Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5150 Milner Dr. A/C
l - - - - --- �i b :� k Ak It f S eILJ ' -Al.TV � e �� .� r 4+ r , ,1 , .. ,.,4 ,; r ,, �r PA Cn� , , , -1 %TrI Gr--r. } a' `, - � copE or CY� an e_ ov4 oT Of ' oN e_ao 1e�1 cemeNT � hi er Y" c �ttp � ec� _WA�e � � � �e � 6 �e e ' eX I nc�ecl w Chi �.�e � w � � h presso.-re-l- PC in C � ec+ricc, � � on -e c C6nCr�+�. poc� k --r) eX+et�el��� ` Utvdetr' (J� ev � ovS ' P I �' Proposal f RWE (Valid for 30 days from Proposal date) PROPRIETARY AND CONFIDENTIAL PROPERTY OF Trane U.S. Inc. DISTRIBUTION TO OTHER THAN THE NAiili'ED RECIPIENT IS PROHIBITEO © 2016 Trane All rights reserved Prepared For. Date:October 1, 2019 St Lucie County BOCC Proposal Number: H6-55903-1 US Communities Quote Number:40-125310-19-017 Job Name: US Communities Contract Number: USC 15-JLP-023 SLC-Milner Health Dept Chiller Repl Delivery Terms: Payment Terms: Freight Allowed & Prepaid 1st Destination/Jobsite Net 30 Days Trane U.S. Inc. is pleased to provide the following proposal for your review and approval. Tag Data -Air-Cooled Scroll (Q : 1) Item ITags) Q Description Model Number A JCGAM060 11 20-130 Ton Air-Cooled CGAM CGAM060F2** Product Data-Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 Air-Cooled Scroll Packaged Chiller 60 nominal tons 460 volt 3 phases 60 hertz High efficiency/performance Full factory refrigerant charge(HFC-410A) With factory installed freeze protection Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety standard ASHRAE 90.1 all versions up to 2016 AHRI certified Factory installed flow switch -set point 60 cm/sec Std cooling (40 to 65F/4.44 to 18C) Grooved-pipe connection Factory insulation 1.25"- high humidity/low evaporator temperature (factory thicker insulation option) Performance based on water High ambient(up to 125F/up to 52C) Lanced aluminum fins w/Professionally-applied protective coating Across the line starter/direct on line Single point connection main line unit power-ancillary items require other power Circuit breaker-high fault rated control panel Enclosure type UL 1995 rated for outdoor applications BACnet interface Hardwired controls card High A short circuit rating (65k A) Elastomeric isolators (Fld) With water strainer factory installed Architectural louvered panels Factory Start-up 5 year Parts; Labor& Refrigerant warranty 6tn-10th year Parts warranty Excludes: Installation, Controls integration labor, Convenience/Service receptacle, Anything not listed above. J:1Jobsl46155903111Proposal- SLC Milner Health Dept Chiller Repl 10-1-19.doc SLC-Milner Health Dept Chiller Repl September 24,2019 -� Total Net Price (Excluding Sales Tax) .................................................................................$ 58,529. Pricing is based on standard lead times. Sincerely, Chris Cowling -Trane U.S. Inc. 6965 Vista Parkway North, Suite 11 West Palm Beach, FL 33411 Phone: (561)683-1521 Cell: (561)683-1521 Fax: (561)697-8714 This proposal is subject to your acceptance of the attached Trane terms and conditions. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Proposal Page 2 of 5 Others t SLC-Milner Health Dept Chiller Repl September 24,2019 r TERMS AND CONDITIONS- COMMERCIAL EQUIPMENT "Company"shall mean Trane Canada ULC for sales in Canada and Trane U.S.Inc.for sales in the United States. 1. Acceptance. These terms and conditions are an integral part of Company's offer and form the basis of any agreement(the"Agreement") resulting from Company's proposal(the"Proposal")for the sale of the described commercial equipment and any ancillary services(the "Equipment"). COMPANY'S TERMS AND CONDITIONS ARE SUBJECT TO PERIODIC CHANGE OR AMENDMENT.The Proposal is subject to acceptance in writing by the party to whom this offer is made or an authorized agent("Customer")delivered to Company within 30 days from the date of the Proposal. If Customer accepts the Proposal by placing an order,without the addition of any other terms and conditions of sale or any other modification, Customer's order shall be deemed acceptance of the Proposal subject to Company's terms and conditions. If Customers order is expressly conditioned upon Company's acceptance or assent to terms and/or conditions other than those expressed herein, return of such order by Company with Company's terms and conditions attached or referenced serves as Company's notice of objection to Customers terms and as Company's counter-offer to provide Equipment in accordance with the Proposal and the Company's terms and conditions. If Customer does not reject or object in writing to Company within 10 days,Company's counter-offer will be deemed accepted. Customer's acceptance of the Equipment will in any event constitute an acceptance by Customer of Company's terms and conditions. This Agreement is subject to credit approval by Company. Upon disapproval of credit, Company may delay or suspend performance or, at its option, renegotiate prices and/or terms and conditions with Customer. If Company and Customer are unable to agree on such revisions,this Agreement shall be cancelled without any liability. 2. Title and Risk of Loss. All Equipment sales with destinations to Canada or the U.S. shall be made as follows: FOB Company's U.S. manufacturing facility or warehouse(full freight allowed).Title and risk of loss or damage to Equipment will pass to Customer upon tender of delivery of such to carrier at Company's U.S.manufacturing facility or warehouse. 3. Pricing and Taxes. Following acceptance without addition of any other terms and condition of sale or any other modification by Customer,the prices stated are firm provided that notification of release for immediate production and shipment is received at Company's factory not later than 3 months from order acceptance. If such release is received later than 3 months from order acceptance date,prices will be increased a straight 1%(not compounded)for each 1 month period(or part thereof)beyond the 3 month firm price period up to the date of receipt of such release. If such release is not received within 6 months after the date of order acceptance,the prices are subject to renegotiation or at Company's option,the order will be cancelled. Any delay in shipment caused by Customer's actions will subject prices to increase equal to the percentage increase in list prices during that period of delay and Company may charge Customer with incurred storage fees. In no event will prices be decreased. The price of Equipment does not include any present or future foreign,federal,state, or local property, license,privilege,sales, use,excise,value added,gross receipts or other like taxes or assessments.Such amounts will be itemized separately to Customer,who will make prompt payment to Company. Company will accept valid exemption documentation for such from Customer, if applicable.All prices include packaging in accordance with Company's standard procedures. Charges for special packaging,crating or packing are the responsibility of Customer. 4. Delivery and Delays. Delivery dates are approximate and not guaranteed. Company will use commercially reasonable efforts to deliver the Equipment on or before the estimated delivery date will notify Customer if the estimated delivery dates cannot be honored, and will deliver the Equipment and services as soon as practicable thereafter. In no event will Company be liable for any damages or expenses caused by delays in delivery. 