HomeMy WebLinkAboutProduct Approval , flat deck i
3/15/2021 Florida Building.Code 0 11 - —
BCIS Home I Log.In I User Registration I Hot Topics.I Subq tVrcharg'e el-.Sta"&Fncts..I-Publications-]Contact Us I BCIS Site Map I Links I Search
Florida
Product Approval
(gil
USER:Public User
v�
p@dVijgpnroval Menu>Product or Application Search>Application Ust>Application Detail
LA
Application Type Revision 1 \L�
Code Version 2020
Application Status Approved
Comments ®rl
��
Archived ;,_J J
Product'Manufacturer - Soprema,Inc.(Canada) '� F KI
Address/Phone/Email 1640 rue,Haggarty'
Drummondville,NON-US 00000 CODE COMPLIANCE
(819)478-2400
memathieu@soprema.ca ST® LUCIE COUNTY
Authorized Signature Marc-Etienne Mathieu ;TBOCC
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Emall 168E Jean-eerchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca.
I
Quality Assurance Representative 'Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
J Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M.Nieminen
Evaluation Report
Florida Ucense PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W.Knezevich,PE
0A Validation Checklist-Hardcopy Received
i
i
Certificate of Independence FL2569 R21 COI 2020 01 COI NIEMINEN.odf
i
i
Referenced Staff dard and Year(of Standard) Standard year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2015
FM 4474 2011
FRSA/TRI Sixth Edition 2018 !
UL 1897 2015
i
https://www.iloridabuilding:org/prlpr app_dU.aspx?param=wGEVXQwtDgsKQFEnckBlO8ErxlUd3xYlzoPsogGl4itVgZ9SrxpeDg%3d%3d 1/2
l
I
• ii I
3/15/2021 Florida Building Code Online
Equivalence of Product Standards
Certified By .
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summary of Products
f
FL# Model,Number or Name Description
2869.1 Soprema Roof Underlayments Self adhering roof underlayments
i
Limits of Use Installation Instructions
Approved for use in HVHZ:No FI 2569 R71 112020 12 16 FINAL ER SOPREMA FL2569-
Approved for use outside HVHZ:Yes R21.pdf
Impact Resistant:N/A Verified By: Robert Nieminen,P.E.PE-59165
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1,)Refer to ER Section 5 for Limits of Use.2.)The Evaluation Reports
design pressure noted herein pertains to underlayment systems FI 2569 R21 AF 7020 17 16 FINAL ER SOPREMA FL2569-
used beneath adhesive-set the systems.Refer to ER Section R21.pg
5.8.3 for details. Created by Independent Third Party:Yes
Back i•lext
Contact Us::2601 Blair Stone Road,Tallahassee FL.32399 Phone.850-487-1824
The State of Florida Is an AA/EEO employer.copyright 2007-2013 State of Florida.::privacy Statement::Accesslbllity,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a-public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by tradltional mall.If you have any questions,please contact 950.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have One.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email addresswhich can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts.
fttj 1 �
Credit Card i
Safe i
ow
I
i
,7
i
t
I
https://www.iloddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBIOBErxlUd3xYlzoPso9G14itVgZ9SrxpeDg%3d%o3d 2/2
t
• I
NEMO etc.
Certificate of Authorization#32455
353 Christian"Street,Unit#13
Oxford,CT 06478
(203)"262-9245
ENGINEER EVALUATE. TEST CONSULT
REPORTEVALUATION
Soprema,Iric. Evaluation Report S18010.06.09-11119
1640 rue Haggerty FL2569-R21-
Drummondville,Quebec J2C SP8 Canada Date of Issuance:06/15/2009.
(819)478-2400 Revision 19 12/16/2020
SCOPE:
i
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted'has been reviewed by Robert Nleminen,
P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 71h Edition(2020).Florida Building Code sections noted herein.
