HomeMy WebLinkAbout19030504(5)(2)
NOA No.: 19-0305.04
Expiration Date: 08/08/23
Approval Date: 08/15/19
Page 1 of 6
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations gover ning the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within thei r jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium® UDL25, Titanium® UDL30, Titanium® UDL50, Titanium® PSU30, RhinoRoof®
U10, RhinoRoof® U20, RhinoRoof® Granulated, RhinoRoof® Metal, TriBuilt, and ABC Pro
Guard 20 Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 18-0814.09 and consists of pages 1 through 6.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 19-0305.04
Expiration Date: 08/08/23
Approval Date: 08/15/19
Page 2 of 6
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Polypropylene
SCOPE:
This acceptance is for Titanium® UDL25, Titanium® UDL30, Titanium® UDL50, Titanium® PSU30, RhinoRoof®
U10, RhinoRoof® U20, RhinoRoof® Granulated, RhinoRoof® Metal, TriBuilt, and ABC Pro Guard 20
underlayments as described in this Notice of Acceptance, for use with approved prepared roof assemblies where
ASTM D226 Type II (Titanium® UDL30, Titanium® UDL50, RhinoRoof U10, RhinoRoof® U20, Titanium®
UDL25, ABC Pro Guard 20) or ASTM D1970 (RhinoRoof® Granulated, RhinoRoof® Metal, and Titanium® PSU30
only) underlayment is specified and installed with prescribed approved fasteners and fastener densities. Designed to
comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code
PRODUCT DESCRIPTION:
Product
Dimensions
Test
Specification
Product
Description
Titanium UDL25
Manufacturing
Location #1
Titanium® UDL-30
Manufacturing
Location #1
48” x 250’ rolls
48” x 250’ rolls
ASTM D226
Type I & II
ASTM D226
Type I & II
Woven synthetic polymer underlayment with two
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Woven synthetic polymer underlayment with two
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Titanium® UDL-50
Manufacturing
Location #1
48” x 250’ rolls ASTM D226
Type I & II
Woven synthetic polymer underlayment with two
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
RhinoRoof U20
Manufacturing
Location #1, 2
42” x 286’ rolls ASTM D226
Type I and II
Woven synthetic polymer underlayment with two
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
RhinoRoof U10
Manufacturing
Location #1, 2
RhinoRoof Granulated
Manufacturing
Location #4
RhinoRoof Metal
Manufacturing
Location #3
42” x 286’ rolls
36”x65’ rolls
36”x71.3” rolls
ASTM D226
Type I & II
ASTM D1970
ASTM D1970
Woven synthetic polymer underlayment with two
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
SBS self-adhering modified asphalt underlayment
sheet material with a surfacing of opaque
granules; for use as an underlayment in sloped
roof assemblies.
SBS self-adhering asphalt sheet material with a
film facer; for use as an underlayment in sloped
roof assemblies
NOA No.: 19-0305.04
Expiration Date: 08/08/23
Approval Date: 08/15/19
Page 3 of 6
PRODUCT DESCRIPTION:
Product
Dimensions
Test
Specification
Product
Description
ABC Pro Guard 20
Manufacturing
Location # 2
TriBuilt
Manufacturing
Location #2
Titanium PSU30
Manufacturing
Location #3
42” x 286’ rolls
42” x 286’ rolls
36”x72’ rolls
ASTM D226
Type I & II
ASTM D226
Type I & II
ASTM D1970
Woven synthetic polymer underlayment with two
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Woven synthetic polymer underlayment with two
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Unreinforced polymer modified bitumen material
adhered to the underside of a reinforced, polymer-
coated, synthetic woven sheet. The underside is
backed with a release film.
MANUFACTURING LOCATIONS:
1.
2.
3.
4.
ML1
ML2
ML3
ML 4
EVIDENCE SUBMITTED :
Test Agency Test Identifier
Test Name/Report Date
PRI Construction Materials
Technologies, LLC
OCF-332-02-01
OCF-334-02-01
OCF-331-02-01
OCF-341-02-01
OCF-392-02-02
OCF-393-02-02
OCF-394-02-02
OCF-395-02-07
OCF-282-02-03
OCF-293-02-02
OCF-394-02-07
OCF-394-02-02.2
ASTM D226
ASTM D226
ASTM D226
ASTM D1970
ASTM D226
ASTM D226
ASTM D226
ASTM D226
ASTM D1970
ASTM D1970
ASTM D226
ASTM D226
05/07/19
05/07/19
05/07/19
11/28/17
08/28/18
08/28/18
04/15/19
04/15/19
02/19/18
12/28/17
04/15/19
07/29/19
NOA No.: 19-0305.04
Expiration Date: 08/08/23
Approval Date: 08/15/19
Page 4 of 6
APPROVED ASSEMBLIES:
Deck Type 1: Wood
Deck Description: 19/32" or greater plywood or wood plank
System E (1): Base sheet mechanically fastened to deck, subsequent cap membrane self - adhered.
