleston, SC 6. Spartanburg, SC 7. Dadra, India 8. Savannah, GA 9. Mobile, AL 10. Fontana, CA NOA No.: 18-1023.10 MIAMI•DADE COUNTY Expiration Date: 02/22/23 Approval Date: 05/09/19 Page 3 of 8 i i EVIDENCE SUBMITTED : Test Aaeney Test Identifier Test Name/Report Date Intertek Testing Services NA Ltd. 3077464-01 ASTM D1970 08/23/06 3090131 Wind Uplift and Self Sealability 08/23/06 100258583COQ-010A ASTM D226 Type II 01/ 11 / I1 100673818COQ-003 ASTM D226 Type II 06/13/ 13 10157289000Q-005 ASTM D226 Type 11 04/ 17/ 14 F8549.02406- 18-RO ASTM D226 Type II 11 /08/ 16 PRI Construction Materials RGM-023-02-01 ASTM D4798 05/ 16/07 Technologies, LLC. GAF- 112-02-01 ASTM D226 Type Il 03/15/06 GAF-238-02-01 ASTMD1970 03/03/ 10 GAF-323-02-01 ASTM D1970 11 /30/ 11 GAF-324-02-01 ASTM D1970 11 /30/ 11 GAF-325-02-01 ASTM D1970 11 /30/ 11 GAF-326-02-01 ASTM D1970 11 /30/ 11 GAF-275-02-01 ASTMD1970 11/ 11 / 10 GAF-344-02-01 ASTM D1970 04/23/12 GAF-339-02-01 ASTM D226 Type I 03/ 14/ 12 ELK-311 -02-01 ASTM D1970 09/ 11/07 GAF-446-02-01 ASTM D226 Type I 09/26/ 13 GAF-518-02-01 ASTM D226 Type II 06/04/ 14 GAF-818-02-01 ASTM D4533 12/06/ 17 GAF-829-02-01 ASTM D226 Type II 01 /15/ 18 GAF-314-02-01 ASTM D2178 07/21 / 11 GAF-315-02.01 ASTM D2178 07/21 /11 GAF-826-02-01 ASTM D226 Type II 07/ 12/ 18 ASTM D4533 GAF447-02-01 ASTM D226 Type II 06/05/ 18 ASTM D4533 GAF-914-02-01 ASTM D226 Type II 04/11/ 19 ASTM D4533 Trinity-ERD GAF-SC13285 . 17- 1 ASTM D1970 03/08/ 17 GAF-SC13285 . 17-3 ASTM D1970 03/08/ 17 GAF-SC13285 . 17-4 ASTMD1970 03/08/ 17 GAF-SC13285 . 17-2 ASTM D4601 Type II 03/08/ 17 GAF-SC9700.08 . 15-RI ASTM D2178 02/08/ 17 GAF-SC12915 .09 . 17 ASTMD1970 12/ 11/ 17 GAF-SC12915,09 , 17 ASTM D6163 12/ 11 / 17 GAF-SC12915.09. 17 ASTM D7530 12/ 11 / 17 NEMOjetc. 4S-GAF- 18-001 .01 . 19- 1 ASTM D2178 Type IV 1 /2/2019 4S-GAF- 18-001 .01 , 19- 1 ASTM D2178 Type VI 1/2/2019 NOA No.: 184023. 10 MIAMI•DADE COUNTY Expiration Date: 02/22/23 Approval Date: 05/09/19 Page 4 of 8 APPROVED ASSEMBLIES : Deck Type 1 : Wood, non-insulated Deck Description: 11/32" or greater plywood or wood plank System E(I) : Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: Two plies of ASTM D 226 Type 1 or Shingle-Mate Roof Deck Protection OR one or more plies of ASTM D 226 Type II, Deck-Armor" Premium Breathable Roof Deck Protection, FeltBustero High-Traction Synthetic Roofing Felt, or Tiger Paw" Roof Deck Protection with a minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based sean>/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. j Membrane: One or more plies of WeatherWatch"" Mineral Surfaced Leak Barrier, StormGuard` Film Surfaced Leak Barrier, Liberty'' SA Glass Cap Sheet, or Liberty" SBS Self-Adhering Base/Ply Sheet membrane with a minhnum 3" side lap and 6" end lap. Place the first course of membrane parallel to the eave; rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch"' Mineral Surfaced Leak Barrier, or StornaGuard'' Film Surfaced Leak Barrier is acceptable. Surfacing: Approved Roofing Assembly. Deck Type 1 : Wood, non-insulated Deck Description: 1 '/,2 ' or greater plywood or wood plank System E(2) : Membrane mechanically fastened to deck. Separator Sheet: One or more plies of GAF GAFGLAS" Ply 4, GAFGLAS" F1exPly` 6, Rosin Paper, ASTM D 226 Type 1 or Type It, Shingle-Mate' Roof Deck Protection, Deck-Armor` Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, or Tiger Paw"' Roof Deck Protection loose laid. Membrane: One or more plies of WeatherWatch" Mineral Surfaced Leak Barrier, StormGuard" Film Surfaced Leak Barrier, Liberty"' SA Glass Cap Sheet, or Liberty''l SBS Self-Adhering Base/Ply Sheet membrane mechanically fastened with a minimum 3" side lap and a 6" end lap to deck through the separator sheet with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. in the field of the roll. Surfacing: Approved Roofing Assembly. NOA No.: 184023.10 MIAMIOADE COUNTY Expiration Date: 02/22/23 Approval Date: 05/09/19 Page 5 of 8 i I I Deck Type 1 : Wood, non-insulated Deck Description: 19h2" or greater plywood or wood plank System E(3) : Anchor sheet mechanically fastened to deck, membrane adhered. Secondary Water Install a minimum 4" wide WeatherWatch'' Mineral Surfaced Leak Barrier, Liberty" SBS Self- Barrier: Adhering Base/Ply Sheet, Liberty'" SA Glass Cap Sheet, or StortnGuard' Film Surfaced Leak (Optional) Barrier membrane over the joints of the plywood roof deck prior to installation of the base sheet. Do not overlap end or side joints. All side and end laps should be butted firmly side by side, flush with each other but not overlapped. Do not leave the WeatherWatch" Mineral Surfaced Leak Barrier, or StormGuard" Film Surfaced Leak Barrier membrane exposed for more than 30 days without a roof deck protection underlayment protecting the secondary water barrier. