Product Approval Menu>Product or Application Search>Appl—t;-List>Appliotbn Detall
FL# FL5259-R25 CO,NTNAOTOR OF REGORD
' Application Type Revision
Code Version 2014
Application Status Approved
Co hived THESE PLANS AND ALL PROPOSED WORKArchived
Product Manufacturer POLYGLASS USA =ARE SUBJECT TO ANY CORRECTIONS
Address/Phone/Email Fernley,Lyon
Fe NVV 89408 REQUIRED BY FIELD INSPECTORS THAT.
(570)384-1230 Ext 242 tr.
jakins@polyglass.com ` �r MAX BE NECES8,ARY:{N,ORDEP TO.
Authorized Signature James Akins 1,Cj®�j�!Y 1pf ff IiilSFar1`a��j L�L7A�pa K� •i
jakins@polyglass.com .s• •.., .. ,.
Technical Representative Steve Wadding —�
Address/Phone/Email 150 Lyon Drive
Fernley,NV 98408 V V
63-7139
ste�e @poly9 ass.com COT.L IT r�,' COT—TNTI%BTJI?P?1jG DIVISION
Quality Assurance Representative James Akins EVFE WE
Address/Phone/Email Humboldt Industrial Pkwy DATE
Hazleton,PA 18201
(800)894-4563 PLA\TS AND PEWCII�'MUST BE KEPTONJOB
jakins@poly9lass.com • OR NO INSPECTION WILL BE W01,Eua
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
—;Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Robert Nleminen
Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/24/2018
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL5259 R25 COI 2016 01'COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D226 2006
ASTM D6164 2005
ASTM D6222 2008
" ASTM G154 2006
ASTM G155 2005
FM 4474 2004
FRSA/TRI April 2012 2012
TAS 103 1995
UL1897 2004
Equlvalence of Product Standards
Certifled By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/17/2016
Date Validated 10/18/2016
Date Pending FBC Approval 10/19/2016
Date Approved 12/15/2016
Date Revised 03/13/2017
Summary of Products '
httDs://www.floridabuildina.or2/-Dr/-Dr am dtl.aspx?param=wGEVXQwtDcivbSaAaZp3Cr... 4/26/2017
Florida Building Code Onlin� S Page 2 of 2
FL# Model,Number or Name Description
5259.1 Polyglass Roof Underlayments Roofing underlayments
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL5259 R25 II 2016 10 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside HVHZ:Yes R25.odf
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes
Other:1.)The design pressure in this application relates to one particular Evaluation Reports
underlayment system(over concrete deck)for use under foam-on tile systems FL5259 R25 AE 2016 10 FINAL FR POLYGLASS UNDERLAYMENTS FL5259-
(where the underlayment forms part of the load-path).Refer to ER Section 5.6.4 for R25,Ddf
other systems,other deck types and assoclated maximum design pressures.2.) Created by Independent Third Party:Yes
Refer to ER Section 5 for other limits of use.
T
Back Ncat
sl
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:950-487-1824
The State of Florida Is an AA/EEO employer. orida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law, mail addresses are public records.Iryou do not want you man address,.leased in response to a pabnc-r rds mq—,do not and electronic mail to this entity.Instead,contact the once by phone or by
traditional man.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,affective October 1,2012,licensees licensed under chapter 455,F.S.must provide the Department
- with an email address If they have no.The smalls pm lded may be used for offidal communication with the licensee.However..all addresses are public record.If you do not wish to supply a personal address,plaesa provide
the Oeparment with an email address which can be made available to the public.To determine it you area licensee under Orapter 455,FS.,plaesa click here.
Product Approval Accapta:
Credit Card
Safe
r
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Cr... 4/26/2017
EXTERIOR RESEARCH&DESIGN,LLC.
` Certificate of Authorization#9503
t 3.53 CHRISTIAN STREET,UNIT#13
TRiNI`i'Y I ERD OXFORD,CT 06478
PHONE:(203) 262-9245
FAX:(203)262-9243
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-R21
150 Lyon Drive FL5259-1125
Fernley,NV 9840.8 Date of Issuance:02/24/2009
Revision 21:10117/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed.by Robert Nieminen, P.E.
for use of the product under .the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5th Edition..(2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited.QualityAssurance.Agency noted herein.
