HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Onlin �,UlIC � {'� Fi1eP jPV
77-7
777777
.�
�: i I
L
'-.�:.`.
BCIS Home Lop in 'User Registration i Hot Toplrs Submit Surcharge Star,B Fa Gs i Publications I FBC Stan'. BCIS Site Map Links j Search
db Product Approval
JLIL 1
re @USER:Public User
Product Aor-1 Menu>prod—or Aooli—ion Search>Aoolication List>Applimtbn Detail
3: FL S FL7804-R9
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Entegra Roof Tlle,Inc.
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee,FL 34972
(863)467-0042 Ext 1228
tjohnson@rooftile.com
Authorized Signature Terry Johnson
tjohnson@rooftile.com
Technical Representative Jim Deyarmond
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee,FL 34972
(863)467-0042
J Deyarmon d @ro oftil e.com
Quality Assurance Representative Terry Johnson
Address/Phone/Email 819 South Federal Hwy Suite 300
Stuart,FL 34994
(800)586-7663
tjohnson@rooftile.com
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report-Hardcepy Received
Florida Engineer or Architect Name who developed the Evaluation Robert Nieminen
Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 11/04/2017
Validated By John W.Knezevich,PE
L,j Validation Checklist-Hardcopy Received
Certificate of Independence FL7804 R9 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM C1492 2003
FRSA/TRI April 2012 2012
SSTD 11 1997
TAS 100 1995
TAS 101 1995
TAS 102 1995
TAS 102(A) 1995
TAS 112 1995
e Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/24/2016
Date Approved 06/08/2016
Summary of Products
FL 71 Model,Number or Name Description
7804.1 Entegra Concrete Roof Tiles(HVHZ jurisdictions) Concrete Roof Tile
httns://www.floridabuildinp-.or&-Dr/i)r am) dtl.aspx?param=wGEVXQwtDquovOjOHI%2b... 4/26/2017
Florida Building Code Online 10 Page 2 of 2
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-R9 HVHZ.Ddf
Approved for use outside HVHZ:No Verified By:Robert Nieminen PE-59166
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Refer to ER Section 5 for Limits of Use.Refer to ER Section 6 for FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-Ra HVHZ.pdf
Installation. Created by Independent Third Party:Yes
7804.2 Entegra Concrete Roof Tiles(non-HVHZ Concrete Roof Tile
jurisdictions)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-R9 NON-HVHZ.Odf
Approved for use outside HVHZ:Yes Verified By:Robert Nieminen PE-59166
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Refer to ER Section 5 for Limits of Use.Refer to ER Section 6 for FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-R9 NON-HVHZ.Odf
Installation. Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Flodda is an AA/EEO employer.Co-right 2007-2013 State of Florida,::Priv—Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your,-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by
traditianal mall.It you have any questions,pleas,contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under chapter 455,F.S.must provide Me Department
with an email address if they have one.The emails provided may be used for official communication with the licensee.However small addresses are public record.If you do not wish to supply a personal address,please provide
the Department with an email address which can be made available to the public.To determine It you are a licensee under chapter 455,F.S.,please dick h3ce_.
Product Approval Accept:
_Credit Gard
Safe
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquovOjOHI%2b... 4/26/2017
EXTERIOR RESEARCH&DESIGN, LLC.
` Certificate of Authorization#9503
I 353 CHRISTIAN STREET,UNIT#13
"J TRINITY!ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
[ " Entegra Roof Tile,LLC Evaluation Report E39310.11.11-1-R3
�..NTE A_ 1289 NE 9"Avenue FL7804-1119
R 0 () F T I t_ E Okeechobee,FL 34972 Date of Issuance:11/02/2011
Revision 3:04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
(HVHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
- +'— •,tom
The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M. Nieminen,P.E.
�j fi'•: •„ ,
s: P.E.on 04/18/2016.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 '',1`r�yo,45, �`'" document.Signed,sealed hardcopies have been transmitted to the
s, Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINI-f Y,
ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section Pro a Standard Year
1523.6.5.2 Physical Properties TAS 112 1995
1523.6.5.2 Wind Driven Rain TAS 100 1995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
1523.6.5.2.3 Static Uplift Resistance TAS 102 1995
1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995
3. REFERENCES:
gnifty Examination Reference Date
ERD(TST6049) TAS 101 P39740.02.12 02/21/2012
ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014
ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014
ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015
ATL(TST3782) Physical Properties RT1210.03-15 12/17/2015
ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.05-15 11/07/2015
Miami-Dade(CER1592) HVHZ Compliance 14-0416.12 11/27/2014
Miami-Dade(CER1592) HVHZ Compliance 15-0721.04 11/05/2015
Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.08 02/25/2016
Tile Roof Institute TAS 100,TAS 101,102,102(A) Membership Confirmation Current
PRI(QUA9110) Quality Assurance Inspection Report 11/04/2015
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization#9503 FL7804-R9
Revision 3:04/18/2016
Page 2 of 9
`�J TRINITY i ERD
i
4. PRODUCT DESCRIPTION:
4.1 BERMUDA FLAT,PLANTATION FLAT and HORIZON FLAT are TAS 112,Type 3a(flat-profile)concrete roof tiles.
r 16'
1-lia•
lo•\ /
Y
j= —16, t
T-
2•
10`
r
e ad Fa\
6,/jII
anf
ation Flat
.Rf
13"
