Loading...
HomeMy WebLinkAboutOwens Corning Shingle Product Approval " • Professional Regulation BCIS Home I Login I User Registration ; Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map ' Links Search bProduct Approval USER:Public User Pro ct Approval Menu>Product or Application Search>Application List>Application Detail • FL# FL10674-1116 Application Type Revision Code Version 2020 Application Status Pending FBC Approval Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R16 COI 2020 01 COI NIEMINEN pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2019 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/11/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Summary of Products FL* Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R16 II 2020 12 11 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R16.pd Impact Resistant: N/A Verified By: Robert 3,M. Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT SHIN LES FL10674-R16,pdf Created by Independent Third Party:Yes Contact us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Co *ght 2007-2013 State of Florida.::R[[ya Qy Statement::Accessibility Statement::Refund S,atement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The annals provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: U *_W E Credit Card safe ®� it OWENS CORNING SCIENCE&TECHNOLOGY, LLC 2790 COLUMBUS ROAD,ROUTE 16 GRANVILLE,OHIO43023,1200 • January 26, 2021 REF: Pending FBC Approvals It has come to our attention that there are building departments that aren't accepting the 2020 FBC Product Approvals for some of our products due to the lack of formal FBC approval.A list of products and Product Approvals for which the status is listed as"Pending FBC Approval"under the 2020 FBC is below: FL10674-R16 Asphalt Shingles FL9777-R14 WeatherLock®Underlayments FL16828-R4 VentSure°Ventilation Products FL19979-R2 DeckSeal°Modified Bitumen Roofing (Non-HVHZ) FL19982-R2 DeckSeal°Modified Bitumen Roofing (HVHZ) FL11602-R11 Titanium Roof Underlayments FL15216-R8 RhinoRoof,ABC Pro Guard 20,and SRS TopShieid TS20 Synthetic Roof Underlayments FL32344-R1 RhinoRoof Granulated Self-Adhering Underlayment Use of the Florida Product Approval System is voluntary per the Florida Statutes. Please see the verbiage from the Statutes below.Applicable sections are highlighted. 553.8425 Local product approval. (1) For local product approval, products or systems of construction shall demonstrate compliance with the structural windload requirements of the Florida Building Code through one of the following methods: (a) A certification mark, listing, or label from a commission-approved certification agency indicating that the product complies with the code; (b) A test report from a commission-approved testing laboratory indicating that the product tested complies with the code; (c) A product-evaluation report based upon testing, comparative or rational analysis, or a combination thereof, from a commission-approved product evaluation entity which indicates that the product evaluated complies with the code; (d) A product-evaluation report or certification based upon testing or comparative or rational analysis, or a combination thereof, developed and signed and seated by a Florida professional engineer or Florida registered architect, which indicates that the product complies with the code; (e) A statewide product approval issued by the Florida Building Commission; or (f) Designation of compliance with a prescriptive, material standard adopted by the commission by rule under s. 553.842(15). (2) For product-evaluation reports that indicate compliance with the code based upon a test report from an approved testing laboratory and rational or comparative analysis by a Florida registered architect or Florida professional engineer, the testing laboratory or the evaluating architect or engineer must certify independence from the product manufacturer. (3) Local building officials may accept modifications to approved products or their installations if sufficient evidence is submitted to the local building official to demonstrate compliance with the code or the intent of the code, including such evidence as certifications from a Florida registered architect or Florida professional engineer. (4) Products demonstrating compliance shall be manufactured under a quality assurance program audited by an approved quality assurance entity. (5) Products bearing a certification mark, label, or listing by an approved certification agency require no further documentation to establish compliance with the code. (6) Upon review of the compliance documentation, and a finding that the product complies with the code, the authority having jurisdiction or a local building official shall deem the product approved for use in accordance with its approval and limitation of use. (7) Approval shall be valid until such time as the product changes and decreases in performance; the standards of the code change, requiring increased performance; or the approval is otherwise suspended or revoked. Changes to the code do not void the approval of products previously installed in existing buildings if such products met building code