All General and System Limitations shall apply.
Base sheet: One or more plies of ASTM D226, Type II or ASTM D2626 applied with minimum 4” side
laps and minimum 6” vertical laps and mechanically fastened as noted below.
Fastening: Miami-Dade approved nails & metal/tin caps spaced 6”o.c. at the 4” side laps and two
staggered rows 12”o.c. in the field of the sheet.
Membrane: One or more plies of Titanium® PSU-30, self-adhered, with 3” horizontal laps and minimum
6” vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave, using a
heavy pressure roller under safe conditions to further secure the membrane.
Surfacing: Approved for asphalt shingles, metal roofing, wood shakes & shingles, and quarry slate roof
assemblies.
INSTALLATION SPECIFICATIONS:
Titanium® UDL30, Titanium® UDL50, RhinoRoof ® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 Underlayments
1. Titanium® UDL30, Titanium® UDL50, RhinoRoof U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 Underlayments
shall be installed in strict compliance with applicable Building Code.
2. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, and ABC Pro Guard 20 underlayments shall be installed
with a minimum 4-inch side lap in a shingle layer fashion. Titanium® PSU30 shall be installed with a 3-inch
side lap in a shingle layer fashion.
3. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25 , TriBuilt, and ABC Pro Guard 20 underlayments shall be fastened
with Miami-Dade approved corrosion resistant tin-caps and 12 gauge 1 ¼” annular ring-shank nails, spaced 6”
o.c. at all laps and three staggered rows fastened 12” o.c. in the field of the roll.
4. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, Titanium PSU30, TriBuilt, and ABC Pro Guard 20 underlayments
may be used with Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofing, and quarry
slate. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, Titanium PSU30 and
Titanium® UDL25 Synthetic Underlayments shall not be used as roof tile underlayments.
5. For fire classification of specific roof assemblies using Titanium® UDL30, Titanium® UDL50, RhinoRoof®
U10, RhinoRoof® U20, RhinoRoof® Granulated, RhinoRoof® Metal, Titanium® UDL25, ABC Pro Guard
20, TriBuilt and Titanium® PSU30 Underlayments, refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
NOA No.: 19-0305.04
Expiration Date: 08/08/23
Approval Date: 08/15/19
Page 5 of 6
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 underlayments
shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in the deck shall
be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to
remove any dust and debris prior to application.
4. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 underlayments
shall not be hot mopped. Refer to manufacturer’s published literature for product compatibility.
5. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 underlayments
shall not be applied over an existing roof membrane as a recover system.
6. RhinoRoof® U10, RhinoRoof® U20, and ABC Pro Guard 20 underlayments shall not be left exposed as a
temporary roof for longer than 60 days after application. Titanium® UDL25, Titanium® UDL30, Titanium®
UDL50, and Titanium® PSU30 self-adhering underlayment shall not be left exposed as a temporary roof for
longer than 180 days after application. RhinoRoof® Metal self-adhering underlayment shall not be left
exposed as a temporary roof for longer than 90 days after application. TriBuilt and RhinoRoof ® Granulated
self-adhering underlayment shall not be left exposed as a temporary roof for longer than 30 days after
application.
7. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 underlayments
are components used in roof system assemblies. Roof system assemblies are approved under a specific Notice
of Acceptance. Refer to Prepared Roofing System Product Control Notice of Acceptance for listed approval of
this product with specific prepared roofing products.
8. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 underlayments
may be used with any approved roof covering Notice of Acceptance listing Titanium® UDL30, Titanium®
UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated, RhinoRoof® Metal, Titanium®
UDL25, TriBuilt, ABC Pro Guard 20, and Titanium® PSU30 underlayments as a component part of an
assembly in the Notice of Acceptance. If Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10,
RhinoRoof® U20, RhinoRoof® Granulated, RhinoRoof® Metal, TriBuilt, ABC Pro Guard 20, Titanium®
UDL25, and Titanium® PSU30 underlayments are not listed, a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
NOA No.: 19-0305.04
Expiration Date: 08/08/23
Approval Date: 08/15/19
Page 6 of 6
9. All membranes or packaging shall bear the imprint or identifiable markin g of the manufacturer's name or logo
and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE