Loading...
HomeMy WebLinkAboutProduct Approval- Windows Florida Building Code Online https:Hfloridabuilding.org(pr/pr app_dtl.aspx?par&.. 2 a ar if nS�f P4 FA O�T's�.. 4`�%i.S` MP BCISHone Logln User Registration Hot ToplS ' Submt Surcharge 4 Stals&Facts i Pub@alions j Contact Us ' l30SSite Map Lhks Search db . r Product Approval ( USER:Pubic User P rod cl Arurova I M enu>P rodret a?Aigticalinn Se.arch>Agpicat In L K t>Application De tall r N mow; *s.y, ? 01 FL# FL14090-R12 >iaf Jxl r`4: Application Type Revision Code Verson 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived RECEIVED Product Manufacturer JELD-WEN pp� 7n71 AddresstPhone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 Permitting Department fbcl@jeld-wen.com St. Lucie County Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Window Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By 1 of 3 4/7/21, 10:51 Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?pwa.. Product Approval Method Method 1 Option A Date Submitted 11/18/2020 Date Validated 11/19/2020 Daze Pending FBC Approval Date Approved 11/24/2020 Summary of Products FL# Model,Number or Name Description 14090.1 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(3/16 in-3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_N1011635-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/31/2025 Design Pressure:+50/-55 Installation Instructions Other:Windowswith insulated glassunitswider than PL14090_R12_II_DP50-55 74x62_Installation_Instructionspdf 36"require setting blocks Laminated glazing interlayer Verified By:HermesNorero,PE 73778 material requirements meet the current edition of the Created by Independent Third Party:Yes FBC in accordance with Miami-Dade NOA for DuPont Evaluation Reports SentryGlas and DuPont PVB interlayers. PL14090 R12_AE_PER3105.pdf Created by Independent Third Party:Yes 14090.2 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(3/16 in-3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes PL14090_R12_C_CAC_N1011636-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/31/2025 Design Pressure:+65/-70 Installation Instructions Other:Windowswith insulated glass unitswider than FL14090 R1211DP65-7 _Zjx 4_Installation_Instructionspr�f 36"require setting blocks Laminated glazing interlayer Verified By:HermesNorero,PE 73778 material requirements meet the current edition of the Created by Independent Third Party:Yes FBC in accordance with Miami-Dade NOA for DuPont Evaluation Reports SentryGlas and DuPont PVB interlayers. FL14090 R12_AE PER3102.pdf Created by Independent Third Party:Yes 14090.3 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 SGP Lam in 3/16 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_N1011681-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/30/2025 Design Pressure:+50/-55 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090 R12_II_DP50-55 LMI 74x62_Install ation_Instructionspdf setting blocks Thesewindowsdo not meet small missile Verified By:Hermes Norero 73778 impact wind-borne requirements of the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite is annealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090 R12 AE PER3103.pdf when the exterior lite istempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordancew/Miami-Dade NOA for DuPont SentryGlas and DuPont PVB interlayers 14090.4 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(5116 PVB Lam in 1/8 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_NI011745-Ri.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 10/31/2025 Design Pressure:+50/-55 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090_R12_II_DP50-55 74x54_LMI_Installation_Instructionspdff setting blocks These windows do not meet small missile Verified By:HermesNorero,PE 73778 impact wind-borne requirements of the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite is annealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090_g12_AE_PER_3101.pdf when the exterior lite istempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordance w/Miami-Dade NOA for DuPont SentryGlas and DuPont PVB interlayers 14090.5 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(5/16 SGP Lam in 118 Annealed out) 2 of 3 4/7/21, 10:51 Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?para.. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_N1011682-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/30/2025 Design Pressure:+60/-65 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090_R12_II_DP60-65_LMI 74x54_Installation_Instructionspdf setting blocks Thesewindowsdo not meet small missile Verified By:Hermes Norero,PE 73778 impact wind-borne requirementsof the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite isannealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090 R12_AE_PER3104.pdf when the exterior lite istempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordance w/Miami-Dade NOA for DuPont DuPont PVB interlayers (Z14090.6 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 PVB Lam in 3/16 Annealed out) se Certification Agency Certificate d for use in HVHZ:Yes FL14090_R12_C_CAC_N1011745.01-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2025 Design Pressure:+50/-50 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090 R12 II DP50_74x62 LMI_Installation_Instructionsodf setting blocks.These windows do not meet small missile Verified By:Hermes Norero 73778 impact wind-borne requirements of the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite is annealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090 R12_AE PER2692.pdf when the exterior lite istempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordancew/Miami-Dade NOA for DuPont SentryGlas and DuPont PVB interlayers 14090.7 Premium Atlantic Vinyl Horizontal Slider(8200)111"x 54"Insulated Glass(5/16 PVB/SGP Lam in-3/16 Tempered out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090 R12_C_CAC_N1013719-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2025 Design Pressure:+50/-55 Installation Instructions Other:These windows meet small missile impact wind- FL14090_R12_II_PAV XOX Installs.pdf borne protection requirements as required by FBC, Verified By:Joseph A.Reed 58920 section 2411.3.3.7 when the exterior lite istempered. Created by Independent Third Party:Yes Laminated glazing interlayer material requirements meet Evaluation Reports the current edition of the FBC in accordance with Miami- FL14090_R12_AE_22068-1.pdf Dade NOA for DuPont SentryGlas and DuPont PVB Created by Independent Third Party:Yes interlayers Back Next Contact Us::2601 Bbi Stone Road,Ta lahas s e e FL 32399 Phone:850-487-1824 The Stale of Florida is an AAIE E O e rtpbye r.Copy_tht 2007-2013 State of Florida.::PP Nacy.State nent::Acce s s bk.stalere nt::Refund state went Under Florida law,erat addresses are pubic records.It you do not wantyour a-rral address released h response to a pubic-records requesL do not send electronic rrai to this entity.Instead,contact the office by phone or by tradamral rral If you have any questions.please contact 850.487.2395.-Pursuant to section 455.275(1),Florida statutes, effective October 1,2012.I ce ns a es ice ns ed unde r Chapte r 455,F.S.rust provide the Department with an e nai address i they have one.The ends provided nay be used for official contrunication with the ice ns a e.However era i addresses are pubic record.If you do not wish to s upply a personal address,please provide the De partite nt win an enni address which can be rade available to the pubic.To deterrme If you area icens ee underChapter455.F.S.,please click here. Product Approval Accepts: am® R Credit Card Safe 3 of 3 4/7/21, 10:51 NOTICE OF PRODUCT CERTIFICATION )yT 0 CERTIFICATION NO: NI011745.01-R1 '� ar DATE: 12/20/2013 CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN ` CODE: 1822-1 REVISION DATE: 06/10/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertitication.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl" 3737 Lakeport Boulevard Horizontal Slider 8200 Window (Impact) Klamath Falls,OR 97601 Configuration: XO Glazing:IG-3/16"Annealed Glass/1-aminatc-1/8" Annealed Glass/0.090"DuPont PVB Interlayer/11'8" Annealed Glass Frame: W-1879tnm(74.00") 1-1-1574mm(62.00") Vent: W-939mm(37.00") 1I-1504mm(59 25") DLO: W-854rnm(33.62") II-1485nun(58.50") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psf) Negative Design Pressure:2394 Pa(50 pst) Large Missile Impact Rated Product 'Tested By: National Certified Testing Laboratories Report No: NCTL-210-3894-01 Expiration Date: November 30, 2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124/ Fax: (804) 684-5122 NAIL FIN INSTALLATION t!7"MIN.EMBEDMENT 1W"O.C. 4.0 ow t 2 2X WOOD FRAME t MAIL mu F71 rpm COS 1 MIN DISTANCE MIN.DISTANCE i � !