Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Flood Elevation Cert.
• T U.S. DEPARTMENT OF HOMELAND SECURITY , (� OMB No. 1660-0008 Federal Emergency Management Agency 11 "�`� "�Q '"' Expiration Date: November 30,2018 National Flood Insurance Program ipp (� ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for(1)community official,(2)insurance agent/company, and(3)building owner. SECTION A-PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: JOEL&REBECCA PERCY A2. Building Street Address(including Apt., Unit,Suite,and/or Bldg. No.)or P.O. Route and Company NAIC Number: Box No. 11298 MULLER ROAD City State ZIP Code FORT PIERCE Florida 34945 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description,etc.) PARCEL ID 2333-133-0001-000-5 A4. Building Use(e.g., Residential, Non-Residential,Addition,Accessory, etc.) ACCESSORY A5. Latitude/Longitude: Lat.N 27°23'20.825" Long.W -80°26'23.556" Horizontal Datum: ❑ NAD 1927 Z NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 1A A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 0.00 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0.00 sq in d) Engineered flood openings? ❑Yes ❑X No A9. For a building with an attached garage: a) Square footage of attached garage 1230.00 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 6 c) Total net area of flood openings in A9.b 642.00 sq in d) Engineered flood openings? ❑X Yes ❑ No SECTION B-FLOOD INSURANCE RATE MAP(FIRM)INFORMATION B1. NFIP Community Name&Community Number B2. County Name B3. State ST LUCIE COUNTY, UNINCORPORATED 120285 ST. LUCIE Florida B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 12111 C 0164 J 02-16-2012 02-16-2012 AE 18.3 1310. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item 139: ❑ FIS Profile R FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ❑X NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS)area or Otherwise Protected Area(OPA)? ❑Yes Z No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 1 of 6 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30,2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit,Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 11298 MULLER ROAD City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 SECTION C-BUILDING ELEVATION INFORMATION(SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑Building Under Construction* ❑X Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations-Zones Al-A30,AE,AH,A(with BFE),VE,VI-V30,V(with BFE),AR,AR/A,AR/AE,AR/A1-A30,AR/AH,AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: ACE(FCE-4804) Vertical Datum:NAVD 1988 Indicate elevation datum used for the elevations in items a)through h)below. ❑ NGVD 1929 ❑X NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor(including basement,crawlspace,or enclosure floor) 19.3 ❑X feet ❑ meters b) Top of the next higher floor N/A feet ❑ meters c) Bottom of the lowest horizontal structural member(V Zones only) N/A 0 feet ❑meters d) Attached garage(top of slab) N/A N feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 19.2 X feet meters (Describe type of equipment and location in Comments) f) Lowest adjacent(finished)grade next to building(LAG) 17.9 ❑X feet ❑ meters g) Highest adjacent(finished)grade next to building(HAG) 18.3 feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support N/A feet ❑ meters SECTION D-SURVEYOR, ENGINEER,OR ARCHITECT CERTIFICATION This certification i s to be signed and sealed b a land surveyor,engineer, or architect authorized b law to certifyelevation information. I certify that the informationon this Certificate by my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? 0 Yes ❑No ❑Check here if attachments. Certifier's Name License Number CHARLES ARNOLD, PSM FLORIDA LS#4971 .= Title VICE PRESIDENT -~ a Company Name ARNOLD SURVEYING, INC. - Address f� 4888 N KINGS HIGHWAY#425 City State ZIP Code FORT PIERCE Florida 34951 - Signature Date Telephone Ext. 01-19-2020 (772)708-1819 Copy all pages-of this Elev ion Certificate and all attachments for(1)community official,(2)insurance agent/company,and(3)building owner. Comments(including type of equipment and location, per C2(e), if applicable) A5 OBTAINED USING HANDHELD DEVICE; C2E REFERS TO WATER PUMP;A9A DETACHED GARAGE;A9C SMART VENT RATED AT 1284 SQUARE INCHES; PGS 1,2,5&6 COMPLETED BY SURVEYOR; PGS 3,4&6 LEFT BLANK INTENTIONALLY&IS NOT CERTIFIED BY SURVEYOR FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 2 of 6 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30, 2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 1129&MULLER ROAD