CONTINUED:COMPLIANCE: This Evaluation Report is valid until such time as the lamed product(s) changes, the.referenced
Quality.Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert.Nieminen,P.E:if the.product changes or the
referenced Quality Assurance documentation changes. Trinity ERD requires,a complete review of this Evaluation Report
relative.to.updated.Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERE) Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
dlistributors and shall be available for inspection at the job site at the request of th.e_Building Official..
This Evaluation Report consists of pages 1 through 13.
Prepared.by:
= y= The facsimile.seal.appearing was authorized by Robert Nieminen,
- &'.,-`-",�` P.E.on 10/17/2016.This does not serve as an electronically
Robert J.M.Nieminen P.E. •T' `� : ��,��` �, signed document. Signed,sealed hardcopies'have been
Florida Registration No..59166,Florida DCA AN, 983 transmitfed:to the.PrddUct Approval Administrator.and to the
named.dierit
CERTIFICATION OF.INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to.acquire or will it acquire, a fna.ne at interest;in.Any company manufacturing or
distributing products it evaluates.
2. Trinityi ERD is not owned,operated or controlled by any company manufacturing or distributing.:products it evaluates..
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
wh►ch.the,evaluation reports are being issued.
.4. :.Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a.building code evaluation. Neither Trinity i ERD'nor Robert Nieminen,P.E.are;in any way,the Designer of Record for ariy
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting:.or design.guidance unless retained
.specifically for that purpose:
TRINITY!ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
R
Product Category: Roofing
Sub-Category: Under"layment
Compliance Statement: Roof Underlayments, as produced by Polygiass USA, Inc., have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance.is
subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS: a.
Section :Pro p ertV Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1504.3.1 Wind Uplift UL 1897 2004
1504.E Accelerated Weathering ASTM G154 2006
1504.6 'Accelerated Weathering ASTM G155 :2005
1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physjcal.Properties ASTM D226 200E
1507.8.3,1507.9.3
1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009
1507.11.2 Physical Properties ASTM D6164 2005
1507.11.2 Physical Properties ASTM D6222 2008
1507.3.3 r installa bri:13ractice FRSA/TRI April 2012 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
FM Approvals(TST 1867) Wina.Uplift 3004091 01/12/2000
PRI(TST5878) PhySical.:Properties PRIO1111 04/08/2002
PRI(TST5878) Phys)cafProperties PUSA-005-02-01 01/31/2002
PRI(TST5878) Physical PropertiesPUSA-013-02-01 12/23/2002
PRI(TST5878) :;Physi%ca1.l-Properties PUSA-013-02-02 12/23/2002
PRI(TST5878) Physical:Properties PUSA-013-02-03 12/23/2002
PRI(TST5878) `Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST5878) -hysical.Properties PUSA-028-02-01 .07/13/W05
PRI(TST5878) Physica(P..foperties PUSA-033-02-01 01/12/2006
PRI(TST5878) PhysicalProperties PUSA-035-02-01 05/29/2006
PRI(TSTS878) physic.(Properties PUSA-055-02-02 12/10/2007
PRI(TST5878) Physical;Propertl_es PUSA-061-02-02 01/28/2008
PRI(TST5878) Physical,Propert'ies PUSA-076-02-01 02/22/2008
PRI(TST5878) Physical Properties PUSA-083-02-01 04/14/2008
PRI(TST5878) Physical.-Properties PUSA-088-02-01 07/29/2009
MTI(TST 2508) Physical:Properties JX2OH7A 04/01/2008
MTI(TST2508) Physi0l*Propeities RX14E8A .01/29/2009
ERD(TST-6049) Physical Properties 11752.09.99-1 :02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049.) :Wind:Uplift 11776.06.02 01/16/2003
ERD(TST 6049) :"2 Physical:Pr.perties 02200.07.03 07/14/2003
ERD(TST 6049) Win
41)plift P1740.01.07 Ol/04/2007
ERD(TST 6049) ;Physica(;Properties" P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind:UPlift P9260.03.08 03/21/2008 .
ERD(TST 6049) a Physical Properties P13450.08.09 08/13/2009
ERD(TST 6049) Wild.Uplift P.30540.11.09-111 11/30/2009
ERD(TST-6049) Physical.Ptpperties P11030.11.09-1 1.1/30/2009
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30J2009
ERD(TST 6049) physical_ProperEies" P11030.11.09-3 '11/30/2009
ERD(TST 6049) PhyslcalProperties P33360.06,10 06/25/2.010
Exterior Research and Design,LLC.. Evaluation Report P12060:02.09-R21
Certificate of Authorization/f9503 FBC NON-HVHZ EVALUATION FL5259-RZ5
Revision 21:10/17/2016
.Page 2 of 13.