Horizon Flat
Exterior Research and Design,I.I.C. Evaluation Report E39330.11.11-1-R3
Certificate of Authorization#9503 FL7804-R9
Revision 3:04/18/2016
Page 3 of 9
TRINITY ERD
i
4.2 BELLA HIGH"S"are TAS 112,Type 1a(interlocking,high-profile)concrete roof tiles.
1�" 13 4
Bella High"S"
4.3 ESTATE"S"and HACIENDA are TAS 112,Type 1b(interlocking,low-profile)concrete roof tiles.
Nail Holes
•
f 6-
Estate"S"
Hacienda
Exterior Research and Design,I.I.C. Evaluation Report E39330.11.11-1-R3
Certificate of Authorization#9503 FL7804-R9
Revision 3:04/18/2016
Page 4 of 9
ry-)
TRINITY;ERD
4.4 GALENA SPANISH"S"and REGAL are TAS 112,Type 2a(non-interlocking, high-profile)concrete roof tiles.
17\
10"'
Galena Spanish"S"
13 1i4"
Regal
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ
requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing
Materials Directory for fire rating of this product.
5.4 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112,Appendix'A'. Such testing shall be submitted to Trinity I ERD for review.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in
HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
Exterior Research and Design,LLC. Evaluation Report E39330.11.11-1-R3
Certificate of Authorization#9503 FL7804-R9
Revision 3:04/18/2016
Page 5 of 9
.�, TRIB�IITY�ERD
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120,as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment-Based System' in
accordance with RAS 127-11 using the data outlined herein.
TABLE I:AERODYNAMIC MULTIPLIERS-a (FT3)
Tile Batten Application Direct-Deck Application
Bermuda Flat 0.189 0.205
Plantation Flat 0.267 0.289
Horizon Flat 0.305 0.330
Bella High"S" 0.349 0.378
Estate"S" 0.267 0.289
Hacienda 0.267 0.289
Galena Spanish"S" N/A 0.235
Regal 0.287 0.311
TABLE 2: RESTORING MOMENT DUE TO GRAVITY-M,(FT-LBF)
Roof Slope(0)
Tile 2:12<0<3:12 3:12<0<4:12 4:12<9<5:12 5:12<0<6:12 6:12<8<7:12 8>7:12
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83
Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04
Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55
Bella High"S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13
Estate"S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14
Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22
Galena Spanish"S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57
Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization#9503 FL7804-119
Revision 3:04/18/2016
Page 6 of 9
. TRINITY'ERD
TABLE3A-1: ATTACHMENT RESISTANCE EXPRESSED ASA MOMENT-MF(FT-LBF)
FLAT PROFILE TILES,MECHANICALLY ATTACHED SYSTEMS
Fastener Direct-Deck Direct-Deck
(min.15/32" (min.19/32"
Tile Type # Size Shank Clip plywood) plywood) Battens
Nail One(1) 10d Smooth or Screw N/A 7.3 9.8 4.9
Nail Two(2) lod Smooth or Screw N/A 14.0 18.8 7.4
Nail One(1) lod Smooth or Screw Eave 19.0 19.0 22.1
Nail One(1) 10d Smooth or Screw Field 24.3 24.3 24.2
Bermuda Flat, Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2
Plantation Flat or Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8
Horizon Nail Two(2) lod Ring N/A 30.9 38.1 17.2
Nail' Two(2)' 10d' Ring' N/A 50.3' 65.5' 48.3'
Screw One(1) #8 N/A N/A 30.8 30.8 18.2
Screw Two(2) #8 N/A N/A 51.7 51.7 24.4
'Installation with a 4-inch tile headlap and fasteners located min.2Y-inch from head of tile.
TABLE 3A=2: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT-LBF)
FLAT PROFILE TILES,ADHESIVE-SET SYSTEMS
Size(inch) Weight(g)
To To
Tile Application Adhesive Substrate To Tile Substrate To Tile Mf(ft-lbf)
TILE BOND- 1 x 6 1 x 6 -11 -11 40.6
Touch'n Seal-StormBond 1.25 x 10 1.25 x 8 `8.3 `10.2 73.2
Inter-
Bermuda Flat, Dependent ICP Adhesives Polyset RTA-1; -5"long -4.5" -9 -5 51.8
Plantation Flat or cross-bond oblong across head
Horizon ICP Adhesives Polyset AH-160 4 x 4 2 x 4 -16 -8 42.8
Independent ICP Adhesives Polyset AH-160 2 x 7 N/A `30 N/A 50.9
2 x 10 N/A -45 N/A 91.9,
TABLE 3B-1: ATTACHMENT RESISTANCE'EXPRESSED ASA MOMENT-MF(FT-LBF)
LOW PROFILE
'TILES,MECHANICALLY ATTACHED SYSTEMS
Fastener Direct-Deck Direct-Deck
(min.15/32" (min.19/32"
Tile Type # Size Shank Clip plywood) plywood) Battens
Nail One
10d Smooth or Screw N/A 8.82 11.8, 4.12
Nail Two(2) 10d Smooth or Screw N/A 16.4 21.9 7.1
Nail One 10d Smooth or Screw Eave 19.0, 19.02 22.12
Nail One 10d Smooth or Screw Field 24.32 24.32 24.22
Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2
Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8
Estate"S"or Hacienda Nail Two(2) 10d Ring N/A 27.8 37.4 28.8
Nail' Two(2)' 10d' Ring' N/A 43.0' 67.5' 50.9'
Screw One #8 N/A N/A 25.82 25.82 22.92
Screw Two(2) #8 N/A N/A 47.1 47.1 49.1
'Installation with a 4-inch tile headlap and fasteners located min.2Y.-inch from head of tile.