requirements at the time the product was installed. Per the above verbiage, our signed and sealed Evaluation Reports are acceptable, even in the absence of a Florida Product Approval. In fact, our products actually comply with Section 553.8425 (1) (a)and (1) (d)above as all of our products bear a Certification Agency mark. We would ask that based on the above information, permits using the affected Product Approval numbers be approved. If you have any questions about the applicable Florida Statute, please contact Mo Madani with the Florida Building Commission at(850)717-1825. Regards, Greg Keeler Technical Services Leader Owens Corning Science &Technology, LLC 740.321.6345 greg.keelerCa)owenscorning.com OWENS CORNING NEMO I etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 to Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION Owens Corning Evaluation Report 037940.02.12-1111 One Owens Corning Parkway F1.10674-1116 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 11: 12/11/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition(2020)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: r�- - - - rr The facsimile seal appearing was authorized by Robert Robert J.M.Nieminen,P.E. ..c4 �,,. ''•,,�5`.J s. Nieminen,P.E.on 12f 11/2020.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 ✓�:.,. '=i'"'' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. @2018 NEMO ETC,LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: SCOPE:1. Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. .••. Section Property Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2019 Entity Examination Reference gate Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals&Wind Resistance file R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 PRI(QUA9110) Quality Control Service Confirmation 04/05/2020 PRI(QUA9110) Quality Control Florida$CIS Current 4. •••DDESCRIPTION: TABLE 1:ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Description Standard Starter Strip Shingle H-TX,OR Accessory Starter Strip Plus MN,OR ASTM D3462 starter strips for asphalt roof shingles Starter SRS TopShield Starter MN,OR Strips mineral-surfaced,fiberglass-reinforced, Starter Shingle Roll NH ASTM D1970 self-adhering 5BS modified bitumen starter Supreme` GA,CA,CO,I-TX,NJ,OH, ASTM D3462 fiberglass reinforced 3-tab asphalt TN,OR,IL roof shingles fiberglass reinforced,4-tab asphalt Berkshire® MN ASTM D3462 roof shingles Duration Premium CA,OR Asphalt Duration®Premium COOL CA TruDefinition®Duration' Shingles 1N,CA,CO,I-TX,FL,NJ,OH, TruDefinition®Duration MN,OR,GA,IL,TN fiberglass reinforced,laminated Designer Color Collection ASTM D3462 • GA,IN,CA,CO,H-TX,I-TX, asphalt roof shingles Oakridge FL,NJ OH,TN TruDefinition®Oakridge® H-TX,I-TX WeatherGuard®HP TN NEMO ETC,LLC Evaluation Report 037940.02.12-1111 Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 2 of 10 ONEMOletc. TABLE 1:ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Description Standard Berkshire Hip and Ridge MN Shingles with Sealant Hip and DuraRidge®Hip and Ridge MN fiberglass reinforced,hip and ridge Ridge Shingles with Sealant ASTM D3462 asphalt roof shingles Shingles Prolidge GA,CA,OH,OR WeatherGuard®HP Hip and TN Ridge Shingles 5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5_5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Supreme Berkshire® Duration®Premium Duration'Premium COOL TruDefinition®Duration® ASTM D3161(F)&ASTM D7158(H) TruDefinition®Duration®Designer Color Collection Oakridge' TruDefinition®Oakridge WeatherGuard®HP 5.5.1 Classification by ASTM D7158: ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC,LLC Evaluation Report 037940.02.12-1131 Certificate ofAuthori2otion#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 3 of 10 ONEMOletc. TABLE 213:WIND CLASSIFICATIONS,STARTER STRIPS AND HIP&RIDGE Type Product F8C Table 1507.2.7.1 or R905.2.6.1 Starter Strip Shingle Starter Strips Starter Strip Plus ASTM D3161,Class F SRS TopShield Starter Berkshire'Hip and Ridge Shingles with Sealant Hip&Ridge DuraRidge®Hip and Ridge Shingles with Sealant ASTM D3161,Class F Shingles ProEdge® WeatherGuard®HP Hip and Ridge Shingles 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 614320-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. INSTALLATION:6.6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off)or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions,using minimum five(5)nails per strip. Felt underlayment —Deck Felt underlayment Oadc SCS-244red a Waakherl.0" Self-adhered underlayment WeatherLocke C underlayment Drip Drip edge p edge edge e Nab located Na1s ixatad 2'-r from eave Install fast Self-sealing adhesive po itimed adhesive Starter Strip positioned along eave fru shingle withi.v rst Starter Strip Pluz positioned abng eave Mi.ti removed - temtWed r Starter Strip PWs overha s eaves and rakes 174"-314' Starter Strip shingle overhangs eaves and rakes A=1'," � Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus NEMO ETC,LLC Evaluation Report 037940.02.12-R11 Certificate of Authorization#32455 7t"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 4 of 10 fONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck Drip edge Underlayment Drip edge Starter Shingle Roll adhered directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3:Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Berkshire®shingles require minimum five(5)nails per shingle. ➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Normal Mansard or Area pare Normal Mansard or Wind Areas High Wind desvanes y Wind Areas Area pare Area pare vientos normafes Areas vientos foartes High Wind dasvanes Area pare vientos norrneles Areas vientos fuartas _ 11 1. 