City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 SECTION E—BUILDING ELEVATION INFORMATION(SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A(WITHOUT BFE) For Zones AO and A(without BFE), complete Items El—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade(HAG)and the lowest adjacent grade(LAG). a) Top of bottom floor(including basement, crawlspace, or enclosure)is ❑feet ❑meters ❑above or ❑below the HAG. b) Top of bottom floor(including basement, crawlspace,or enclosure)is ❑feet ❑meters ❑above or ❑below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 1-2 of Instructions), the next higher floor(elevation C2.b in the diagrams)of the building is ❑feet ❑meters ❑above or ❑below the HAG. E3. Attached garage(top of slab)is ❑feet ❑meters ❑above or ❑below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑feet ❑meters ❑above or ❑below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F—PROPERTY OWNER(OR OWNER'S REPRESENTATIVE)CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A(without a FEMA-issued or community-issued BFE)or Zone AO must sign here.The statements in Sections A, B,and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑Check here if attachments. FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 3 of 6 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30,2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit, Suite,and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 11298 MULLER ROAD City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 SECTION G—COMMUNITY INFORMATION(OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C(or E), and G of this Elevation Certificate. Complete the applicable item(s)and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only,enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE) or Zone AO. G3. ❑ The following information(Items G4—GI0)is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as-built lowest floor(including basement) of the building: ❑feet ❑ meters Datum G9. BFE or(in Zone AO)depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments(including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 4 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 11298 MULLER ROAD City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View"and'Rear View'; and, if required,'Right Side View"and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. �5 = Photo One Photo One Caption FRONT VIEW-PHOTO TAKEN JANUARY 18 2020 Clear Photo One.: - 3 x'a - K r\b��kt� r'i'., 9 4,7-1 , , aq fi l a. Photo Two Photo Two Caption RIGHT VIEW-PHOTO TAKEN JANUARY 18 2020 Clear Photo;Two FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 5 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit,Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number: 11298 MULLER ROAD City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View'; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. r Photo Three Photo Three Caption REAR VIEW-PHOTO TAKEN JANUARY 18 2020 !Clear Photo Three ol Photo Four Photo Four Caption LEFT VIEW-PHOTO TAKEN JANUARY 18 2020 f Clear Photo Four FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 6 of 6 L SEVALUATION Icc Most Widely Accepted and Trusted in top�emtim Aim Innovaition 1CC-ESIvaluation Report Reissued 02/2019 DIVISION: 08 00 00—OPENINGS SECTION: 08 9S 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT° AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 ICC ICC ICC PMG LISTED \V �IRV "2014 Recipient of Prestigious Western States Seismic Policy Council ��� �WSSPC Award in Excellence" CODECOUNCIWERNATIONAI. � A Subsidiary of CADECOUNCIL' ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to an product covered b the report. ISOAEC 17065 P Y P Y P Product CotlilimgU Body K,000 Copyright°2019 ICC Evaluation Service, LLC. All rights reserved. ESS IC Most Widely,Accepted and Trusted' IMES Evaluation Report ESR-2074 Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Each unit is fabricated from stainless steel. Smart Vent® Section: 08 95 43—Vents/Foundation Flood Vents Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The REPORT HOLDER: S -martVENT®Stacking Model #1540 511 and FloodVENT® Stacking Model #1540-521 units each contain two SMART VENT PRODUCTS,INC. vertically arranged openings per unit. EVALUATION SUBJECT: 3.2 Engineered Opening: The FVs comply with the design principle noted in Section SMART VENT AUTOMATIC FOUNDATION FLOOD 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section VENTS:MODELS#1540-520;#1540-521;#1540.510;#1540- 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and 511;#1540.570;#1540-574;#1540-524;#1540-514 