5. Performance. Company shall be obligated to furnish only the Equipment described in the Proposal and in submittal data(if such data is issued in connection with the order). Company may rely on the acceptance of the Proposal, and in submittal data as acceptance of the suitability of the Equipment for the particular project or location. Unless specifically stated in the Proposal,compliance with any local building codes or other laws or regulations relating to specifications or the location,use or operation of the Equipment is the sole responsibility of Customer. If Equipment is tendered that does not fully comply with the provisions of this Agreement,and Equipment is rejected by Customer,Company will have the right to cure within a reasonable time after notice thereof by substituting a conforming tender whether or not the time for performance has passed. 6.Force Majeure. Company's duty to perform under this Agreement and the Equipment prices are contingent upon the non-occurrence of an Event of Force Majeure. If the Company shall be unable to carry out any material obligation under this Agreement due to an Event of Force Majeure,this Agreement shall at Company's election(i)remain in effect but Company's obligations shall be suspended until the uncontrollable event terminates or (ii) be terminated upon 10 days notice to Customer, in which event Customer shall pay Company for all parts of the Work furnished to the date of termination. An"Event of Force Majeure"shall mean any cause or event beyond the control of Company. Without limiting the foregoing, "Event of Force Majeure"includes:acts of God;acts of terrorism,war or the public enemy;flood;earthquake;tornado;storm;fire;civil disobedience;pandemic insurrections; riots; labor/labour disputes; labor/labour or material shortages;sabotage; restraint by court order or public authority(whether valid or invalid);and action or non-action by or inability to obtain or keep in force the necessary governmental authorizations,permits,licenses,certificates or approvals if not caused by Company;and the requirements of any applicable government in any manner that diverts either the material or the finished product to the direct or indirect benefit of the government. 7. Limited Warranty. Company warrants the Equipment manufactured by Company for a period of the lesser of 12 months from initial start-up or 18 months from date of shipment,whichever is less, against failure due to defects in material and manufacture and that it has the capacities and ratings set forth in Company's catalogs and bulletins("Warranty"). Equipment manufactured by Company that includes required start-up and sold in North America will not be warranted by Company unless Company performs the Equipment startup. Exclusions from this Warranty include damage or failure arising from:wear and tear;corrosion,erosion,deterioration;modifications made by others to the Equipment;repairs or alterations by a party other than Company that adversely affects the stability or reliability of the Equipment; vandalism; neglect; accident; adverse weather or environmental conditions;abuse or improper use;improper installation;commissioning by a party other than Company;unusual physical or electrical or mechanical stress;operation with any accessory,equipment or part not specifically approved by Company; refrigerant not supplied by Company; and/or lack of proper maintenance as recommended by Company.Company shall not be obligated to pay for the cost of lost refrigerant or lost product. Company's obligations and liabilities under this Warranty are limited to furnishing replacement equipment or parts,at its option, FCA(Incoterms 2000) factory or warehouse(f.o.b.factory or warehouse for US domestic purposes)at Company-designated shipping point,freight-allowed to Company's warranty agent's stock location, for all non-conforming Company-manufactured Equipment(which have been returned by Customer to Company. Returns must have prior written approval by Company and are subject to restocking charge where applicable.Equipment,material and/or parts that are not manufactured by Company are not warranted by Company and have such warranties as may be extended by the respective manufacturer. COMPANY MAKES NO REPRESENTATION OR WARRANTY, EXPRESS OR IMPLIED, REGARDING PREVENTION OF MOLD/MOULD, FUNGUS,BACTERIA,MICROBIAL GROWTH,OR ANY OTHER CONTAMINATES. No warranty liability whatsoever shall attach to Company until Customer's complete order has been paid for in full and Company's liability under this Warranty shall be limited to the purchase price of the Equipment shown to be defective. Additional warranty protection is available on an extra-cost basis and must be in writing and agreed to by an authorized signatory of the Company. EXCEPT FOR COMPANY'S WARRANTY EXPRESSLY SET FORTH HEREIN, COMPANY DOES NOT MAKE,AND HEREBY EXPRESSLY DISCLAIMS, ANY WARRANTIES, EXPRESS OR IMPLIED CONCERNING ITS PRODUCTS, EQUIPMENT OR SERVICES,INCLUDING,WITHOUT LIMITATION,ANY WARRANTY OF DESIGN,MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE,OR OTHERS THAT ARE ALLEGED TO ARISE FROM COURSE OF DEALING OR TRADE. 8. Indemnity. To the fullest extent permitted by law,Company and Customer shall indemnify,defend and hold harmless each other from any and all claims,actions,costs,expenses,damages and liabilities,including reasonable attorneys'fees, resulting from death or bodily injury or damage to real or personal property,to the extent caused by the negligence or misconduct of their respective employees or other authorized agents in connection with their activities within the scope of this Agreement. Neither party shall indemnify the other against claims,damages,expenses or liabilities to the extent attributable to the acts or omissions of the other party. If the parties are both at fault,the obligation to indemnify shall be proportional to their relative fault.The duty to indemnify will continue in full force and effect,notwithstanding the expiration or early termination hereof,with respect to any claims based on facts or conditions that occurred prior to expiration or termination. FLD=Fumished by Trane U.S.Inc./Installed by Equipment Proposal Page 3 of 5 Others i t, v SLC-Milner Health Dept Chiller Repl September 24,2019 r 9. Insurance. Upon request, Company will furnish evidence of its standard insurance coverage. If Customer has requested to be named as an additional insured under Company's insurance policy,Company will do so but only subject to Company's manuscript additional insured endorsement under its primary Commercial General Liability policies. In no event does Company waive any rights of subrogation. + 10. Customer Breach.Each of the following events or conditions shall constitute a breach by Customer and shall give Company the right,without an Y election of remedies,to terminate this Agreement, require payment prior to shipping, or suspend performance by delivery of written notice: (1)Any failure by Customer to pay amounts when due; or(2)any general assignment by Customer for the benefit of its creditors, or if Customer becomes bankrupt or insolvent or takes the benefit of any statute for bankrupt or insolvent debtors,or makes or proposes to make any proposal or arrangement with creditors,or if any steps are taken for the winding up or other termination of Customer or the liquidation of its assets,or if a trustee, receiver,or similar person is appointed over any of the assets or interests of Customer; (3)Any representation or warranty furnished by Customer in connection with this Agreement is false or misleading in any material respect when made;or(4)Any failure by Customer to perform or comply with any material provision of this Agreement. Customer shall be liable to the Company for all Equipment furnished and all damages sustained by Company(including lost profit and overhead). 