Loading...
HomeMy WebLinkAboutAPPROVED Boral Tile1/12/2021 Florida Building Code Online u iWess�� #ulation BCIS Home Z Log In ! user Registration j Hot Topics ; Submit Surcharge Stats & Facts s Publications Contact Us BCIS Site Map Links • Search Ff Ida Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL7849-R13 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Boral Roofing Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (801)380-6091 RobinAnderson@boral.com Authorized Signature Anderson Robin RobinAnderson@boral.com Technical Representative Robin Anderson Address/phone/Email 10701 So. River Front Parkway Suite 300 So. Jordan, UT 84095 (801)380-6091 robinanderson@boral.com Quality Assurance Representative Robin Anderson Address/Phone/Email 7575 Irvine Center Dr. #100 Irvine, CA 92618 (801)380-6091 robinanderson@boral.com Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity IAPMO Uniform Evaluation Services LLC. Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2025 Validated By Gary W. Walker Validation Checklist - Hardcopy Received Certificate of Independence FL7849 R13 COI IAPMO Uniform ES - Certificate of Ind pendence.pdf Referenced Standard and Year (of Standard) Standard Year ASTM C1492 2009 ASTM E108 2016 Equivalence of Product Standards Certified By Sections from the Code www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgf04mGNBAAIXGaCXFLgsFDOP7hRgHBVVfAITEffLOSGD%2bA%3d%3d 1/5 1 /12/2021 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option C 11/09/2020 11/10/2020 11/18/2020 Go to Page tiiN Page 1 / 2 FL # Model, Number or Name Description 7849.1 Barcelona - Impact High Profile - Katy, TX Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion df Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf j Verified By: Gary W. Walker 40455 Design Pressure: N/A Other: I Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7849.2 Barcelona 900 I High Profile -Lake Wales, FL Limits of Use Approved for use in HVHZ: No Installation Instructions Approved for use outside HVHZ: Yes FL7849 R13 II EBS-Instalition pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Impact Resistant: N/A Edition.pdf Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7849.3 Barcelona 900 High Profile Lathrop, CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion pdf Approved for use outside HVHZ: Yes { FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Impact Resistant: N/A Edition.pdf Design Pressure: N/A Other: Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7� 849P4 Bermuda 1 Flat Profile - Okeechobee, FL i Limits of Use ( Installation Instructions Approved for use in HVHZ: No f FL7849 R13 II EBS-Installation pdf Approved for use outside HVHZ: Yes i FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Impact Resistant: N/A I Edition pdf Design Pressure: N/A j Verified By: IAPMO Uniform Evaluation Services LLC. Other: j Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7849.5 ! Cedarlite 600 ( Flat Profile - Stockton, CA Limits of Use Approved for use in HVHZ: No Installation Instructions FL7849 R13 II C darlite Madera -Installation pdf Approved for use outside HVHZ: Yes FL7849 R13 II EBS-In talltion pdf Impact Resistant: N/A Design Pressure: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition pdf Other: Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports ( FL7849 R13 AE UES ER-412 pdf 7849.6 Espana { Barcelona High Profile - Rialto, CA Limits of Use Approved for use in HVHZ: No Installation Instructions Approved for use outside HVHZ: Yes FL7849 R13 II EBS-Installtion pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Impact Resistant: N/A Edition.pdf Design Pressure: N/A Other: Verified By: Gary W. Walker 40455 I Created by Independent Third Party: Yes Evaluation Reports FL7S49 R13 AE UES ER-412 pdf 7849.7 Espana / Barcelona High Profile - Henderson, NV Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion df Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wi d Tile Installation Manual - 6th www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgtO4mGNBAAIXGaCXFLgsFDOP7hRgHBWfAITEffLOSGD%2bA%3d%3d 2/5 1 /12/2021 Florida Building Code Online aenpact Keslstant: N/A Design Pressure: N/A