HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY iEFFICIENCY CODE _FOR BUILDING CONSTRUCTION
Florida `Department of Business and Professional Regulation - Residential Performance Method
ProjectName: GEMINI� C
Street: v�
BuilderName: WYNNE BUILDING CORP.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber: '
Owner:
Jurisdiction:
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New.(FromPlans),
10. WallTypes(17.63.8 sqft.)
Insulation Area
2. Single family or multiple family Detached
a: Concrete Block- Int Insul, Exterior
R=4.1 1507.80 ft2
3. "Number of units, if multiple family 1
b. Frame- Wood, Adjacent
c. N/A
R=11.0 256.00 ft2 '
R= ft2
4. NumberofBedrooms 2
d.N/A
R= ft2
5. Is this a worst case? Yes
11. Ceiling Types " (1839.0 sqft. )
Insulation . Area
a: UnderAttic (Vented)
R=30.0 1839.00 ft2
6. Conditioned floorarea above grade (ftz) 1839
b. N/A _
R= ft2
Conditioned floorareabelowgrade(ftz) 0
c. N/A
R= ft2
7. Windows(155.3 sqft.) . " Description Area
12. Ducts
R ft2
a. U=Factor: Sgt, U=1.02 115.28 ft2
a. Sup: Attic,'Ret: Attic,'AH: Attic
6 125
SHGC: SHGC'--0.27
b. U•Factor: Sgl, U=1.11 40.00 ft2
13. Cooling systems
kBtu/hr " Efficiency
SHGC: 'SHGC=0.27
a. Central Unit
34.8 SEER:15.00
.c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 3.318 ft.
14.Heating.systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.270
A. Electric Heat Pump
34.8 HSPF:8.50
8. Skylights Area
c. U-FactOr:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric'
Cap:40 gallons
9. Floor Types (1839.0 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 1839.00ft2
b. Conservation features
b: N/A R= ft2
None
c. N/A R.= ft2
16..Credits :
Pstat .
Glass/Floor Area: 0.084 Total Proposed, Modified Loads: 51.52
PASS
Total Baseline Loads: 52.96
I hereby certify that the plans and specifications covered by .
Review of the plans and
this calculation are incompliance with the Florida Energy
specifications covered. by this
C!
Code.
"calculation indicates. compliance
y;�y
with the Florida Energy Code.
PREPAR9[ Y.
Before construction la completed"
_
DATE: L O
this building will be' inspected for
S
compliance with Section 553.908
1 hereby certify. that this:buiiding, as designed, is' in compliance
Florida Statutes.
with the Florida Energy Code.C'�,�
OWNER/AQ1R :
BUILDING OFFICIAL:
DATE. `
DATE:
- "Compliance requires certification by the air handier unit manufacturerthat the air handler enclosure qualifies as
certified factory -sealed" in accordance with R403.3.2.1. '
Compliance requires an Air Barrier'and Insulation Inspection Checklist in accordance -with 11402.4.1A and this""project requires
an envelope leakage test report with envelope leakage. no greater. than 5.00 ACH50. (R402.4.1.2).
REVIEWED F0h,
30CE CO PL1Aic
12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Editiq§120)�C � # ftyrar� Page 1 of 6
e
FORM R405-2020 INPUT RI IMMARY f_I41:rV1-ICT 1011=113nQT
PROJECT
'title: GEMINI
Bedrooms: 2
Address Type:
StreetAddress
Building Type: User
ConditionedArea: 1839
Lot#
OwnerName:
Total Stories: 1
Block/Subdivisiori:
#'of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE BUILDING CORP. RotateAngle: 270
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
FamilyType: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design DailyTemp
DesignLooation
TMY Site 97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
tow
BLOCKS
Number Name
Area Volume
1 Entire House
1839 14712
SPACES
.Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 BEDROOM
343 2744 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 M.BATH
56 448 No
0
1
Yes
Yes
Yes
4 KITCHEN
172 1376 Yes
0
1
No
Yes
Yes
5 MASTER BEDROO
256 2048 No
0
1
1
Yes
Yes
Yes
6 ENTRY
83664 No.
0
1
Yes
Yes
Yes
7 LAUNDRY
42 336 No
0
1
Yes
Yes
Yes
8 GREAT/DINING
568 4544 No
0
1
Yes
Yes
Yes
9 CLOSET 2
56 448 No
0
1.