-DESCRIPTION Soprema lRoof Ullderlayments
LABELING: Labeling.shall be,in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 15W.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such,time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC'of any
changes to.the product(s), the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a
complete review of its Evaluation-Report relative to updated Code requirements with each Code Cycle.
I
ADVERTISEMENT:The Florida Product Approval Number(FL#)preceded by the words"NEMOIetc. Evaluated"may be
displayed in advertising literature. if any'portion of the Evaluation Report is displayed,then it shall be done in its
entirety.
INSPECTION:Upon request,a copy.of this entire Evaluation Report shall be provided to the-user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.,.
This Evaluation Report consists of pages 1 through 9.
Prepared by: •�,,,,,mn,;,
Robert l.M.Nieminen,P.E. '?;.•���_.- ;:' The facsimile seal appearing was authorized by Robert
9gip••ve, Nieminen,P.E.an 12116/2020.This does not serve as j
Florida Registration No.59166,Florida DCA ANE1983 . ��:r
t'•1'•••++n++•" an electronically signed document.
CERTIFICATION OF INDEPENDENCE:,
1. NEMO ETC;LLC does not have;nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company.manufacturing or distributing products it evaluates,
3. Robert Nieminen,P.E.does not have norwill acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued. .
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the.approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEW ETC,LLC
J
I�
i 4
I )
I [:
i
ONEmol-etc.
ROOFING COMPONENT.EVALUATION:
III SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
with the following`sections of the 7u'Edition(2020)Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and'Limitations/Conditions of Use
set forth herein.
StANDARDS:
Section Pro"e - Standard Year;
1504:3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 7018
1507,11.2/11905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Etti" Examination Reference Date `
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.30-1-R1 04/07/2010
ERD;(TST6049)" FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) 537210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049). FRSA/TRI 04-12(MS) 543530.02.141-111 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH)• S44870.04.14-1 04/10/2014
ERD(TST6049). ASTM D1970-(MS) S44870.04.144 04/16/2014
ERD(TST6049) ASTM D1970(OH) 540540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC750520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592). HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019.
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-OI:A.R2 02/10/i02O
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049). Peel adhesion(existing underlayments) 4)-SOPC-20-SSUDL-01 12/16/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 • 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLAFile No.R36814 12/10/2015
ULi LLC(QUA9625) Quality Control MLA File No.R27605' 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
NEMO ETC,LLC, Evaluation Report S18010.06.09-R19
Certificate of Authorization#32455 7TM EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/1S/2020
Page 2 of 9
I
1 ♦ �
II
I
i
ONEMOjetc.
• PRODucT
Material
Product Plants) Description
Standard
4.1 Lastobond TU HT ASTM D1970'and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRi 09-18 surfaced,SBS modified bitumen roof'
underlayment
4.2 Tri-Built S/A HT TU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
Underlayment FRSA/TRI 09.18 surfaced;SBS modified bitumen roof
underlayment
4.3 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.4 RESISTO SA SMOOTH PLY ASTM.D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.5 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.6 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
'two widths;36 and 45 inch
4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.8 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.9 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,-SBS modified bitumen roof
underlayment
4.11 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.12 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.13 Tri-Built Smooth HT S/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.15 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.16 TRI-BUILT Sand-R SA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle Underlayment Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
I
NEMO ETC,U.0 Evaluation Report S18010.06.09-1119
Certificate ofAuthorfzatlon N32455 7-E017ION(2020)FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 3 of 9
I
I
I
I
I
I
l I
NNEMO etc.
Material:,
',:Product Plant(s) Description
Standard
4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave.&Valley Protector Gulfport,MS surfaced;SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth;OH underlayment
4.19 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,Sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.20 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
S. LimiwiONS:'
5.1 This is a building code evaluation. Neither NEMO ETC,,LLC nor Robert Nieminen,P.E.are,in Anyway,the Designer
of Record for any project on which:this Evaluation Report;or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for.use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-
bade Counties).
5.3 This'Evaluation,Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction,ofthe Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification.. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam-plastic insulation.
