Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUPPORTING DOCS
WHY CHOOSE QUALITY STEEL UNDERGROUND TANKS? • 120 - 1,990 WG CAPACITY • General Specifications • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1. • Complies with NFPA 58. • Rated at 250 psig from -200 F to 1250 F. All vessels registered with National Board. • Two service options available: • Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AGIUG dome • Option 2: Aboveground option, coated with either powder coated TG IC polyester finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with steel AGIUG dome • Family & employee owned • Financing and leasing available • Customized delivery programs available HOW DO I FIND MY SALES REP? Visit our website, www.propanetank.com to view a list of our reps. Once on our site you'll be able to choose the Commercial options and from there you'll be taken to a list of US states where you can choose your location and view the contact information for your local sales rep. If you don't see your sales rep. please give us a call at 800-345-2495. Our manufacturing locations are strategically located to help serve your tank needs. OHIO LOCATION 721 Graham Drive Fremont, OH 43420 V9 UTAH LOCATION 5601 Axel Park Rd. West Jordan, UT 84081 801-280-1133 HOME OFFICE 2914 U.S. 61 Cleveland, MS 38732 800-345-2495 Consult our dimension and specification chart below to find the tank that best fits your needs. Visit our website at www.propanetank.com for more information. OVERALLLENGTH OVERALL HEIGHT LEG SPACING W. LEG WIDTH j % TLEG WIDTH APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG** SPACING WEIGHT (Ibs.) **QUANTITY FULLLOAD PERSTACK 120 wg. 2411 Ellip. 51-811 31 1 -1 1/2 or 3'-11" 260 108 196 16 112 *250 wg. 301' Hemi. 7'-1011 3'-8" 1'-511 4'-1111 480 54 9 *320 wg. 3011 Hemi. 9'-711 31-8" 1'-51' 51 620 45 9 500 wg. 37 1/2" Hemi. 10, 41-21' 1'-811 5' 950 37 30 8 6 1000 wg. 4111 Hemi. 16' 4'-5" 11-811 101-11, 1,800 17 15 6 5 E14w 46 1/2" Ellip. 17'-4" 4'-11" V-9" 11'-7" 2,650 4 w 46 1 2" Elli 23'-1111 4'-11" V-9" 16' 3 520 8 4 Dimensions and specifications shown are approximate. Individual vessels may vary * Leg spacing +I- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above. ** Full load and stack quantities vary by shipping location. Check with your salesperson for details. 490 QUALITY STEEL Because awlity steel means Quality Tanks * i31 M Yaa lal Sapgpntng VS0. Manal9C1jN,5 * HOME OFFICE 2914 U.S.61 Cleveland, MS 38732 800-345-2495 OHIO LOCATION 721 Graham Drive Fremont, OH 43420 419-334-2664 UTAH LOCATION 5601 Axel Park Rd. West Jordan, UT 84081 801-280-1133 Quality Steel 612017 S2 STORAGE TANK IS ADEQUATELY ANCHORED TO PREVENT FLOATATION, COLLAPSE OR LATERAL MOVEMENT DURING THE BASE FLOOD EVENT. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA 54-58, NATIONAL FUEL GAS CODE AND FLORIDA FUEL GAS CODE 2020 do FLORIDA BUILDING CODE 2020. TANKS INSTALLED IN TRAFFIC AREAS SHALL BE PROTECTED WITH GALV. STEEL SCHED. 80 PIPE BOLLARDS (efl) 6' LONG X 3' BURY DEPTH WITH CAP A 3' O.C. PROPANE TANK BUOYANCY MAX BUOYANCY = pr*g*Vtm* = 1.94 slug/ft' * 32.2 ft/s' * 66.84 ft' = 4176 LEIS NET BUOYANCY = MAX BUOYANCY - WEIGHT OF EMPTY TANK = 4176 LBS - 871 LEIS = 3305 LEIS FORCE ON J* CABLE = 3305 / 2 = 1653 LBS TENSILE STRENGTH OF J' CABLE = 9800 LBS / 5 = 1960 LE FORCE ON AUGER ANCHOR = 1653 / 2 = 827 LBS MIN. PULL-OUT RESISTANCE OF AUGER ANCHOR = 1360 LEIS -11 LP TANK i' 7x19 GALV. AIRCRAFT CABLE 2 TOTAL (IN POLY. SLEEVE) AUGER ANCHOR, 36- LONG W/ 6"0 HELIX 4 TOTAL SIDE ELEVATION SCALE 1/1' P-O" GRASS COVER I I I-IT�111=III=1 izi I 1=1 I 1=1 I 1= i (MAX COVER)1 LP TANK EXCAVATION SIZE:IL i�Z 12'Lx4rWx4.5'D 17LB. ANODE BAG — J' 709 GALV. Ferrellgas 3232 SE Dixie Hwy. Stuart, FL 34997 Fort Pierce Engineering, Inc. Dependable Mechanical. Electrical & Plumbing Design C_A- No 2817" 315 South 7th Street Fort Pi'ree, FL. 34950 Phone :772 672-4636 Fay'. 