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate" Roof Deck Protection OR one or more plies of ASTM D 226 Type II, Deck-Armor' Premium Breathable Roof Deck Protection, FeltBusteO' High-Traction Synthetic Roofing Felt, or Tiger Paw'" Roof Deck Protection with a minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll . If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based scam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fasteners. Surfacing: Approved Roofing Assembly. Deck Type 1 : Wood, non4nsulated Deck Description: "/32" or greater plywood or wood plank System E(4) : Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate® Roof Deck Protection OR one or more plies of ASTM D 226 Type II, Deck-Armor'"' Premium Breathable Roof Deck Protection, FeltBuster" High-Traction Synthetic Roofing Felt, or Tiger Paw" Roof Deck Protection with a minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer' s installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of StormGuard" Film Surfaced Leak Barrier membrane with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Surfacing: Approved for Metal roofing, Slate, and Asphalt Shingle assemblies. NOA No.: 184023.10 MIAMI•DADE COUNTY Expiration Date: 02/22/23 Approval Date: 05/09/19 Page 6 of 8 i LIMITATIONS : 1 . Fire classification is not part of this acceptance. 2. WeatherWatch" Mineral Surfaced Leak Barrier, StormGuare' Film Surfaced Leak Barrier, Liberty" SBS Sclf- Adhering Base/Ply Sheet, Liberty " SA Glass Cap Sheet, Shingle-Mate' Roof Deck Protection, Deck-Armor' ' Premium Breathable Roof Deck Protection, FeltBuster` High-Traction Synthetic Roofing Felt, and Tiger Paw"' Roof Deck Protection shall not be used as roof the underlayment. 3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. WeatherWatchl Mineral Surfaced Leak Barrier, StormGuard' Film Surfaced Leak Barrier, Libertyi" SBS Self-Adhering Base/Ply Sheet, Liberty' SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor"' Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger Paw"' Roof Deck Protection shall be installed in strict compliance with applicable Building Code. 4. WeatherWatch" Mineral Surfaced Leak Barrier, StormGuard"" Film Surfaced Leak Barrier, Liberty" SBS Self- Adhering Base/Ply Sheet, Liberty"' SA Glass Cap Sheet, Shingle-Mate` Roof Deck Protection, Deck-Armor` Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger Paw"' Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities , 5. WeatherWatchl Mineral Surfaced Leak Barrier, StormGuard" Film Surfaced Leak Barrier, Liberty"' SBS Self- Adhering Base/Ply Sheet, Liberty"' SA Glass Cap Sheet, Shingle-Mate" Roof Deck Protection, Deck-Annor Premium Breathable Roof Deck Protection, FeltBuster` High-Traction Synthetic Roofing Felt, and Tiger Paw' Roof Deck Protection membranes shall not be applied over an existing roof membrane. 6. WeatherWatch' Mineral Surfaced Leak Barrier, StormGuard`' Fihn Surfaced Leak Barrier, Liberty"' SBS Self. Adhering Base/Ply Sheet, Liberty" SA Glass Cap Sheet, Shingle-Mate" Roof Deck Protection, Deck-Armor` Premium Breathable Roof Deck Protection, FeltBusterO High-Traction Synthetic Roofing Felt, and Tiger Paw" Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. 7. WeatherWatch'' Mineral Surfaced Leak Barrier, StormGuard" Film Surfaced Leak Barrier, Liberty"' SBS Self- Adhering Base/Ply Sheet, Liberty"' SA Glass Cap Sheet, Shingle-Mate® Roof Deck Protection, Deck-Armor"' Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger Paw" Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatchl Mineral Surfaced Leak Barrier, StormGuard" Film Surfaced Leak Barrier, Liberty"' SBS Self-Adhering Base/Ply Sheet, Liberty" SA Glass Cap Sheet, Shingle-Mate" Roof Deck Protection, Dcck-Armor" Premium Breathable Roof Deck Protection, FeltBuster° High-Traction Synthetic Roofing Felt, and Tiger Paw'' Roof Deck Protection as a component part of an assembly in the Notice of Acceptance. If WeatherWatch' Mineral Surfaced Leak Barrier, StormGuar&' Film Surfaced Leak Barrier, Liberty"' SBS Self-Adhering Base/Ply Sheet, Libertyj" SA Glass Cap Sheet, Shingle-Mate' Roof Deck Protection, Deck-Armor"' Premium Breathable Roof Deck Protection, FeltBuster' High-Traction Synthetic Roofing Felt and Tiger Paw"' Roof Deck Protection are not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 8. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 450 F and rising. 9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. NOA No.: 184023.10 MIAMI•DADE COUNTY Expiration Date: 02/22/23 Approval Date: 05/09/19 Page 7 of 8 LIMITATIONS : 10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code, 12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIA146DADE COUNTY • o END OF THIS ACCEPTANCE NOA No.: 184023.10 MIAMIOADE COUNTY Expiration Date: 02/22/23 o Approval Date: 05/09/19 Page 8 of 8