Edition.pdf Other: Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 off 7849.8 Espana 600 / Barcelona 600 High Profile -Rialto, CA Limits of Use Approved for use in HVHZ: No Installation Instructions Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II EB -In talltion pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th E ition.pdf Verified By: Gary W. Walker 40455 Design Pressure: N/A Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 pd 7844.9 Estate "S" Low Profile - Okeechobee, FL Limits of Use Approved for use in HVHZ: No Installation Instructions Approved for use outside HVHZ: Yes FL7849 R13 II EBS-Installation pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Impact Resistant: N/A Edition.Rdf Design Pressure: N/A Other: Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL7849 R13 AE IIES ER-412 pdf 7849.10 Galena Spanish "S" High Profile - Okeechobee, FL Limits of Use Approved for use in HVHZ: No Installation Instructions Approved for use outside HVHZ: Yes FL7849 R13 II EB -Installation pdf FL7849 R13 II Florida High Wind Tile Installation Manual 6th Impact Resistant: N/A E ition pdf Design Pressure: N/A Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7849.11 Madera - 700 & 900 Flat Profile - Stockton, CA Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL7849 R13 II Cgdarlite Mad ra Installation pdf Impact Resistant: N/A Design Pressure: N/A FL7849 R13 II LBS-Instailtio. pa FL7849 R13 II Florida High Wind Tile Installation Manual - 6th E i ion.pdf Other. Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 Ddf 7849.12 Mission S / Barcelona High Profile - Phoenix, AZ Limits of Use Approved for use in HVHZ: No Installation Instructions Approved for use outside HVHZ: Yes L7849 R13 II EBS-Installtion pdf FL7849 R13 II Florida High Wind Tile Installation Manuel 6th Impact Resistant: N/A Edition.pdf Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7849.13 Plantation Flat Profile - Okeechobee, FL Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installation pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th E ition.pdf Verified By: IAPMO Uniform Evaluation Services LLC. Design Pressure: N/A Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE S ER-412 p !d 7849.14 Saxony - Country Shake, Country Flat Profile - Katy, TX Slate, Country Split Shake, English Thatch, Impact, Shake & Slate Limits of Use Installation Instructions Approved for use in HVHZ: No L7849 R13 II EBS-Installtion pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: ICC Evaluation Service, LLC Design Pressure: N/A Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7849.15 Saxony - Shake & Slate Flat Profile - Phoenix, AZ www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt04mGNBAAIXGaCXFLgsFDOP7hRgHBWfA]TEffLOSGD%2bA°/a3d°/a3d 3/5 1/12/2021 Florida Building Code Online I 61111„' "T Ube i Installation Instructions ( Approved for use in HVHZ: No I Approved for use outside HVHZ: Yes FL7849 R13 II EBS-Installation df Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: IAPMO Uniform Evaluation Services LLC. i Design Pressure: N/A Other: Created by Independent Third Party: q Evaluation Reports ! FL7849 R13 AE UES - 412 pdf 7849.16 Slate, Country Slate, Saxony �English Flat Profile - Denver, CO Split OlThatch & Impact Limits of Use Approved for use in HVHZ: No tall Installation Instructions instructions Approved for use outside HVHZ: Yes FL R13 II EBS-Istalltion pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Impact Resistant. N/A Eclition.pLLf Design Pressure: N/A Other: Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports 1`1_7849 R13 AE UES ER-412 pdf 7849.17 Saxony 600 - Slate, Shake & Split Flat Profile - Stockton, CA Shake Limits of Use Approved for use in HVHZ: No Installation Instructions Approved for use outside HVHZ: Yes FL7849 E13 II EBS-Installtion pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Impact Resistant: N/A Edition pdf Design Pressure: N/A Other: Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-4 12 pdf 7849.18 Saxony 600 - Slate, Shake & Split Flat Profile - Rialto, CA Shake Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th E ition pdf Verified By: Gary W. Walker 40455 Design