772 672-4617 a' Ho 60902 Eric J. Svoboda, PE P.E. No, 60982 AIRCRAFT CABLE STRAPPING BOLT AUGER ANCHOR, 36' Digitally,i--dby Eric S—boda W/ 6"4 HELIX 2.0500 m' eA batz versi6-1 on D.LONG Ado4e Acrobar version� 2020013,20074 FRONT ELEVATION SCALE 1/4" = 1'-O" 4SSUE DATE - DRAWN: EJS APPROVED: EJS DRAWING NUMBER T-1 LP500 NFPA 58-2017 and 2020 Editions Liquefied Petroleum Gas Code TiA Log No.: 1480 Reference: Table 16.1(n) Comment Closing Date: June 17, 2020 Submitter: Tom Dunn, Iowa Propane Gas Association www.nfl2a.org/58 1. Revise Table 16.1(n) to read as follows (highlighted to show corrections): n1 Polvethviene Plastic Pipe — Gas: Undiluted Propane Iniet Pressure.10.0 psig Pressure Drop: 1.0 psig _ Specific 1.52 Plastic Pipe i/z in. SDR 3/4 in- SDR I 1 in. SDR 11/4 in. SDR F1,n-SDR ii 2 SDR 11 Length 9.33 11 11 1I .554) (1in..943) . - INTE1riDED USE: Sizing .etween Firsk Stage Pressure Regulator and Se cond-Stage (Low -Pressure) 30 2140 23904290 774C 13420 20300 36400 40 1840 3670 6630 11480 17300 31200 5o 1630 3260 5870 10180 15400 27600 60 1470 2950 5320 9220 13900 25000 70 1360 2710 4900 8480 12800 23000 1260 2530 4560 7890 11900 80 21400 90 1180 2370 4270 7400 11200 20100 100 1120 2240 4040 6990 10600 19000 125 990 9901U0 3580 6200 9360 16800 150 897 8971,,._,B,QQ 3240 2980 5620 5170 8480 15200 14000 175 826 82-61M 7800 200 778 7481540 2780 4810 7260 13000 225 721 1AA4 2600 4510 6810 12200 250 681 68l13�4 2460 4260 6430 11600 275 646 64.61290 2340 4050 6110 11000 300 617 64771240 2230 3860 5830 10470 350 567 8641.,._.14,Q 2050 3550 5360 9640 400 528 5481060 1910 3300 4990 8970 450 495 49,5992 9' 1790 3100 4680 -_._,..__...,._, -- _ 8410 .. _,..-.,.., _,..,..,....._. 500 468 468 Z 93-71-60 -------- 2930 4420 7950 600 424 4-4849 8491530 2650 4010 7200 700 390 39g781 78_U!UQ 2440 3690 6620 800 363 a&3726 4261310 6821230 2270 2130 3430 6160 900 340 F49682 3220 5780 1000 322 -a2-2�4 64411fQ 2010 3040 5460 1500 258 2-58517 5}7 3 9nim 161 2440 4390 2000 221 24� 44-379B 4WIM 32090 3750 Copyright 2019 National Fire Protection Association (NfPAO). Licensed by agreement to Tom Fite FOR INDIVIDUAL USE ONLY and downloaded on 12/11/2019. No reproduction or transmission in any form permitted without written permission of NFPAR For inquiries or access for multiple users, or to report unauthorized use, contact IicensingQnfpe.org, PIPE AND TUBING SIZING TABLES 55-105 ©'fable 16.1(c) Schedule 40 Metallic Pipe Gas: I Undiluted Propane I Inlet Pressure:I I1.0 in. w c. Pressure Drop:1 0.5 in. wc. Specific Gravity:1 1.50 INTENDED USE: Pipe Sizing Between Single- or Second -Stage (Low -Pressure) Regulator and Appliance. Pipe Size (in.) Nominal: '/1 3/4 1 1'/, 1 1'/Y 1 2 2%2 3 4 Actual: 0.622 0.824 1.049 1.380 1 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Thousands of Btu per Hour 10 291 608 1,150 2,350 3,520 6,790 10,800 19,100 39,000 20 200 418 787 1,620 2,420 4,660 7,430 13,100 26,800 30 160 336 632 1,300 1,940 3,750 5,970 10,600 21,500 40 137 287 541 1,110 1,660 3,210 5,110 9,030 18,400 50 122 255 480 985 1,480 2,840 4,530 8,000 16,300 60 110 231 434 892 1,340 2,570 4,I00 7,250 14,800 80 101 212 400 821 1,230 2,370 3,770 6,670 13,600 100 94 197 372 763 1,140 2,200 3,510 6,210 12,700 125 89 185 349 716 1,070 2,070 3,290 5,820 11,900 150 84 175 330 677 1,010 1,950 3,110 5,500 11,200 175 74 155 292 600 899 1,730 2,760 4,880 9,950 200 67 140 265 543 814 1,570 2,500 4,420 9,010 250 62 129 243 500 749 1,440 2,300 4,060 8,290 300 58 120 227 465 697 1,340 2,140 3,780 7,710 350 51 107 201 412 618 1,190 