11. Limitation of Liability. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT CONSEQUENTIAL, OR PUNITIVE OR EXEMPLARY DAMAGES (INCLUDING WITHOUT LIMITATION REFRIGERANT LOSS,BUSINESS INTERRUPTION,LOST DATA,LOST REVENUE,LOST PROFITS)EVEN IF A PARTY HAS BEEN ADVISED OF SUCH POSSIBLE DAMAGES OR IF SAME WERE REASONABLY FORESEEABLE AND REGARDLESS OF WHETHER THE CAUSE OF ACTION IS FRAMED IN CONTRACT, NEGLIGENCE,ANY OTHER TORT,WARRANTY,STRICT LIABILITY,OR PRODUCT LIABILITY). In no event will Company's liability in connection with the provision of products or services or otherwise under this Agreement exceed the entire amount paid to Company by Customer under this Agreement. 12. Nuclear Liability. In the event that the Equipment sold hereunder is to be used in a nuclear facility,Customer will,prior to such use,arrange for insurance or governmental indemnity protecting Company against all liability and hereby releases and agrees to indemnify Company and its suppliers for any nuclear damage, including loss of use, in any manner arising out of a nuclear incident,whether alleged to be due, in whole or in part to the negligence or otherwise of Company or its suppliers. 13. Intellectual Property; Patent Indemnity. Company retains all ownership,license and other rights to all patents,trademarks,copyrights,trade secrets and other intellectual property rights related to the Equipment,and,except for the right to use the Equipment sold,Customer obtains no rights to use any such intellectual property.Company agrees to defend any suit or proceeding brought against Customer so far as such suit or proceeding is solely based upon a claim that the use of the Equipment provided by Company constitutes infringement of any patent of the United States of America, provided Company is promptly notified in writing and given authority, information and assistance for defense of same. Company will, at its option, procure for Customer the right to continue to use said Equipment,or modify it so that it becomes non-infringing, or replace same with non-infringing Equipment, or to remove said Equipment and to refund the purchase price. The foregoing will not be construed to include any Agreement by Company to accept any liability whatsoever in respect to patents for inventions including more than the Equipment furnished hereunder,or in respect of patents for methods and processes to be carried out with the aid of said Equipment.The provision of Equipment by Company does not convey any license, by implication, estoppel, or otherwise, under patent claims covering combinations of said Equipment with other devices or elements.The foregoing states the entire liability of Company with regard to patent infringement.Notwithstanding the provisions of this paragraph,Customer will hold Company harmless against any expense or loss resulting from infringement of patents or trademarks arising from compliance with Customer's designs or specifications or instructions. 14. Cancellation. Equipment is specially manufactured in response to orders.An order placed with and accepted by Company cannot be delayed, canceled, suspended, or extended except with Company's written consent and upon written terms accepted by Company that will reimburse Company for and indemnify Company against loss and provide Company with a reasonable profit for its materials, time, labor, services, use of facilities and otherwise.Customer will be obligated to accept any Equipment shipped,tendered for delivery or delivered by Company pursuant to the order prior to any agreed delay,cancellation,suspension or extension of the order. Any attempt by Customer to unilaterally revoke,delay or suspend acceptance for any reason whatever after it has agreed to delivery of or accepted any shipment shall constitute a breach of this Agreement. For purposes of this paragraph,acceptance occurs by any waiver of inspection,use or possession of Equipment,payment of the invoice,or any indication of exclusive control exercised by Customer. 15. Invoicing and Payment. Equipment shall be invoiced to Customer upon tender of delivery thereof to the carrier. Customer shall pay Company's invoices within net 30 days of shipment date. Company reserves the right to add to any account outstanding for more than 30 days a service charge equal to the lesser of the maximum allowable legal interest rate or 1.5%of the principal amount due at the end of each month. Customer shall pay all costs(including attorneys'fees)incurred by Company in attempting to collect amounts due and otherwise enforcing these terms and conditions. If requested, Company will provide appropriate lien waivers upon receipt of payment. Company may at any time decline to ship, make delivery or perform work except upon receipt of cash payment,letter of credit,or security,or upon other terms and conditions satisfactory to Company.Customer agrees that,unless Customer makes payment in advance,Company will have a purchase money security interest in all Equipment to secure payment in full of all amounts due Company and its order for the Equipment,together with these terms and conditions,form a security agreement(as defined by the UCC in the United States and as defined in the Personal Property Security Act in Canada).Customer shall keep the Equipment free of all taxes and encumbrances,shall not remove the Equipment from its original installation point and shall not assign or transfer any interest in the Equipment until all payments due Company have been made.The purchase money security interest granted herein attaches upon Company's acceptance of Customer's order and on receipt of the Equipment described in the accepted Proposal but prior to its installation. The parties have no agreement to postpone the time for attachment unless specifically noted in writing on the accepted order. Customer will have no rights of set off against any amounts,which become payable to Company under this Agreement or otherwise. 16.Claims. Company will consider claims for concealed shortages in shipments or rejections due to failure to conform to an order only if such claims or rejections are made in writing within 15 days of delivery and are accompanied by the packing list and, if applicable,the reasons in detail why the Equipment does not conform to Customer's order. Upon receiving authorization and shipping instructions from authorized personnel of Company, Customer may return rejected Equipment,transportation charges prepaid,for replacement. Company may charge Customer any costs resulting from the testing,handling,and disposition of any Equipment returned by Customer which are not found by Company to be nonconforming.All Equipment damaged during shipment and all claims relating thereto must be made with the freight carrier in accordance with such carrier's policies and procedures.Claims for Equipment damaged during shipment are not covered under the warranty provision stated herein. 