`� FOR EDGE.3!a^ FOR EDGE.3!4" f3 ,i 2X WOOD 3 1J4"MAX i SHIM SPACE FRAME FIX i j 22.0 mm 2 1/4"MAX I 1 2 0 mm SHIM SPACE 50 mm�30 mm ;1 ii 1 1/2"MIN. EMBEDMENT 1 6I30S BITE mm DOW 995 }Q,a�ING D AiL 1 FRAME SECTION(TYP) I VERTICAL SECTION JAMB SECTION(TYP) ���" ti,.•,•� ,F,,,d "•�<.� li HORIZONTAL SECTION !01E C-Nb. -•h.Rnq fkJg 4 Wcod OP-19 iL= I _11�I 1/4•MAX I 5HIM SPACE 3 ..1.__...___.....'___.._.,._._-_._.._._„._:_____.___._._...,..._..--__.-- MITI.DISTANCE FOR EDGE:3/4" t I '"'DIV°"'"°'"`"+"""' (I s 2X WOOD FRAME Max Frame I DP RATING IMPACT TYPICAL ELEVATION WITH FASTENER SPACING i1 EMBEDMENT i 74 x 62 +50/-50 YES Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind to criteria 2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida 112"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5 mm annealed 19 mm airspace 13 mm annealed 12 mm PVB by project of installation, Dupont 13 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the ,t`t t t t tl building code. window to achieve the rated design pressure up to the size limitations 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE: 3737 Lakeport Blvd not address the sealingconsideration that may arise in different wall `♦�Q`` •• ' ••t�,A -- 01/30/2014 � EN Y ♦ JE Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions . .Z �, . DRAWN BY: SCALE: • i ► D.Veto NTS Phone: (541)$82-3451 packaged with the window or go to : 7 .- CHECKED BY: TITLE: www.jeld-wen.comlresourceslinstallatian. _ �k �- * J. Kantola APPROVEDBY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: 4U -' Nail Fin Installation (74"x 62") This drawing and its contents are confidential and are not to be 0 •••.�� D4` ��� PART+PRO 64 o.• reproduced or copied in whole or in part or used or disclosed to others �i� '�i► 0. a ♦♦ D0096 except as authorized by JELD-WEN Inc. s9e at. 338 INCT L210-3894- PLANT NAME AND LccAnoN: cAD DWG.N".: REv: st+err trfa THROUGH FRAME + MIN.DISTANCE INSTALLATION I FOR EDGE 314" 3 1=11,O.C. 6A'W11G WVL f11AY[ C010iF5 1 2 1 W"MIN. y EMBEDMENT' 1 1/2•MIN. EMBEDMENT 1/4"MAX 1/4"MAX 1T 0.0 I I t SHIM SPACE SHIM SPACE 3 ntAIM 22.0 mm 20rnm ;j n i 5.0 mm 3,0 mm I ! MIN,DISTANCE 'Z FOR EDGE 3/4 ---------- ' i GLASS BITE ' Dow 995 1 l+, f 61A�ING DETA11. �, JAMB SECTION(lYP) j HORIZONTAL SECTION i FRAME SECTION TYP it i VERTICAL SECTION { va•Max MS CE 1 _ 3 ,*WW WMM a.•WA0— ; 2 11/Z"MIN, TYPICAL ELEVATION WITH FASTENER SPACING I EMBEDMENT ( Max Frame I OP RATING IMPA j MIN.DISTANCE i! 74 x 62 +50/-50 YES FOR EDGE'3/4" Installation Notes: General Notes: 1. Seal flangetframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 1 112" of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5 mm annealed 19 mm airspace 13 mm annealed 12 mm PVB by project of installation. Dupont 13 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations 0—1l t 111►I ".*/ 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �� %, PROIECT ENGINEER: DATE,. 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall ��`��` •. C� ��� -- 02/03/2014 conditions. For the complete installation procedure,see the instructions :' •';!�� i DRAWN BY: SCALE: L Klamath Falls,OR,97601 rWN D.VE!zo NTS. Phone: (541)882-3451 packaged with the window or go to 7 CHECKED BY: TITLE. www.jeld-wen.com/(esourcesAns(allafon. J. Kantola -o T T Q = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: ':•! A ! Through Frame Installation (74"x 62") This drawing and its contents are confidential and are not to be •.�� DP �� PDT1P�ojE �o reproduced or copied in whole or in part or used or disclosed to others ��� ��tt.��eecc o>��e �� BUT (�3`t� (� except as authorized by JELD-WEN Inc. 39e a 1€t. ° 938 IDENTIFIER N1 1 L210-3B74- PLANTTCNAME AND 1UC1770N: CAD D1VG No.: REV' SHEET OF 4 �I MIN.DISTANCE MASONRY INSTALLATION FOP FesE 2 1r2" d MA5r7NRY ti 1UM i�i W a rNM I i 2 1 AQS p . t 1/0"MIN. 1 � d 3 EMBFDMENT d �1 1 i j 13ra"MIN EMBEDMENT 1 I !) U4"MAX lY 0C i 3Mz.noel ( 114"MAX 3 SHIM SPACE FFAME !