Pressure: N/A Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 pdf 7849.19 Saxony 700 - Shake, State & Split Flat Profile - Stockton, CA Shake T Limits of Use Installation Instructions Approved for use in HVHZ: No 1`1_7849 R13 II EB -Installtion pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile In talla ion Manual - 6th Editlon.pdf Verified By: Gary W. Walker 40455 Design Pressure: N/A Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE ES ER-412 pdf 7849.20 Saxony 700 - Shake, Slate & Split Flat Profile - Rialto, CA Shake Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Install ion p_df Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: Gary W. Walker 40455 Design Pressure: N/A Other. Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412 pdf W 0 Page 1/29 fV Sack Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communleation with the licensee. However email addresses are public record. If you as not wish to supply a personal address, please Provide tine Department wltn an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtO4mGNBAAIXGaCXFLgsFDOP7hRgHBWfAITEffLOSGDd/a2bA°/o3d%3d 4/5 1/12/2021 Florida Building Code Online www.floridabuilding,org/pr/pr app_dtl.aspx?param=wGEVXQMDgtO4mGNBAAIXGaCXFLgsFDOP7hRgHBWfAITEffLOSGD%2bA%3d%3d 5/5 Originally Issued: 07/31/2015 BORAL ROOFING 7575 Irvine Center Drive, Suite 100 Irvine, California 92618 (949) 756-1605 www.boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION 412 Revised: 08/21/2020 Valid Through: 07/31/2021 3.0 PRODUCT USE Boral Roofing Concrete Roof Tiles recognized in this report have been evaluated for use as concrete roof tiles. The weather resistance, wind uplift resistance and fire classification properties of the roof tiles comply with the intent of the provisions of the following codes and regulations: • 2018, 2015, 2012, 2009, and 2006 International Building Code (IBC) • 2018, 2015, 2012, 2009, and 2006 International Residential Code® (IRC) • 2019 California Building Code (CBC) —Supplement attached • 2019 California Residential Code (CRC) — Supplement attached • 2020 Florida Building Code, Building (FBC, Building) — Supplement attached • 2020 Florida Building Code, Residential (FBC, Residential) — Supplement attached 2.0 LIMITATIONS Use of the Boral Roofing Concrete Roof Tiles recognized in this report is subject to the following limitations: 2.1 The roof tiles shall be manufactured, identified and installed in accordance with this report and the applicable code. In the event of a conflict this report governs, 2.2 Boral Roofing "concrete roof tile shall be installed on roof slopes of 21Y2 units vertical in 12 units horizontal (21- percent slope) or greater." IBC Section 1507.3.2. 2.3 The supporting structure shall be designed to support the loads and is beyond the scope of this report. 2.4 The Concrete Roof Tiles recognized in this report are produced in Lake Wales, FL; Brookshire, TX; Phoenix, AZ; Henderson, NV; Okeechobee, FL, Rialto, CA; French Camp, CA; Henderson, CO and Lathrop, CA; Tables 2 A through 2 I describe the tiles produced at each location. 11 General: Boral Roofing Concrete Roof Tiles shall be used as a roof covering in accordance with IBC Section 1503 or IRC Section 903, as applicable. 3.2 Installation: 3.2.1 Installation when installed in accordance with the requirements of the 2018 IBC or IRC: Boral Concrete Roof Tile shall be installed in accordance with 2018 IBC Section 1507.3 or 2018 IRC Section R905.3, including the attachment requirements of 2018 IBC Section 1507.3.7 or 2018 IRC Section R905.3.7, as applicable, Underlayment shall conform to 2018 IBC Section 1507.1.1 or 2018 IRC Section R905.1.1 3.2.2 Installation when the 2015, 2012, 2009 or 2006 IBC or IRC is applicable: Boral Concrete Roof Tile shall be fastened in accordance with The Concrete and Clay Roof Tile Installation Manual for Moderate Climate Regions, dated July 2015, published by the Tile Roofing Institute and the Western States Roofing Contractors Association, and this report.. The TRI manual is available for download attached to ER-2015 from the UES website at www.uniform-es ora. The Concrete Roof Tile shall be attached to the roof structure based