17. Export Laws. The obligation of Company to supply Equipment under this Agreement is subject to the ability of Company to supply such items consistent with applicable laws and regulations of the United States and other governments. Company reserves the right to refuse to enter into or perform any order,and to cancel any order, under this Agreement if Company in its sole discretion determines that performance of the transaction to which such order relates would violate any such applicable law or regulation. Customer will pay all handling and other similar costs from Company's factories including the costs of freight,insurance,export clearances,import duties and taxes.Customerwill be"exporter of record"with respect to any export from the United States of America and will perform all compliance and logistics functions in connection therewith and will also comply with all applicable laws, rules and regulations.Customer understands that Company and/or the Equipment are subject to laws and regulations of the United States of America which may require licensing or authorization for and/or prohibit export, re-export or diversion of Company's Equipment to certain countries,and agrees it will not knowingly assist or participate in any such diversion or other violation of applicable United States of America laws and regulations. Customer agrees to hold harmless and indemnify Company for any damages resulting to Customer or Company from a breach of this paragraph by Customer. 18. General. Except as provided below,to the maximum extent provided by law,this Agreement is made and shall be interpreted and enforced in accordance with the laws of the state of New York for Equipment shipped to a U.S. location and the laws of the province to which Equipment is FLD=Furnished by Trane U.S.Inc./Installed by Equipment Proposal Page 4 of 5 Others z SLC-Milner Health Dept Chiller Repl September 24,2019 i shipped within Canada,without regard to its conflict of law principles that might otherwise call for the application of a different state's or province's law, and not including the United Nations Convention on Contracts for the International Sale of Goods. Any action or suit arising out of or related to this Agreement must be commenced within one year after the cause of action has accrued.To the extent the Equipment is being used at a site owned and/or operated by any agency of the Federal Government,determination of any substantive issue of law shall be according to the Federal common law of Government contracts as enunciated and applied by Federal judicial bodies and boards of contract appeals of the Federal Government. This Agreement contains all of the agreements, representations and understandings of the parties and supersedes all previous understandings, commitments or agreements, oral or written, related to the subject matter hereof. This Agreement may not be amended, modified or terminated except by a writing signed by the parties hereto. No documents shall be incorporated herein by reference except to the extent Company is a signatory thereon.If any term or condition of this Agreement is invalid,illegal or incapable of being enforced by any rule of law,all other terms and conditions of this Agreement will nevertheless remain in full force and effect as long as the economic or legal substance of the transaction contemplated hereby is not affected in a manner adverse to any party hereto.Customer may not assign,transfer,or convey this Agreement,or any part hereof,or its right,title or interest herein,without the written consent of the Company. Subject to the foregoing,this Agreement shall be binding upon and inure to the benefit of Customer's permitted successors and assigns.This Agreement may be executed in several counterparts,each of which when executed shall be deemed to be an original, but all together shall constitute but one and the same Agreement. A fully executed facsimile copy hereof or the several counterparts shall suffice as an original. 19.Equal Employment Opportunity/Affirmative Action Clause. Company is a federal contractor that complies fully with Executive Order 11246, as amended,and the applicable regulations contained in 41 C.F.R.Parts 60-1 through 60-60,29 U.S.C.Section 793 and the applicable regulations contained in 41 C.F.R.Part 60-741;and 38 U.S.C.Section 4212 and the applicable regulations contained in 41 C.F.R. Part 60-250 Executive Order 13496 and Section 29 CFR 471,appendix A to subpart A,regarding the notice of employee rights in the United States and with Canadian Charter of Rights and Freedoms Schedule B to the Canada Act 1982(U.K.)1982,c. 11 and applicable Provincial Human Rights Codes and employment law in Canada. 20. U.S.Government Work. The following provision applies only to direct sales by Company to the US Government. The Parties acknowledge that Equipment ordered and delivered under this Agreement are Commercial Items as defined under Part 12 of the Federal Acquisition Regulation(FAR). In particular,Company agrees to be bound only by those Federal contracting clauses that apply to"commercial"suppliers and that are contained in FAR 52.212-5(e)(1). The following provision applies only to indirect sales by Company to the US Government. As a Commercial Item Subcontractor,Company accepts only the following mandatory flow down provisions: 52.219-8; 52.222-26; 52.222-35; 52.222-36; 52.222-39; 52.247-64. If the sale of the Equipment is in connection with a U.S.Government contract,Customer certifies that it has provided and will provide current,accurate,and complete information, representations and certifications to all government officials,including but not limited to the contracting officer and officials of the Small Business Administration, on all matters related to the prime contract, including but not limited to all aspects of its ownership, eligibility, and performance. Anything herein notwithstanding,Company will have no obligations to Customer unless and until Customer provides Company with a true, correct and complete executed copy of the prime contract. Upon request, Customer will provide copies to Company of all requested written communications with any government official related to the prime contract prior to or concurrent with the execution thereof,including but not limited to any communications related to Customer's ownership,eligibility or performance of the prime contract. Customer will obtain written authorization and approval from Company prior to providing any government official any information about Company's performance of the work that is the subject of the Proposal or this Agreement,other than the Proposal or this Agreement. 21. Limited Waiver of Sovereign Immunity. If Customer is an Indian tribe(in the U.S.)or a First Nation or Band Council(in Canada),Customer, whether acting in its capacity as a government, governmental entity, a duly organized corporate entity or otherwise, for itself and for its agents, successors, and assigns: (1) hereby provides this limited waiver of its sovereign immunity as to any damages, claims, lawsuit, or cause of action (herein"Action")brought against Customer by Company and arising or alleged to arise out of the furnishing by Company of any product or service under this Agreement,whether such Action is based in contract,tort,strict liability,civil liability or any other legal theory;(2)agrees that jurisdiction and venue for any such Action shall be proper and valid (a) if Customer is in the U.S., in any state or United States.court located in the state in which Company is performing this Agreement or (b) if Customer is in Canada, in the superior court of the province or territory in which the work was performed;(3)expressly consents to such Action,and waives any objection to jurisdiction or venue;(4)waives any requirement of exhaustion of tribal court or administrative remedies for any Action arising out of or related to this Agreement;and(5)expressly acknowledges and agrees that Company is not subject to the jurisdiction of Customer's tribal court or any similar tribal forum,that Customer will not bring any action against Company in tribal court, and that Customer will not avail itself of any ruling or direction of the tribal court permitting or directing it to suspend its payment or other obligations under this Agreement. The individual signing on behalf of Customer warrants and represents that such individual is duly authorized to provide this waiver and enter into this Agreement and that this Agreement constitutes the valid and legally binding obligation of Customer,enforceable in accordance.with its terms. 