HomeMy WebLinkAboutMAXIM PolySkylight 2019NOTICE OF ACCEPTANCE (NO
Maxim Industries, Inc.
1630 Terre Colony Court
Dallas, Texas 75212
MIAMI-]JADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.Eov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product
or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the High Velocity
Hurricane Zone of the Florida Building Code.
DESCRIPTION: Model RCM Curb Mount Skylight
APPROVAL DOCUMENT: Drawing No. 18-6912, titled "Model BCM Dade Curb Mount Skylight",
prepared by Engineering Express, dated September 28, 2018, sheet 1 and 2 of 2, signed and sealed by Frank L.
Bennardo, P.E., on November 12, 2018 bearing the Miami -Dade County Product Control Revision stamp with
the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the
following statement: "Miami -Dade County Product Control Approved or MDCPCA", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #17-0411.02 and consists of this page 1, evidence submitted page E-1 as well as
approval document mentioned above.
The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S.
MIAM4DADE 0 NOA No. 184120.08
. , Expiration Date: 08/03/2022
f 1 41to) Approval Date: 01/24/2019
Page 1
Maxim Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #17-0411.02
A. DRAWINGS
1. Drawing No. MS0217, titled "Model BMC Dade Curb Mount Skylight prepared by
Maxim Industries, Inc., dated 0211017, sheet I and 2 of 2, signed &sealed by
Theodore Berman, P.E.
B. TESTS
1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94; 2) Uniform Static Air
Pressure Test, Loading per FBC TAS 20244; 3) Water Resistance Test, per FBC, TAS
20244; 4) Large Missile Impact Test per FBC, TAS 201-94; 5) Cyclic Wind Pressure
Loading per FBC, TAS 20344 along with marked -up drawings and installation
diagram of Model BCM, prepared by Intertek /Architectural Testing, Test Report No.
G5934001-80148, dated 01103117, signed and sealed by Tyler Westerling, P.E.
C. CALCULATIONS
1. Anchor calculations, 7 sheets, issued by Ted Berman and Associates, LLC, dated
March 30, 2017, signed and sealed by Theodore Berman, P.E.
D. QUALITY ASSURANCE
1. Miami Dade County Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATION
I. None.
F. STATEMENTS
1, FBC, 2014 Edition, Compliance Letter issued by Ted Berman and Associates, LLC,
dated 03/30/17, signed & sealed by Theodore Berman, P.E.
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1, DWG. 418-6912, titled "Model BCMDade Curb Mount Skylight prepared by Engineering
Express, dated 09128118, 2 sheets, signed & sealed by Frank L. Bennardo, P.E., on 11112118.
Be TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami Dade County Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATION
1, None.
F. STATEMENTS
1. FBC, 2017 Edition, Compliance Letter issued by Engineering Express, dated
11/12118, signed & sealed by FrankL. Bennardo, P.E.
elmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No. 184120.08
Expiration Date: 08/03/2022
Approval Date: 01/24/2019
E-1
N
,,,
:=4
' ,A
.vwn�
-- ����
Design Pressure = +60psf/ -60psf I:
Model BCM `�� �'
^ � ���
(test pressure = +180psf/-120psf) �'�,� '��,�, �.��
�, .� " ° .
� ,� ¢� e..A..
m � #10 X .375" fastener � � � I I � �
Frame � o-- � -- (see Detail #1 & BOM #8)
Width = 72.5" (Maximum) w �
E
E
�X
f0
a�
v
m�
�
LL
N
�
II
m
C
J
0
II
C
.�
� /
SZ
O
/
J
�
/
DL Opening = 68.000"
4" from ea cornE
Max 6" O.C.
Notes:
1. This skylight is designed to comply with all requirements of the 6th edition of the
Florida Building Code (2017).
2. This skylight is designed to comply with all winds zones, including the HVHZ, of the
6th edition of the Florida Building Code (2017).
3. This skylight meets small &large missle impact resistance (TAS-201/ASTM E1886/ASTM E1996)
and no other protection is required.
4. This skylight complies with TAS 201, 202, 203
5. This skylights complies with AAMA/WDMA/CSA 101/I.S.2/A440 and AAMA 101
6. All sizes equal to or less than the test size total square footage are to be accepted
under this product approval; NOA, FBC#, TDI Report, UFC 4-010-01, and GSA-TS01-2003.