``4.t
� TRINITY,ERD
Enti Examination Reference _Date
ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2611
ERD(TST 6049) Physical Properties P37300.10.11 ].0/19/2011
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/.2012
ERD(TST 6049) Physical Properties C41420.09.12-3 b9/11/2012
ERD(TST 6049) Wind Uplift 039680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370:04.13 '04/26/3013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 OS/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11%26/2013
ERD(TST 6049) Wind Uplift P.11781.11.03-R1 1]/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD.(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 b§/dg/2614
ERD(TST 6049) Physical Properties 6020.09.14-3 .09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/.08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/OS/20.14
ERD(TST 6049) Physical Properties 6020.09:14-6 09/O9/2014
ERD(TST 6049) Physical Properties P46520:10.14 10/03/2014
ERD(TST:6049) Physical Properties P44360.10.14 :.'.10/07/2.014
ERD(TST60.49) Physical Properties P.43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/ZO1S
ERD(TST 6049) Physical.Properties P40390.04.15 04/03/2015
ER.D(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 `'07/16/2016
ERD.(TST 6049) Wind Uplift P LYG-SC12025.10A6 10/12/2016
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/Ol/2014
Miami-Dade(GER 1592). HVHZ Compliance NOA 14-0717.08 01/22/2015 .
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass U5A P/L Affidavit Mule Hide Cross Ltg 03/01/2008
Polyglass.USA Materials Affidavit Polystick SA Compound .`W18/2011
UL,LLC.(gUA962S) Quality Control Service Confirmation Exp.04/24/1018.
4. PRODUCTDESCRIPTION'
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase.is a:fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P.is a-.polyester-reinforced,SBS modified bitumen base sheet.
44.1.a. :Polyglass G2 Base is a fiberglass-.reinforced'asphaltic base sheet.
4.1.4 *Po lyglass APP.Base:is afiberglass-reinforced,APP modified bitumen base:sheet..
Self-Adhering Underlayments:
4.2.1 Polystick.MTS is a nominal 60-mil thick rubberized asphalt Waterproofing membrane;glass fiber.reinforced,surfaced
with polyolefinit.film surface;:meets ASTM D1970 and TAS 103.
4.2.2 Tolystick:MTS PLUS is a:nominal 60-mil thick rubberized asphalt waterproofing.membrane; glass fiber reinforced,
'surfaced-with.poly-film surface;meets TAS 103.
4.2.3 .Polystick IR-Xe is a.nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with.an.
aggregate surface;meets.ASTM D1970.
Exterior Research and Design;LLC Evaluation Report P12060.02.09-R21
Certificate of Authorization J�9503 F.BC NON-HVHZ EVALUATION .FLS259-R25
Revision 21:10/17/2016
Page 3 of 13
-TRINI� ERA
4.2.4 Polystick TU Plus is a nominal 80-mii thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface;meets ASTM D1970 and TAS 103.
4.2.6 :Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/mz polyester
fabric surface;meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-HideSA-APP Cap Sheet (FR) are polyester
reinforced,APR modified bitumen cap sheets;meet ASTM D6222.
4.2.8 Polystick.Dual Prot"'' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
.reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.9 Polystick Tile ProTM' is a nominal 60-mil thick dual-layer rubberized asphalt, waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.10 .Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
teinforeed,with a;polypropylene film surface;meets AC188 and physical requirements of ASTM D1970..
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 :Elastoflex.S6 G.and Elastoflex S6 G FR are polyester reinforced,SBS modified bitum.en.cap sheets;meet ASTM D6164.
4.3.2 Polyflex G and Polyflex G.FR are polyester reinforced,APP modified bitumen.cap sheets;meet ASTM.D6222..
5. LIMITATIpN5:
5.1 This:is a building code evaluation. Neither Trinity l ERD nor Robert Nielninen,!PE. are, in.anyway; the Designer of
..,Record for any project on which this Evaluation Report, or previous versipns.thereof,is/was used,for permitting or
design guidance:unless retained specifically for that purpose.
5.2. , " This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved.Rogf)ng Materials Directory for fire
W.
ratings of this product.
5.4 'Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made .to:the Authority Having'Jurisdiction for
;approval based on this evaluation combined with supporting data for.the prePared.roof covering.