1-26.130-4(0614) Supersedes 1-26.130-4(0214) FLD=Furnished by Trane U.S.Inc./Installed by Equipment Proposal Page 5 of 5 Others r �® Submittal Prepared For: Date:September 24, 2019 REV: October 3, 2019 St. Lucie County BOCC Customer P.O. Number: Customer Project Number: Sold To: Job Number: Job Name: . SLC- Milner Health Dept Chiller Repl Trane U.S. Inc. is pleased to provide the.enclosed submittal for your review and approval. Product Summary Qty Product 1 Air-Cooled Scroll The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed Chris Cowling between submittal generation and equipment release, the product Trane performance and submittal data will need to be verified. It is the 6965 Vista Parkway North, Suite 11 customer's responsibility.to obtain such verification. West Palm Beach, FL 33411 Phone: (561) 683-1521 Cell: (561) 683-1521 Fax: (561) 697-8714, Note: • Please review scope for accuracy. • A customer-supplied. 120V circuit is required to power the controls programmable relays—see page 8. J:lJobs146155903120ubmittal- CGAM060 Chiller- SLC Milner Health Dept Chiller Repl 10-3-19.doc I � E Table Of Contents ProductSummary...........................................................................................................................1 t Air-Cooled Scroll (Item Ai) TagData...................................................................................................................................................3 ProductData............................................................................................................................................3 PerformanceData....................................................................................................................................4 Product Data Report-CGAM060...............................................................................................................5 MechanicalSpecifications........................................................................................................................7 UnitDimensions.......................................................................................................................................9 Weight, Clearance& Rigging Diagram................................................................................................... 15 Accessory.............................................................................................................................................. 18 FieldWiring............................................................................................................................................21 4t SLC-Milner Health Dept Chiller Repl September 24,2019 Tag Data- Air-Cooled Scroll (Qt : 1) Item Tag(s) Qty Description Model Number Ail CGAM060 1 20-130 Ton Air-Cooled ( CGAM060F2**2AXB2Al 131 Al AXXA1 D1 A4AXAXXXB CLAM 1 A3A1 D 1 X-L-X Product Data- Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 Air-Cooled Scroll Packaged Chiller 60 nominal tons 460 volt 3 phases 60 hertz High efficiency/performance Full factory refrigerant charge (HFC-410A) With factory installed freeze protection Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety standard ASHRAE 90.1 all versions up to 2016 AHRI certified Factory installed flow switch -set point 60 cm/sec Std cooling (40 to 65F/44.44 to 18C) Grooved pipe connection Factory insulation 1.25" - high humidity/low evaporator temperature (factory thicker insulation option) Performance based on water High ambient (up to 125E/up to 52C) Lanced aluminum fins w/Professionally-applied protective coating Across the line starter/direct on line Single point connection main line unit power-ancillary items require other power Circuit breaker-high fault rated control panel Enclosure type UL 1995 rated for outdoor applications BACnet interface Hardwired controls card High A short circuit rating (65k A) Elastomeric isolators (Fld) With water strainer factory installed Architectural louvered panels Factory Start-up 5 year Parts, Labor & Refrigerant warranty 6th-10th year Parts warranty FLD Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 3 of 23 Others �; v I I I �� I - - I SLC-Milner Health Dept Chiller Repl September 24,2019 Performance Data- Air-Cooled Scroll Tags CGAM060 _Refrigeration capacity( tons 58.13 Total chiller power kW 67.21 Cooling efficient (EER BtuMl-h)) 10.379 NPLV.IP (EER Btu/W-h)) 14.362 IPLV.IP EER (BtuMl-h)) 14.297 Soundpower level (dBA) 90 Sound pressure level (dBA) 63 Refri 'erant R410A -Refrigerant charge circuit 1 Ib 44.0 Refrigerant charge circuit 2 Ib 44.0 Oil charge circuit 1 (gal) 1.90 Oil charge circuit 2 al 1.90 Entering fluid eva F 57.98 Leaving fluid eva F) 44.00 Flow eva m) 99.37 Min flow eva m) 67.10 Min flow PD eva +strainer ft H2O) 4.45 Max flow eva m) 201.40 'Max flow PD eva +strainer ft H2O 35.99 Evap fluid freeze point F 32.00 Fluid pressure drop eva (ft H2O) 6.71 Total PD eva +strainer (ft H2O) 9.40 Evap fouling factor (hr-s ft-de F/Btu) 0.000100 Saturated evap temp circuit 1 F) 38.15 Saturated evap.temp circuit 2 F 38.10 Ambient air temperature (F) 95.00 Altitude (ft) 0.00 Saturated cond temp circuit 1 F 121.68 Saturated cond temp circuit 2 F 121.72 Compressor power input M 59.42 RLA- compressor 1 A A 24.20 LRA- compressor 1A A 197.00 RLA-compressor 1 B A 24.20 LRA- compressor 1 B A 197.00 RLA- compressor 2A A 24.20 LRA- compressor 2A A 197.00 RLA- compressor 2B A 24.20 LRA- compressor 2B A 197.00 Total airflow cfm 55195 Number of fans 6 Fan power kW 7.37 Total fan FLA A 20.20 Single point power MCA A 124.80 Single point power MOP (A) 125.00 Short circuit current rating A 65000.00 Number of compressors 4 Number of circuits 2 Refrigeration capacity steps 4 Shipping weight Ib 4978.3 Operating weight Ib 5033.3 Length in 149.800 Width in 88.400 Height in 84.800 FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 4 of 23 Others ( 0 SLC-Milner Health Dept Chiller Rep[ September 24,2019 Job Information t � 20-130 Ton Air-Cooled r s® Tag CGAM060 Model Number CGAM 60 . Quantity TOPSS version number 220 Unit nominal tonnage 60 tons _ ,r Unit type High efficiency .' General Information Sound attenuator package Super quiet IPLV.IP 14.30 EER(Btu/W-h) Refrigerant R410A NPLV.IP 14.36 EER(Btu/W-h) Refrigeration capacity 58.13 tons Sound power level 90 dBA Full load refrigeration efficiency 10.38 EER(Btu/W-h) Sound pressure level" 63 dBA Note: 'At 30 feet in free field. Evaporator Information Evaporator application Std cooling Fouling factor 0.000100 hr-sq ft-deg F/Btu Entering temperature 57.98 F Saturated temperature-ckt 1 38.2 F Leaving temperature 44.00 F Saturated temperature-ckt 2 38.1 F Fluid flow rate 