Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TREFELNER-PERMIT DOCUMENTS
Anxrocw A'_."C*"WY ■ Corrugated stainless steel. tubing (CSST) gas piping systems will be bonded in accordance with* Section G2411.1(310) of the Florida Building Code and NFPA 54. ■ Underground gas piping will be installed at a MWmum depth of 12 inches below grade in accordance with Section G2415.12 (404.12) of the Florida Building Code and NFPA 58. Polyethylene pipe will be installed in accordance with 6.11.4 of NFPA 59 and the Florida Building. Code. Carbon monoxide monitors will be installed prior to inspection and will meet all code and safety requirements of NFPA 54 and the Florida Building Code. Application Materials Ideal for use as a first stage regulator on any domesifo size ASME or DOT container In propane gas Installations requiring up to 1,600.000 BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Features Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. • Large threaded -W F.NPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. Non Adjustable Large flow orifice resists freeze ups due to water concentration in LPG vapor. • Design provides for good flow regulation at both high and low container pressures. • Built In relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates V F.NPT downstream pressure tap for an easy Wine check of the regulator's delivery pressure. • Molded diaphragm provides an o-ring type seat between the body and bonnet. • Body and bonnet are assembled In the USA using the unique, patented RegUlok seal system. ................. Zinc Bonnet..................WWW ........................ ...•.•........... ,.............Steel Spring ..................... .... �.......................... ...•..........Resilient Rubber Seat Disc ................. .• " Diaphragm ,..,.......,.. irate rated Fabric and Synthetic Rubber W .--- 3 • Fully painted In brilliant red for complete corrosion protection. u • Mounting bracket available as an accessory: part number 2302-31, Ordering Inforlrnation eTUM- a9,000 0lOp1 75 OK 1W.000 FLOW ppOPAM MOM- 10 PSIG 1,500.000 1W 1 NPT W F.NPT '� 9:00 LV3403TRV9 reswrO 20% Iowvar mar, we regulabseWg and dallmy pressura 20%lower man the setling. • miudmumtlsw bssed on inlat pressure 20 PSIG higher than ete regulator setling and delivery p Ail i #WM&7 goo Rego Dr. P.O. eoxT47 FJon, T1G 27244 USA www.ragoproducts_com l'v. {336) 444-77G7 Fair 3381498.8594 Y�'i; .:z:,r. Designed to reduce tot stage pressure of 6 to 20 PSJG down to burner pressure, normally 11' w.c. IQeal far medium commercial Installations, multiple cylinder installations and normal domestic loads. Ftm Large vent helps prevent blockage and has %" F.NPT for vent piping- • UIlilh 15 PSIG inlet pressure, regulator Is designed to not pass more than 2 PSIG with the seat d[sc.removed. Incorporates Integral relief valves. • Replaceable valve orifice and valve seat dlsa • Straight line valve cdasure reduces wear on seat dlso. Unique bonnet vent profile minimlzes vent freeze over when properly installed. • Large molded disphnm is extra sensitive to pressure changes. • 