2 For one(1)fastener installations,utilize hole that is approximately 4%-inch from the interlocking edge.
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization#9503 FL7804-R9
Revision 3:04/18/2016
Page 7 of 9
-f RINITY ER®
4
TABLE 3B-2: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT-LBF)
LOW PROFILE TILES,MORTAR`$[ADHESIVE-SET SYSTEMS
Size(inch) Weight(g)
To To
Tile Application Adhesive Substrate To Tile Substrate To Tile Mf(ft-Ibf)
TILE BOND'"" 1 x 6 1 x 6 -11 -11 43.8
• Touch'n Seal'"StormBond 1.25 x 10 0.75 x 10 -8.4 -5.1 41.8
Inter-
Dependent ICP Adhesives Polyset RTA-1; "'S"long -4.5 across `6 "5 44.0
cross-bond oblong head
Estate"5"or Hacienda ICP Adhesives Polyset AH-160 4 x 4 2 x 4 `16 `8 1 49.9
ICP Adhesives Polyset AH-160 2 x 7 N/A -30 N/A 36.5
Independent 2 x 10 N/A -54 N/A 60.4
Mortar Per RAS 120 and Product Approval of Mortar Mfgr 20.6
TABLE 3C-1: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT-LBF)
HIGH PROFILE TILES,MECHANICALLY ATTACHED SYSTEMS
Fastener Direct-Deck Direct-Deck
(min.15/32" (min.19/32"
Tile Type # Size Shank Clip plywood) plywood) Battens
Nail One(1) 10d Smooth or Screw N/A 5.1 6.8 2.8
Nail Two(2) 10d Smooth or Screw N/A 6.9 9.2 7.3
Nail One(1) 10d Smooth or Screw Field 23.1 23.1 19.0
Nail One(1) 10d Smooth or Screw Eave 29.3 29.3 24.0
o Nail Two(2) 10d Smooth or Screw Field 27.6 27.6 38.6
Spanish"S"or
Bella High" r Regal Galena Nail Two(2) 10d Smooth or Screw Eave 38.1 38.1 41.8
Nail Two(2) 10d Ring N/A 28.6 41.2 19.4
Nail' Two(2)' 10d' Ring' N/A 33.1' 48.1' 50.9'
Screw One(1) #8 N/A N/A 20.7 20.7 18.1
Screw Two(2) #8 N/A N/A 43.2 43.2 29.8
'Installation with a 4-inch tile headlap and fasteners located min.2%-inch from head of tile.
TABLE 3C-2: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT-LBF)
HIGH PROFILE TILES,MORTAR&ADHESIVE-SET SYSTEMS
Size(inch) Weight(g)
To To
Tile Application Adhesive Substrate To Tile Substrate To Tile Mf(ft-Ibf)
TILE BOND- 1 x 6 1 x 10 -11 ^22 48.1
Inter-
Touch'n Seal-StormBond 1.25 x 10 0.75 x 8 -8.4 -3.9 51.6
•
Dependent ICP Adhesives Polyset RTA-1; two(2)-6" `10"across -12 each -15 36.2
Bella High"S",Galena cross-bond long oblong head
Spanish"S"or Regal I ICP Adhesives Polyset AH-160 4 x 4 I 2 x 4 -16 -8 30.1
ICP Adhesives Polyset AH-160 2 x 7 N/A -30 N/A 48.5
Independent 2 x 10 N/A -63 N/A 93.5
Mortar Per RAS 120 and Product Approval of Mortar Mfgr 24.5
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization#9503 FL7804-R9
Revision 3:04/18/2016
Page 8 of 9
\,ITRINITYI ERD
7. LABELING:
A. 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo,as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein:
and/or
r\E n
� f
E
Labeling:Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S"
and/or
H n on
Labeling:Horizon Flat,Hacienda,Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant Profiles
Okeechobee,FL Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S"
Ft. Myers, FL Horizon Flat, Hacienda
Deerfield Beach, FL Horizon Flat, Hacienda,Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC.—QUA9110;(813)621-5777
-END OF EVALUATION REPORT—
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization#9503 F1.7804-119
Revision 3:04/18/2016
Page 9 of 9