HomeMy WebLinkAboutLomanco Aluminum RV FL#3793.2Florida Building Code Online
Page 1 of 2
-
i.
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
b'p'r
'� Product Approval
USER: Public User
Product Anoroval Menu > Product or Application Search > Application List > Application Detail �j
FL # FL3793-R8 L v t�
Application Type Affirmation
Code Version 2020
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and
ratified by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Lomanco
2101 West Main St
Jacksonville, AR 72076
(501)983-6163
kjelley@lomanco.com
Katrina Jelley
kjelley@lomanco.com
Andrew Carter
2101 West Main Street
Jacksonville, AR 72076
(501)982-6511 Ext361
acarter@lomanco.com
Andrew Carter
2101 West Main Street
Jacksonville, AR 72078
(501) 982-6511 Ext 361
acarter@lomanco.com
Roofing
Roofing Accessories that are an Integral Part of the Roofing
System
Certification Mark or Listing
Miami -Dade BCCO - CER
Miami -Dade BCCO - VAL
Standard
TAS 100A-95
Year
1995
,/, I affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes No 1 N/A
liffn•//xxrcxrtxr f r%r;Ankiiilrlinrr nrrr/nr/nr ann rltl 1 /7Q/1)()71
Florida Building Code Online
Page 2 of 2
Product Approval Method Method 1 Option A
Date Submitted 12/16/2020
Date Validated 12/16/2020
Date Pending FBC Approval
Date Approved 12/23/2020
Summary of Prnd—tc
FL #
Model, Number or Name
Description
3793.1
LPR Low -Profile Ridge Vent
Aluminum Ridge Vent
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL3793 R8 C CAC Lomanco VUR LPR - NOA 16051024.odf
Quality Assurance Contract Expiration Date
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
08/17/2021
Design Pressure: N/A
Installation Instructions
Other: 1. Refer to applicable building codes for required
FL3793 R8 II Lomanco VUR LPR - NOA 16051024.odf
Verified By: Miami -Dade BCCO - CER
ventilation. 2. Ridge vent ventilators shall not be installed on
roof mean heights greater than 33 feet.
Created by Independent Third Party:
Evaluation Reports
FL3793 R8 AE Lomanco VUR LPR - NOA 16051024.Ddf
Created by Independent Third Party: Yes
01
3793.2
VUR Val-U-Ridge Vent
Aluminum Ridge Vent
-WatWirof use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL3793 R8 C CAC Lomanco VUR LPR - NOA 16051024.Ddf
Quality Assurance Contract Expiration Date
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
08/17/2021
Design Pressure: N/A
Installation Instructions
Other: 1. Refer to applicable building codes for required
FL3793 R8 I1 Lomanco VUR LPR - NOA 16051024.Ddf
Verified By: Miami -Dade BCCO - CER
ventilation. 2. Ridge vent ventilators shall not be installed on
roof mean heights greater than 33 feet.
Created by Independent Third Party:
Evaluation Reports
FL3793 R8 AE Lomanco VUR LPR - NOA 16051024.Ddf
Created by Independent Third Party: Yes
Back Nazt
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
necle:t
Credit Card
Safe
oil
1.+T.-..//..... ,.., C1,...: A-1-..:l a:.-„ ___/..... I— -10 .. ,...._.n... ,.. ..,i' T7 I lvl%._. Tl,. ,.0 T)I-'V_. _Of. 1 /110 /'1 nr1,
MIAMI•[1►1�DE
® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) w,vw.miamiaade.f!ov/cconomv
Lomanco, Inc.
2101 West Main Street
Jacksonville, AR 72076
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: VUR & LPR Ridgevents
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.11-0602.01 and consists of pages 1 through 4.
The submitted documentation was reviewed by Gaspar J Rodriguez.
�i
MIAMI•DADE COUNTY
NOA No.: 16-0510.24
Expiration Date: 08/17/21
Approval Date: 07/28/16
Page I of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Ventilation
Material: Aluminum
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
VUR Ridgevents
LPR Ridgevents
2": Height TAS 100(A)
8.125": Width
10':Length
0.025": Min. thickness
3.625": Height TAS 100(A)
9.875":Width
8'and 10':Length
0.025": Min. thickness
MANUFACTURING LOCATION
1. Jacksonville, AR
Aluminum static louvered roof ridge
ventilation system.
Aluminum static louvered roof ridge
ventilation system.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Intertek-ATI F7517.01-801-18 TAS 100(A) 07/08/16
NOA No.: 16-0510.24
%M'DADECOW Expiration Date: 08/17/21
Approval Date: 07/28/16
Page 2 of 4
APPROVED ASSEMBLIES:
Trade names: VUR & LPR Ridgevent
System Type C: Mechanical attachment of static ridge vent over composite shingles.
Cutout: Refer to manufacturer's published literature
Installation: Install end plug on the end of the vent sealed with 100% silicone sealant. VUR & LPR
Ridgevent shall be 6" longer than ventilation slot as to provide a base for the end plug.
Apply '/4" wide bead of 100% silicone sealant caulk to the bottom flange of the VUR & LPR
Ridgevent sections close to where roof hole will be after vent is installed. Align end of first
section on the end marks and the bottom of the nailing flange on the chalk line (4" down on
both sides of the ridge peak for VUR vent; 5'/4" down on both sides of the ridge peak for LPR
vent). Nail the VUR & LPR Ridgevent in place using 11 gauge 2" galvanized smooth shank
roofing nails through the factory formed holes, with the first nail 1'/2" to 2" form the vent end.
All nail heads and vent section joints shall be sealed with 100% silicone sealant.
Install Hurricane Straps over each end of ridge vent, all connections between sections and at 3'
intervals over the remainder of the vent using four 1 %" galvanized ring shank -roofing nails per
strap.
Ventilation
Calculations: Refer to manufacturer's published literature
Minimum Slope: 3:12
NOA No.: 16-0510.24
Expiration Date: 08/17/21
Approval Date: 07/28/16
Page 3 of 4
GENERAL LIMITATIONS:
1. Refer to applicable Building Code for required ventilation.
2. VUR & LPR Ridgevent shall comply with all applicable building codes.
3. VUR & LPR Ridgevent shall not be installed on roof mean heights greater than 33 feet.
4. VUR & LPR Ridgevent shall comply with the Florida Building Code (FBC)
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
DETAILS
LPR Ridgevent
F
I
120"
or 96"
i
VUR Ridgevent
2" REF ,J (---------------- -- I
8-6 RE 12T
END OF THIS ACCEPTANCE
. .
1 APPROVED
4i
NOA No.: 16-0510.24
Expiration Date: 08/17/21
Approval Date: 07/28/16
Page 4 of 4