Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY iEFFICIENCY CODE _FOR BUILDING CONSTRUCTION Florida `Department of Business and Professional Regulation - Residential Performance Method ProjectName: GEMINI� C Street: v� BuilderName: WYNNE BUILDING CORP. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: ' Owner: Jurisdiction: DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New.(FromPlans), 10. WallTypes(17.63.8 sqft.) Insulation Area 2. Single family or multiple family Detached a: Concrete Block- Int Insul, Exterior R=4.1 1507.80 ft2 3. "Number of units, if multiple family 1 b. Frame- Wood, Adjacent c. N/A R=11.0 256.00 ft2 ' R= ft2 4. NumberofBedrooms 2 d.N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types " (1839.0 sqft. ) Insulation . Area a: UnderAttic (Vented) R=30.0 1839.00 ft2 6. Conditioned floorarea above grade (ftz) 1839 b. N/A _ R= ft2 Conditioned floorareabelowgrade(ftz) 0 c. N/A R= ft2 7. Windows(155.3 sqft.) . " Description Area 12. Ducts R ft2 a. U=Factor: Sgt, U=1.02 115.28 ft2 a. Sup: Attic,'Ret: Attic,'AH: Attic 6 125 SHGC: SHGC'--0.27 b. U•Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr " Efficiency SHGC: 'SHGC=0.27 a. Central Unit 34.8 SEER:15.00 .c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.318 ft. 14.Heating.systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.270 A. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-FactOr:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric' Cap:40 gallons 9. Floor Types (1839.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1839.00ft2 b. Conservation features b: N/A R= ft2 None c. N/A R.= ft2 16..Credits : Pstat . Glass/Floor Area: 0.084 Total Proposed, Modified Loads: 51.52 PASS Total Baseline Loads: 52.96 I hereby certify that the plans and specifications covered by . Review of the plans and this calculation are incompliance with the Florida Energy specifications covered. by this C! Code. "calculation indicates. compliance y;�y with the Florida Energy Code. PREPAR9[ Y. Before construction la completed" _ DATE: L O this building will be' inspected for S compliance with Section 553.908 1 hereby certify. that this:buiiding, as designed, is' in compliance Florida Statutes. with the Florida Energy Code.C'�,� OWNER/AQ1R : BUILDING OFFICIAL: DATE. ` DATE: - "Compliance requires certification by the air handier unit manufacturerthat the air handler enclosure qualifies as certified factory -sealed" in accordance with R403.3.2.1. ' Compliance requires an Air Barrier'and Insulation Inspection Checklist in accordance -with 11402.4.1A and this""project requires an envelope leakage test report with envelope leakage. no greater. than 5.00 ACH50. (R402.4.1.2). REVIEWED F0h, 30CE CO PL1Aic 12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Editiq§120)�C � # ftyrar� Page 1 of 6 e FORM R405-2020 INPUT RI IMMARY f_I41:rV1-ICT 1011=113nQT PROJECT 'title: GEMINI Bedrooms: 2 Address Type: StreetAddress Building Type: User ConditionedArea: 1839 Lot# OwnerName: Total Stories: 1 Block/Subdivisiori: #'of Units: 1 Worst Case: Yes PlatBook: BuilderName: WYNNE BUILDING CORP. RotateAngle: 270 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp DesignLooation TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 tow BLOCKS Number Name Area Volume 1 Entire House 1839 14712 SPACES .Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 MASTER BEDROO 256 2048 No 0 1 1 Yes Yes Yes 6 ENTRY 83664 No. 0 1 Yes Yes Yes 7 LAUNDRY 42 336 No 0 1 Yes Yes Yes 8 GREAT/DINING 568 4544 No 0 1 Yes Yes Yes 9 CLOSET 2 56 448 No 0 1. No Yes Yes 10 BATH 2 48 384 No 0 1 Yes Yes Yes 11 POWDER 42 336 No 0 1 No Yes Yes 12 SITTING ROOM 110. 880. No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 43 ft 0 343 ftz ____ 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 63ft2 ____ 0 1 0. 3 Slab-On-GradeEdgelnsulation - M.BATH 8ft 0 56ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 172 ft2 ____ 0 1 0 5Slab-On-Grade Edge Insulation MASTER BEDRO 51 ft 0 256 ft' ____ 0 1 0 12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area . JoistR-Value Tile Wood Carpet 6 Slab-On-GradeEdge Insulation ENTRY 7 ft 0 83 ft2 ____ 0 1 0 7Slab-On-GradeEdge Insulation LAUNDRY 6ft 0 42ft2 ____ 0 1 0 8Slab-On-GradeEdge Insulation ' GREAT/DINING 39 ft 0 568 ft2 ____ 0 1 0 9 Slab-On-GradeEdgelnsulation CLOSET 2 1 ft 0 56 ft2 ____ 0 1 0 10Slab-On=GradeEdgeInsulation BATH 2 8 ft 0 48 ft2 ____ 0 q 0. 11SIab-On-GradeEdge Insulation POWDER 1 ft 0 42ft2 -___ 0 1 0 12SIab-On-GradeEdgelnsulation SITTING ROOM 22ft. 0 110ft2 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1938 ft2. 0 ft2 Light N 0.6 No 0:7 No 0 18.43 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1839 ft2 N N CEILING. # CeilingType Space R-Value Ins Type Area FramingFrac Truss Type . 