No
Yes
Yes
10 BATH 2
48 384 No
0
1
Yes
Yes
Yes
11 POWDER
42 336 No
0
1
No
Yes
Yes
12 SITTING ROOM
110. 880. No
0
1
Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 43 ft 0
343 ftz
____
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
____
0 1
0.
3 Slab-On-GradeEdgelnsulation
- M.BATH 8ft 0
56ft2
____
0 1
0
4 Slab -On -Grade Edge Insulation
KITCHEN 1 ft 0
172 ft2
____
0 1
0
5Slab-On-Grade Edge Insulation
MASTER BEDRO 51 ft 0
256 ft'
____
0 1
0
12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
. JoistR-Value
Tile
Wood Carpet
6 Slab-On-GradeEdge Insulation ENTRY 7 ft 0
83 ft2
____
0
1
0
7Slab-On-GradeEdge Insulation LAUNDRY 6ft 0
42ft2
____
0
1
0
8Slab-On-GradeEdge Insulation ' GREAT/DINING 39 ft 0
568 ft2
____
0
1
0
9 Slab-On-GradeEdgelnsulation CLOSET 2 1 ft 0
56 ft2
____
0
1
0
10Slab-On=GradeEdgeInsulation BATH 2 8 ft 0
48 ft2
____
0
q
0.
11SIab-On-GradeEdge Insulation POWDER 1 ft 0
42ft2
-___
0
1
0
12SIab-On-GradeEdgelnsulation SITTING ROOM 22ft. 0
110ft2
0
1
0
ROOF
/
Roof Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1938 ft2. 0 ft2
Light
N
0.6
No 0:7
No 0
18.43
ATTIC
V
# Type Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented 150
1839 ft2
N
N
CEILING.
# CeilingType Space R-Value
Ins Type
Area
FramingFrac
Truss Type .
1 Under Attic (Vented) BEDROOM 30
Blown
343ft2
0.1
Wood
2 UnderAttic(Vented) WIC 30
Blown
63ft2
0.1
Wood
3 UnderAttic(Vented) M. BATH. `30
Blown
56 ft2
0.1
Wood
4 UnderAttic(Vented) KITCHEN 30
Blown
172ft2
0.1
Wood
5. Under Attic (Vented) MASTER BEDRO 30
Blown
256 ft2
0.1
Wood
6 UnderAttic(Vented) ENTRY 30'
Blown
83ft2
0.1
Wood
7 UnderAttic(Vented) LAUNDRY 30
Blown
42ft2
0.1
Wood
8 UnderAttid(Vented) GREAT/DINING 30
Blown
568ft2
0.1
Wood'
9 UnderAtfic (Vented) CLOSET 2 30
Blown
56 ft2
0.1
Wood
10 UnderAttic (Vented) BATH 2 30
Blown
48 ft2
0.1
Wood
11 UnderAttic(Vented) POWDER 30
Blown
42ft2
0.1
Wood
12 UnderAttic(Vented) SITTING ROOM 30
Blown
110ft2
0.1
Wood
WALLS
9Cavity
Adjacent Width
Space
. Height
Area
Sheathing: Framing
. Solar Below .
Ahsor o
1
S=>E . Exterior Concrete Block- Int Insul BEDROOM 4.1 29
0 8
0•
232.0 ft2.
0 0.
0.4
0
2
W=>S Exterior Concrete Block - Int Insul BEDROOM 4.1 14
0 8
0
112.0 ft2
0 0
0.4
0
3
S=>E Exterior Concrete Block - Int Insul M. BATH 4.1 8
0 8
0
64.0 ft2
0 0
0.4
0
4
N=>W Exterior Concrete Block - Int Insu.MASTER BE 4.1 24
0 8
0,
192.0 ft2
0 0
:0.4
0
12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBC 7tti Edition (2020) Compliant Software Page 3 of 6
FORM R4.f)5_909n INPI IT, Al IMMORY iCLIPit'_KI.ICT 01=PnPT
WALLS
Adjacent
Space
Cavity Width
Et n
Height
Ft In
Area
Sheathing' Framing
R-41alue, Eracti6n
Solar . Belouv
Ahqor o
5
E=>N Exterior
Concrete Block- Int InsuMASTER BE
4.1 13
0
8 0
104.0ft2
0
0
0.4
0
6
S=>E Exterior
Concrete Block- Int InsuMASTER BE
4.1 - 14
0
8 0
112.0 ft2
0
0
0.4.