IRC)] for a maximum rate of rise and fall of 5.0 feet per FLOOD VENT SEALING KIT#1540-526 hour(0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs 1.0 EVALUATION SCOPE must be installed in accordance with Section 4.0. Compliance with the following codes: 3.3 Ventilation: ■ 2018, 2015, 2012, 2009 and 2006 International Building The SmartVENT® Model #1540-510 and SmartVENT® Code ®(IBC) Overhead Door Model#1540-514 both have screen covers � with /4-inch-by-�/4-inch (6.35 by 6.35 mm) openings, ■ 2018, 2015, 2012, 2009 and 2006 International yielding 51 square inches (32 903 mmz)of net free area to Residential Code®(IRC) supply natural ventilation. The SmartVENT® Stacking ■ 2018 International Energy Conservation Code®(IECC) Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches ■ 2013 Abu Dhabi International Building Code(ADIBC)t (65 806 mmz) of net free area to supply natural ventilation. 'The ADIBC is based on the 2009 IBC.2009 IBC code sections referenced Other FVs recognized In this report do not offer natural in this report are the same sections in the ADIBC. ventilation. Properties evaluated: 3.4 Flood Vent Sealing Kit: ■ Physical operation The Flood Vent Sealing Kit Model#1540-526 is used with ■ Water flow SmartVENT® Model #1540-520. It is a Homasote 440 Sound Barrier (ESR-1374) insert with 21 — 2-inch-by-2- 2.0 USES inch (51 mm x 51 mm)squares cut in it.See Figure 4. The Smart Vent® units are engineered mechanically 4.0 DESIGN AND INSTALLATION operated flood vents (FVs) employed to equalize 4.1 SmartVENT0 and FloodVENr: hydrostatic pressure on walls of enclosures subject to SmartVENT® and FloodVENT® are designed to be rising or falling flood waters. Certain models also allow natural ventilation. installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the 3.0 DESCRIPTION vents must be in accordance with the manufacturer's 3.1 General: instructions, the applicable code and this report. Installation clips allow mounting in masonry and concrete When subjected to rising water, the Smart Vent® FVs walls of any thickness. In order to comply with the internal floats are activated,then pivot open to allow flow in engineered opening design principle noted in Section either direction to equalize water level and hydrostatic 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of pressure from one side of the foundation to the other. The ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the FV pivoting door is normally held in the closed position by Smart Vent®FVs must be installed as follows: a buoyant release device. When subjected to rising water, N With a minimum of two openings on different sides of the buoyant release device causes the unit to unlatch, each enclosed area. allowing the door to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. ■ With a minimum of one FV for every 200 square ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are thev to be construed 1e" as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as j��� to any finding or other matter in this report,or as to any product covered by the report. w w"K cvo[wict .<s Copyright©2019 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 5 ESR-2074 I-Most W.Vely Accepted and Trusted Page 2 of 5 feet (18.6 M ) of enclosed area, except that the 5.2 The Smart Vent® FVs must not be used in the place SmartVENT® Stacking Model #1540-511 and of"breakaway walls" in coastal high hazard areas, but FloodVENT® Stacking Model #1540-521 must be are permitted for use in conjunction with breakaway installed with a minimum of one FV for every walls in other areas. 400 square feet(37.2 M2)of enclosed area. 6.0 EVIDENCE SUBMITTED ■ Below the base flood elevation. 6.1 Data in accordance with the ICC-ES Acceptance ■ With the bottom of the FV located a maximum of Criteria for Mechanically Operated Flood Vents 12 inches (305.4 mm) above the higher of the final (AC364), dated August 2015 (editorially revised grade or floor and finished exterior grade immediately October 2017). under each opening. 6.2 Test report on air infiltration in accordance with ASTM 4.2 Flood Vent Sealing Kit E283. The Flood Vent Sealing Kit Model 1540-526 is used in 7.0 IDENTIFICATION conjunction with FloodVENT® Model #1540-520. When 7.1 The Smart VENT®models and the Flood Vent Sealing installed and tested in accordance with ASTM E283, the Kit recognized in this report must be identified by a FV and Flood Vent Sealing Kit assembly have an air label bearing the manufacturer's name (Smartvent leakage rate of less than 0.2 cubic feet per minute per lineal foot (18.56 I/min per lineal meter) at a pressure Products, Inc.), the model number, and the evaluation differential of 1 pound per square foot (50 Pa) based on report number(ESR-2074). 