Loading...
HomeMy WebLinkAboutApproved Plansswr _ W VQlATIIERBFP RD I - r- 49 ^Y" OtlTL'C ;. ------------------ ---------------- � i 9 PROPERTY LOT ONE-STORN� HOME SHED M RIq r,--�-- 3y OUTLOT 23 ! I May 10. 2017 N 1 LOCATION & SITE PLAN S-1 NO SCALE PROPERTY INFORMATION PARCEL No. 3404-501-0667-000 PERMIT No. 1705-0089 JURISDICTION: ST. LUCIE COUNTRY LAND SIZE: 230, 868 SF (5.3 ACRES) HOME AREA: 990 APPROX. SHED AREA: 187 SF APPROX. [Mmidwo I. THIS PLAN CONTAINS SCHEMATIC DRAWINGS WITH APPROXIMATE DIMENSIONS, AND IT IS ONLY INTENDED TO SHOW AN OVERVIEW OF RENOVATION SCOPE OF WORK, WHICH DOES NOT INCLUDE MAJOR ARCHITECTURAL OR STRUCTURAL WORK, ONLY INTERIOR FINISHES. 2. ACCORDING TO INFORMATION PROVIDED BY THE OWNER, THE EXISTING BUILDINGS HAVE NOT BEEN MODIFIED SINCE THEY WERE ACQUIRED. CONSEQUENTLY, THE EXISTING CONDITIONS VERIFIED DURING SITE INSPECTION RENDERED BY THE ENGINEER ON MAY LOTH, 2017 ARE THE SAME AS ORIGINALLY. "THEREFORE, IT IS UNDERSTOOD THAT NO ADDITIONS, NO PLUMBING OR ELECTRICAL WORKS HAVE BEEN ACCOMPLISHED SO FAR FOR THIS RENOVATION PROJECT. 1:2,257 0 0.0175 a035 0:07 mJ 0 -:0.03 0.06 0.12 km SCOPE OF WORK / KEY NOTES ONE STORY- HOME 0 DEMOLITION OF SOME INFERIOR PARTITIONS. NEW '/" CONCRETE SHEET SUBSTRATE ON WALLS AND FLOOR OF BATHROOM. NEW CERAMIC TILE. 3� NEW V�" GYPSUM BOARD ON ALL INTERIOR WALLS AND CEILINGS, BUT KEEPING THE EXISTING WOOD SHEATHING. ® NEW TOILET AND SINK IN BATHROOM. 0 NEW STOVE AND SINK IN KITCHEN 6 NEW INTERIOR PAINT NO PLUMBING OR ELECTRICAL WORKS SHALL BE ACCOMPLISHED. SHED 1. NEW'/4" PLYWOOD FLOORING FASTENED TO EXISTING FLOOR DECK. 2. NO PLUMBING OR ELECTRICAL WORKS SHALL BE ACCOMPLISHED. 11'-621. EXIST. DOOR & WINDOWS SCHEDULE ITEM QTY. DIMENSIONS SPECIFICATIONS D1 1 36" x 80" OUTSWING EXTERIOR DOOR. MANUFACTURER: DOOR FABRICATION SERVICES, INC.. WOOD -EDGE STEEL OPAQUE SINGLE DOOR. LARGE MISSILE IMPACT RATED. DESIGN PRESSURE:+76/-76 PST D2 1 32" x 80" OUTSWING EXTERIOR DOOR. MANUFACTURER: DOOR FABRICATION SERVICES, INC.. WOOD -EDGE STEEL OPAQUE SINGLE DOOR. LARGE MISSILE IMPACT RATED. DESIGN PRESSURE:+76/-76 PSF D3 3 32" x 80" WOOD HOLLOW CORE INTERIOR DOOR W1 9 27" x 61" __— ALUM. SINGLE HUNG WINDOW. NO MARKS OR SPECS AVAILABLE. W2 5 27" x 52" ALUM. SINGLE HUNG WINDOW. NO MARKS OR SPECS AVAILABLE. W3 3 27" x 30" --------- --- ALUM. SINGLE HUNG WINDOW. NO MARKS OR SPECS AVAILABLE. 