6ullt In pressure tap has plugged 1W F.NPT outlet Plug can be removed with a 3l16' hex den wrench, • Select brown finish. Eft Mounts directly to hnusa kne piping. Eliminates need for union joints, elbows, and mounting brackets. Quick and easy to install. • Bsehmount despn M dmmn flaw rased on 10 P&r6 klet and 9' w.m Mvefy pressure, L Eake aw Body..... .................. I...n..................,..,.... ,.............. pie Cast Zinc. Bonnet .................... Diu Cast Zinc Nazda Orifice ...... _..•................................................13rass Spring...................... .,.............. »...I ......... ........ ..4-....... Steel Valve Seat Me ...... -- — .............................. RBslllent Rubber Dlaphragm ...............• Integrated Fabric and Synthetic Rubber G 100 Rego ar. P.O. Box 297 Eton, NC27244 USA www.fegepmducbm•corn Phmapg 144ge 1707 Fex (938)44"s9d -ANWO capynghl 2017 National Fire Ptotaeson Association (NFPAO). Cleansed, by agrearnen4 for Individual use and download on 12n11017 to AmedGas for designated user arlen peed. Na other rsproduede or Irenemtaslon in permitted without written permission of NFPAS, Fat JNUIdes or t0 report unauthorized use, cantaol fleensing@nfpa,org. Chapter 16 • Pipe and Tulaing Sizing Tables TABLE 16.1(n) Po1y4111ylehe Pdastic Pipe-1FS Gas,' Undifuied Propane Inlet Pressure; 10.0 psig Pressure Drop: 1.0 psig Spedt'ic Gravity: I.S2 Plastic P47 a 1/s iM .Length SDR 9.33 SDR 11 Vt.) (0,660) (0,8t50} SDR 11 i 1.007 i SDR I! � SDR I! SDR 11 INT NDEU II,�E;°Sizing Between First=Stage ptr ssttre (1.328) (7.554) (1,943) egu7atar a.ird See {.Loft/ .Pressure) Re ttlrrtar 30 2140 40 1840 2390 3670 7740 13420 20100 36400 50 1630 3260 6630 Sg7Q 11480 10180 17300 15400 31200 60 1470 70 2950 5320 9220 11900 27600 1360 2710 4900 8480 12800 25000 2.1coa 8o 1260 90 1180 2530 2370 4560 7890 11900 21400 100 1120 2240 4270 4040 7400 11200 20100 125 990 990 1580 6990 10600 19000 150 $97 897 3240 6200 5620 9360 16800 8480 15200 175 826 200 778 826 778 2980 5170 7800 14000 225 721 721 2780 2600 4810 7810 12200 250 6$1 2460 4510 4260 6Q 10D 275 6 681 1 2140 4050 6430 6110 11600 11000 300 617 350 567 617 567 2230 I 3860 5810 19640 400 ,528 528 2050 1910 3550 3300 5360 450 495 495 992 3100 4990 4680 8970 8970 500 468 468 937 2930 4420 8410 7950 600 424 700 390 424 390 849 2650 4010 7200 800 363 .163 j 781 726 2440 3b90 6620 90(i 340 340 682 2270 2130 3430 3220 6160 1000 322 322 644 2010 1040 5780 5460 1500 258 2000 221 258 221 517 933 1616 4390 443 498 1383 1750 1PS: Iron Plpa Size, SDk: Standard Dimension Ratio Notes: (1) Capacities are in 1000 B Whr. (2) Dimensions in parentheses are inside diameter, 2017 LP -Gas Code Handbook 7/32, 7x19 GALV. CABLE 5600# BREAKING STRENGTH W/(2)HDG CLAMPS TC ANCHOR (PULLED TIGHT) CABLE SHALL BE COATED, SLEEVED OR HAVE 1 LAYER 30# FELT AGAINST TANK / 7/16" GALV. CABLE W/ (2)HDG CLAMPS TO ANCHOR (PULLED TIGHT) 5/8"X40A SINGLE 6° HELIX O 2"X3 / Q SINGLE 4 HELIX HELICAL ANCHOR NOTE: 2 PAIRS 1475#/ANCHOR 500 GALLON LINDERGROUND HOLD DOWN DETAIL � ,1�;Illill�j� �o 40111 •� LO O STATE OF 'tL a• r\ I� V •.