HomeMy WebLinkAboutEnergy CodeFORM R405-2017
.FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING'CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
WYNNE THE WINDSOR IMPACT BuilderName: WYNNE
ProjectName: DEVELOPMENT
Street: -'ss"S ,], S� ��V"'e S Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, PermitNumber:
Owner: Jurisdiction:
DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New
(From Plans)
9. Wall Types (1432.0 sqft.) Insulation Area
I
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2
b. Frame -Wood, Adjacent R=11.0 208:00 ft2
3. Number of units, if multiple family 1 i
c. N/A R= ft2
4. Number of Bedrooms 3
d. N/A R= ft2
10. Ceiling Types (1783.0 sqft.) Insulation Area
5. Is this a worst case? Yes
a. UnderAttic (Vented) R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. Knee Wall (Vented) R=19.0 30.00 ft2
Conditionedfloorarea belowgrade (ft2) 0
c. N/A R= ft2
11. Ducts R ft2
7. Windows(151.4 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 175
a. U-Factor: Sgl, U=1.04
111.36 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11
40.00 ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit 34.8 SEER:15.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems kBtu/hr - Efficiency
d. U-Factor: N/A
ft2
a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth:
2.850 ft.
Area Weighted Average SHGC:
0.285
14. Hotwatersystems
a. Electric Cap: 50gallons
8. Floor Types (1753.0 sqft.) Insulation
Area
EF: 0.970.970
a. Slab -On -Grade Edge Insulation R=0.0
1753.00 ft2
b. Conservation features
b. N/A R=
ft2
None
c. N/A R=
ft2
15. Credits Pstat
Glass/Floor Area: 0.086 Total
Proposed Modified Loads: 52.17 PASS
Total Baseline Loads: 53.92
I hereby that the specification
by
Review the
certify plans and
covered
of plans and
this calculation are in compliance with the Flor
da Energy
specifications covered by this
Code.
calculation indicates compliance
Code. '���, ��
with the Florida Energy r�pi •' �i
PREPAR€D 13Y.0
Before construction is completed
p
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, lis in compliance
Florida Statutes.
With the Florida Energy Co_tipy"
OWNER/AGQ4 •
BUILDING OFFICIAL:
DATE: �� %
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as.
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
4/21/202010:04 AM EnergyGauge® USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
ConditionedArea: 1753
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 0
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design DailyTemp
V DesignLocation
TMY Site
97.5%
2.5%
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
1753
14024
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO ,
224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63
504 No
0
1
No
Yes
Yes
3 MASTER BATH
56
448 No
0
1
Yes
Yes
Yes
4 M.BATH
61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180
I 1440 No
0'
1
1
Yes
Yes `
Yes
7 DINING/GREAT.RO
588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209
1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50
400 No
0
1
Yes
Yes
Yes
10 HALL
25
200 No
0
1
No
Yes
Yes
11 FOYER
92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3.
169
1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# FloorType
Space
Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1Slab-On-Grade Edge Insulation
MASTII
RBEDRO 37ft 0
224ft2
____
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
____
0 1
0
3Slab-On-Grade Edge Insulation
MAS�ERBATH
8ft 0
56ft2
____
0 1
0
4 Slab -On -Grade Edge Insulation
M.
BATH 7 ft 0
61 ftz
____
0 1
0
5Slab-On-Grade Edge Insulation
LAUDRY
1 ft 0
I
36ft2
____
0 1
0
4/21 /2020 10:04 AM
EnergyGaugew USA 6.0.02 (Rev.
I
I
1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType.
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
6Slab-On-Grade Edge Insulation
BEDROOM
12ft
0
180ft2
0 1
0
7Slab-On-Grade Edge Insulation
DINING/GREAT
50ft
0
588ft2
____
0 1
0
8Siab-On-Grade Edge Insulation
ITCHEN lift
0
209ft2
____
0 1
0
9 Slab -On -Grade Edge Insulation
BATH 5 ft
0
50 ft2
0 1
0
10SIab-On-Grade Edge Insulation
HALL 1 ft
0
25 ft2
____
0 1
0
11Slab-On-Grade Edge insulation
FOYER 9ft
0
92ft2
____
0 1
0
12SIab-On-Grade Edge Insulation
BEDROOM
3 14 ft
0
169 ft2
____
0 1
0
ROOF
/
Roof
Gable
Roof.