5.5 Allowable Roof Covets-,
y ` ` TABLE 1 ROOF 6:)vi OP.TJONS
Wood Shakes.&
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Shingles Slate
Yes Yes
Elastobase Yes (base sheet In 2-ply Ibase sheet In 2-ply YES Yes Yes
system) system)
r Yes Yes
Elastobase:P Yes (base sheet In 2-ply (base sheet in 2-ply Yes Yes Yes-
.. ........ . .. . .. .. system) system)
Yes Yes
_ POlyglass.Ci,2 Base No (base sheet in 2-ply (base sheet in 2-ply _ .' .:.No' No No
system) system)
Yes Yes
P.olyglassAP.PBase No (base sheet ln2-ply (base sheet ln2-ply NO.: NO No
system) system)
Polystick MTS Yes Yes No Yes Yes Yes
Polystick MTS PLUS. Yes Yes No Yes Yes -Yes
Polystick IR-Xe Yes No No No' yes Yes
...........
.....:.. ............. .... .
PolystickTU P Yes Yes Yes See 5S.1 No Yes., Yes
PolystickTU Plus Yes Yes Yes Yes Yes Yes
See 5.5.1
Exterior Research and Design,'LLC. Evaluation Report P12060:02.09-R21
Certificate ofAuthorizotion#9503 FBC NON=HVHZ EVALUATION FL5259-R25
Revision 21:10/17/2016
Page 4 of 13
4 } TRINITY ERD
Underlayment Asphalt5hingles Nail-OnTlle Foam-On Tile Metal Wood Shakes& Slate
Shingles
Polystick TU Max No Yes Yes See 5.5.1 Yes No No
Polystick Dual Pro Yes Yes No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes See 5.5.1 Yes Yes Yes
Polystick MU-x Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes No Yes Yes
See 5.5.1
Elastoflex S6 G FR Yes Yes No No Yes Yes
Polyflex G Yes Yes Yes No Yes Yes
See 5.5A
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes
See 5.5.1
Mule-Hide SA-APP Cap Sheet Yes
Yes Yes No Yes Yes '
or SA-APP Cap Sheet(FR) See 5.5.1
5.5.1 "Foam-On.Tile" is limited,tq.use:of th:e following Approved tile adhesives unless tensile adhesion/long term aging
4.data from an accredited testing laboratory is provided.
✓ 3M1 2-Component.Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max;
Elastoflex S6 G, Polyflex_'G,.Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP
Cap Sheet(FR)orTile Pfo:..:'
✓ 3M1 Foam Roof Tile Adh 1 a RTA-1.(FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max,Elastoflex S6
G,Polyflex G, Polyflex:SAP;Polyflex SA.Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
or Tile Pro
✓ Convenience Products'Touch.`n Seal:Stormoond Roof Tile Adhesive(FL14506): Polystick TU Plus, Polystick TU
Max.
✓ Dow TIIeBond(FL717):.Polystick:TU P,.Polystick TU Plus,Polyflex SAP or Tile Pro.
✓ Polyglass PolyLok Roof Tile Adh:esive.(FL17855): Polystick TU Plus or Polystick TU Max.
Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations),D.ual,Pro,Tile Pro,Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap.Sheet
(FR)self-adhered to: .
➢ New untreated.plywood;,ASTV D41 primed.new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, ;unpr'imed DSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine.;..ASTM..D41.primed structural concrete; Huber Engineered Woods "ZIP System"::Panels
(designed and installed:to:meet-lho.loads,for project).
Note.:Polygldss does not regyre priming of new or existing plywood or OSB sheathing. New or existing plywood or . .
OSB sheathing should be.cleaned.of all.dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G FR.in_hot asphalttoc. :
ASTM D41 primed structural concrete. .
Polyflex G or.G FR torch-applied.to:
➢ ASTM D41 primed structural.cogetete... '
Exterior Research and Design,I.I.C. Evaluation Report P12060.02,09-R21
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION 'FL5259-R25
Revision 21:10/17/2016
Rage of13.
�4I TRlNITY'ERD
5.6.2 Bond-to-Insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP.Cap Sheet or SA-APP Cap Sheet(FR)self-adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard;Dens Deck Prime;.or SECUROCK Gypsum-Fiber.Roof Board.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or G FR torch-applied to:
➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof.coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product:Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified.design.professional_and installed based.on testing of
the insulation/underlayment system in accordance with FBC Section 15'04.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP:Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P or lvlule-Hicle:IVail Base:
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or 11 felt;Elastobase;Elastobase P,Mule-Hide Nail Base.or Polyglass G2 Base.