( 1 SHIM."TRACE i ' MIN DISTANCE FOR EO&E•2 1/2" V, _° I j I{{ N 22 0 run •--� j i 2 C mm 7""7 f 50my,�-3.0 I ;I L... •a. SI13.0 !I ASS SM MASCNRv it BLOCK t DOW 9" i C1AZIrG a An i JAMB SECTION(TYP) HORIZONTAL SECTION FRAME SECTION(TYP) i I VERTICAL SECTION ;) ` 1/4•MAx —OT T `� SHIM SPACE — ! t a�MIN""'°01"'ATM('0"'�) 4 2JEL M t/BEDMENT ! Max Frame DP RATING IMPACT TYPICAL ELEVATION WITH FASTENER SPACING I 3i a A SO Y � 74 x 62 +50/-50 YE5 ' MIN,bISTANC'E tl General Notes: � and manufactured to complywith the wind toad criteria FOP Eb6Er z 1/r Installation Notes: 1• The product shown herein is designed,tested a of 1. Seal flange/frame to substrate. of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida 2. Use 3116"Tapeon or equivalent fasteners through frame with sufficient length to penetrate a minimum Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. of 1 1/4"into concrete or masonry at each location with a 21/2"min from edge distance.For concrete 2 Ali glazing shall conform to ASTM E1300. (min.fc=3000psf)or masonry substrate(CMU shall adhere to ASTM C90). 3. At minimum,glazing shall be 5 mm annealed 19 mm airspace 13 mm annealed 12 mm PVB by 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads Dupont 13 mm annealed. to the structure. The host structure is the responsibility of the architect or engineer of record for the 4• Use structural or composite shims where required. project of installation. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the ,,,1t t t t , building code. window to achieve the rated design pressure up to the size limitations �� I� 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �� �� PROIECr ENGINEER: DATE: JELDWEN 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall ����Q1` • •• • ,•�,A ��� -' 01/30/2014 Klamath Falls,DR.97601 conditions. For the complete installation procedure,see the instructions Z �, DRAWN BY: SCALE: packaged with the window or go to D.Vezo NTS Phone: (541)882 3451 7,. . . CHECKED BY: TITLE: www.jeld-wen.com/resourcestinstallation. �Mr _ ). Kantota -a T T cr APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: = <u -- t� This drawing and its contents are confidential and are not to be . •'•. OP �� PART P 0•E Na Masonry Installation(74 x 62 ) reproduced or copied in whole or in part or used or disclosed to others �.1 °i N D60§346 except as authorized by JELD-WEN Inc. 398 a ° 93e �NCTL210-3894- PF`CNAME AND!OG1T1pN: CAD DWG NO.: REV' SHEET 3 nF A `II STEEL INSTALLATION ! MIN DISTANCE + rr"REVE 112' . . i t�y�C MAX. I} .I Min.embedment j �I of three threads i! 3 COMM Post frame �• j i Id gauge mm ''. L8 gouge.mm i -il 1 I Steel stud Steel Stud t I/4"MAX 1/4"MAX 17. C. SHIM SPACE is SHIM SPACE MAIL WIN) lr FRAIL I i MIN DISTANCE zz 0 mm FOR EDGE.1/2" 2 i 2.D mm II I ---•-^-'3 I l y ! i Min.embedttlent 1 L of three threads 3 i GL13 mm BITE {� past frame i i! I DOW 995 l� ' GLAZING DETAIL 1 JAMB SECTION(TYP) l I FRAME SECTION(TYP) I HORIZONTAL SECTION VERTICAL SECTION i I/4"MAX i �T T SHIM SPACE 16 gauge min Steel Stud rn+oow Arta p0 ' I Mlm embedment 1 Max Frame I OP RATING IMPACT TYPICAL ELEVATION WITH FASTENER SPACING of three threads i Past frame I 74 x 62 +50/-50 YES MIN.DISTANCE !I FOR EDGE:1/2, Ji Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use#10 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum embedment of three threads past the Frame thickness. Steel substrate min.l8ga.,fy=33 ksi. Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 2 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads . All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5 mm annealed 19 mm airspace/3 mm annealed 12 mm PVB by project of installation. Dupont 13 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the �1t y t I t building code. I window to achieve the rated design pressure up to the size limitations Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does .%- PROTECT ENGINEER: DAIS: JELD � 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall ���SQL' "� " • ••t� ��� -- 01/30/2014 p° conditions. For the complete installation procedure,see the instructions Z ; ��,�� DRAWN BY: SCALE: Klamath Falls,OR,97601 D.VeZo NTS Phone: (541)882-3451 packaged with the window or go to 7 CHECKED BY: TITLE: www_ield-wen.com/resources/installation. J, Kantola T T Z APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: �O ,!,� P; �U✓ Steel Installation (74"x 62") This drawing and its contents are confidential and are not to be O �. P T P O E No reproduced or copied in whole or in part or used or disclosed to others 0 °� COCA except as authorized by JELD-WEN Inc. See �4Qh tt 938 IDENTIFIER Nb, PLANT NAME AND LOCATION: CAD DWG No.: REV: SHEET 4 OF 4 ovawtLpj NCTL210-3894- -FBC