on the applicable code and criteria for applicability as noted in Table 1 of this report. TABLE 1 — ATTACHWNT nFCrrty Applicable Design Code Criteria for Applicability Information Location Ultimate Design Wind 2015 or 2012 Speeds (V gt) < 130 MPH Roof Tile IBC and Mean Roof Height <_ 60 Installation feet Manual & Table 1507.3.7 of the 2009 or 2006 Basic Wind Speed (3 sec IBC gust) 5100 mph and Mean applicable IBC Roof Hei ht < 60 feet 2015, 2012, Roof Tile 2009 or 2006 Mean Roof Height <_ 40 feet Installation IRC Manual & Section R905.3.7 r or sic i loot = suD nun, 1 mph = 1.6 m/s 3.4 Anchoring: Boral Concrete Roof tile may be anchored by mortar in accordance with the applicable building code and, where permitted, the TRI Manual or adhesively attached in accordance with the adhesive manufacturer's research report issued by an approved evaluation service agency. The product described in this Uniform Evaluation Service (UES) Report he, been evaluated as an altemative material, design Or method Of constnlchon in Order to satisfy and Comply with the intent of the provision of the code, as noted in this report, and for at least equivalence to that prescribed in the code in quality, strength, effectiveness, fire resistance, durability and safety, as applicable, in accordance with IBC Section 104.11. This document shall only be reproduced in its enfi'rety. Copyright © 2020 by international Association of Plumbing and Mechanical Officials. Ali tights reserved. Printed in the United States. Ph: 1-877-41ESRPT • Fax: 909.472.4171 web: www.uniforrn-es.org - 4755 East Philadelphia Street, Ontario, California 91761-2816— USA ANSI Page 1 of 7 Originally Issued: 07/31/2015 4.0 PRODUCT DESCRIPTION Revised: 08/21 /2020 Boral Roofing Concrete Roof Tiles comply with ASTM C1492 as required by Section 1507.3.5 of the IBC. The roof tiles are described by model, weight, dimensions, and tile factor in Tables 2 A through 2 I, for each of the production locations listed in Section 2.4 of this report. When installed in accordance with this report on minimum 15/32 inch thick (12 mm) plywood solid sheathing or non-combustible decks, the assembly incorporating the roof tiles achieve an ASTM E108 Class A rating per Section 1505.2 of the IBC and Section R902.1 of the IRC, as applicable. Roof classifications for adhesively attached systems shall be in accordance with the adhesive manufacturer's approved research report. 5.0 IDENTIFICATION Shipping pallets are identified with the report holder's name (Boral Roofing), manufacturing address, product name, installed weight, inspection agency, and evaluation report number (ER-412). The Cedarlite 600, Madera 700 and Madera 900 tiles are imprinted on the top side of each tile with an "M", all other filed tiles are imprinted with the name "Boral", "Boral Lifetile", "Monierlifetile", or the Boral Roofing, or MonierLifetile or "Vostile" or logo. The identification includes the IAPMO Uniform Evaluation Service Mark of Conformity. Either Mark of Conformity may be used as shown below: IAPMO UES ER-412 6.0 SUBSTANTIATING DATA Data in accordance with ICC-ES AC180, dated February 2012 (editorially revised March 2018), manufacturer's descriptive litcraturc and installation instructions. Test reports are from laboratories in compliance with ISO/IEC 17025. Valid Through: 07/31/2021 7.0 STATEMENT OF RECOGNITION This evaluation report describes the results of research carried out by IAPMO Uniform Evaluation Service on Boral Roofing Concrete Roof Tiles to assess conformance to the codes shown in Section 1.0 of this report and serves as documentation of the product certification. Products are manufactured at locations noted in Section 2.4 of this report under a quality control program with periodic inspection under the supervision of IAPMO UES. t 1 ° Brian Gerber, P.E., S.E. Vice President, Technical Operations Uniform Evaluation Service Richard Beck, PE, CBO, MCP Vice President, Uniform Evaluation Service GP Russ Chan y CEO, The IAPMO Group For additional information about this evaluation report please visit www.uniform-es.org or email us at infonuniform-es.on! Page 2 of 7 Originally Issued: 07/31/2015 Revised: 08/21/2020 Table 2 A - Tiles Manufactured at Denver (Henn] 12 Valid Through: 07/31/2021 „� rn Installed Dry DimemsionsZ Tile Weights(inch)Tile Factor Length X Width TF (ft3) Ratio s (psf) Saxony — Shake, Slate, Country Slate Split Old English Thatch 9 6 17 X 13 1.568 1.115 Saxon —Impact 10.5 17 X 13 1.568 1.115 Villa 900 9.0 17 X 13 1.503 1.068 Villa-- Impactp Fnr RT- 7 i-1, —')G k .,,,,. 