Loading...
HomeMy WebLinkAboutFllod Elevation Cert - finalU.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agenticompany, and (3) building owner. SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: Victor M Quintero A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 8509 Cobblestone DR City State ZIP Code FORT PIERCE Florida 34945 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) 2326-600-0090-000-6 LOT 85 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 27°2434.2' N. Long.80°24'35.4" W. Horizontal Datum: ❑ NAD 1927 X NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 1A A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑ Yes ❑x No Ag. For a building with an attached garage: a) Square footage of attached garage 400.00 sq It b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood openings? ❑ Yes 0 No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State St. Lucie County 120285 Saint Lucie Florida B4. Map/Panel B5. Suffix 86. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 12111 C01 70 J 02-16-2012 02-16-2012 AE 16.5 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 89: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: Bit. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: 812. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Pagel of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8509 Cobblestone DR City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction" ❑x Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, VI—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: AF6653 Vertical Datum: NAVD 88 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 17.32 ❑x feet ❑ meters b) Top of the next higher floor N/A ❑ feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet ❑ meters d) Attached garage (top of slab) 16.75 ❑x feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building feet 87 16.❑ ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 16.53 ❑x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 16.93 ❑x feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including ❑ feet meters N/A ❑ structural support SECTION D—SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. 1 certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number Thomas P. Kiernan 6199 Title Professional Surveyor Jeli Company NameCulpepper & Terpening. Inc. Address 2980 South 25th Street City State ZIP Code Fort Pierce Florida 34981 Signatur Date Telephone Ext. 04-19-2018 (772)464-3537 206 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) C2. e) AC Pad is Lowest equipment servicing building FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8509 Cobblestone DR City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. Ell. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8509 Cobblestone DR City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) E]feet ❑ meters of the building: Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8509 Cobblestone DR City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section AS. If submitting more photographs than will fit on this page, use the Continuation Page. iAIY ■ Photo One Photo One Caption Front l l/08/17 Clear Photo One ` r t F F it7� Photo Two Photo Two Caption Back l l/08/17 Clear Photo Two FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Page Expiration Date: November30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 8509 Cobblestone DR City State ZIP Code Company NAIC Number FORT PIERCE Florida 34945 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and 'Rear View"; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the Flood openings or vents, as indicated in Section AS. m' Photo Three Photo Three Caption Right Side 11/08/17 Clear Photo Three Photo Four Photo Four Caption Left Side 11/08/17 Clear Photo Four FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 SET`/C LB Curve Table Curve # Length Radius Delta C1 6.71 205.00 001 052'30" C2 5.89 180.00 001 052'30" C3 1.64 50.00 001 "52'30" LOT 84 CREEKSIDE PLAT NO.1 P.B. 55 PG. 12 OCCUPIED .......%-- FLOOD ZONE "X" FLOOD ZONE "AE-16.5" .. WA TER 'SERACE- - -- -- -. SET 5/g" IR/C LEI 4288 WATER SERVICE i - _ R/W 7 ` ryC• CURB :� TO p `_ (YELLOWSTONE CIRCLE \' 375.00'� 2 08 25" THOMAS P. KIERNAN', " Professional Surveyor & Mapper Florida Certificate No. 6199 �72'I2� '__S62'19'15"E 25.00' Ci W.M.T.