Loading...
HomeMy WebLinkAboutProduct Approval File COpy. �5 2p3tiftt2iltd BCIS Home Log to l User Registration Hot:Topics Submit Surcharge Stats&Facts ( Publications E FBC Staff I SC1S Site Flap Links i Search 3 sines (�J� Professil`II Product Approval USER:Public User Regulation R E CV 7 V Product Aooroval Menu>Product or Application Search>'appitcation List>Application Detail FL# FL9777-R7 MAY 0 lit 2@ 1? Application Type Revision Code Version 2014 P�f?i.ii` i`! 1; Application Status Approved CGNCEAUD FASTENERS'OR AT(e("'HMENTS Comments l�tlll ARE T IE R"ISCbONSIBI ��I F NE Archived i1.'JF lR -.069 Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledor OH_43659 �����1= iti5 A�v� �L PROPOSED WORK (740)404-7829 greg.keeler@owenscorgiMEtteU�J L �'iI O ANY CORRECTIONS Authorized Signature Greg Keeler }�S �IRra®BvTH F'CLD 6VECT®IS THAT greg.keeler@owensto �.B5 NECESBARY IN ORDER TO Technical Representative ®' '1"8m9.ti � �I' ��CA�Ia CODES.'' Address/Phone/Email s�J'C�-( � ST.LI1Cr���TTJIa" err Drs;;n D� S�© Quality Assurance Representative �F i RR D R D'2LIANCE Address/Phone/Email HL'M"�'_�� ;`� DA TL "S AND PFRrviiT RUST BE KEPT()N JOB Category Roofing GP_NO EiSPECTION WILL���r�,D32a Subcategory Undertayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden Y; Validation Checklist-Hardcopy Received Certificate of Independence F19777 R7 COI OCR14002 as F---BC 2014 EvaluatiM R oort W atherlock Lyon-HVHZ-final.odf Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/19/2016 Date Validated 04/20/2016 Date Pending FBC Approval 04/21/2016 Date Approved 06/08/2016 Summary of Products FL# Model,Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use . Installation'Instructions Approved for use in HVHZ:No FL9777 R7 II OCR14002.4A FBC 2014 Evaluation Report Approved for use outside HVHZ_ Yes Weatherlock No2HVHZ-final.odf impact Resistant:N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes they.See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002:4A FBC 2014 Evaluation Report Weathercock Non-HVHZ-finai.pdf Created by Independent Third Party:Yes 9777.2 Weatherlock MAT Waterproofing Underlayment Limits of Use . Installation Instructions Approved for use in HVHZ: No FL9777 R7 lI OCR14002.4A FBC 2014 Evaluation Repors Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.pdf Impact Resistant:N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002 4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final.odf Created by Independent Third Party:Yes 9777.3 Weatherlock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 R7 II OCR14002AA F8C 2014 Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.odf Impact Resistant.N/A Verified By: Zachary R. Priest PE-74021 Design,Pressure:N/A Created by Independent Third Party: Yes Other See evaluation report for limits of use. Evaluation Reports FL9777-R7 AE OCR14002 4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final.odf Created by Independent Third Party:Yes 9777.4 Weatherlock Metal Weatherproofing Underlayment Limits of Use. Installation Instructions Approved for use In HVHZ:Yes 81777 R7 II OCR24002.4B FBC 2014 Evaluation Report Approved for use outside HVHZ:No Weatherlock Metal VHZ-final.odf Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002 48 FSC 2014 Evaluation Report Weatherlock Metal HVHZ-final.pdf Created by Independent Third Party:Yes 9777.5 WeatherLock Specialty Tile&Metal Weatherproofing Underlayment Limits of use Installation Instructions Approved for use in HVHZ:No FL9777 R7 II 0CR14002 4A FBC 2M A vac ration Rgp Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.odf Impact Resistant:N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-105 Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002 4A FBC 2014 Fvaluation Report Weatherlock Non-HVHZ-final adf Created by Independent Third Party:Yes Bach Next contact Us::.1940 North Monme Street,Tallahassee FL 32399 Phone:s50-4w-1824 The State of Florida is an AA/EED employer,Convdoht 20V-2013 State of Florida..::Privacy Statement::Accessiblilty statement;.-Rerund Statement Certificate of Authorization No. 29824 CREEKM20 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, L.L,G (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE r EDITION.