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials
Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal
1847 ft2
0 ft2
Light
N
0.4
No 0.9
No 0
18.4
ATTIC
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# CeilingType
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 UnderAttic(Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 UnderAttic(Vented)
WIC
30
Blown
63ft2
0.1
Wood
3 UnderAttic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 UnderAttic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 UndeMitic(Vented)
LAUDRY
30
Blown
36ft2
0.1
Wood
6 UnderAttic (Vented)
BEDROOM 2
30
Blown
180"ft2
0.1
Wood
7 UnderAttic(Vented)
DINING/GREAT
30
Blown
588ft2
0.1
Wood
8 UnderAttic(Vented)
KITCHEN
30
Blown
209ft2
0.1
Wood
9 UnderAttic(Vented)
BATH
30
Blown
50ft2
0.1
Wood
10 UnderAttic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 UnderAttic(Vented)
FOYER
30
Blown
92ft2
0.1
Wood
12 UnderAttic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
D INING/GREAT
19
Blown
30 ft2
'0.11
Wood
WALLS
Adjacent
C)Mt To Vv:all Type
Space Cavity Width
Height
Sheathing Framing Solar Belo w
1
E Exterior Concrete Block - Int InsuMASTER
BE 4.1 16
0 8
0
128.0 ft2
0
0 0.3
0
_
_ 2
W Exterior Concrete Block-
Int InsuMASTER
BE 4.1
7
0 8
0
56.0 ft2
0
0 0.3
0
3
S Exterior Concrete Block - Int InsuMASTER
BE 4.1 14
I-
0 8
0
112.0 ft2
0
0 0.3
0
4/21/2020 10:04 AM
EnergyGaugeO USA 6.0.02 (Rev
1)-FlaRes2017FBC6th Edition (2017) Compliant Software . Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent I Space
Cavity Width
Height
Sheathing Framing
Solar Below
4
E
Exterior
Concrete Block- Int InsuMASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_ 5
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
_ 6
E
Exterior
Concrete Block - Int II1suBEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
_ 7
S
Exterior
Concrete Block- Int I suDINING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
_ 8
W
Exterior
Concrete Block- Int InsuDINING/GRE
4.1 20
0
8 0
160.0 ft'
0
0
0.3
0
_ 9
W
Exterior
Concrete Block- Int In' sul KITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
10
E
Exterior
Concrete Block- Int I sul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
_
11
N
Exterior
Concrete Block- Int Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_
,
_12
N
Exterior
Concrete Block- Int Inl sul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13
W
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
15
N
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Ornt
DoorType
Space
Storms
U-Value
Width
Height
Area
Ft
in
Ft in
1
N.
Insulated
FOYER
None
.32
3
3
6 8
21.7 ft2
{
WINDOWS
Orientation
shown is the entered orientation => chan ed to Worst Case.
V
Wall
Overhang
#
Ornt ID
Frame Panes
NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
S 3
Metal Low-ESingle
Yes
1.04 0.29
N
32.4 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
2
E 5
Metal Low-ESingle
Yes
1.04 0.29
N
6.9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low-ESingle
Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-ESingle
Yes
1.04 0.29
N
39.8 ft2
1 ft0 in
1 ft 5 in
None
None
5
W 8
Metal Low-ESingle
Yes
1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-ESingle
Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
GARAGE
#
FloorArea CeilingArea
Exposed Wall Perimeter
Avg. Wail Height
Exposed Wall insulation
1
806 ft2 " 806I
ft?
i
26 ft
8 ft
11,
INFILTRATION
# Scope
Method iSLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000254 1168.7 64.16
120.66
.0881
5
4/21/2020 10:04 AM
EnergyGauge® USA 6.0.02 (Rev.
1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
I
1=0RM PAW;_9n17 INPI ITRI IMMARY rHFCKI IST RFPCART
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
i
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 15
34.8 kBtu/hr cfm 0.85 1
sys#1
I
HOT WATER SYSTEM
# . System Type
SubType
jLocation
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
--- Supply---
---- Return ---- .