Polyflex G or G FR torch-applied to:
➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base.or,Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base:layer.shall be attached per minimum
codified requirements. For installations under foam-on.the systerhs, base:layer.shall be attached per minimum.
requirements of FRSA/TRI April 2012(04-12),Appendix A,Table'1,or as listed in.Section 5.6..4 herein,or as tested in
accordance with FBC Section 1504.3.1.
5'.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications:. EftSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems.beneath foam=qn. tile.systems, where the underlayment
forms part of the load-path. The following wind uplift limitations. apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and.are used in foam-on the applications. Maximum Design Pressure is the
result of testing for wind load resistance based on.allowable..:wind.loads;and reflects the ultimate passing pressure
:divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has.already been applied).Refer to FRSA/TRI April 2012 (04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads..
5.6.4.1. Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction_of Authority.Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR;Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet:project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM.D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polysfick TU P,Polystick.TU Plus,Polystick TU Max,Rolyflex.SAP,Polyflex:SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within.the selvedge-edge side laps using 12 ga.x
1%"ping shank nails through 32 ga.,1-5/8".diametertiin caps.spaced 12-inch o.c.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R21
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-RZ5
Revision 21:10/17/2016
Page 6 of 13
! +i
` TRINITY 11 ERD
I
5.6.4.3 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to.meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.and back-nailed within the selvedge-edge side laps using 12 ga.x
1Y."ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements.to satisfaction of Authority Having Jurisdiction.
Primer: (Optional.)PG100 or°ASTM D41 .
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional)Polystick MTS PLUS;self-adhered
Underlayment:Polystick TU P,Polystick TU Plus;PolystickTU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet;(FR),self-adhered.
5.6.4.5 Maximum Design Pressure='-315 psf
Deck: Structural concrete to meet project requirementsto.satisfaction of Authority Having Jurisdiction.
Primer: PG100 orASTM D41
Base Ply: (Optional)P6lystick:MTS PLUS,self-adhered
Underlayment:Polystick TU P, Polystick TU Plus,.Polystick TU Max,Tile Pro,Polyflex SAP.,Polyflex SAP FR,Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet.(FR),self-adhered.
5.6.4.6 Maximum Design Pressure=.=622.5 psf: ..
Deck: Structural concrete to meet project requirements tosatisfaction of Authority Having Jurisdiction.
Primer: :PG100 orASTM D41
Underlayment:Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.7 Maximum Design Pressure=-30X:psf*: .
Deck: Min.15/32-in.ch OSB to meet project requirements to:satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail:Base.(poly=film top surface)
Fasteners: .11 ga.x 1:25-inch long x 1-inch head.dameter round metal cap nails
Spacing: 6-inch ox.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced.staggered center rows.
Base Ply: (Optional)Polystick MTS,PLUS;:self-adhered
Underlayment:PolystickTU P,Polystick TU Plus;Polystick TU.Max,.Polyflex SAP,:Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap'Sheet(FR),self=adhered.
5.6.4.8 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood tq:meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase.or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x.125-inch long k 1-inch head diameter round metal cap nails
Spacing: 61-inch o.c.at the 3-inch wide:side laps and 6-inch ox.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick:MTS PLUS,:self-adhered
Underlayment:PolystickTU P,Polystick.TU Plus;PolystickTU Max,Polyfla SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule Hide SA-APP.CapSheet(FR),self-adhered.
5.6.4.9 Maximum Design Pressure= 37.5 psf*c.
Deck: Min.19/32-inch plywood to meet project requirements to.satisfaction of Authority Having Jurisdiction.
Base Sheet: One..(1)or two(2)layers ASTM D226,Type 11 felt
Fasteners: 11 ga.x I.25-inch long x 1-inch.head.diameter round.metal cap nails
Spacing: 6-inch o.c.at the 37inch wide side laps and 12-41ch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflez.56 G,appdllmfhot asphalt..
Exterior Research and Design,LLC. Evaluation Report P.12060.02.09-R21
Certificate of Authorization#9503 FBG NON-HVHZ EVALUATION FL5259-1125
Revision 21:10/17/20.16
Page 7 of 13
J TRINITY;ER®
5.6.4.10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASfM D226,Type II felt
Fasteners: 11 ga,x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex S O,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex 5.6 G,applied in full mopping of hot asphalt.
5.6.4.11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASiM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch,o.c:at two.(2)-equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayrrieht.only)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus;Polystick`TU Max;Polyflex 5AP,.Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self.-adhered or Elastoflex Sfi G,applied in full.mopping of hot asphalt.