(2014) Manufacturer. OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016 1 Owens Coming Parkway Toledo,OH 43667 (800)438-7465 www.owenscomino.00m Manufacturing Location: Brentwood,NH Quality Assurance: UL LLC(QUA9625). SCOPE Category: Roofing Subcategory: Undedayments Code Sections: -1504.3.1,1507:2.4, 1507 2.8,1507.2.9.2,1507.3.3,1507.4.5,1507.4.5.2, 1507.5.3, 1507.5.3.2,1507.7.3,1507.7.3.2 Properties: Physical:properties REFERENCES Enti ' Report.No. Standard Year PRI Construction Materials Technologies(TST6049) NEI-039-02-01. ASTM Q 1970 2009 PRI Construction Materials Technologies(TST6049) NEI 042=02-01 REV2 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155. 2005a PRI Construction Materials Technologies(TST6049) NE1-06"2-01 TAS 163 1995 PRI Construction Materials Technologies(TST6049) NEI-053=02-01 ASTM G 155 2U05a PRI Construction-Materials Technologtes.(TST6049) NEI-09'M2-02 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) 0CF-213-02-01. ASTM D 1623 2069 PRI Construction Materials Technologies(TST6049). OCF-237-02-'01 UL 1897 2004 PRI Construction Materials Technologies(TST5878) OCF-252-02-61. , ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM 01970 2009 PRi Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) OCF-272-02-01 TAS 103 1995 PRODUCT DESCRIPTION AND Ltws,oF USE, WeatherLock®G WeatherLock®G is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and.surfaced with granules. The product is supplied in 2-sq,rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock®G is pemiitted to be used with mechanically fastened asphalt shingles, Wood shakes or shingles, and slate roofing as-prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock®Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq.rolls with'nomind dimensions of 3-ft x 33.3-ff and 2 sq.rolls with nominal dimensions of 3-ft x 66.77ft. WeatherLock@ Mat is permitted.to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002AA FL9777-117 Page 1 of 4 This evaluation report rovi is pded for State of Florida product approval under Rule 69G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,.recommended use,or other product attributes that are not specifically addressed herein: 0 • REEK OWENS CORNING ROOFING AND ASPHALT LLC i1 [�► WeatherLock@ Self-Sealing Ice&Water Barriers TECHNICAL.SERVICES,LLC WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass.mat reinforcement and plastic film surface. The product is supplied in 2.0 sq.rolls with nominal dimensions of 34 x 66.7-ft. WeatherLock® Metal 'is permitted to be used with mechanically fastened asphalt shingles;metal roof panels or shingles,wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric. The product is supplied in 2.14 sq,rolls with nominal dimensions of 3-ft x 71.3-ft. WeatherLock@ Specialty Tie&Metal is permitted to be used with mechanically fastened asphalt shingles; clay or concrete tile, metal'roof panels or shingles, wood shakes or shingles, and slate roofing as'prescribed In.the FBC. WeatherLack@ Specialty Tile & Metal is permitted to be..used With;adhered clay or concrete tile roofing using either 3MTM 2-Component foam Roof Tile Adhesive AH-160(3M Company) or TILE,BONDTM Roof Tile Adhesive(The Dow Chemical Company).;Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete'tile installations without battens.. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall-not be stacked greater.10 tiles per stack.. PRODUCT APPLIcArO'N Min.Roof Slope: 2:12 or in accordance in with.FBC Application: Deck substrates shall be clean, dry', and free from any irregularities and debris. All fasteners in the deck shall be'checked for protrusion.and corrected prior to underlayme' nit application. Prior to, beginning installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The undedayment shall be installed with the release backer removed and pressed firmly Into place to ensure complete contact with the.deck. The undedayment shall be installed with the'roll`length parallel to the eave, starting at the eave, and with minimum 3"side laps and minimum-6" end laps staggered, 64 from preceding course. End laps for WeatherLock@ Specialty Tile&Metal shall be primed with ASTM D 41 primer or sealed with as haltroof cement-a minim