HomeMy WebLinkAboutProduct Approval, underlayments iE F
7777
�Mhp �i� i'^ i��✓+ } i ,4' ,.�P{ N ' E`&-. -*d M1. 9'II4 ' - y tYkt _ fF �j
},Maa PE. � s5 :�•
BCIS Home, Log In User Registration" Hot Topics Submit Surcharge # Stats&Facts { Publications Contact Us j BCIS Site Map Links Search
T� .
Product Approval
,USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL2569-R21
Application Type Revision REVIE ELA Fcni
Code Version 2020
Application Status Approved O® V"-F NJ ;. 9CE
CommentsBOCC
i
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400
memathieu@soprema.ca File Copy'
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
'Drummondville, NON-US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca �.
i
Quality Assurance Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty- i
Drummondville
(888) 811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Li Evaluation Report- Hardcopy Received
Florida Engineer or,Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By ! John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Indepiendence FL2569 R21 COI 2020 01 COI NIEMINEN.pdf j
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 20151
ASTM D4798 20111
ASTM D6163 2015
FM 4474 c 2011
FRSA/TRI Sixth Edition 2018
UL 1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summary of Products
FL# Model, Number or Name Description
2569.1 Soprema Roof.Underlayments- Self adhering roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL2569 R21 II 2020 12 16 FINAL ER SOPREMA FL2569-
Approved for use outside HVHZ: Yes R21.pdf
Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150 Created by Independent Third Party: Yes
Other: 1-.)Refer to ER Section 5 for Limits of Use. 2.)The Evaluation Reports
design pressure noted herein pertains to underlayment systems FL2569 R21 AE 2020 12 16 FINAL ER SOPREMA FL2569-
used beneath adhesive-set tile systems. Refer to ER Section R21.pdf
5.8.3 for details. Created by Independent Third Party: Yes
Bacic Next .
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.;:Privacy tatement::Accessibility Statement::Refund Statement -
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by tradition al:mail.If you have any questions,please.contact 850.487.1395.*Pursuant to Section 455.275(1);
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S„please click here.
Product Approval Accepts:
Cfeciltrd
' s6fd
j I j
MEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
Soprema,Inc. Evaluation Report S18010.06.09-1119
1640rue Haggerty FL2569-R21
Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 19:12/16/2020 j
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of j
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, I
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7"Edition(2020)Florida Building Code sections noted herein. 1
a
„_DESCRIPTION::Soprema Of U'nderlayriments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time asthe named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes,or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any i
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review.of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida.Product Approval Number(FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a.copy of this entire Evaluation Report shall be provided to the user by the manufacturer I
or its distributors and shall be available for inspection at the job site at the request of the Building Official. .
I
This Evaluation Report consists of pages 1 through 9.
I
Prepared by:
Robert J.M.Nieminen,P.E. �O� y�f 4 The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCAANE1983 � Nieminen,P.E.on 12/16/2020.This does not serve as
� �^ an electronically signed document.
CERTIFICATION OF INDEPENDENCE:,
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC,LLC
i I
"
i
I I
i
f
I
i.
n
MEMO l @tc.
ROOFING COMPONENT EVALUATION:
IGISBN
Product Category: Roofing w
Sub-Category: Underlayment
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
i
with the following sections of the 7"Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
set forth herein.
Section PropertV
- Standard Year
- - -. .
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
Enti Examination_ Reference . - Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) S37210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD.(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014 .
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) . ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 .04/10/2014.
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM,D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01 12/16/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 . 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
NEMO ETC,LLC Evaluation Report 518010.06.09-R19
Certificate ofAuthorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 2 of 9
I
NNEMOjetc.
Material
Product Plant(s)_ Description
Standard. _-
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
2 rUn=derlayment
ASTM D1970 and Gulfport,MS self-adhering,non-wovenpolyesterfabric"
FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.3 stobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.4 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.5 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.6 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof I
underlayment
4.8 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.9 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.11 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.12 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film
HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.13 Tri-Built Smooth HT S/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.15 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment j
4.16 TRI-BUILT Sand-R SA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle Underlaymf nt Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH I underlayment
I �
NEMO ETC,LLC ; Evaluation Report S18010.06.09-R19 j
Certificate of Authorization#324S5 I 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 3 of 9
i
NNEmoletc.