5.5 Soprema Roof Underlayments may-be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. if not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1'ROOF COVER OPTIONS
SecHon: .'" t5072 .1 1507.3 1507.E&1507.5 1507.T 1507.8 a 1507.9
FBC
clay Convete'Tile Metal or'Slate Asphalt` Y Wood Shakes or
Uriderlayment, Mechanical . Adhesive Sl'ate-Type
Shingles•.a 4itach 5ef Panels Shingles hlnBl. hingle9
S S
Lastobond TU HT,Tri-Built S/A HTTU Yes Yes
Underayment See 5.6.1
Yes Yes Yes Yes Yes Qoint strips,1S07.1.13 J
R9os.1.13).
Lastobond Shield,Pro HT-N,RESISTO SA Yes.
SMOOTH PLY40 Yes No, No No No Yes goint strips,1507.1.L3/
R905.1.7,3
Yes
Lastobond Shield HT,Pro HT S Yes No No Yes Yes Yes Oointstdps,tsOM.13/
R905.L3.3)
Yes
EnviroShield Yes No No Yes Yes Yes point strips,1507.1.L3/
11905.113)
Lastobond Eaves Protection Sheet, Yes
Las toband195 Yes No No No No Yes GaIntitrips,lsazl.L3/
R905.L3.3)
NEMO ETC,LLC Evaluation Report518010.06.09•RL9. .
CertfFcote of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 4 of 9
�I
i
ONEMO etc.
'`TABLE'1: ROOF COVER OPTIONS _
FBCSecdon: 1507.2 -1507.3 1507.4&1507.5 1507.7 1507.8&1507.9
Clay and Concrete Tile. Metal Slate or
Asphalt Shakes or
Underlayment Aspha Mechanical Adhesive- Slate-Type
Shingles Attach Set Shingles Panels Shingles Shingles
Lastobond ECO,RESISTO LB1236,TRI-
BUILT Sand-RSA Shingle Underlayment, Yes
Grip-Rite Eave&Valley Protector, Yes No No No No Yes (Joint strips,1507.1.1.3/
TopShleld ICE&WATER DEFENDER, R905.1.13)
RESISTO LB1244
Lastobond Smooth Seal HT,Tri-Built Yes
Smooth HTS/A Underlayment,Grip-Rite Yes No No Yes Yes Yes QoInt strips,1507.1.1.3/
Smooth Seal HT R905.1.1.3)
Col hene FR GR Yes Yes No No No Yes Yes
p Uolnt strips,1507.1.1.3/
R905.M3)
5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
TABLE'IA:ALLOWABLE TILE ADHESIVE/-UNDERLAYMENT COMBINA-nONS3
Underlayment Adhesive Florida Product Approval
Lastobond TU HT,Tri-Built S/A Dupont"rile Bond"'Roof Tile Adhesive" FL22525
HT TU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
Lastobond Shield,Lastobond Pro (Optional)ASTM
HT-N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick, plywood,OSB or Southern Yellow Pine
40,Lastobond Shield HT, sheathing Elastocol Stick Zero (SYP)
Lastobond Pro HT-S, ASTM D41 structural concrete I
EnviroShield,Lastobond TU HT,
Tri-Built S/A HT TU Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Underlayment,Lastobond Eaves Stick Zero Fiber Roof Board I
Protection Sheet,Lastobond 195, self-
Lastobond ECO,RESISTO LB3236,
TRI-BUILT Sand-R SA Shingle adhering
Underlayment,Grip-Rite Eave&
Valley Protector,TopShield ICE& Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
WATER DEFENDER,RESISTO StickZero G
LB1244,Lastoband Smooth Seal
HT,Tri-Built Smooth HT S/A
Underlayment or Grip-Rite
Smooth Seal HT
(Optional)ASTM
Deck/ D41 Plywood
sheathing
self- ASTM D41 structural concrete
Colphene FR GR adhering Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified 5opra-
StickZero G
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report S38010.06.09-R19
Certii lcate of Autharizadon t132455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/20I0
Page 5 of 9
I
i
I
OMEMO etc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO
LB1236,TRI-BUILT Sand-R SA self- Existing RESISTO EXTERIOR Existing sand-surfaced,glass-fiber surfaced,
Shingle Underlayment,Grip-Rite adhering substrate PRIMER mineral-surfaced or film-surfaced roof
Eave&Valley Protector or underlayment*
TopShield ICE&WATER
DEFENDER
*Final acceptance of any existing substrate in a reroof(tear-off)Installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-BuiltS/A HT
TU Underlayment RESISTO LB1236,TRi-BUILTSand-R SA Shingle Underlayment Grip-Rite Eave&Valley Protector or TopShield ICE&
WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Gay Roof Tile Installation Manual, Sixth Edition,Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the.result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67:5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,Tri-Built 5/A HT TU Underlayment,self-adhered.