5.6.4.12 Maximum Design Pressure=-45 psf:
'.Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt ortorch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c:at two.(2j equally spaced staggered center rows. .
Underlayment:Elastoflex S6 G,applied in full mopping of.hot asphalt o�Polyflex.G,torch-applied.
5.6.4.13. Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
:Base Sheet: Elastobase(sanded top surfacefor hot-asphalt ortorch-applied cap.or poly-film surface for torch-applied carp)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-'1rich o.c.at two.(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
8.6.4.14 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
:Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 64nch o.c..atfour(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.15 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements.to satisfaction of Authority Having Jurisdiction:
Base Sheet: Elastobase(sanded top surface for hot-asphalt or*torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 34nch wide side laps and.6-inch o.c.at four,(4)_equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex Gtorch-applied.
5.16.4.16 ..Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements.tosatsfaction:of Authority.Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt ortorch=applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameterannular ringsha.nk roofing nails at 1-5/8-inch.diameter tin caps
Spacing: 8-inch o.c.at the flinch wide side laps and 8-.inch o.c.at three(3),equally spaced staggered center rows.
.Underlayment:Elastoflex S6 G,applied in full mopping_of hoi_asPhalt o.r Polyflex G;torch-applied.
Exterior Research and Design,I.I.C. Evaluation Report P.12060:02.09-R21
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1125
Revision 21:10/17/2016
Page 8 of 13
"lit TRINITY ERD
5.6.4.17 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
_ -Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied,.
5.6.4.18 .Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: :Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: :12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 175184nchAiam.eter-tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
.Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G;torch-applied.
5.6.4.19 .'Maximum Design Pressure=-75 psf:
:Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.,
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applled underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel.Palates,OMG.Roofgrip 414 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
:Spacing: 10-inch.o.c.at the 4-inch wide side laps and 10-Inch o.c.at three(3)equally spacedstaggered_center rows. .
Underlayment:.ElastoflexS6 G,applied in full mopping of hot asphalt or torch-applied'or Polyflex G,torch-applied.
5.6.4.20. ::Maximurn Design.Pressure=-90 psf:
;Deck; Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having:Jud diction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied captor poly-film surface for torch=applied cap)
':Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-Inch o.c.at two(2).equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. .
5.6.4.21 ;Maximum Design Pressure=-90 psf:
;Deck: Min.15/327inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
:Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap.or poly-film,surface for.torch-applied ca.p)
.Fasteners:. 'OMG.#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates.or OMG Flat Bottom Metal
.Plates
;Spacing 64nch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced.staggered.center rows.
Underlayment:Elastoflex S6 G,applied:in full mopping of hot asphalt or Polyflex G;torch-applied
5.6.4.22 :Maximum Design Pressure=-90 psf:
;Deck: . Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Haying Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6=inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center tows. .
Underlayment:,Elastoflex SG G,applied in full mopping of hot asphalt.
_ 5.6.4.23 .;Maximum Design Pressure=-90 psf:
peck; Mip.15/32-inch plywood to meet project requirements to satisfaction of Authority Haying Jurisdiction.
',Base Sheet:. . :'Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfasi#14 with Dekfast.Hex plates,OMG#14.HD with OMG 3"Galvalume Steel.Plates;OMG:Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 37inch Insulation*Plates or Simplex MAXX:Cap
Fasteners
Spacing: 9-inch o.c.at the 4-inch wide.side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G;torch-applied.
Exterior Research andDesigni LLC. Evaluation Report P12060.02.09-1121
CertiFcatg of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-825
Revision 21:16/17/2016
:Page 9 of 13
I
5.6.4.24 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga..x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c,at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP.Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.25 Maximum Design Pressure=-105 psf:
Deck: 'Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for.torch-applied cap)
.Fasteners: Simplex.MAXX Cap Fasteners
Spacing: 64nch o.c,at the 24nch wide side laps and 6-inch o.c.at three(3)equally spaced staggered:center rows.
Underlayment;ElastoflexS6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.26 Maximum°Design Pressure=-112.5.psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base.Sheet: Elastobase.or Mule-Hide Nail Base(poly-film top surface)
Fasteners:_ 11 ga.is 1.25-inch.x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-'inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered.center.rows.
Primer: PG100 orASTM D41 primer at all tin-caps
Base:Ply: Polystick MTS PLUS,self-adhered'
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR;Mule-Hide SA-APP Cap Sheet and
Mule-HideSA-APP Cap Sheet(FR),self-adhered.