Product Material plant(s) Description
Standard
4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.19 RESISTO LB1244, ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.20 Colphene FIR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in anyway,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.'
5.6 Allowable Roof Covers:
it ABLE.1 ROOF.,COVER OPTIONS;
fBCSection: 2507.2 1507.3 y 1507.4&1507.5 1507.7 i 1507.8&1507.9
Clay and Concrete Tile Metal Slate or
Underla me'nt Asphalt Wood Shakes or
y Mechanical Adhesive_- Slate-Type
Shingles Panefs Shingles ' Shingles
Attach Set. Shingles
Lastobond TU HT,Tri-Built S/A HT TU Yes Yes
Underlayment Yes Yes see5.6.1 Yes Yes Yes
(joint strips,1507.1.1.3/
R905.1.1.3)
Lastobond Shield,Pro HT=N,RESISTO SA Yes
SMOOTH PLY 40 Yes No No No No Yes
(Joint strips,1507.1.1.3/
R905.1.1.3)
Yes
Lastobond Shield HT,Pro HT-S Yes No No Yes Yes Yes (joint strips,1507.1.1.3/
R905.1.1.3)
Yes
EnviroShield Yes No No Yes Yes Yes
(joint strips,1507.1.1.3/
R905.1.1.3)
Lastobond Eaves Protection Sheet, Yes
Lastobond 195 Yes No No No No Yes Oointstrips,1507.1.1.3/
R905.1.1.3)
MEMO ETC,LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19,12/15/2020
Page 4 of 9
i
I
I
(NNEMOC.
TABLE' 'ROOFCOVER OPTIONS'-
FBCSection: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&15079
Clay and Concrete Tile Metal`" Slate or
Asphalt, Wood'Shakes or
Underlayment Mechanical Adhesive Slate-Type
Shingles Panels ShinglesShinglesShingles
Attach Set
Lastobond ECO,RESISTO LB1236,TRI
BUILT Sand-R SA Shingle Underlayment, Yes
Grip-Rite Eave&Valley Protector, Yes No No No No Yes point strips,1507.1.1.3 j
TopShield ICE&WATER D R905.1.1.3)
RESI 44
Lastobond Smooth Seal HT,Tri-Built Yes
Smooth HTS/A Underlayment,Grip-Rite Yes No No Yes Yes Yes point strips,1507.1.1.9/
Smooth Seal HT' R905.1.1.3)
Yes
ColpheneFRGR Yes Yes No No No Yes point strips,1507.1.1.3/
R905.1.1.3)
5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
r .TABLE lA.ALLOWABLE`TILE ADHESIVE UNDERLAYMENT COMBINATIONS)
Underlayment Adhesive ;Florida Product Approval
Lastobond TU HT,Tri-Built S/A Dupont"Tile Bond—Roof Tile Adhesive' FL22525
HT TU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" FL6332
5.7 Allowable Substrates:
TABLE 2 SUBSTRATE_C)PTIONSTOR ADHERED UNDEALAYMENTS x
Substrates(designed to meet wind loads for project)
Underlayment Application
Type Primer Material(s)
Lastobond Shield,Lastobond Pro (Optional)ASTM plywood,OSB or Southern Yellow.Pine
HT-N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick, (SYP)
40,Lastobond Shield HT, sheathing Elastocol Stick Zero
Lastobond Pro HT-S, ASTM D41 structural concrete
EnviroShield,Lastobond TU HT,Tri-Built S/A HT TU Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum
Underlayment,,Lastobond Eaves Stick Zero Fiber Roof Board
Protection Sheet,Lastobond 195,
self-
Lastobond ECO,RESISTO LB1236, II
TRI-BUILT Sand-R SA Shingle adhering
Underlayment,Grip-Rite Eave&
Valley Protector,TopShield ICE& Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra,l
WATER DEFENDER,RESISTO Stick Zero G
LB1244,Lastobond Smooth Seal
HT,Tri-Built Smooth HT S/A•
Underlayment or Grip-Rite
Smooth Seal HT
(Optional)ASTM Plywood
Deck/ D41
sheathing
ASTM D41 structural concrete
Col hene FR GR self-
P adhering Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
Stick Zero G
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,LLC i Evaluation Report 518010.06.09-R39
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION F1.2569-1121'
Soprema Roof Underlayments Revision 19:12/15/2020
Page 5 of 9
NNEMOletc.