7 _,.r— n oo I__/__2 10.1 17 X 13 1.503 1.068 P­ — • oo is/III Table 2 B - Tiles Manufactured nt NPndPmnn NV Tile Installed Dry Weights DimemsionsZ (inch) Tile Factor Length X Width TF (ft3) Ratio 1 (psf) Espana / Barcelona Saxony 900 — Shake, Slate, Country Slate 9.0 9.1 17 X 123/s 17 X 13 1.470 1.533 1.045 1.090 Fnr R11•1;, I,—nc e..... I., ..—I 1 1l 1 — Y.00 tLg/111 Table 2 C - Tiles Manufactured at Katy (RrnnkehirPl TY Installed Dry DimemsionsZ Tile Weights (inch)Tile Factor Length X Width TF (ft3) Ratio I (psf) Barcelona — Impact 10.3 16'/ XX 13 1.444 1. 227 Saxony — Country Shake, Country Slate, Country Split Shake, English 10.3 16'/z X 13 1.392 0.989 Thatch Saxon — Impact 10.5 161/2 X 13 1.392 0.989 Saxon — Shake, Slate 10.3 161h X 13 1.392 0.989 Tdas Es aiia / Barcelona 9.0 16'/2 X 13 1,407 1.000 Villa Fr CT- 1 it , —')c n .. _ I _..r— n o 9.0 _-2 16s/2 X 13 1.407 1.000 Yoi-- 1ST/III NOTES TO TABLES: 1. Used on a 3-inch head -lap. 2. Nominal dimension. Page 3 of 7 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07131/2021 Table 2 D - Tiles Man,,foPfi.rna n+ T .,i, vu , r r Installed Dry Dimemsionsz Tile Weight' (inch) Tile Factor Length X Width TF (ft3) Ratio 1 (psf) Barcelona 900 9.5 17 X 13 1.525 1.084 Saxony 900 — Shake, Slate, Split Shake, Country Slate 9.5 17 X 13 1.545 1.098 Spanish "S" Nuevo 9.9 17 X 93/4 1.144 0.813 Villa 900 Fnr C.T. 1 (....1, —'1 n ». i _..r— ^ 9.2 _--I 17 X 13 1.533 1,090 TnhlP 2 F -'M.. r ., t__ r. Installed Dry Dimemsionsz Tile Weight' (inch) Tile Factor Length X Width TF (ft3) Ratio s (psf) Barcelona 900 9.3 17 X 13 1.509 1.073 Saxon 900 — Shake, Slate Fnr CT. 1 i-1, — 7Z n ...., i .__r— n 1 9.1 I 17 X 13 1.533 1.090 Tnhle 2 F - THPQ Lw Tile Installed Dry Weights (psf) Dimemsionsz (inch) Tile Factor Length X Width TF (ft3) Ratio I Mission S /Barcelona 10.3 161/z X 13 1.494 1.062 Saxon — Shake, Slate 9.5 16'/z X 13 1.494 1.062 Villa 9.0 161/z X 13 1.407 1.000 Table 2 G - Tiles MannfaetnrPrl of ni .P. hn}.oa 1w Tile Installed Dry Weights(inch)Tile (pst) Dimemsionsz Factor Length X Width TF (ft3) Ratio 1 Bermuda 12.44 161/$ X 1011a 1.036 (j.736 Estate "S" 7.9 16'/z X 13 1.417 1.007 Galena Spanish °`S" 9.3 17 X 10 1.144 0.831 Plantation 10.4 16%z X 13 1.426 1.014 Saxony 900 Fn,- CT. 1 :.,,.1, — )c n ..„..... , .__r— , on ,. _ 9.3 ,. � 17 X 13 1.533 1.090 NOTES TO TABLES: 1. Used on a 3-inch head -lap. 2. Nominal dimension. Page 4 of 7 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 Table 2 H - Tiles Manufactured at Rialto d-A 9 Installed Dry Dimemsions2 Tile Weight' (inch)Tile Factor Length X Width TF (ft3) Ratio' (Pst) Es aria / Barcelona 9.0 17 X 123/8 1.454 1.033 Espana 600 / Barcelona 600 5.9 17 X 123/8 1.454 1,033 Saxony 600 - Slate, Shake, Split Shake 5•9 17 X 13 1.533 1.090 Saxony 700 - Slate, Shake, Split Shake 7.1 17 X 13 1.533 1.090 Saxony 900 - Slate, Shake, Country Shake 9•3 17 X 13 1.533 1.090 Villa 600 5.8 17 X 13 1.494 1.061 Villa 900 9.0 17 X 13 1.494 1.061 For SL• 1 inch = 9S a _ 1 V— A Qo 14 2 0o nr'u Table 2 I - Tiles Manufactured at Stockton tPVPnoh C-1 IA Installed Dry Dimemsions2 Tile Weights inch Tile Factor Length Width TF (ft3) Ratio' (psf) Cedarlite 600 5.9 131/z X 13 0.942 0.673 Madera 700 7.2 13% X 13 0.947 0.673 Madera 900 9.5 131/2 X 13 0.947 0.673 Saxon 600 - Slate, Shake, Split Shake 5.7 17 X 13 1.525 1.084 Saxon 700 - Slate, Shake, Split Shake 7.2 17 X 13 1.525 1.084 Saxony 900 -Hartford Slate, Shake, Slate, Country Slate 9.1 17 X 13 1.533 1.090 Saxon 900 - Split Old English Thatch 9.8 17 X 13 1,525 1.084 Villa 600 6.0 17 X 13 1.494 1,115 Villa 900 Fnr C7- 1 inch = Ir A .,,.,, 7 —,X— a oo L_i___2 9.3 17 X 13 1.494 1.115 .1.1 .. ; i P­ —�_00 xgiui NOTES TO TABLES: 1. Used on a 3-inch head -lap. 2. Nominal dimension. Page 5 of 7 Originally Issued: 07/31/2015 CALIFORNIA SUPPLEMENT BORAL