5.6.4.-27 Maximum Design Pressure=-120 psf:
.Deck: Min.15/32-inch plywood to meet project requirements tosatisfaction of Authority Having Jurisdiction.
Base Sheet:: ...Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface`foi torch-applied cap)
Fasteners: ::OMG#12 Standard Roofgrip or OMG 1#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
:.Plates
Spacing: 64nch o.c.:at the 4-inch,wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows._
Underlayment:ElastoflexS6.G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.28 .Maximum Design Pressure=-120 psf.-
Deck:' tvlin..15/327inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elasto.base:(sanded top surface)
:Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide-side laps and 6-inch o.c.at five(5)equally spaced staggered centet.rows.
Underlayment:.Elastoflex.S6 G,applied in full mopping of hot asphalt.
5.6.4.29 All other direct_deck, adhered Polyglass Underlayment systems beneath foam-on tile. systems carry a Maximum
Design Pressure of-45 psf.
5:6.4.30 For mechanically-attached base sheet,the maximum design pressure for the selected.assembly shall meet or exceed
the Zone-1 de
sign;.ptessure determined in accordance with FRSA/TRI April 2012(04-12);_Appendix A,Table 1A or:FBC
1609 Zones _.and 3 shall employ an attachment density designed by a qualified design professiohal to .resist the
elevated.pressure criteria. .Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. :Assemblles
marked:with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data.Sheet.1-29
(January 2016)for Zone;2/3 enharicements.. .
5,7 :Exposure Limitations:
Elastobase;Elastobase P, Polyglass G2 Base or Polyglass APP Base.shall not be left exposed-for kriger.than 30=days
after installation.
Polystick IR=Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS; MTS PLUS,TU.P,TU Plus,TU Max, Dual Pro or Tile Pro shall not be ieft:exposed for longer.:than 180-
days after installation.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1121
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.5259-1125
:Revision 21:.10/17/2016
Page 10 of 13
``,J TRINIT Y j ERD
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180
F days.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed b accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the,substrate(if applicable).
6_3 _Elastobase,Elastobase P or Mule-Hide Nail Baser
6.3.1 Shall. be installed in,compliance with the codified reguir6.ments for ASTM 0226;Type II urgderlayment in.FBC Sections
1507 for the type of prepared roof covering to be.installed.
6.3.2 Non-Tile Applications:
.:Reference is made to the current edition of.the NRCA Steep=slope:,Roofing Manual and ARMA recommendations for
;installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),Dual Pro or Tile Pro,.self-adhered,Elastoflex S6 G or S6 G FR in
hot:asphalt or Polyflex G or G FR,torch applied.
,63.3. -,Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation.Manual.and Table 1-herein,using the instructions noted
above as a guideline.
6.4 Polystick MTS,MTS PLUS,IR-Xe,TU P,TU Plus,TU Max,Dual.Pro,Tile pro:or MU-X or Polyflex SAP,Polyflex SAP FR.
Mule-Hide SA-APP Cap-Sheet or Mule-Hide SA-APP Cap Sheet(FR):
6,4.1 Shall be installed in compliance with the codified requiirenients for AST-M D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
.6.4.2. Direct-to-Deck with Mechanically Fastened Roof Covers:
AIIself-adhering materials,with the exception of Polystick TU.PIus;:Polyflex SAP or:SAP FR and Mule-Hide SA-APP Cap
Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage:edge seam In accordance with Polyglass/Mule-Hide
Back.Nailing Guide. Nails shall be corrosion resistant, 11 gauge.;ri..g.<shank type With a minimum 1 inch diameter
.metal disk or Simplex-type metal cap nail,at a minimum rate of 12"oc Polystick TU Plus should be back-nailed using
-the above noted fasteners and spacing, in area.marked "nail area,area::para:clavar"on the face of membrane. The
head lap membrane is to cover the area being back=nailed
All seal-lap seams (selvage laps) must be
firmly: rolled. with a minimum 28 lb. hand
.roller to ensure full contact and adhesion. °
For Dual Pro and Tile Pro, align the edge:of the-top top sheet:to the.end of the glue pattern
:(the sheet will overlap the fabric).
v1ew.of.O1(ela0.S0m of Dual Pro:an.Tile Pro .
