Loading...
HomeMy WebLinkAboutAPPROVED Site Plan SurveyFIELD WORK DATE:REVISION DATES: CERTIFIED TO: DATE:CLIENT ORDER NUMBER: BUYER: SELLER:FLOOD INFORMATIONSURVEYOR’S LEGENDGENERAL SURVEYOR NOTESPERFORMED BYSURVEY NUMBER JOB SPECIFIC SURVEYOR NOTESLEGAL DESCRIPTIONTRANSACTIONPOINTS OF INTERESTPROPERTY PICTUREPROPERTY ADDRESS GOOGLE MAPTHANKS TOUse of this survey other than intended, without written verification, will be at the users’ sole risk and without liability to the surveyor. LB# 8291 | 11940 Fairway Lakes Drive | Suite 1 | Fort Myers, FL 33913 P: 866.735.1916 | F: 866.744.2882 FL1902.1582 2580084 6905 CABANA LANE, FORT PIERCE, FLORIDA 34951 JODI MARIE THOMAS, AARON GRANITO AND LAURA JEAN GRANITO MARK SELF 02/21/19 THE BEARING REFERENCE OF SOUTH 0 DEGREES 08 MINUTES 16 SECONDS WEST IS BASED ON THE EASTERLY PROPERTY LINE OF LOT 16 AND THE EAST ONE-HALF OF LOT 17, BLOCK 150, LOCATED WITHIN LAKEWOOD PARK - UNIT 11, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 11, PAGE 32A THROUGH 32D, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. LOT 16 AND THE EAST ONE-HALF OF LOT 17, BLOCK 150, LAKEWOOD PARK - UNIT 11, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 11, PAGES 32A THROUGH 32D, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. 2/18/2019 JODI MARIE THOMAS, AARON GRANITO AND LAURA JEAN GRANITO; FIRST AMERICAN TITLE INSURANCE COMPANY; FIRST AMERICAN TITLE INSURANCE COMPANY; UMC MORTGAGE COMPANY, ISAOA/ATIMA BY PERFORMING A SEARCH WITH THE LOCAL GOVERNING MUNICIPALITY OR WWW.FEMA.GOV, THE PROPERTY APPEARS TO BE LOCATED IN ZONE X. THIS PROPERTY WAS FOUND IN ST. LUCIE COUNTY, COMMUNITY NUMBER 120285, DATED 02/16/12. 1. 6' WOOD FENCE OVER 10' D.E. AND P.U.E. 1. The Legal Description used to perform this survey was supplied by others. This survey does not determine or imply ownership. 2. This survey only shows improvements found above ground. Underground footings, utilities and encroachments are not located on this survey map. 3. If there is a septic tank, or drain field shown on this survey, the location is approximate as the location was either shown to Exacta Land Surveyors, LLC. by a third party or it was estimated by metal detection, probing rods, and visual above ground inspection only. No excavation was performed in order to determine the exact and accurate location. 4. This survey is exclusively for the use of the parties to whom it is certified. 5. Additions or deletions to this survey map and report by other than the signing party or parties is prohibited without written consent of the signing party or parties. 6. Dimensions are in feet and decimals thereof. 7. Due to varying construction standards, house dimensions are approximate. 8. Any FEMA flood zone data contained on this survey is for informational purposes only. Research to obtain such data was performed at www.fema.gov. 9. All corners marked as set are at a minimum a ½”diameter, 18” iron rebar with a cap stamped LB# 8291. 10. If you are reading this survey in an electronic format, the information contained on this document is only valid if this document is electronically signed as specified in Chapter 5J-17.062 (3) of the Florida Administrative Code and Florida Statute 472.025. The Electronic Signature File related to this document is prominently displayed on the invoice for this survey which is sent under separate cover. Manually signed and sealed logs of all survey signature files are kept in the office of the performing surveyor. If this document is in paper format, it is not valid without the signature and original raised seal of a Florida Licensed Surveyor. 11. Unless otherwise noted, an examination of the abstract of title was NOT performed by the signing surveyor to determine which instruments, if any, are affecting this property. 12. The symbols reflected in the legend and on this survey may have been enlarged or reduced for clarity. The symbols have been plotted at the center of the field location, and may not represent the actual shape or size of the feature. 13. Points of Interest (POI’s) are selected above-ground improvements which may be in conflict with boundary, building setback or easement lines, as defined by the parameters of this survey. There may be additional POI’s which are not shown, not called-out as POI’s, or which are otherwise unknown to the surveyor. These POI’s may not represent all items of interest to the viewer. 14. Utilities shown on the subject property may or may not indicate the existence of recorded or unrecorded utility easements. 15. The information contained on this survey has been performed exclusively, and is the sole responsibility, of Exacta Land Surveyors, LLC.. Additional logo or references to third party firms are for informational purposes only. 16. Pursuant to F.S. 558.0035, an individual employee or agent may not be held individually liable for negligence. 17. House measurements should not be used for new construction or planning. Measurements should be verified prior to such activity. (REV.1 2/21/2019)