ROOFING 7575 Irvine Center Drive, Suite 100 Irvine, California 92618 (949) 756-1605 www.boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles Revised: 08/21/2020 1.0 RECOGNITION The Boral Concrete Roof Tiles evaluated in IAPMO UES ER-412 is a satisfactory alternative to the following codes and regulations: • 2019 California Building Code (CBC) • 2019 California Residential Code (CRC) 2.0 PRODUCT USE 2.1 The Boral Roofing concrete roof tiles may be used as a Class A, B, or C roof covering systems complying with Sections 1505.1.1 of the CBC or R902.1.1 of the CRC; Sections 1505.1.2 of the CBC or R902.1.2 of the CRC; or Sections 1505.1.3 of the CBC or R902.1.3 of the CRC, respectively. The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with Sections 1507.3.10 and 1513 CBC or Section 905.3 of the CRC, as applicable, and ER-412. 2.2 Roof Tiles shall be installed in accordance with Sections 3.0 and 4.0 of ER-412 except, where the building official requires conformance to the CBC or CRC, the following shall be substituted: 2.2.1 Underlayment shall conform with CBC Section 1507.1.1 or CRC Section 905.1.1. 2.2.2 Attachment of the concrete roof tiles shall be designed to resist wind loads according to CBC Sections 1507.3.7 and 1609.5 or CRC Section 905.3, as applicable. Z.3 Boral Roofing concrete roof tiles may be used in "new buildings located in any Fire Hazard Severity Zone or any Wildland-Urban Interface Fire Area designated by the enforcing agency constructed after the application date shall comply with the provisions" in accordance with Sections 701A.3 and 705A of the CBC, or Sections R337.1.3.1 and R337.5 of the CRC, as applicable, and with the IBC as presented in ER-412. 412 Valid Through: 07/31/2021 2.4 Boral Roofing concrete roof tiles used on structures regulated by the Division of the State Architect or the Office of Statewide Planning and Development are subject to installation provisions in CBC Section 1513. For additional information about this evaluation report please visit EEEInniform-es.or or email us at info(a),uniform-ec or Page 6 of 7 V Originally Issued: 07/31/2015 FLORIDA SUPPLEMENT BORAL ROOFING 7575 Irvine Center Drive, Suite 100 Irvine, California 92618 (949) 756-1605 www.boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles Revised: 08/21/2020 1.0 RECOGNITION The Boral Roofing concrete roof tiles evaluated in IAPMO UES ER-412 is a satisfactory alternative to the following codes and regulations: • 2020 Florida Building Code, Building (FBC, Building) • 2020 Florida Building Code, Residential (FBC, Residential) 2.0 LIlVIITATIONS 2.1 Verification shall be provided that a quality assurance agency audits the manufacturers quality assurance program and audits the production quality of products, in accordance with Section (5)(d) of Florida Rule 61G20-3.008. The quality assurance agency shall be approved by the Commission (or the building official when the report holder does not possess an approval by the Commission). 2.2 Evaluation to the high -velocity hurricane zone provisions in Section 1512 of the FBC, Building and Chapter 44 of the FBC, Residential is beyond the scope of this report. 3.0 PRODUCT USE The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with the 2018 International Building Code and the 2018 International Residential Code, as applicable, as noted in ER-412. From FBC, Building Section 1507.3 and FBC, Residential Section R905.3 states that the installation of the Boral Roofing concrete roof tiles "shall be in accordance with the requirements of the FRSA/TR1 Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition where the Va.,d is determined in accordance with" FBC, Building Section 1609.3.1, FBC-Residential Section R301.2.1.3, or the recommendations of RAS 118, 119 or 120. Load combinations shall be in accordance with Sections 1605.2 or 16053 of the FBC, Building, as applicable. Design wind 12 Valid Through: 07/31/2021 loads shall be in accordance with Section 1609.5 ofthe FBC, Building or Section R301.2.1 of the FBC, Residential, as applicable. For additional information about this evaluation report please visit wwiv.uniform-es.org or email us at iatfoia?uniform-es.or Page 7 of 7