99.37 gpm Minimum flow rate 67.10 gpm Pressure drop 6.71 ft H2O Pressure drop at min flow rate 4.45 ft H2O Total PD evap+strainer 9.40 ft H2O Maximum flow rate 201.4 gpm Evap fluid type Water Flow switch set point Flow switch set point 60 cm/sc c Evap fluid freeze point 32.00 F Pressure drop at max flow rate 36.0 ft H2O Freeze protection(factory inst) With freeze protection Condenser Information Unit application High ambient Total fan FLA 20.20 A Ambient air temperature 95.0 F Total airflow 55195 cfm Elevation 0.000 ft Fin material Lanced aluminum Number of fans 6.00 Each Saturated temperature-ckt 1 121.7 F Fan power 7.370 kW Saturated tem erature-ckt 2 121.7 F Compressor Information Number of compressors 4 RLA LRA Number of circuits 2 Compressor A 24.20 A 197.00 A Refrigeration capacity steps 4 Compressor B 24.20 A 197.00 A Compressor power input 59.42 kW Compressor D 24.20 A 197.00 A Compressor E 24.20 A 197.00 A Electrical Information Unit voltage 460.volt 3 phases MCA MOP Unit hertz 60.hertz Single point power 125 A 125 A Short circuit High Incoming power line connection Single point Short circuit current rating 65000 A Starter type Across the line Total power input 67.21 kW Note: Unit power includes:compressors,condenser fans,and control kW 9/24/2019 TOPSS version number 220 Data generation date 2/3/2019 Page 1 of 2 FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 5 of 23 Others i I I I I i �i I� I I �, I ��I SLC-Milner Health Dept Chiller Repl September 24,2019 Job Information 20-130 Ton Air-Cooled TRAII/�° Tag CGAM060 Model Number CGAM 60 ;;`" , Quantity 1 I! TOPSS version number 220 . Unit nominal tonnage 60 tons a Unit type High efficiency ' Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program which is based on AHRI Standard 550/590(I-P).Certified units may be found in the AHRI directory at www.ahridirectory.org. Physical Information Length 150 in Water connection(inlet) 3.000 in Width 88 in Refrigerant charge circuit 1 44.0 lb Height 85 in Refrigerant charge circuit 2 44.0 lb Operating weight 5033 lb Oil charge circuit 1 1.90 gal Shipping weight 4978 lb Oil charge circuit 2 1.90 gal Information for LEED.Projects ASHRAE 90.1/CSA compliance ASHRAE all to 2016 IPLV 14.30 EER(Btu/W-h) Refrigerant charge circuit 1 44.0 lb Rated refrigeration Capacity 57.47 tons (AHRI) Refrigerant charge circuit 2 44.0 lb Rated cooling efficiency Note: This product meets the minimum efficiency requirements of ASHRAE Standard 90.1 and CANS/CSA C743 for all versions(which are based on AHRI standard rating conditions)and,therefore,also meets the LEED"Minimum Energy Performance"prerequisite in the Energy and Atmosphere section. The LEED Green Building Rating SystemT°",developed by the U.S.Green Building Council,provides independent,third-party verification that a building project meets green buildina and nerformance measures. 9/24/2019 TOPSS version number 220 Data generation date 2/3/2019 Page 2 of 2 FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 6 of 23 Others � v SLC-Milner Health Dept Chiller Repl September 24,2019 Mechanical Specifications- Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 y Validation Period Product performance, mechanical specifications and submittal data is valid for a period of 4 months from the date of the submittal generation. If 4 months or more has elapsed between submittal generation and equipment release,the product and submittal will need to be verified. It is the purchaser's responsibility to request such verification. 'Foundation Provide rigid, non-warping mounting pads or a concrete foundation of sufficient strength and mass to support the applicable operating weight (i.e. including completed piping, and full operating charges of refrigerant, oil and water). Once in place;the unit must be level within 1/4"across the length of the unit. The Trane Company is not responsible for equipment problems resulting from an improperly designed or constructed foundation. General Units are constructed of a galvanized steel frame with galvanized steel panels and access doors. Component surfaces are finished with a powder-coated paint. Each unit ships with full operating charges of refrigerant and oil. Compressor and Motor The unit is equipped with four hermetic, direct-drive,3600 rpm 60 Hz suction gas-cooled scroll compressors.The simple design has only three major moving parts and a completely enclosed compression chamber which leads to increased efficiency. Overload protection is internal to the compressors. The compressor includes: centrifugal oil pump, oil level sight glass and oil charging valve. Each compressor will have compressor heaters installed and properly sized to minimize the amount of liquid refrigerant present in the oil sump during off cycles. Unit-Mounted Starter The control panel is designed per UL 1995. The starter is in an across-the-line configuration, factory-mounted and fully pre-wired to the compressor motor and control panel. Typically, Trane scroll compressors are up to full speed in one second when started across-the-line. A factory-installed, factory-wired 820 VA control power transformer provides all unit control power (120 Vac secondary) and Trane CH530 module power (24 Vac secondary). A molded case high interrupting capacity circuit breaker, factory pre-wired with terminal block power connections and equipped with a lockable external operator handle, is available to disconnect the chiller from main power. Power Connection Power connections include main three-phase power and two separate 115V, 20 amp customer provided single phase power connections are required to power the heaters (if used for freeze protection) as well as the programmable relays. Short circuit current rating of 65 kA is provided. Evaporator Braze plate evaporator is made of stainless steel with copper as the braze material. It is designed to withstand a refrigerant side working pressure of 430 psig (29.6 bars) and a waterside working pressure of 150 psig (10.5 bars). Evaporator is tested at 1.1 times maximum allowable refrigerant side working pressure and 1.5 times maximum allowable water side working pressure. It has one water pass. A water strainer and a flow switch are factory installed. Immersion heaters protect the evaporator to an ambient of -20OF (-290C). All evaporators have grooved pipe connections. Note:An additional 115V, 20 amp field provided single phase power connection is required to power the heaters(if used for freeze protection). Condenser Air-cooled condenser coils have lanced aluminum fins mechanically bonded to internally-finned copper tubing. The condenser coil has an integral sub-cooling circuit. The maximum allowable working pressure of the condenser is 650 psig (44.8 bars). Condensers are factory proof tested at 650 psig (44.8 bars). FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 7 of 23 Others t \. SLC-Milner Health Dept Chiller Repl September 24,2019 Direct-drive vertical discharge condenser fans are balanced and individually protected. Three-phase condenser fan motors with permanently lubricated ball bearings and external thermal overload protection are provided. The unit starts and operates from 32.0 F to 125.0 F. Refrigerant Circuits The unit has dual refrigerant circuits. Each refrigerant circuit has Trane scroll compressors piped in parallel with a passive oil management system.A passive oil management system maintains proper oil levels within compressors and has no moving parts. Each refrigerant circuit includes