urn um of 3-4 inches across the width of the lap. It is permissible to nail the'underlayment 18-inches on-center as needed (nails shall be Installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). WeatherLock@ Specialty Tile & Metal shall be back nailed when • installed on roof slopes greater than 3:12. For valley applications, the roil shall be applied centered along the valley prior to installing the underlayment at the eave. For eave protection,the underlayment should extend to a point 24-inches inside the exterior wall. The underlayment shall be installed over metal drip edge at the eave,and under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the drip edge in accordance Section 1507.2.9.3. Min.Application 40°F;Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. OCR14002AA FL9777-117 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation,recommended use,or other product attributes that are not specifically addressed herein. J 0 oCREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatherLoctc®Self-Sealing Ice&Water Barriers TECHNICAL SERVICES,LLC WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 21 margin of safety per FBC Section 1504.9. Underlayment System No.1 Roof Deck: Min. 15i32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: WeatherLockO Specialty 'Tile .8 Metal shall be 'applied in accordance with manufacturer's installation,instructions to the fastened deck and backnalled along the selvage with'minimum 12ga., 1-1I4-inch;galvanized ring shank roofing nails through optionally--primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied undedayment'shalt be rolled with,a minimum 751b steel roller immediately following application. Maximum Design -105 psf Pressure: GENERAL.LIMITATIONS 1) This evaluation report is not Use'in'the HVHZ.. . 2) Fire Classification is not within the scope-of this evaluation. 3) Installation of the;evaluated product shall comply witfithis report;the FBC,and the manufacturer`s published application instructions. Where discrepanctes exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck.shall be'constructed of closely fitted plywood sheathingfor new or existing construction. 5) The space under the deck area shall'be properly ventilated in-accordance.with the FBC requir,ements. 6) All.side lap searns shall be installpflo shed water from the deck. 7) The undedayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall,tie determined for components and cladding in accordance with FBC 1609.` 9) The roofdeck shall be designed by others in accordance with FBC requirements to resist the design wind load'pressures for components and cladding: 10) Maximum Design Pressures for a given underlaymenf shall meet or exceed the design wind loads determined,for-the roof assembly. 11) All products listed in this report'shall be•manufactured under a quality assurance program in compliance with Rule 61G20-3 . OCR14002.4A FL9777-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. J � • MCREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatherLockO Self-Sealing Ice&Water Barriers TECHNICAL SERVICES,LLC COMPLIANCE STATEMENT - The products evaluated herein by Zachary R. Priest,-P.E.have demonstrated compliance with the Florida Building Code 5a'Edition(2014)as:evidenced in the referenced documents submitted by the-named manufacturer. *,,*` Y 2016.Q4.19 No 74021 '•: f 15: 51 :11 * a.� ,.. —Q410,0 I �'.. STATE OF :�% �'�'�•'�'c� Zachary R.Priest,P.E. Florida Registration No.74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC doesnot have,nor will it acquire;a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Servicesi LLC is not owned,operated,or controlled by-any company manufacturing or distributing products under this evaluation. ZacharyR.Priest, P.E.does not have; nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will.acquire,a financial`interest in.any other entity involved in the approval process of the product. END OF REPORT OCR14062.4A FL9777-R7 Page 4 of 4 This evaluation report is provided for State of Florida product.approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes'or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express-nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.