7. All framing, roof deck, flashing, and fasteners are by others and must comply with the
6th edition of the Florida Building Code (2017).
8. Fasteners used to attach skylight to wood curb are to be minimum #12 stainless
steel with minimum embedment of 1.25".
L
1
��
� a�
��
,� Z
in °�
��
X -
N ate-+
'—� N
�k p
c �
.
J�
-�
��
Corner Detail
(see Detail #1 & #4)
Installation Fastener
By Others (see note 8)
Frame Detail
(see Detail #1, #3 & #4)
Glazing Edge Detail
(see Detail #1 & #2)
Bill of Materials:
1. 6063-T5 Extruded Aluminum Frame mitered and welded at four corners.
2. 6063-T5 Extruded Aluminum Angle, 2" X 2", mitered and welded at four corners.
3. Covestro SL orPalRam UV Erihanced .118" Polycarboante dome.
4. Galling PoliCarb 5 Layer 16mm RDC Multiwall Polycarbonate.
5. Dow Corning 795 Silicone Building Sealant located between aluminum angle and outer dome.
6. ITW SM 5127 Sealant Tape located between 16mm RDC multiwall and extruded aluminum frame.
7. #10 X .375" Stainless steel fasteners 4" from each corner, maximum 6" on center.
8. #12 X 1.5" Stainless steel fasteners 4" from each corner, maximum 6" on center with minimum
embedment: of 1.25".
�"� IrI"' k _ yp gpg®6qg �p
�,
��� � > � ._ I. mew
L. BENNARDO, P.E.
.�
N
�j o�
„L 'x _t`W M n'U
�� ` ��'��
ZW� WWU�z
�>QLL�
(�a �¢woW
''''tt o � m �
WW pN��W
U�N�O
LL ;-; �
�Wn=
O W w
�o p
m
rn
u_
0
d
U
W .= F-
a � ��o=
� � �F�
��
a���
� � ���
� � ���
o � �����
$���>o
N m � � 2
�o
�, �s���
� � �� E�
���
COPYRIGHT ENGINEERING EXPRESS®
18-6912
SCALE:NTS UNLESS NOTED
OF
N
N
BENNARDO, P.E.
0046549
N
00
Detail #2: Glazing Detail
Covestro Makrolon SL® or
PalRam PalSun®
UV Enhanced
Polycarbonate.118"
Dome
Gallina USA PoliCarb® 5
Layer RDC Multiwall
Polycarbonate
ITW SM5127 Sealant
Tape; .625" X .50" or
Essentra VHB Acrylic
Tape; 1" X .090"
Detail #1:
Frame, Angle & Glazing Section Detail
Covestro Makrolon SL® or
III PalSun®
UV Enhanced
Polycarbonate .118"
Dome
Gallina USA PoliCarb® 5
Layer RDC Multiwall
0.630" / 16mm
Polycarbonate
OSI® Quad® Max
Sealant
Detail #3
Aluminum Shape Weld Detail
AFCO Part #AF-4950
Maintain weld height
weld acceptal
Location of heliarc welvi
Minimum .25" weep
hole located at each
corner.
i
1,1 EA
NoiD
r,
S
11cj Zrw.
`i
Dow Corning® 795 Silicone Building I
Sealant; 2" glazing bite.
ITW SM5127 Sealant Tape; .625" X .125"
085" 6063 T5 Extruded aluminum angle.
#10 X .375" stainless steel fastener.
6063 T5 Extruded aluminum frame.
Minimum #12 X 1.5" stainless steel
fastener with minimum 1.25"
embedment.
All framing, roof deck, flashing and curb
renderings are Tor testing and or rendering
purposes only and all components, other UJI
than the tested skylight specimen, are by CYM
others.
Detail #4
Aluminum Angle Weld Detail
AFCO Part #AF-4230
211 X 211
Location of heliarc weld
Z 0
cnO
GO
Um M X W #
O =
Lou C2
ez IL
F-
i<"WwQ
Z %a( a W W Z o
o.cm�ZZ�
aa+ W Ir
(IIW oNOLU MWIwv
� LL � .j
tAWaxW
oW w
�p
V
Z
h
J
z Z
V7 0 o
=Wg �
p W m
z �o
H M W
o
�~ o
x
a
cW
0
Y a a ��o
ZOUR
z 212 F
HE
COPYRIGHT ENGINEERING EXPRESS®
18- 5912
SCALE: NTS UNLESS NOTED