TABLE 2 SUBSTRATE OPTIONS FOR ADHERED UNDERLAY
MENTS
Substrates(designed to meet wind'loads for project).
Underlayment Application
Type Primer" Materials)
Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO
1_131236;TRI-BUILT Sand-R SA self- Existing RESISTO EXTERIOR Existing sand_surfaced,glass-fiber surfaced;
Shingle Underlayment,Grip-Rite mineral-surfaced or film-surfa ced roof
adhering. substrate PRIMER
Eave&Valley Protector or Underlayment*
TopShield ICE&WATER
DEFENDER
*Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-Built S/A HT
TU Underlayment RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment Grip-Rite Eave&Valley Protector or TopShield ICE&
WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self=adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: - Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
NEM0 ETC,LLC Evaluation Report S38010.06.09-R19
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
ONEmoletl I
#3 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority j
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#4 Maximum Design Pressure=-150.0 psf:
Deck: i Min.15/32-inch APA-rated.BCX plywood(may be installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: . Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45-psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone,I1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set• forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure=-60.0 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction:
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in"accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE"3 RE EXPOSU bmifATIONS
r m'
ent
y
Prepared.RoofCover. Maximum�
Underla ,
Installation Type Exposure(days)"
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,TRI Mechanically
BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopShield ICE attached 30
&WATER DEFENDER or RESISTO LB1244
Lastobond TU HT,Tri-Built S/A HT TU Underlayment Adhesive-set tile roof30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A attached 90
Underlayment or Grip-Rite Smooth Seal HT
Mechanically
Lastobond TU HT,Tri-Built S I/A HT TU Underlayment or Colphene FR GR attached 180
I
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
jSoprema Roof Underlayments Revision 19:12/15/2020
Page 7 of 9
NEMo etc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE-SLIPPAGE LIMITATIONS FOR`DIRECT-DECK TILE^INSTALLATIONS
�. .,
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.10=tile stack 6:12
Lugged Max.10-tile stack 5:12.
Max.10-tile stack(bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope,as shown below) 6:12
Lastobond TU HT,Tri = r
Built S/A HT TU
Underlayment Lugged a i
NHS s
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
s
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off)application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off) installation is at the discretion of the installer and the:
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6:3 Lastobond TU HT, Tri-Built S/A HT TU Under'layin Lastobond"Shield, Lastobond Pro HT"N, RESISTO;SA;
SIVIOOTH PLY 40; Lastobond Shield HT,,Lastobond Pro-HT S,.EnviroShield, Lastobond�.Eaves'Protection Sheet;";
Lastobond 195,"Lastobond Eco,-Lastobond Smooth S,eal.HT,Tri Built Smooth HT$/A.Underlayment,Gnp Rite;°
Smo`o'th, Seal.HT;"RESISTO L61236, TRI BUILT Sand-R SA. Shingle Underlayment, Grip-Rite Eave & Valley
Protector;TopShield"ICE&WATER DEFENDER;�RESISTO;LB1244 or C o 1phen 'FR GR.
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC,LLC Evaluation Report 518010.06.09-R19
Certificate ofAuthorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8 of 9
r .
I I
I *NEMO I et:
I
C.
6.3.2 Tile Applications:
Limited to Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FIR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
I
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
I
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards. 1
•
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
i
I
i
I
I
i
I
i
NEMO ETC,LLC Evaluation Report S38010.06.09-1119
Certificate ofAuthorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 9 of 9
' I