0
7
E=>N Exterior
Concrete Block -1nt lnsul ENTRY
4.1 6
0
8 0
48.0 ft2
0
0 `,
0.4
0
8
S=>E Exterior
Concrete Block - Int lnsul ENTRY
4.1 .1
0
8 0
8.0 ft2
0
0
0.4
0
9
S=>E Exterior
Concrete. Block- Int lnsul LAUNDRY
4.1 6
0
8 0
48.0 ft2
0
0
0.4
0
10
N=>W Exterior
Concrete Block- Int IrisuIGREAT/DINT
4.1 30
0
8 11
267.5 ft2
0
0
0.4
0
11
W=>S Exterior
Concrete Block- Int InsuIGREAT/DINT
4.1 9
0
8 . 11
80.3 ft2
0
0
0.4
0
12
N=>W Exterior
Concrete Block'- Int Insul BATH 2
4.1 8 ..
0
8 0.
64.0 ft2
0
0
0.4
0
_13
N=>W Exterior
Concrete Block - Int InsuI51TTING RO
4.1 10
0
8 . 0
80.0ft2
0
0
0.4
0
14
S=>E Exterior
Concrete Block- Int InsuISITTING RO
.4.1 1
0 .8
0
8.0 ft2
0
0
0.4
0
_ 15
W=>S Exterior
Concrete Block - Int InsuBITTING RO
4.1. 11,
0 .
8 0
88.0 ft2
0
0
0.4
0
_ 16
N=>W Garage
Frame - Wood KITCHEN
11 32'
8
256.0 ft2
0.23
0.4
0
DOORS
# Ornt
DoorType Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 E=>N
Insulated ENTRY
None
.32
3
6 8
20 ft2
WINDOWS
Orientation shown.isiheentered orientation => chan ed:to.WorstCase. .'
Wall
Overhang
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1 W=>S 2,
Metal _ Low-ESingle Yes
1.02 0.27
Y
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior5.
2 S=>E 3
Metal Low-ESirygle Yes
1.02 0:27
Y
6.9 ft2
1 ft 0 in
1 ft4 in
None
None
3 E=>N 5
Metal Low-ESingle Yes
1..02 0.27
'Y
32.4 ft2
1 ft 0 in
1 ft4 in
None
None
4 N=>W 10
Metal Low-ESingle Yes
1.02 0.27
Y
18.4 ft2
1 ft 0 in
1 ft4 in
None
None
5, W=>S 11:
Metal Low-ESingle Yes
1.11 0.27
Y
40:0 ft2
10 ft 0 in
1 ft4 in
None :
None,
6 N=>W 12
Metal Low-ESingle Yes
1.02 0.27
Y
6.9 ft2
1 ft 0 in
1 ft 4 In
None
None
7 W=>S 15
Metal Low-ESingle Yes
1.02 �0.27,
Y
18.4 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
# FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
ExposedWalilnsulation
1 320 ft2 320 ft2
32 ft
8 ft
11
-
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH,
ACH 50
1 Wholehouse ProposedACH(50) .000254 1226 6726
126.28
.0902 •
5
12/29/20201:52 PM 7.0.60 - FlaRes2026 FBC 7th Edition (2020)• Compliant.Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 15
34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.95 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS.
/ --supply ----
---- Return ----
Air
CFM 25.
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic -6 125 ft?
Attic
40.ft2 DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Coolin HJan Feb Mar
Heating Jan HFeb .Mar
A r
f Apr
Ma Jun Jul
f . May Jun Jul
Au
Aug
Se
Sep
M
Oct Nov
Nov
HDec
Dec
Ventin Jan Feb Mar
[X] A r
[ Ma Jun Jul
Au
Se
.Oct
[X] Oct Nov '
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType 1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM• 78
78 78
78 78 78
78
78
80 80 80
80
PM( '80
80 78
78 78 78
78
78
78 78 78
78
Cooling (WEH) AM 78
78 78.
78 78 78
78
78
78 78 78
78.
PM 78
78 78,
78 78 78
78
78
78 78 78
,
78
Heating(WD) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68'
68 68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
.
68
68-
68 , 68 66
66
MASS
Mass Type
Area
Thickness FurnitureFraction
Space
Defaul t(8 lbs/sq.ft.
0 ft2
Oft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(816s/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft.
ft2.
ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(81bs/sq.ft.
ft2
ft
0.3
GREAT/DINING
12/29/20201:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FQRM R405-2020
INPUT:SUMMARY. CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
ft2 ft 0.3
CLOSET 2
Default(8lbs/sq.ft.
ft2 ft 0.3
BATH 2
Default(8lbs/sq.ft.
ft2. ft 0.3
POWDER
Default 8lbs/s .ft..
ft2 ft 0.3
SITTING ROOM
12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLEA02.4.1.1
AIR BARRIER AND INSULATION: INSPECTION COMPONENT CRITERIA a
Project Name: GEMINI, Builder Name: WYNNE BUILDING CORP.
Street:. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL; Permit' Number:
Owner: Jurisdiction:
ui
Design Location: FL, fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA '
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in thebuilding: envelope.
Air -permeable 'insulation shall
requirements
The exterior thermal envelope"contains a. continuous. air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall:be'aligned with
The insulation in an dro ed ceiling/soffit
Y 9 /soffit
the insulation and an a s in.the.air barrierstial.l be sealed.
y 9 p
air
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill:plate shall be sealed.
Cavities within corners and headers of frame'walls
The junction of the top plate and the top of exteriorwallsshall -be
shall be insulated by completely filling the cavity
sealed.
w'ith'a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum. .
Exterior thermal envelope:insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between-window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of .
Floor framing cavity insulation :shall be installed to
(including.:
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking,or floor framin cavity
g insulation.
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor.franiing and extends fromthe
bottom to the top of all perimeter floor framing.
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of -floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface..
thermal envelope shallbe airtight and IC rated.
Plumbing`and wiring
Batt insulation shall be cut neatly to, fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind sping and wiring-
Shower/tub .
The air barrier installed at exterior walis:adjacent to: showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them'from the showers and tubs.
be insulated..
Electrical/phone box or
The air.barriecshall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots -
HVAC supply and return register boots that,penetrate building.
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that'is recommended. by the manufacturer...
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler rover Mates and walls or ceilinas,
a. In addition,:inspection of log walls:shall be. in accordance with the provisions of ICC-400:
12/29/2020 1`.53.PM EneegyGauge® USA 7.0:00 - FlaiRes202O FBC.M Edition (2020) Compliant Software, Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL.'(EPL) :DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower. the EnergyPerf6rmance Index, the more efficient the home.
FT. PIERCE, FL,
1. New construction or•existing
New (From Plans)
10. Wall Type and Insulation. '
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul; Exterior
R=4.1
1507.80 ft2
b. Frame - Wood, Adjacent
R=11.0
256.00 ft2.
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
2
d. N/A
R=
ft2
5. Is this a worst case?
Yes
11. Ceiling TYPe and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1839.00 ft2
6. Conditioned floor area (ft2)
1839
b. N/A
R=
ft2
7. Windows" Description
Area
c. N/A
R=
ft2
a. U-Factor: Sgl, U=1.02
115.28 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 125,
SHGC: SHGC=0.27
b. U-Factor: Sgl, U=1.11
40.00 ft2
SHGC: SHGC=0.27
13. Cooling systems
kbtu/hr
Efficiency
c. U-Factor: N/A
ft2.
a. Central Unit
34.8 SEER:15.00
SHGC:
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
: Efficiency
'Area Weighted Average. Overhang Depth:
8.318 ft.
a. Electric Heat Pump
34.8
HSPF:8.50
Area Weighted Average SHGC:
0.270
8. Skylights. ' Description
Area
15. Hot-water systems
a. U-Factor(AVG): � N/A
ft 2
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
EF:0.95
b. Conservation features
9. Floor Types
Insulation .. Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 1839.00 ft2 .
Credits -(Performance method)
Pstat
b. N/A
R= ft2
c. N/A
'R= ftz
1 certify that this home has complied with.the Florida Energy Efficiency Code for Building
Construction- through: the above energy saving features which:will be installed (or exceeded)
in this_home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featured
Builder Signature: Date:
Address of New Home:`\ c a,l� ` City/FL Zip:
3u et s�
*Note:.. This is not.a Building Energy Rating: If your Index is below 70,.your homemay qualify for energy.efficient.
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303:1.3 of the Florida Building Code; Energy Conservation, if not DEFAULT.
12/29/2020 1:52 PM 7.0.06 - FlaRes2026,FBC 7th Edition (2020). Compliant Software Page 1 of 1