-2 3 R=220.00' A=14'56'09" L=57.35' COVERED LOT 85 1 STORY CBS RESIDENCE MODEL 4EBB/D ELEV.=18.79 (N.G.V.D.) ELEV.=17.32 (N.A.V.D.) LFL001 CONCRETE DRIVEWAY E_ "X" 3" SAN CO LOT 86 CREEKSIDE PLAT NO.1 P.B. 55 PG. 12 il VACANT SET 4266 - STREET LIGHT SANITARY SERVIC C2 W —SET 5/8" IRO LB 4283� NI TO P.T �� R=375.00' 1 (t-2p5 000" ASPHALT R/W A=14'56'09" BENCHMARK C1 A� 2438 PAVING TOP SAN. MH SS-8 10� L=97.75ELEV.-16.79 — 3$ --- — fRkIVE �P.C.C.COBBLESTONE A=14'56-U' L=91.24' CERTIFIED T0: 1. Victor Manuel Quintero and Ivalisse Quintero DATE 2. D.R. Horton, Inc._ 3. CHI Mortgage Company, Ltd. 4. Allfant National Title Insurance Co. J LEA- DESCRIPTION BEING ALL OF LOT 85, ACCORDING TO CREEKSIDE PLAT NO. 1,AS RECORDED IN PLAT BOOK 55, PAGE 12 PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINS 0.233 ACRE, MORE OR LESS. GRAPHIC SCALE 20 0 10 20 PROPERTY ADDRESS 8509 COBBLESTONE DRIVE, FORT PIERCE ( IN FEET ) LEGEND & ABBREVIATIONS 1 md, 20 to BM DENOTES BENCHMARK O.R. DENOTES OFFICIAL RECORDS BOOK BB DENOTES BEARING BASE P.B. DENOTES PLAT BOOK C.M. DENOTES CONCRETE MONUMENT PG. DENOTES PAGE CONC DENOTES CONCRETE P.U.E. DENOTES PRIVATE UTILITY EASEMENT C.B. DENOTES CATCH BASIN P.D.E. DENOTES PRIVATE DRAINAGE EASEMENT CBS DENOTES CONCRETE BLOCK STRUCTURE P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER CD DENOTES CHORD DISTANCE P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR CB DENOTES CHORD BEARING P.C.C. DENOTES POINT OF COMPOUND CURVATURE C/O DENOTES CLEAN OUTS P.D. DENOTES POINT OF CURVATURE q DENOTES D.E. DENOTES LIRA NAGS EASEMENT P.E. DENOTES POINT OF TANGENCY (P) DENOTES PLAT DATA F.F.E. DENOTES FINISH FLOOR ELEVATION P.C.P. DENOTES PERMANENT CONTROL POINT FIND DENOTES FOUND R DENOTES RADIUS I.Q. DENOTES IRRIGATION QUALITY WATER R/W DENOTES RIGHT OF WAY IR/C DENOTES IRON ROD AND CAP SAN. DENOTES SANITARY LB. DENOTES LICENSED BUSINESS U.E. DENOTES UTILITY EASEMENT L DENOTES ARC LENGTH W.M.T. DENOTES WATER MANAGEMENT TRACT L.M.E. DENOTES LAKE MANAGEMENT EASEMENT MAG/D DENOTES SET MAG NAIL AND DISK (M) DENOTES MEASURED DATA WMME DENOTES WATER MAINTENANCE MANAGEMENT E M.H. DENOTES MANHOLE A DENOTES INCLUDED ANGLE N/D DENOTES NAIL AND DISK (NR) DENOTES NON RADIAL LINE DENOTES DRAINAGE FLOW O.S.T. DENOTES OPEN SPACE TRACT ,g� N.G.V.D. DENOTES NATIONAL GEODETIC VERTICAL DATUM DENOTES PROPOSED ELEVATION N.A.V.D. DENOTES NORTH AMERICA VERTICAL DATUM GENERAL NOTES 1. The last date of field work was 11-08-17 2. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 3. Reproductions of this map are not valid without the signature and original raised seal of a Florida Licensed Surveyor and Mapper. 4. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This Information should be obtained through appropriate title verification. 5. All above ground fixed improvements, if any, have been located and shown hereon. 6. Underground foundations and improvements were not located as part of this survey. 7. Flood Note: By graphic plotting only, this property Is in Zone X and AE 16.5, according to the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February 16, 2012. The exact designation can only be determined by an elevation certificate. No additional search of the public records has been preformed. There may be additional map Amendments affecting this property.. 8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and the use of existing field elevation data. 9. The bearings shown hereon are based on Plat information and are referenced to the common line between lot 85 and 86 which bears South 79'07'54" East and all bearings are relative thereto. 10. Elevations shown hereon are based on the North America Vertical Datum (N.A.V.D.) 1929. 11. The building setbacks shown hereon, although based on the best available information, are not certified to and must be verified prior to design or construction. Final As -Built Survey Lot 85 For: D. R. HORTON File:15-141.100.085 Date: 11-09-2017 FB: N/A SCALE 1"=20' DRAWN BY: PV FEMA LINE & VERTICAL DATUM ND 08-25-2017 CULPEPPER & TERPENING, INC CONSULTING ENGINEERS I LAND SURVEYORS 2980 SOUTH 25th STREET FORT PIERCE, FLORIDA 34981 PHONE 772-464-3537 FAX 772-464-9497 v .ct-eng.com STATB OF FLORIDA CERTIFICATION No. LB 4286