��.ffu.1•• ��illlili7<��� 2019-03-18 GENERAL NOTES: 1. HELICAL ANCHORS SHALL HAVE A PULL—OUT CAPACITY AS SHOWN. ANCHORS SHALL BE INSTALLED PER ANCHOR MANUFACTURER TO ACHIEVE STATED LOAD CAPACITY, CAPACITY VARIES WITH SOIL TYPE, VERIFY ANCHOR CAPACITY WITH SOIL TYPE ENCOUNTERED. 2. CHECK FOR UNDERGROUND UTILITIES PRIOR TO ANCHOR INSTALLATION 3. LOCATION OF TANK RELATIVE TO ADJACENT STRUCTURES AND FEATURES ARE DEPENDENT UPON LOCAL CODES AND IS THE RESPONSIBILITY OF OTHERS. 4, THE TANK AS SHOWN HAS BEEN DESIGNED TO PREVENT FLOTATION. COLLAPSE, OR LATERAL MOVEMENT DURING THE BASE FLOOD EVENT CONTRACTOR TO LOAD TEST 4" ANCHORS AFTER INSTALLATION 0 COPYRIGHT 2018 — FARLEY ENGINEERING, LLC AMERICAS FARLEY ENGINEERING LLC Consulting Engineer #40111 — CA28108 8800 N. U.S. #1, Suite #2 , Sebastian, Florida 32958 Llr� (772) 589.6229 (772) 589.2296 fox LM M �O, r - _ a _ ON eV a. fV v1 41'1 co 00 M het �' LgQ e.N� Ch ^ b Cp lrD 00 ry-. b - 0o ^ P �. �`. b m a a N- rn LO W Lo.� N 1[7 N N CQ u n th N M W •" -N - In � n N � +D E ch m Lneq CI r_ N M W C2 ! fV _ m Ri a ST - N Kl QNi W N N r S � fNV M Le) e n MD tl 8 ^ $E L 10 _N it ry c ~' ID ry LnLp n 2 n N in I^w w mL11 o"'a 00 L% .. N N. V' tli r Q pOO .�... U j" m n h CIO. n n m N ,12 7 P C C `0 2 Inm O5Ch rd c a m m W °i m c s N �A nV . �y + a o n ry m h J LiDNA � N ^ � -8 c 7 ' m N rai b o pp J 0 zh �e u R v p us OLi �n �. �' .c c ryp co cc Q h ° M ..M3 N Q �+' M U 5 C! N SL �] _ N O c U a j 0 7+ - In gc N cc 4 re Q ti o N LM n r N rN. V W N a t� :�$ �p4�p' ry ,ray n �. a $ N O. G h v! _ y Oh y� [0 OQ � m . tr1 N Dz v '� C U D_ E V a -fna` b "N rC E o o N M n c S a �n 8` rp in T M s W $$- L}Z N y W E r M ^ n $ E N N 'x ^ r' N tt 00 b ^ m b m $ 4 rn.h Ln h o e 2 co C EO W M D h Ln _ o P S ry Q r C m Nm yu� M %D -m w d o + CI rv. � c m 9- 1T 0_0 N � i s M M .- N AmeriGas is pleawd to offer the following proposal for your consideration: Trefelner constrtictlan Customer Name 5040 Sattthwirtd.Trail Street Fort Pierce, FL City. 6tate, zip cotfe house Bondin of jns line (q builders res nsiblU y Tank trust be 10 feet off of ro 11 ,srid V fm off of hopseW code. Quantliv Deecrit7tlon B[ian Pearl Sales Representatfva Fort.Pierda District kuaation 772-633.0740 Telephone Unit Cost Total 400 Pro ane .29 $916M 1500 Gallon Tank l595 $1596.00 1 Bury and Anchor Tank per Code 885 $885.00 1 Anode for Cathodic Protection 100 $1 Q0.00 3i4" Exterlbr Gas Line MCl to txllad t t`e foul based on 5nal tank. and S6Q Iccslion) $ $600.00 2 Tee 125 $250,00 4 Gas Connections �., ' c.-,'yam !` 125 550b.00 6 Shut Offs I flex lines 25 $150.00 4 Regulators 70 $280.00 4 Transitions 65 $260.00 1 Quick disconnect with 5 ft hose for BSQ 75 $75.00 b/4 INT gas fine 16 $640.00 TAX I 7.00°f $373.45 Perrnli 1 $250.01) All prices are extilusivs of sMlkcsbfe taxes, pl nbft and electrical warts. ITOTAL CCST $6, B7'4.45 All pribes are.hased on a standan l InsWatim. Unbrese n eirurmataneea srrh an p*vp sad eondlfton, premature pnstellation of concrete, landscaping, st+Whmk atc may result In tncreased casts. Charge orders must ties approied prior to installation and are.suhjedt to opprovel lay the auphortty having jurladtctba.:4mertf 841 WX nut b® ns 92M%M for &Mane w unmaldW- 112M 4snrfrt t der, fitgwgj, . ALL.WORK SHALL BE PERFORMED ACCORDING TO FEDERAL, STATE AND LOCAL REQUIREMENTS. Wan Pearl Submitted by. Thls proposal Is vWW top 30 days from the date submlited. [late 2P M021 Baser=# E. x� Permit # _� _ F CE # 41&4 NTY pr a _(RculT cauor Tax Folio # - OR BOOK0� 004 i f: NECOiDIG� � E �E 1916. 