filter drier, electronic expansion valve, liquid line and discharge service valves. Capacity modulation is achieved by turning compressors on and off. The unit has four capacity stages. Unit Controls The microprocessor-based control panel is factory-installed and factory-tested. The control system is powered by a pre-wired control power transformer, and will turn on and off compressors to meet the load. Microprocessor-based chilled water reset based on return water is standard. The unit comes with a factory installed flow switch. The Trane CH530 microprocessor automatically acts to prevent unit shutdown due to abnormal operating conditions associated with low evaporator refrigerant temperature and high condensing temperature. If an abnormal operating condition continues and the protective limit is reached, the machine will shut down. The panel includes machine protection for the following conditions: low evaporator refrigerant temperature and pressure, high condenser refrigerant pressure, critical sensor or detection circuit faults, lost communication between modules, phase loss, phase reversal, over temperature protection, external and local emergency stop, and loss of evaporator water flow. When a fault is detected, the control system conducts more than 100 diagnostic checks and displays results. The display will identify the fault, indicate date, time, and operating mode at time of occurrence, and provide type of reset required and a help message. Data contained in available reports includes: water and air temperatures, refrigerant pressures and temperatures, flow switch status, EXV position, and compressor starts and run-time. All necessary settings and setpoints are programmed into the microprocessor-based controller via the operator interface. The controller is capable of receiving signals simultaneously from a variety of control sources, in any combination, and priority order of control sources can be programmed. Communications BACNet Interface allows the user to easily interface using BACNet MS/TP via a single twisted-pair wiring to a factory-installed and tested communication board. External Chilled Water and Demand Limit Setpoint Controls, sensors, and safeties allow reset of chilled water temperature, based on temperature signal, during periods of low outdoor air temperature (chilled water reset based on return chilled water temperature is standard). The demand limit setpoint is communicated to a factory-installed and tested communication board through a 2-10 Vdc or 4-20 mA signal. Programmable Relays Predefined, factory-installed, programmable relays allow the user to select four relay outputs. Available outputs are: Alarm-Latching, Alarm-Auto Reset, General Alarm, Warning, Chiller Limit Mode, Compressor Running, and Tracer Control. Note:An additional 115V, 20 amp field provided power connection is required to power the programmable relays. Architectural Louvered Panels Louvered panels cover the complete condensing coil and service area beneath the condenser. Isolators Molded elastomeric isolators, sized to reduce vibration transmission to the supporting structure when the unit is installed, ship with the chiller. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 8 of 23 Others t c o T INLET/OUTLET WATER fD 3 r- m a CONNECTION SIZE 3"(80mm) 3 '* 0 c D y, BRAZE PLATE 5.0 GAL(19.0 LITERS) p WATER VOLUME/STORAGE ,c w C N Cn C o 0 CD DQ. ((DD CND _ -1 cn 0 Q go o CD 0 m c ISOMETRIC VIEW TOP VIEW c a . 3 m �o 0 ❑ (D o � o0 00 FRONT VIEW RIGHT SIDE VIEW BACK VIEW c O N O W CD SLC-Milner Health Dept Chiller Repl September 24,2019 Unit Dimensions- Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 a \vim 1h z 2 0 W \ LLI Z U / J w ® Q p `^ � vJ Co TH � 1ry�^' V O N � Ij p a N , FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 10 of 23 Others SLC-Milner Health Dept Chiller Repl September 24,2019 Unit Dimensions- Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 Z 0 U w w J Z Z Z)o C Q. rw z� //j } F- W s a U 0 LL coQ Z Q � W J � W LU z 2 11. 0 0 0 F- � Z ~ Op �O W Z z 2 o U - z � O w w U > (r w 0 IL 0 0 M M t0 M UNIT CONTROL PANEL THIS END OF UNIT O io Lo � N N w FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 11 of 23 Others 1 SLC-Milner Health Dept Chiller Repl September 24,2019 Unit Dimensions- Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAMO60 f � 00 ID co .0 \� W f) �\1 z V 0 LL •a i 9 El J 3 W Q 0 J y, Z O U ' F L t e,- FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 12 of 23 Others i t SLC Milner Health Dept Chiller Repl September 24,2019 Unit Dimensions- Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 i wZ QO 30 ~W QO -z 3Z OO o WZ ZO n r (V w W FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 13 of 23 Others c. ti ,_ ;' i SLC-Milner Health Dept Chiller Repi September 24,2019 Unit Dimensions- Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 0 _W U_ o H o W O U) o FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 14 of 23 Others o CD y o UNIT CENTER OF GRAVITY .. LIFTING WEIGHTScb CD r� W1 W2 W3 W4 SHIP I WEIGHT 1 n 4978.3lb CD 0 j 1354.8 lb 1398.3 lb 863.2 lb 890.9 lb (p cb (n � fD o - G) > �v cn rncQ a o m v Q o 0 n ❑ a c 3 cnCG CG C U) — C C 3 d 39.447 in W1-NEAR SIDE W3-NEAR SIDE W2-FAR SIDE W4-FAR SIDE 45.312 in 63.620 in FRONT VIEW SIDE VIEW CONTROL PANEL END cn m cn w c � a m m N U1 _ O W 1 co i _� c o UNIT CLEARANCE : l m n NO OBSTRUCTIONS ABOVE THE CONDENSER D y. TOP VIEW p a as m 31 1/2" 0 CD j90 C � N x 3 n 5 A 39 3/8" CD a _ O m CD - . a O c CL 0 C o c o 3 =::ZN m r=:::ZN r=Z 39 3/8" r cx: 0 47 1/4" -NO OBSTRUCTIONS RECOMMENDED. WORKING CLEARANCE PER NATIONAL Area Required for unit operation,maintenance, CD CODE ARTICLE 110-26. and access panel. m -MORE CLEARANCE MAY BE NEEDED FOR 9 AIRFLOW DEPENDING UPON THE m m INSTALLATION. REFER TO THE CLOSE ro SPACING BULLETIN. , 0 CN w `O o UNIT RIGGING scn cb n CD y' LIFTING A UNIT WITH EQUAL LENGTH STRAPS WILL NOT A (D C' m PRODUCE A LEVEL UNIT DURING THE LIFT BECAUSE G 0- THE CG WILL NOT BE AT THE MIDPOINT BETWEEN THE BASE LIFTING HOLES. THE FOLLOWING ADJUSTMENTS n(D ail s MUST BE MADE TO PRODUCE A LEVEL LIFT. 0 o� 90 a C -SINGLE SPREADER BAR LIFTING METHOD y ;a o IF THE UNIT CG IS CLOSER TO THE CONTROL PANEL, O = THE STRAPS ON THE CONTROL PANEL SIDE OF THE n�• CD SPREADER BAR MUST BE ADJUSTED TO BE SHORTER ,f)to CD THAN THOSE ON THE OPPOSITE SIDE OF THE SPREADER n _ BAR,ALLOWING THE SPREADER BAR TO MOVE TOWARD w THE CONTROL PANELAND OVER THE UNIT CG. U3 CD SEVERAL ADJUSTMENTS OF THE STRAP LENGTH MAY BECX O REQUIRED TO PRODUCE A LEVEL UNIT DURING LIFT. -H-TYPE SPREADER BAR LIFTING METHOD D IF THE STRAPS FROM THE H BAR TO THE UNIT BASE ARE THE SAME LENGTH,THE CRANE LIFTING POINT ON THE n CENTER WEB OF THE H BAR MUST BE ADJUSTED TO G PRODUCE A LEVEL UNIT LIFT. c CL N 3 0 o 3 Q WARNING IMPROPER LIFTING AND MOVING! USE SPREADER BAR AS SHOWN IN DIAGRAM. REFER TO INSTALLATION MANUAL OR NAMEPLATE FOR UNIT WEIGHT. REFER TO INSTALLATION INSTRUCTIONS LOCATED INSIDE CONTROL PANEL FOR FURTHER RIGGING INFORMATION. OTHER LIFTING ARRANGEMENTS COULD RESULT IN DEATH,SERIOUS INJURY OR EQUIPMENT DAMAGE. l7 DO NOTALLOW LIFTING STRAPS TO CONTACT UNIT DURING LIFTI 125 13/16" 07 0 CD m w 23 3/4" cn V N C. ISOMETRIC VIEW CD M � J o CUSTOMER WIRE SELECTION TABLE SHORT CIRCUIT RATING 65kA �' m n N m POWER WIRE CONNECTION TO CIRCUIT BREAKER(1Q1) II j UNIT UNIT VOLTAGE CIR 1&2(SINGLE POINT POWER) s CD y, SIZE EFF LUG WIRE SIZE RANGE(PER PHASE) p Cb gyp- O. 060 HIGH 460 (1 MAX Conductor per