12.58 lineal feet (3.8 lineal meters) contained by the Flood 7.2 The report holder's contact information is the Vent Sealing Kit. following: 5.0 CONDITIONS OF USE SMART VENT PRODUCTS, INC. The Smart Vent® FVs described in this report comply with 430 ANDBRO DRIVE, UNIT 1, PITMAN, NEW JERSEY 08071 or are suitable alternatives to what is specified in, those (877)441-8368 codes listed in Section 1.0 of this report, subject to the www.smartvent.com following conditions: info()smartvent.com 5.1 The Smart Vent®FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict,the instructions in this report govern. TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE(in.) COVERAGE(sq.ft.) FloodVEN 1540-520 15 /a"X 7 /4" 200 SmartVENT® 1540-510 153/4"X 73/4" 200 FloodVENT®Overhead Door 1540-524 153/4"X 73/4" 200 SmartVENT®Overhead Door 1540-514 153/4"X 73/4" 200 Wood Wall FloodVENT® 1540-570 14"X 83/e 200 Wood Wall FloodVENT®Overhead Door 1540-574 14"X 83/4' 200 SmartVENT®Stacker 1540-511 16"X 16" 400 FloodVent®Stacker 1540-521 16"X 16" 400 For SI: 1 inch=25.4 mm;1 square foot=m2 fir KLI ----------------- 77 �. r. 5d s X FIGURE 1—SMART VENT:MODEL 1540-510 ESR-2074 Most Widely Accepted and Trusted • Page 3 of 5 h I I "h i FIGURE 2 SMART VENT MODEL 1540-520 i f .r FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN i INTERIOR EXTERIOR FIGURE 4—FLOOD VENT SEALING KIT ESIC C Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2074 CBC and CRC Supplement Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT'AUTOMATIC FOUNDATION FLOOD VENTS:MODELS#1540-520;#1540-521;#1540-510;#1540-511;#1540- 570;#1540.574;#1540-524;#1540514 FLOOD VENT SEALING KIT#1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents, recognized in ICC-ES master evaluation report ESR-2074, have also been evaluated for compliance with codes noted below. Applicable code edition: ■ 2016 California Building Code(CBC) ■ 2016 California Residential Code(CRC) 2.0 CONCLUSIONS 2.1 CBC: The Smart Vent®Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with 2016 CBC Chapter 12, provided the design and installation are in accordance with the 2015 International Building Code® (IBC) provisions noted in the master report and the additional requirements of CBC Chapters 12, 16 and 16A, as applicable. The products recognized in this supplement have not been evaluated under CBC Chapter 7A for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. 2.2 CRC: The Smart Vent®Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comp with the 2016 CRC, provided the design and installation are in accordance with the 2015 International Residential Code (IRC)provisions noted in the master report. The products recognized in this supplement have not been evaluated under 2016 CRC Chapter R337, for use in the exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban Interface Fire Area. The products recognized in this supplement have not been evaluated for compliance with the International Wildland—Urban Interface Code®. This supplement expires concurrently with the master report, reissued February 2019. I ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. wi[n nsu mawwcc .,,, Copyright©2019 ICC Evaluation Service,LLC. All rights reserved. Page 4 of 5 i MIce SERVICE— Most Widely Accepted . , IMES Evaluation Report ESR-2074 FBC Supplement Reissued February 2019 This report is subject to renewal February 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT'AUTOMATIC FOUNDATION FLOOD VENTS:MODELS#1540-520;#1540-521;#1540-510;#1540-511; #1540Z70;#1540Z74;#1540-524;#1540514 FLOOD VENT SEALING KIT#1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vene Automatic Foundation Flood Vents, recognized in ICC-ES master report ESR-2074, have also been evaluated for compliance with the codes noted below. Applicable code editions: IN 2017 Florida Building Code—Building ■ 2017 Florida Building Code—Residential 2.0 CONCLUSIONS The Smart Vent®Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with the Florida Building Code—Building and the FRC, provided the design and installation are in accordance with the 2015 International Building Code®provisions noted in the master report. Use of the Smart Vent®Automatic Foundation Flood Vents has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building Code—Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued February 2019. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are lhev 10 be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied as t to any finding or other matter in this report,or as to any product covered by the report. - Copyright©2019[CC Evaluation Service,LLC. All rights reserved. Page 5 of 5 DETAIL DIAGRAM MODEL 1540-510 DUAL FUNCTION FLOOD AND VENTILATION VENT 1'-4 1/4" R/O ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ CLIP SLOTS USE TWO TOP ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ AND TWO BOTTOM ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ BEHIND THE RODENT SCREEN, LOUVERS ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑�❑❑❑❑❑❑❑❑❑❑❑ AUTOMATICALLY OPEN AND CLOSE WITH ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ TEMPERATURE. NO ELECTRICITY IS NEEDED R/O ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ 000000000000000000000000000000000000000 000❑❑000000000000❑❑00000000000000000000❑0 ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ 000000000000000000000000000000000000000 00000000000000000000000000000000000000❑ ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ 000000000000000000000000000000000000000 ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ a FLOAT SLOTS FIGURE 1 FRONT VIEW HURRIBOND GRIP & SEAL ADHESIVE LOCATION (FLANGE) • ° 0 • 12" MAX FROM p FIGURE 3 FINAL GRADE ------CLIPS INSTALLED: TWO ON SIDE VIEW VENT TOP TWO ON BOTTOM DOOR d L VENT SMART VENT Foundation Flood Vents FRAME 430 AndBro Dr., Unit 1 Pitman NJ 08071 FIGURE 2 SMART VENT® DUAL FUNCTION FLOOD SIDE VIEW 877-441 -8368 AND VENTILATION VENT WWW.SMARTVENT.COM MODEL 1540-510 Dwc NO. 1 5 40—5 1 0 EV A R A A DATE. 6-21-16 SHEEr 1 OF 2 S m c rt VENT INSTALLATION INSTRUCTIONS do DETAILS MODEL 1540-510 8 7 7 4 4 1 8368 DUAL FUNCTION FLOOD AND VENTILATION VENT REV. 6-21-16 Nww . Smcrtvent. com INSTALLATION INSTRUCTIONS 1. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE OUT) 2. PREPARE A CLEAN 16.25" WIDE BY 8.25' HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE THAN 12" ABOVE THE FINISHED GRADE. 3. APPLY A BEAD OF HURRIBOND GRIP do SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE, VENT FRAME. (FIG. 2) 4. INSERT INSTALLATION CLIPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME. 5. THE SPRING ARM OF THE CUPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME. COMPRESS THE BOTTOM TWO CLIPS AND BEGIN SLIPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CLIPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS. 6. WITH THE FRAME NOW IN THE OPENING, AND THE BOTTOM SPRINGS IN PLACE, COMPRESS THE TOP SPRINGS AND PUSH THE VENT FRAME INTO THE OPENING COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL 7. RE—CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK. 8. INSTALL THE DOOR INTO FRAME BY GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND ROTATE UNTIL IT IS LATCHED. 9. TO OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING. DETAILED SPECIFICATIONS: MATERIAL: STAINLESS STEEL OPERATION FLOOD: AUTOMATIC NON—POWERED ACTIVATION AND OPERATION VENT REMAINS CLOSED AND LOCKED UNTIL ACTIVATED OPERATION AIR: AUTOMATIC LOUVERS FULLY OPEN AT 75 DEG. FULLY CLOSED AT 35 DEG. NO POWER REQUIRED INSTALLATION: SECURED W/ 4 STAINLESS STEEL INSTALLATION CLIPS INCLUDED AND AN ADHESIVE HYDROSTATIC RELIEF: 200 SQ. FT PER VENT VENTILATION: 51 SQ. IN. PER VENT NOTE. VAPOR BARRIER ALLOWS FOR REDUCED VENTILATION REQUIREMENTS FLOOD: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS a COLORS: STAINLESS (STANDARD) EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE) MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY: FEMA, NFIP, ICC, do ASCE SUPPORTIVE DOCUMENTS, TB 1-08. 44CFR 60.3(C)(5), ASCE 24-14 ICC EVALUATION # ESR-2074 SHEET 2 OF 2 PLANNING & DEVELOPMENT BOARD OF ' SERVICES DEPARTMENT COUNTY COUNTII COMMISSIONERS . Building and Code Regulation - --- Division Elevation Affidavit Date Property Address wn% M\,-x\9t Permit # \CkX?_-<RQ�,D Flood Zone The non-habitable / non-residential building (accessory structure) cannot be converted to a habitable dwelling unit unless it is modified with a building permit to comply with the relevant elevation requirement. b a t Print Owner's Name Signature f Ow er STATE OF FLORIDA COUNTY OF ST 1_u-c-1 6- The foregoing instrument was acknowledged before me this /54" day of � ,20_' by 0e r=c z, personally known tome or who has produced n)a4 as identification. Signature of Notary Public ff Commission Number IVII'COMMISSION#GG009206 EXPIRES:October 4,2020 '%�P,;,Y4:`'•t3onded7hruNoteryPW*Unw milers Website:www.stiucieco.gov 2300 Virginia Avenue-Fort Pierce,FL. 34982-5652 Phone(772)462-1553 FAX(772)462-1578