NEMO ETC,LLC Evaluation Report S38010.06.09-R39
Certificate of Authorization#32455 7TM EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
I j
I
i,
I
NNEMOletc.
#3 Maximum Design Pressure=-120.0 osf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: 11E51STO SA SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#4 Maximum Design Pressure=-150.0 osf:
Deck: Min.15/32-inch APA-rated BCX plywood(may be installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-BuiltS/A HT TU Underlayment,self-adhered.
#5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet.or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design.pressure determined In accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design-pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the.elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
96 Maximum Design Pressure=-60.0 asf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.S.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c.In three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,Tri-BuiltS/A HTTU Underlayment,self-!adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment I
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval l
5.9 Exposure Limitations:
TABLE 3',E%POSURE LIMITATIONS'
Underlayment
Prepared Roof Cover Maximum,.
Installation Type Exposure(days)
Lastobond Eaves.Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,TRI- Mechanically
BUILTSand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopShieldlCE attached 30
&WATER DEFENDER or RESISTO LB1244 !
Lastobond TU HT,Tri-Built S/A HT TU Underlayment Adhesive-set tile roof30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Mechanically
ly 90
Underlayment or Grip-Rite Smooth Seal HT
ed
Mechanically
Lastobond TU HT,Tri=Built S/A HT TU Underlayment or Colphene FR GR attached 180
NEMO ETC,LLC Evaluation Report S18010.06.09-R19
Certificate ojAuthorization#32455 i 77H EDITION(2020)FBC NON-HVHZ EVALUATION T1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 7 of 9 �
I
' � 1
I
i
i
i I
ONEMOletc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TA9LE4: TILE SuppAGELIMITATIONs(FORDIRELT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT,Tri-
Built S/A HT TU
Underlayment Lugged j
rC,Iph,ne FR GR Flat Max.10-tile stack 5:12
FR GR
Lugged Max.10-tile stack 6:12
0
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off)application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 Lastobond TU.HT, Tri-Built'S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N,'RESISTO SA,
SMOOTH PLY 40,Lastobond-Shield.HT,1astobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet,
Lastobond 195,Lastobond Eco,'Lastobond Smooth Seal HT,Tri-Built Smooth HT 5/A.Underlayment;Grip-Rite-
Smooth Seal. HT, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle 'Underlaymett,-Grip-Rite Eave & Valley
Protector,TopShield:ICE&WATER DEFENDER,,RESISTO'L61244 or Colphene FR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation Instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
MEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8 of 9
I
NNEMO etc.
6.3.2 Tile Applications:
Limited to Lastobond TU HT,Tri-Built S/A HTTU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay-Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions. i
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
7. BUILDING PERMit REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
S. MANUFAcTURING PLANTS:.
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
119. QUALITY AssURANcE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END-OF EVALUATION REPORT-
'I
li
I
I
i
NEMO ETC,LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization N32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21 j
Soprema Roof Underlayments Revision 19:12/1S/2020
Page 9 of 9
i
i