phase) D CD#4-4/0 .s n r 0O -a CID C �O N CL T cn •• (p C. 00 o 0 p CD a - o _ rn m O Q 3211/16" 0�0 0000 m 00 C a' B co a y p 75 1/2" C O' ;v FRONT VIEW ISOMETRIC VIEW CUSTOMER CONTROL WIRING CUSTOMER POWER CONNECTION 12KNOCKOUTS 0 0 8 7/16" 4 1/2" o o o b 215J16" 15/16" 11/16" 11 15/16" 5/16" 5 7/6" 24 1/2" m 7 7/16" 3 w 9 Cr co N O O w BOTTOM VIEW CD 1k 9 SLC-Milner Health Dept Chiller Repi September 24,2019 Accessory-Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 MOUNTING LOCATIONS 8 UNIT POINT LOAD WEIGHTS TOTAL OPERATING SIZE WEIGHT 141blQ044 3 4 5 6060 972.1629.81b 761.51b 602.41b 491.81b 5033.3lb MOUNTING HOLE DIAMETER 3/4" CONTROL PANEL 19 9/,6" 1 2 79 1 /16" 130" 3 4 5 6 ti 85 1/16" TOP VIEW DIMENSIONS ARE REFERENCED FROM THE END AND SIDE OF THE UNIT BASE FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 19 of 23 Others � � i s MOUNTING LOCATIONS AND e" a cn r UNIT ISOLATOR NUMBER e n r a SIZE 1 2 3 4 5 6 D N r - 060 RDP RDP-4 RDP-3 RDP-4 RDP-3 RDP-3 _ 7 BRICK RED BRICK RED CHARCOAL BROWN CHARCOAL CHARCOAL j. SEE ISOLATOR POINT LOADS p m FOR DETAILED INFORMATION CD CL ON ISOLATOR LOCATIONS. � „t n j RDP-3 ISOLATORS RDP-4ISOLATORS cQ °o a CD C in C. s co 9/16"DIA N - 9/16"DIA 2 HOLES n0 CD 2 HOLES D OCD y N � a 3 3/8" O 4 5/8" O O 4 118" 5„ c 5 1/2" 6 1/4" co C Q 3 m 1/2"DIA 1/2"DIA 1 5/8" _ 2 7/8" 1/4" 2 3/4" � 3/8" cn m m O N N O O N O N e., L e 1 f M r. -n o CONTROL PANEL ~ 3 CL 0 Cb y II � PAGE 1 OF 2 CD ct)Q sr�NSou'�s uPCONt6Ct 61oH[x (D 6uVlovilOtu�Ll 6M1 W6ET'B" H1 H2 H] > `� M 26]v6]Hz j J' 3 y ]� Q] O6W 66H2 R CD l ^ 0 12 it to 9 T 5 ] 2 1,x 116V 1T1 0) O ,a C w Ni fiM2 SIV y � _. 1 I ) I u Q xt 1tu b l. %4 i. c^ n CD n \G! V0 \ --L-----1--------------�---- 400V SOHZ UNIT IS FACTORY WIRED AS SHOWN. O CD i RECONNECT WIRE 26ATO TERMINALS H2OR H4 _ y Iy NOT CE INSET-B- ED FOR 38OV 50HZ OR 415V50HZ POWER SUPPLIES. E CD uusr e6mrar aura 25A 3BOV 60HZ 26A 25A 575V 60HZ 26A 25A 26A CD 220V SOHZI 23OV60HZ 4I H2 H1 H2 H3 H1 �H2 H341�H4 � INSET-A' o iQ2 G 3 A B C 1D L1 L2 L3 CA sl 6D4 H A B C N� Lt Lz L3 J ' WARNING '-- `-- r 6Q1 HAZARDOUS VOLTAGE! DISCONNECTALL ELECTRIC POWER 6K6 INCLUDING REMOTE DISCONNECTS A B c AND FOLLOW LOCK OUT AND TAG 72 Lt L2 L3 PROCEDURES BEFORE SERVICING. 6K16 INSURE THAT ALL MOTOR _ CAPACITORS HAVE DISCHARGED �� J 6KIl —x— --p— STORED VOLTAGE. UNITS WITH (n BK12 _ VARIABLE SPEED DRIVE,REFER CD ' —' TO DRIVE INSTRUCTIONS FOR USE COPPER CONDUCTORS ONLY] 6K1] 601 CAPACITOR DISCHARGE. CID UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT B OTHER TYPES OF CONDUCTORS. Q 6K15 FAILURE TO DO THE ABOVE cD ' �"- ED �ED, COULD RESULT IN DEATH OR N b �° SERIOUS INJURY. FAILURE TO DO THE ABOVE COULD RESULT IN p o EQUIPMENT DAMAGE. N O W i UJ y"i 1 cn o CONTROL PANEL a PAGE 2 OF 2 CD y A cQ QL � d m n�i o 0 to o 0 Irr) a nN `•D gjq 'J, 0T Y y0 i? ! i ! I , --------------------------------------- - _ . ; ,, rY -- � I � x x 3 N © Ji WARNING �� �1 HAZARDOUS VOLTAGEI DISCONNECTALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCK OUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR USE COPPER CONDUCTORS ONLY! CAPACITORS HAVE DISCHARGED UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT STORED VOLTAGE. UNITS WITH OTHER TYPES OF CONDUCTORS. m VARIABLE SPEED DRIVE,REFER TO DRIVE INSTRUCTIONS FOR FAILURE TO DO THE ABOVE COULD RESULT IN m CAPACITOR DISCHARGE. EQUIPMENT DAMAGE. Q FAILURE TO DO THE ABOVE m cD COULD RESULT IN DEATH OR N SERIOUS INJURY. 0 wCO i-� � SLC-Milner Health Dept Chiller Repl September 24,2019 Field Wiring -Air-Cooled Scroll Item: Al Qty: 1 Tag(s): CGAM060 1D SINGLE SOURCE POWER IS PROVIDED AS STANDARD ON THESE PRODUCTS, FELD CONNECTIONS ARE MADE TO 1 X1.OR 102. E> FOR VOLTAGES 20OV/60HZ,220V/50HZ,38OV/60HZ,460V/60HZ,WIRE 26A SHALL BE CONNECTED TO H2. FOR VOLTAGES 230V/60HZ&575V/60HZ, WIRE 26A SHALL BE CONNECT TO H3. 40OV/50HZ UNIT IS FACTORY WRED WITH 26A CONNECTED TO H3-RECONNECT WIRE 26A TO H2 FOR 380V/50HZ,OR H4 FOR 415V/50HZ. H4 IS ONLY AVAILABLE WITH 40OV/50HZ PANELS. FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP (PTYP=NONE).THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY(PTYP=DHHP). ® CUSTOMER SUPPLIED POWER 115/60/1 OR 220/50/1 TO POWER RELAYS.MAX. FUSE SIZE IS 20 AMPS.GROUND ALL CUSTOMER SUPPLIED POWER SUPPLIES AS REQUIRED BY APPLICABLE CODES.GREEN GROUND SCREWS ARE PROVIDED IN UNIT CONTROL PANEL. WIRED TO NEXT UNIT.22 AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LF22POO14216 RECOMMENDED.THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 4500 FEET.CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN.REFER TO BUILDING AUTOMATION SYSTEM(BAS)COMMUNICATION INSTALLATION LITERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. WIRED TO TRACER OR OTHER TRANE REMOTE DEVICE.22 AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LF22POO14216 RECOMMENDED. THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 4500 FEET.CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN.REFER TO BUILDING AUTOMATION SYSTEM(SAS)COMMUNICATION INSTALLATION LITERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. 7� WIRED TO CUSTOMER CHILLED WATER SET POINT 2-10V OR 4-2OmA. © WIRED TO CUSTOMER EXTERNAL DEMAND LIMIT2-10V OR 4-2OmA. WIRED TO CUSTOMER 2-1 OV OR 4-2OmA %CAPACITY ANNUNICIATOR. 10 WIRED TO TRACER OR OTHER REMOTE DEVICE. 11. REFER TO CGAM ELECTRICAL SCHEMATIC FOR SPECIFIC ELECTRICAL CONNECTION INFORMATION AND NOTES PERTAINING TO WIRING INSTALLATION. 12 ALL UNIT POWER WIRING MUST BE 600 VOLT COPPER CONDUCTORS ONLY AND HAVE A MINIMUM TEMPERATURE INSULATION RATING OF 90 DEGREE C. REFER TO UNIT NAMEPLATE FOR MINIMUM CIRCUIT AMPACITY AND MAXIMUM OVERCURRENT PROTECTION DEVICE.PROVIDE AN EQUIPMENT GROUND IN ACCORDANCE WITH APPLICABLE ELECTRIC CODES.REFER TO WIRE RANGE TABLE FOR LUG SIZES. 13. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND LOCAL REQUIREMENTS. 14. ALL CUSTOMER CONTROL CIRCUIT WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUM INSULATION RATING OF 300 VOLTS.EXCEPT AS NOTED,ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARD MOUNTED BOX LUGS WITH A WIRE RANGE OF 14 TO 18 AWG OR DIN RAIL MOUNTED SPRING FORCE TERMINALS. 15 UNIT PROVIDED DRY CONTACTS FOR THE CONDENSER/CHILLED WATER PUMP CONTROL.RELAYS ARE RATED FOR 7.2 AMPS RESISTIVE,2.88 AMPS PILOT DUTY,OR 3 HP,7.2 FLA AT 120 VOLTS 60 HZ,CONTACTS ARE RATED FOR 5 AMPS GENERAL PURPOSE DUTY 240 VOLTS. 16 CUSTOMER SUPPLIED CONTACTS FOR ALL LOW VOLTAGE CONNECTIONS MUST BE COMPATABLE WITH DRY CIRCUIT 24 VOLTS DC FOR A 12 mA RESISTIVE LOAD.SILVER OR GOLD PLATED CONTACTS RECOMMENDED. 17 FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP.THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY.CUSTOMER SUPPLIED POWER 115V,6OHz,1 PH. 18 CUSTOMER SUPPLIED 3 PHASE POWER. 19 OPTIONAL FIELD ASSIGNED PROGRAMMABLE RELAYS(STAT=PRLY).CLASS 1 FIELD WIRED MODULE,RELAY AT 120V:7.2A RESISTIVE 2.88A PILOT DUTY, 1/2 HP 7.2FLA;AT 240VAG:5 AMPS GENERAL PURPOSE. 20 WIRED TO CUSTOMER 0-10 VDC PUMP SPEED SIGNAL. 21 WHEN FACTORY PROVIDED PUMP IS NOT SELECTED.CUSTOMER MUST SUPPLY SUITABLE PUMP SYSTEM.REFER TO PUMP MANUFACTURER FOR WIRING REQUIREMENTS. THE CONTACTS FOR AUTO STOP AND EMERGENCY STOP SWITCHES ARE JUMPERED AT THE FACTORY BY JUMPERS W2&W3 TO ENABLE UNIT OPERATION.IF REMOTE CONTROL IS DESIRED,REMOVED THE JUMPERS AND CONNECT TO THE DESIRED CONTROL CIRCUIT. 23 IA15,LCI MODULE USED WHEN(COMM=LCI). 24 1A41,BACNET INTERFACE MODULE USED WHEN(COMM=BCNT). FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 23 of 23 Others �` �\ i� /,_