18i �a Tyr©: NC Prepared by: Summer Sagmves MIDFLORIRA Cfadit Union 3004 S. Rarida Ave Lakeland, FL 33803 MICIFLORIDA Credit Union Notice Of Commencement State of Florida County Of Saint Lurie Tina undersigned hereby informs you thrlt iniprovamanls will be made to cortain real property, and in accordance with Section 713, f-lorlda statutes, the fuflowing Information 15 providers In tlifs Notice at Commeneernent. 1. €]escription of property: 5242 Soulhwlnd Trl Fort Pturcrs• FL 341961 Legal bes(Niptian: iltc lard, 1 ? u! Ilia N114111kuQhl r .1 Of the &44l1k%C11 121 ttl the !�,irllln;sl 1'•I urtlkc lV1.rtltcir.t a. Ir•�,�; IhC SYcis .,., IVIq „• autll F71n_. Ili 1CG{kt7p Ili. lutrnxlip 34 gnuth, Ii.,rnrL: du l•..lil•'•rl Lncle. t.'uluns. Fhtndcl 2. General descfiplion of Improvements: SINGLE FAMLY RES10iENCE 3. Owner Inforrrlarion: Linda O`Quinrn 32 Harbour Isis West Fort Pierce, FL :34940 4. Contractor. Trefolner Canstruciion Inc 1760 C'openhsver Rd FartPiaroo, t=1_ 34945 5. Lender: M4IDPLORIDA Credit Union Attn' Mortgage SerAring Departn;ont 3004 S. Florida Avenue Lakeland. FL 33803 6. The owners also designate Thete; a O'Brien of MIL)FL©RIDA Credit Union to recerve a copy of the Lien's Notice as provided in SprAlon 713.13(i) tb), Florida Slatoles. 7. Expiration date of corl' mGnCGMenl is t year from the date of recording Cornmencentent Of said improvernent shall begirt within thirty (30) days from clate of recording this notice WARNING TO OWNER: ANY PAYMENTS h=2 SY THE OWNER AFTER THE RXPZRATION OE THE NOTICE OF COMMNCEMENT ,ARE C0NS:f0ER2D 1Mt7ROPL t UNDER CRAPTER 713, FART 1, SECTION 713.13 FLoRIt1A STATuTEs, AND rAN RESULT IN YOUR PAYING TWICE FOR IMPROVEIMTS TO YOUR PROPERTY, A NOTICE OF CObU.MNCEMENT MUST RE RECDI ZD AtTD POSTED ON THE .SOB SITE R&FOPM THS FIRST rNOFECTION. It XOII ItTFE`JD TQ QBTAIH FIN"CING, CONSULT YOUR LENDER OR AN ATTORNEY BruFa tE COMMENCING WORK OR RECORDING YOUR NOTICE Off C01001WONT , VERIFICATION PURSUANT TO SECTION 9I_525, FLORIDA STATUTES. UNDER PENALTIES OR PERJURY, l DECLARE THAT I HAVE READ THE FOREGOING AND THAT THC FACTS STATED IN IT ARE TRUE TU THY; BEST OF MY KNOWLEDGE ARID BELIEF. fJ stead this day ' oI 21) ��ittrlrrurra Lind' 0a0non State of Florida countyal,__.� t`1C'4djr ��"��� ePd trip► (s�4�b'• � � G3-NiundetT;.•�p' ,4�•� i(�� STAT E,a�tti�ti��, Th tri eguing Ins may t was acknpwledpW before me by rnaans ct ysical Ixre;ertce 01�`1I Jf���r���i,,ratdrizytipn, this ](d day of t t alt� Q, by Unda Gngnon O'gteinn has , prndured _ } ^atary and , who is/are personally known to me or who :1sidentification. Public -State o ido hlOtarySeftl ,�� s,tb' Processed C&M: 10/13/20