1,900 3,550 6,840 400 46 97 182 373 560 1,080 1,720 3,040 6,190 450 42 89 167 344 515 991 1,580 2,790 5,700 500 40 83 156 320 479 922 1,470 2,600 5,300 550 37 78 146 300 449 865 1,380 2,440 4,970 600 35 73 138 283 424 817 1,300 2,300 4,700 650 33 70 131 269 403 776 1,240 2,190 4,460 700 32 66 125 257 385 741 1,180 2,090 4,260 750 30 64 120 246 368 709 1,130 2,000 4,080 800 29 61 115 236 354 681 1,090 1,920 3,920 850 28 59 ill 227 341 656 1,050 1,850 3,770 900 27 57 107 220 329 634 1,010 1,790 3,640 950 26 55 104 213 319 613 978 1,730 3,530 1,000 25 53 100 206 309 595 948 1,680 3,420 1,100 25 52 97 200 300 578 921 1,630 3,320 1,200 24 50 95 195 292 562 895 1,580 3,230 1,300 23 48 90 185 277 534 850 1,500 3,070 I,400 22 46 86 176 264 509 811 1,430 2,930 1,500 21 44 82 169 253 487 777 1,370 2,800 1,600 20 42 79 162 243 468 746 1,320 2,690 1,700 19 40 76 156 234 451 719 1,270 2,590 1,800 19 39 74 151 226 436 694 1,230 2,500 1,900 18 38 71 146 219 422 672 1,190 2,420 2,000 18 37 69 142 1 212 1 409 652 1,150 2,350 Note: All table entries are rounded to 3 significant digits. (54:Table 6.3.1(d) ] Shaded text = Revisions. A = Text deletions and figure/table revisions. • = Section deletions. N = New material. 2020 Edition Copyright 2019 National Fire Protection Association (NFPAN7j. Licensed by agreement to Tom Fite FOR INDIVIDUAL USE ONLY and downloaded on 1211112019- No reproduclien or transmission in any form permitted without written permission of NFPA®. For inquiries or access for multiple users, or to report unauthorized use, contact Iicensing@Wpa_org_ PIPE AND TUBING S12ING TABLES Table 16.1(k) Corrugated Stainless Steel Tubing (CSST) 58-113 Undiluted Gas: Propane Inlet Pressure: 11.0 in. w.c. Pressure Drop: 0.5 in. w.c. Specific Gravity: 1.50 INTENDED USE: CSST Sizing Between Single- or Second -Stage (Low -Pressure) Regulator and Appliance Shutoff Valve. Tube Size (EHD) Nominal ,Size: 9/8n s�g,r 11sn 11210 %ty 8/9n lit lr 11/1,11 1VI,r 111201 1,/2" 211 2r Flow Designation: 13 15 18 19 23 25 30 31 37 39 46 48 60 62 Length (ft) Capacity in Thousands of Btu per Hour 5 72 99 181 211 355 426 744 863 1,420 1,638 2,830 3,270 5,780 6,550 10 50 69 129 150 254 303 521 605 971 1,179 1,990 2,320 4,110 4,640 15 39 55 104 121 208 248 422 490 775 972 1,620 1,900 3,370 3,790 20 34 49 91 106 183 216 365 425 661 847 1,400 1,650 2,930 3,290 25 30 42 82 94 164 192 325 379 583 762 1,250 1,480 2,630 2,940 30 28 39 74 87 151 177 297 344 528 698 1,140 1,350 2,400 2,680 40 23 33 64 74 131 153 256 297 449 610 988 1,170 2,090 2,330 50 20 30 58 66 1 118 137 1 227 265 397 548 884 1,050 1,870 2,080 60 19 26 53 60 107 126 207 241 359 502 805 961 1,710 1,900 70 17 25 49 57 99 117 191 222 330 466 745 890 1,590 1,760 80 15 23 45 52 94 109 178 208 307 438 696 833 1,490 1,650 90 15 22 44 50 90 102 169 197 286 414 656 787 1,400 1,550 100 14 20 41 47 85 98 159 186 270 393 621 746 1,330 1,480 150 11 15 31 36 66 75 123 143 217 324 506 611 1,090 1,210 200 9 14 28 33 60 69 112 129 183 283 438 531 948 1,050 250 8 12 25 30 53 61 99 117 163 254 390 476 850 934 300 8 1 11 1 23 1 26 1 50 1 57 90 1 107 147 234 357 1 434 1 777 854 EHD: Equivalent hydraulic diameter. A measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing, Notes: (1) Table includes losses for four 90 degree bends and two end fittings. Tubing urns with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n, where L is additional length (IF0 of tubing and n is the number of additional fittings and/or bends. (2) All table entries are rounded to 3 significant digits. Shaded text = Revisions. 0 = Text deletions and figure/table revisions, 0 = Section deletions. N = New material. 