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 175 ft2
Attic
55 ft2 DefaultLeakage
Attic
(Default) c(DefauIt) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating Jan HFeb
HJan
Mar
Mar
i
Apr
E; Apr
May Jun Jul
I May Jun Jul
Aug
Aug
Sep
SePOctNov
Oct Nov
Dec
Deci
Ventin Feb
X Mar
[xl Apr
may Jun Jul
Aug
Se
[X] Oct X Nov
Dec,
ThermostatSchedule: HERS 2006
Reference
Hours
ScheduleType
1
2 III 3
4 5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 78
78 78 78
78
78
78 78 78
78
Cooling(WEH) AM
78
78 Ili 78
78 78 78
78
78
78 78 78
78
PM
78
78 78
78 78 78
78
78
78 78 78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 1 68
68 68 68
68
68
68 68 66
66
Heating(WEH) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68,
68 68
68 68 68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
Q ft2
0 ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
Ift2
ft
0.3
WIC
Default(8Ibs/sq.ft.
Ift2
ft
0.3
MASTER BATH
Default(8lbs/sq.ft.,
ft2
ft
0.3
M. BATH
Def6ult(81bs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8lbs/sq.ft.
Ift2
ft
0.3
BEDROOM 2
Default(81bs/sq.ft.
Ift2
ft
0.3
DINING/GREAT RO
Default(8lbs/sq.ft.
Ift2
ft
0.3
KITCHEN
I
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORn R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
kea Thickness FumitureFraction
Space
Default(8lbs/sq.ft. V
Default(8lbs/sq.ft.
Default(8lbs/sq.ft.
Default 8lbs/s .ft.
ft2 ft 0.3
ft2 ft 0.3
ft2 ft 0.3
ft2 ft 0.3
BATH
HALL
FOYER
BEDROOM.3
I
4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software
I
Page 6 of 6
i
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I
Project Name: WYNNE THE WINDSORIIMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
2
2
Design Location: FL, Fort Pierce
y
COMPONENT
AIR (BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A. continuous. air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air, barrier shall be sealed.
not be used as a sealing material.
The air barrier in any dropped ceiling/soffit shall be aligned with
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
The insulation in an dropped ceiling /soffit
y PP g
shall -be aligned with the air barrier.
Access openings, drop down stairs.or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with: the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the
air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed
at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to, fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed: atlexteriorwails adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers, and tubs.
be insulated.
ElectricaVphone box or
The air barrier shall be installed behind electrical or communication
exterior walls '
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is{recommended by the manufacturer.
Caulking or other adhesive sealants shall - not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/21/2020 10:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
v
2017 EPL DISPLAY CARD
ENERGY. PERFORMANCE LEVEL (EPL) DISPLAY.CARD
i
ESTIMATED ENERGY PERFORMANCE INDEX* = 9.7
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
2. Single-family or multiple -family
3. No. of units (if multiple -family)
4. Number of bedrooms
5. Is this a worst case? (yes/no)
6. Conditioned floor area (sq. ft.)
7: Windows, type and area
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
c) Area
8. Skylights
a) U-factor.(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
.A. Exterior:
1. Wood.frame (Insulation R-value)
2. Masonry.(Insulation R-value)
B. Adjacent:
1. Wood frame (insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family
b) Return ducts .. R
6.0
c) AHU location
Attic
3.
1
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5.
Yes
b) Single package SEER
c) Ground/water source SEERICOP
6.
1753
d) Room unit/PTAC EER
e) Other
7a.
1.058.
7b.
0.285
14. Heating system: Capacity
34.8
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
c) Electric resistance COP
8a.
NA
d) Gas furnace, natural gas AFUE
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9a.
0.0
9b.
15. Water heating system
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF.
d) Solar system with tank EF
10A1.
e) Dedicated heat pump with tank EF
10A2.
4.1
f) Heat recovery unit HeatRec%
g) Other
10131.
11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a.
30.0
b) Cross ventilation
No
11 b.
c) Whole house fan
No
11c.
19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded): in this home before .final inspection. Otherwise, a new EPL
display card will be completed based'on installed code compliant features.
Builder Signature:.
Address -of New Homer J
�� City/FL Zip: FT. PIERCE, FL -�-tr1.5 `
4/21/202010:05:25 AM EnergyGaugell USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1