Exterior Research and Design,LLC. Evaluation Report P.12060:02.09-R21
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21:10/17/2016
Page:11 of 13
TRINITY ER®
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as-crickets,exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500-Modified Cement to the area in need of repair, followed by a..minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area, :Patch laps; if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed. to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted-roller or,on steep slopes, use of a stiff broom With approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches.,laps.(min..28:1b roller)or small:areas of the
:roof that are not accessible to a large roller or broom.
...6.43 The Applications(not allowed for Polystick IR-Xe or Polystick MU X):
Reference is.made to FRSA/TRI April.2012(04.42),I.nstallation Manual and Table 1.herein,,us ngthe,nstteyctions noted
above,as a:guideli.ne,
For.mechanically fastened tile roofing over 2-ply system,consisting of base sheet and self-adhering top sheet(s), base
sheet fastening shall be not less than FRSA/TRI April 2012(04.12),Tabled.
Foe adhesive-set tile applications,refer to Section 5.6.4 herein.
For nail-on tile systems over Polystick MTS,battens are required for loading/staging.of the.tile.
:For nail-on tile systems over Polystick MTS PLUS:
Battens are.required for loading staging of lugged the regardless of slope.
➢ :`Battens are required for loading/staging of flat tile at slopes in:excess.of 5:12...:::'
6.4.4 Two(2)Ply Underlayment Systems:
Polystick MTS or:MTS PLUS followed by Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max,Tile Pro, MU-X or Polyflex
.'SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those.associated with
the top-layer material. This is not a requirement,but is allowable if a.2-ply:underlayme_rit System:s desired.
Polystick MTS PLUS followed by Polystick TU P,TU Plus,TU Max, Tile..Pro or Polyflex SAP.is:allowable for use under
foam-on tile:systems. Limits of use are those associated with the top-layer material. This is..not a.requirement,but is
allowable if a 2-ply underlayment system is desired.
6.5 .:Elastoflex S6 G or S6 G FR:
E.lastofl.ex$6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications,reference is made to FRSA/TRI April 2012(04-12)Installation_Manual and Table 1.herein.
6.5..2 Flastoflex S6 G or S6 G FR shall be fully asphalt-applied to the:substrates noted in Section..56. ;Side Laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum.-3 feet from course to course. Side and end
laps.shall be fully in a com lete mo in 'of hot asphalt with asphalt extendin .:a .:roximatel 3 8-inch
y P pp g P P.. g PP y:./
beyond the lap edge.
6_6 Polyflex G or G FR:
6.6A Polyflex 6 or.G FR shall be installed in compliance with current Polyglass published Installation.requirements'. Tor use
' .-..:in the applications,reference is made FRSA/TRI April 2012(04.-12)installation Manual and.T *!.herein. :
6,6,2 Pglyf lex G.or G FR shall be fully torch-;applied to th substrates noted in Section:5:6.. Ii.de. laps shall.be minimum 3-
inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from..course.to course Side and end.laps shall be
: fully:heat-welded.and-inspected to ensure minimum 3/8-in.ch flow.of modified compound.beyond thb.1ap-edge.
6.7 Tile Staging:
b.7.1 Tile shall be loaded and staged in a mannerthat prevents the slippage and/ordamage.to the'underlgy.m6nt. Refer to
Polyglass:p.ublished requirements for the staging.
.Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R21
Cectlficate pfAuthorization#9503 F.BC NON-HVHZ EVALUATION FL5259-R25
Revision 21:10/17/2016
Page 12 of 13
4
�`�J TRINITY I ERD
6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12)must be used
on all-roof.slopes greater than 7:12. Precautions should be taken as needed,.such as the use of battens or nail-
boards,to prevent the sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail=on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6.7.4 For nail-on tile systems over Polystick MTS PLUS: .
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens.are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time.after.installation of self-adhering membranes and before loading of roofing tiles is.forty-eight
.(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Cifficial or Authority Having Jurisdiction in order to properly evaluate:the installation.of this-prod uct.
8. MANUFACTURING PLANTS:
Contact the noted.CtA agency forinformation on product Locations covered for F.A.C.Rule 61G20=3-C(A requirements.
9. QUALITY AssURANCE ENTITY:
UL,LLC—gUA9625;(314)5.7873406;k.chancellor@us.ul.com
END OF EVALUATION REPORT- -
Exterior Research and Design;LLC.. Evaluation Report P12060:02.09-R21
Certificate of Authorization#9503 FBC NON,HVHZ EVALUATION FL5259-925
Revision 21:10/17/2016
Page13 of13