2020 Edition Application Ideal for use as a first stage regulator on any domestic size ASME orb. DOT container in propane gas installations requiring up to 1,500,000 LISTED BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Features • Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. • Large threaded s/e' F.NPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. • Non Adjustable • Large flow orifice resists freeze ups due to water concentration in LPG vapor. • Design provides for good flow regulation at both high and low container pressures. • Built in relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates '/" F.NPT downstream pressure tap for an easy inline check of the regulator's delivery pressure. • Molded diaphragm provides an o-ring type seal between the body and bonnet. • Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system. • Fully painted in brilliant red for complete corrosion protection. • Mounting bracket available as an accessory: part number 2302-31, Materials Body............................................................................................Zinc Bonnet.........................................................................................Zinc Spring........................................................................................ Steel Seat Disc.................................................................Resilient Rubber Diaphragm...........................Integrated Fabric and Synthetic Rubber 0 J O Information 4_1 LV3403TR 3.56" ...... _ --- ------ FLOW PROPANE LV3403TR Over Outlet LV3403TRV9 Y.F.NPT '/_' F.NPT 7hz' 10 PSIG 9.00 1,500,000 Maximum flow based on inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 209klower than the regulator setting and delivery pressure 20 % lower than the setting. A14 MMM 100 RegO Dr. Eon. NC 272" USA wwwregoproducts.com +1 (336) 449-7707 Application Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11" w.c. Ideal for medium commercial installations, vapor meter installations and normal domestic loads. Features • 90 degree right angle inlet to outer connection for meter or standard installations. • Large vent helps to prevent blockage and has'/;' F. NPT for vent piping. • With 15 PSIG inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. • Replaceable valve orifice and valve seat. • Straight line valve closure reduces wear on seat disc • Unique bonnet vent profile minimizes vent freeze over when properly installed. • Large molded diaphragm is extra sensitive to pressure changes. • Built in pressure tap has plugged W F. NPT outlet. Plug can be removed with a 3/16" hex allen wrench. • Select Brown Finish Right Angle Design Can mount directly to vapor meter. It is also suitable for mounting directly to the house piping. It will retrofit into existing instaliations that are currently using a 90 degree, right angle regulator. Materials Body.......................................................................... Die Cast Zinc Bonnet........................................................................ Die Cast Zinc NozzleOrifice......................................................................... Brass Spring...................................................................................... Steel Valve Seat Disc ..................................................... Resilient Rubber Diaphragm ......................... Integrated Fabric and Synthetic Rubber Information UL C E 1 �m1 vot 4 N � L U C C-R �V I T, D V/I r 5'/<" +• � 0 LV4403B66RA s s 11" w.c. at 10 W4403B66RAB•• F. NPT /4 F. NPT 3/16" PSIG Inlet 9" to 13" W.C. Over Inlet w/ Mounting Bracket 1,000,000 ` Maximum Flow is based on 10 PSIG inlet and 9" w.c. delivery pressure. Mounting Bracket Included. 100 RagO Dr. Elon, NC 27244 USA www.regoproduCtS.com +1 (336) 449-7707 MEGM A21