12 r 5"Ezposure 5 WS'Exposure Exposicidn Po Exposicfdn Figure 4:Minimum Nailing,Supreme Figure 5:Minimum Nailing,Supreme (Standard Size) (Metric Size) NEMO ETC,LLC Evaluation Report 037940.02.12-1111 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 5 of 10 ONEMO etc. 6.3.1.2 Berkshire®: &abrd strip Sealant strip La Ilia de sellador La rua de settador 7R Y2" ih" r r r Figure 6: 5-Nail Pattern,Berkshire Figure 7: 6-Nall Pattern,Berkshire Sealant strip La tirade sellador 0t----------i1.4---------)• • • • Q 8 t/t' S Yt' R Yz° �.. r 1 2 Asphalt tooling cement Cermioto de Who da astaho Figure S. Mansard or Steep Slope Pattern,Berkshire NEMO ETC,LLC Evaluation Report 037940.02.12-R11 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 6 of 10 ONEMOjetc. 6.3.1.3 DurationO Premium, TruDefinitione Duration, Duration® Premium COOL & TruDefinition0 Duration® Designer Color Collection: 4-Nail Fastening Pattern SureNaii(P fastening area width Nail,Typical 1" 12" 12" '1" Qw«,s Caro"sng EuMiai{ • m. �:�411iYo • arms cmnwo SuaeHzc� • 6-118" iy518" exposue Figure 9:Standard 4-Nail Pattern,Duration 6-Nail Fastening Pattern SureNa"i*fastening area width Nail,Typical V 12" 12" 1" lP.e,�S:Cort$ryi SuM1n7 • - StWb •IIwenz Cor.inp 3uretxsn+ID • ex{ms,we Figure 10: 6-Nail Pattern,Duration Fastening for Slopes Greater Than 21:12 SureNail®fastening area width Nail,Typical 1" 12" 12" 1" •].—Cairdnp a'NensT—v S.04"a a 6.1/8" 5.518" exposure 2„ Four 1"Spots of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern,Duration NEW ETC,LLC Evaluation Report 037940.02.12-1111 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVH2 EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 7 of 20 ONEMOjetc. 6.3.1.4 TruDefinition®Oakridge®,Oakridge®: 4 Nail Pattern 6 Nail Pattern Esquema con 4 clavos Esguema con 6 clavos T. I.t-- 1r -i►I IE---- 1z"--�►I 5518"Exposure Nails 55ff Exposure Nails Exposici6rrde55/Bprdg Clavas Expasicr6nde5518pu1g. 55/8"Exposure clavos 55/8"Exposure Exposicidn de 56/8paig Exposlc±bn de 5W putg. Figure 12:Standard 4-Nail Pattern,Oakridge Figure 13:6-Nail Pattern,Oakridge Fastening for Slopes Greater Than 21:12 SureNaft fastening area width Nail,Typical 1" 12" 12" 1" ®wens corn;iw smws • anwoa.�o •owcns com�esuex•'. • 6-118" 5.518" eaA�ure 2" Four 1"Spots of Asphalt Roofing Cement Figure 14:Mansard or Steep-Slope Pattern,Oakridge 6.3.1.5 WeatherGuard®HP: 6Nall Pattern Esquema con 6 davos Nail 6118 from bottom of siutgle Cleve a 6118 p*.de bl E po c�dnn dens SM 6 uietadores parts inferior de is tqa Exposi ping. �} 14 IF1 - [Tw P \F/; --I _ — lirdr iisros "' Four V Spots of Asphak Roof Cent 5 5 a Fxpasae 5 5=a ERlaztr� Castro pun6os cemaoto de techa deaslafto de f pvl�rda Exptraiobn da 5 58 pu4 apaaeidn do 5 5i ping. Figure IS:6-Nail Pattern,WeatherGuard HP Figure 16.Mansard or Steep-Slope Pattern,WeatherGuard HP NEMO ETC,LLC Evaluation Report 037940.02.12-Rll Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 8 of 10 ONEMOletc. 6.4 HIP AND RIDGE SHINGLES: 6A.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two(2)nails per shingle. ➢ WeatherGuard'HP Hip and Ridge Shingles and ProEdgee require minimum four(4)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire®Hip and Ridge with Sealant and DuraRidge®Hip and Ridge Shingles with Sealant: Fig. A Fig. B Prevailing Wind Direction Top View �- Direccion del viento predominante Vista superior 1�IH 4 -� Nail eZrn clavo Nails A ! • Owens Coming SireNad` • Clavos 4 Y I I I i I I A I I q i f I R y 6 Y t +(D I ' �EXp0511rE �I C �� i6 dedI VI;r IIIII 4 I I A 12" �I Figure 17:isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge 6.4.1.2 WeatherGuard®HP Hip and Ridge Shingles: Fig,A R 4 Fig.C Hip&Ridge Shingle Fastening '�--Olgrectbn Wtntl Top ftvi Nails-------- Nails Nails p 4 4 I I p" Z., 2 f 1. l I t I I • Exp sure Exposure Figure 19:Isometric View,WeatherGuard HP Hip and Ridge Figure 20:Plan View,WeatherGuard HP Hip and Ridge NEMO ETC,LLC Evaluation Report 037940.02.12-R11 Certificate of Authorization#32465 7i"EDITION t2020)FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 9 of 10 Ali,I NEMO etc. 6.4.1.3 ProEdge®: Prevailing Standard Wind Direction , Fastening Sealant Strip Pattern $'Exposure Y 1" {� •1' 12" tt Sealant Fasten 7l " 7jlf� 6"Expoat Cover Exposed Fasteners with Roof Cement 12"----s Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named CA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777;bwilson@pricmt.com - END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 037940.02.12-Rll Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVH2 EVALUATION F1.10674-1116 Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 10 of 10