1 Under Attic (Vented) BEDROOM 30 Blown 343ft2 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63ft2 0.1 Wood 3 UnderAttic(Vented) M. BATH. `30 Blown 56 ft2 0.1 Wood 4 UnderAttic(Vented) KITCHEN 30 Blown 172ft2 0.1 Wood 5. Under Attic (Vented) MASTER BEDRO 30 Blown 256 ft2 0.1 Wood 6 UnderAttic(Vented) ENTRY 30' Blown 83ft2 0.1 Wood 7 UnderAttic(Vented) LAUNDRY 30 Blown 42ft2 0.1 Wood 8 UnderAttid(Vented) GREAT/DINING 30 Blown 568ft2 0.1 Wood' 9 UnderAtfic (Vented) CLOSET 2 30 Blown 56 ft2 0.1 Wood 10 UnderAttic (Vented) BATH 2 30 Blown 48 ft2 0.1 Wood 11 UnderAttic(Vented) POWDER 30 Blown 42ft2 0.1 Wood 12 UnderAttic(Vented) SITTING ROOM 30 Blown 110ft2 0.1 Wood WALLS 9Cavity Adjacent Width Space . Height Area Sheathing: Framing . Solar Below . Ahsor o 1 S=>E . Exterior Concrete Block- Int Insul BEDROOM 4.1 29 0 8 0• 232.0 ft2. 0 0. 0.4 0 2 W=>S Exterior Concrete Block - Int Insul BEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 3 S=>E Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 4 N=>W Exterior Concrete Block - Int Insu.MASTER BE 4.1 24 0 8 0, 192.0 ft2 0 0 :0.4 0 12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBC 7tti Edition (2020) Compliant Software Page 3 of 6 FORM R4.f)5_909n INPI IT, Al IMMORY iCLIPit'_KI.ICT 01=PnPT WALLS Adjacent Space Cavity Width Et n Height Ft In Area Sheathing' Framing R-41alue, Eracti6n Solar . Belouv Ahqor o 5 E=>N Exterior Concrete Block- Int InsuMASTER BE 4.1 13 0 8 0 104.0ft2 0 0 0.4 0 6 S=>E Exterior Concrete Block- Int InsuMASTER BE 4.1 - 14 0 8 0 112.0 ft2 0 0 0.4. 0 7 E=>N Exterior Concrete Block -1nt lnsul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 `, 0.4 0 8 S=>E Exterior Concrete Block - Int lnsul ENTRY 4.1 .1 0 8 0 8.0 ft2 0 0 0.4 0 9 S=>E Exterior Concrete. Block- Int lnsul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 10 N=>W Exterior Concrete Block- Int IrisuIGREAT/DINT 4.1 30 0 8 11 267.5 ft2 0 0 0.4 0 11 W=>S Exterior Concrete Block- Int InsuIGREAT/DINT 4.1 9 0 8 . 11 80.3 ft2 0 0 0.4 0 12 N=>W Exterior Concrete Block'- Int Insul BATH 2 4.1 8 .. 0 8 0. 64.0 ft2 0 0 0.4 0 _13 N=>W Exterior Concrete Block - Int InsuI51TTING RO 4.1 10 0 8 . 0 80.0ft2 0 0 0.4 0 14 S=>E Exterior Concrete Block- Int InsuISITTING RO .4.1 1 0 .8 0 8.0 ft2 0 0 0.4 0 _ 15 W=>S Exterior Concrete Block - Int InsuBITTING RO 4.1. 11, 0 . 8 0 88.0 ft2 0 0 0.4 0 _ 16 N=>W Garage Frame - Wood KITCHEN 11 32' 8 256.0 ft2 0.23 0.4 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 E=>N Insulated ENTRY None .32 3 6 8 20 ft2 WINDOWS Orientation shown.isiheentered orientation => chan ed:to.WorstCase. .' Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 W=>S 2, Metal _ Low-ESingle Yes 1.02 0.27 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior5. 2 S=>E 3 Metal Low-ESirygle Yes 1.02 0:27 Y 6.9 ft2 1 ft 0 in 1 ft4 in None None 3 E=>N 5 Metal Low-ESingle Yes 1..02 0.27 'Y 32.4 ft2 1 ft 0 in 1 ft4 in None None 4 N=>W 10 Metal Low-ESingle Yes 1.02 0.27 Y 18.4 ft2 1 ft 0 in 1 ft4 in None None 5, W=>S 11: Metal Low-ESingle Yes 1.11 0.27 Y 40:0 ft2 10 ft 0 in 1 ft4 in None : None, 6 N=>W 12 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 ft2 1 ft 0 in 1 ft 4 In None None 7 W=>S 15 Metal Low-ESingle Yes 1.02 �0.27, Y 18.4 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height ExposedWalilnsulation 1 320 ft2 320 ft2 32 ft 8 ft 11 - INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH, ACH 50 1 Wholehouse ProposedACH(50) .000254 1226 6726 126.28 .0902 • 5 12/29/20201:52 PM 7.0.60 - FlaRes2026 FBC 7th Edition (2020)• Compliant.Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS. / --supply ---- ---- Return ---- Air CFM 25. CFM25 HVAC # # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic -6 125 ft? Attic 40.ft2 DefaultLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Coolin HJan Feb Mar Heating Jan HFeb .Mar A r f Apr Ma Jun Jul f . May Jun Jul Au Aug Se Sep M Oct Nov Nov HDec Dec Ventin Jan Feb Mar [X] A r [ Ma Jun Jul Au Se .Oct [X] Oct Nov ' Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM• 78 78 78 78 78 78 78 78 80 80 80 80 PM( '80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78. 78 78 78 78 78 78 78 78 78. PM 78 78 78, 78 78 78 78 78 78 78 78 , 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68' 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 . 68 68- 68 , 68 66 66 MASS Mass Type Area Thickness FurnitureFraction Space Defaul t(8 lbs/sq.ft. 0 ft2 Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(816s/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2. ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(81bs/sq.ft. ft2 ft 0.3 GREAT/DINING 12/29/20201:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FQRM R405-2020 INPUT:SUMMARY. CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. ft2 ft 0.3 CLOSET 2 Default(8lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8lbs/sq.ft. ft2. ft 0.3 POWDER Default 8lbs/s .ft.. ft2 ft 0.3 SITTING ROOM 12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLEA02.4.1.1 AIR BARRIER AND INSULATION: INSPECTION COMPONENT CRITERIA a Project Name: GEMINI, Builder Name: WYNNE BUILDING CORP. Street:. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL; Permit' Number: Owner: Jurisdiction: ui Design Location: FL, fort Pierce U COMPONENT AIR BARRIER CRITERIA ' INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in thebuilding: envelope. Air -permeable 'insulation shall requirements The exterior thermal envelope"contains a. continuous. air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall:be'aligned with The insulation in an dro ed ceiling/soffit Y 9 /soffit the insulation and an a s in.the.air barrierstial.l be sealed. y 9 p air shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill:plate shall be sealed. Cavities within corners and headers of frame'walls The junction of the top plate and the top of exteriorwallsshall -be shall be insulated by completely filling the cavity sealed. w'ith'a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. . Exterior thermal envelope:insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between-window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of . Floor framing cavity insulation :shall be installed to (including.: insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framin cavity g insulation. and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor.franiing and extends fromthe bottom to the top of all perimeter floor framing. members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of -floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned s ace shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface.. thermal envelope shallbe airtight and IC rated. Plumbing`and wiring Batt insulation shall be cut neatly to, fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind sping and wiring- Shower/tub . The air barrier installed at exterior walis:adjacent to: showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them'from the showers and tubs. be insulated.. Electrical/phone box or The air.barriecshall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots - HVAC supply and return register boots that,penetrate building. thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that'is recommended. by the manufacturer... Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler rover Mates and walls or ceilinas, a. In addition,:inspection of log walls:shall be. in accordance with the provisions of ICC-400: 12/29/2020 1`.53.PM EneegyGauge® USA 7.0:00 - FlaiRes202O FBC.M Edition (2020) Compliant Software, Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL.'(EPL) :DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower. the EnergyPerf6rmance Index, the more efficient the home. FT. PIERCE, FL, 1. New construction or•existing New (From Plans) 10. Wall Type and Insulation. ' Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul; Exterior R=4.1 1507.80 ft2 b. Frame - Wood, Adjacent R=11.0 256.00 ft2. 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling TYPe and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1839.00 ft2 6. Conditioned floor area (ft2) 1839 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=1.02 115.28 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 125, SHGC: SHGC=0.27 b. U-Factor: Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kbtu/hr Efficiency c. U-Factor: N/A ft2. a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr : Efficiency 'Area Weighted Average. Overhang Depth: 8.318 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.270 8. Skylights. ' Description Area 15. Hot-water systems a. U-Factor(AVG): � N/A ft 2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.95 b. Conservation features 9. Floor Types Insulation .. Area None a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 . Credits -(Performance method) Pstat b. N/A R= ft2 c. N/A 'R= ftz 1 certify that this home has complied with.the Florida Energy Efficiency Code for Building Construction- through: the above energy saving features which:will be installed (or exceeded) in this_home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featured Builder Signature: Date: Address of New Home:`\ c a,l� ` City/FL Zip: 3u et s� *Note:.. This is not.a Building Energy Rating: If your Index is below 70,.your homemay qualify for energy.efficient. mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303:1.3 of the Florida Building Code; Energy Conservation, if not DEFAULT. 12/29/2020 1:52 PM 7.0.06 - FlaRes2026,FBC 7th Edition (2020). Compliant Software Page 1 of 1