45-D° 33' F- — _ —_r.. --— — — — — — — — — — — — — — — I I I I I I I I I I I I I I I I o I I I I I I I I I I ® I I I I I I I ELEV. $T.LLC CuoUrV BU[LDLNGDIVISION REVIEW«DFORCO NCE THESE PLANS AND ALL PROPOSED WORK 1 REVIEWED BY ARE SUBJECT TO ANY CORRECTIONS DATE REQUIRED BY FIELD INSPECTORS THAT PLANS AN PERNfIT MUST BE KEPT ON JOB MAY BE NECESSARY IN ORDER TO 2 FLOOR PLAN OR NO INSPECTION WELL BE MADE• COMPLY WITH ALL APPLICABLE CODES. i f� S-4 SCALE: 3/8" = 1'-0" CONCEALED FASTENERS OR ATTACHMENTS N ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD w Iw w z � o =LL E U w U O U 6 N n' L i— y `'i J� N O t O R 67 N Q CO N @ > .. m I t c� �n w p E-� U W O O F'+ �+ U p N m � N (� �/� V J O Q N �p -o <u pco O 0� w a E- 6, W (o H L 00^ ,--I ClT N FV,,, .S-I U :4rl .o 03 � w r+ mot+ w° U H Design by: Date: ARTECH May 18/2017 DESIGNERS & ENGINEERS Drawn by: Date: C. CASTILLO May 18/2017 No, Revision Issue Date In this Page: Site Plan Floor Plan Scale: Details scale: f As Indicated I Engineer of record: Jairo Gonzalez, RE Florida Reg. License P.E. #66116 Job #: Sheet ml ADE-M-1117 S-1 Date: May 18/2017 of Check by: ip9 JAIRO GONZALEZ L (PECT'O_N BB_( CALE: 3/8" - 1'-0" N CONSTRUCTION FEATURES OF EXISTING HOME ITEM FEATURES STRUCTURE FOUNDATIONS CONCRETE BLOCKS. NOT VERIFIED. EXTERIOR WALLS STANDARD 2 x 6 FRAMED WALLS. FLOOR DECK 2 x12 FRAMEWORK @ 16" O.C. PARTIALLY VERIFIED. ROOF STRUCTURE RAFTERS, PURLINS AND RIDGE WOOD FRAMEWORK IN COMBINED GABLED SECTIONS SUPPORTED AND FASTENED TO EXTERIOR BEARING WALLS. ATTIC THERMAL INSULATION OVER CEILING (RATING NOT VERIFIED). TWO METAL GRIDS AT EACH SIDE OF THE HOUSE PROVIDES CROSS VENTILATION. EXTERIOR DOORS WOOD -EDGE STEEL STORM RATED DOORS. EXTERIOR FINISHES WALLS SHEATHING PLYWOOD FASTENED TO EXTERIOR WALLS. WEATHERPROOFING NOT VERIFIED. SIDING OVERLAPPED WOOD SLATES RUNNING HORIZONTALLY AND FINISH PAINT. CRAWL SPACE COVER OPEN DIAGONAL WOOD GRID SOFFIT ALUMINUM INTERLOCKED SLATES 50% VENTILATED THROUGH VENT SLATES ROOFING SHINGLE TILE ON PLYWOOD FASTENED TO ROOF STRUCTURE INTERIOR FINISHES FLOORING TONGUE & GROOVE WOOD FLOORING WALLS SHEATHING (R) 5 x 1 WOOD SLATES NAILED TO WALLS FRAMING CEILING (R) 5 x 1 WOOD SLATES NAILED TO CEILING FRAMING. NOT VERIFIED. BATHROOM (R) BARE FLOOR AND WALLS UNDER RENOVATION KITCHEN (R) BARE FLOOR AND WALLS UNDER RENOVATION. (R) UNDER RENOVATION NOTES: 1 - SEE KEYNOTES ON DWG. S-1, i 2 SECTION A -A z S-2 SCALE: 3/8" = 1'-0" ELEV. +17.50' ELEV. +15.50' ELEV. +11.38' ELEV. +0.00' 7 ELEV. +11.38' T-- w w z E z w = m R =W%mN E U w U J v Q CD N > to w � i c� w 0 O �+ U W Z O �+ U NO J') �H a > -� a ° c O o o o � �W ��r, EW°; �Q s~CN 0 ZUJ Q O oA d+�w° ID �C7wH Design by: Date: ARTECH DESIGNERS & ENGINEERS May 18/2017 Drawn by: Date: C. CASIILLO May 18/2017 No. Revision/Issue Date In this Page: Sections Construction Features Scale: Details scale: As Indicated Engineer of record: Jairo Gonzalez, P.E Florida Reg. License P.E. #66116 'LICE •�-9'i * . Nos s' 6 m, ,! TATF OF Q tSj'' RID P, ob #: Sheet ADE-M-1117 S-2 Date: May18/20 IJ, Check by: 2 JAIRO GONZALEZ