Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BLANDFORD RESIDENCE Builder Name: GEM BUILDERS Street: 4906 BUCHANAN DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Typ02720.0 sgft.) Insulation Area 2. Single family or multiple family Detached II a. Concrete Block - Int Insul, Exterior R=5.0 2200.00 IF b. Frame - Wood, Adjacent R=13.0 520.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (2369.0 sgfL) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2369.00 ft2 6. Conditioned floor area above grade (W) 2369 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows (358.0 sgft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 175 a. U-Factor: Sgl, U=0.24 358.00 ft2 SHGC: SHGC=0.15 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 41.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 7.067 ft.. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.150 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2369.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2369.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.151 Total Proposed Modified Loads: 72.13 PASS Total Baseline Loads: 76.60 I hereby certify that the plans and specifications covered by Review of the plans and QiTKE'STA this calculation are in compliance with the Flor da Energy specifications covered by this v = Code. calculation indicates compliance Code. Y: with the Florida Energy Before construction is completed r, -202 will be inspected for this building compliance with Section 553.908 x 4AThat this bui ng, signed, isin compliance Florida Statutes.Energy C de.N BUILDING OFFICIAL: - Compliance requires ce fication the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 11403.3:2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). OP 2/25/2021 8:31 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 I:nRnn PAnF..7n7n INPUT Sl1M AARY CHECKLIST REPORT ,., PROJECT Title: BLANDFORD RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2369 Lot Owner Name: Total Stories: - 1 Block/Subdivislon: # of Units: 1 Worst Case: No PlatBook: Builder Name: GEM BUILDERS Rotate Angle: 0 Street: 4906 BUCHANAN DRIV Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2369 23690 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M WIC 88 880 No 0 1 Yes Yes Yes 2 MASTER BEDROO 336 3360 No 0 1 1 Yes Yes Yes 3 M BATH 208 2080 No 0 1 Yes Yes Yes 4 M TOILET 24 240 No 0 1 Yes Yes Yes 5 AHU CLST 12 120 No 0 1 No Yes Yes 6 LAUNDRY RM 119 1190 No 0 1 Yes Yes Yes 7 GARAGE CLSTS 30 300 No 0 1 No Yes Yes 8 HALLWAY 89 890 No 0 1 No Yes Yes 9 DINING RM 216 2160 No 0 1 Yes Yes Yes 10 KITCHEN 216 2160 Yes 0 1 Yes Yes Yes 11 PANTRY 36 360 No 0 1 Yes Yes Yes 12 WIC 3 42 420 No 0 1 Yes Yes Yes 13 BEDROOM 3 156 1560 No 0 1 1 Yes Yes Yes 14 BATH 2 90 900 No 0 1 Yes Yes Yes 15 CLST 2 18 180 No 0 1 Yes Yes Yes 16 BEDROOM 2 159 1590 No 0 1 1 Yes Yes Yes 17 HALL 48 480 No 0 1 No Yes Yes 18 LIVING RM 432 4320 No 0 1 Yes Yes Yes 19 FOYER 50 500 No 0 1 Yes Yes Yes 2/25/2021 8:31 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 ;felVu1:Z(1F7tzfy� (11] INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value . Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M WIC 19 ft 0 88 ft2 1 0 0 2 Slab -On -Grade Edge Insulation MASER BEDRO 45 ft 0 336 ft2 1 0 0 3 Slab -On -Grade Edge Insulation M BATH 17 ft 0 208 ft2 1 0 0 4 Slab -On -Grade Edge Insulation M TOILET 3 ft 0 24 ft2 _e 1 0 0 5 Slab -On -Grade Edge Insulation AHU CLST 1 ft 0 12 ft2 _, 1 0 0 6 Slab -On -Grade Edge Insulation LAU DRY RM 7 ft 0 119 ft2 1 0 0 7 Slab -On -Grade Edge Insulation GAR GE CLSTS 1 ft 0 30 ft2 1 0 6 8 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 89 ft2 1 0 0 9 Slab -On -Grade Edge Insulation DINING RM 12 ft 0 216 ft2 1 0 0 10SIab-On-Grade Edge Insulation KITCHEN 12 ft 0 216 1`12 1 0 0 1 lSlab-On-Grade Edge Insulation PANTRY 6 ft 0 36 ft2 1 0 0 12SIab-On-Grade Edge Insulation WIC 3 13 ft 0 42 ft2 ._-_ 1 0 0 13SIab-On-Grade Edge insulation BEDROOM 3 12 ft 0 156 ft2 1 0 0 14SIab-On-Grade Edge Insulation BATH 2 loft 0 90 ft2 1 0 0 15SIab-On-Grade Edge Insulation CLST 2 2 ft 0 18 ft2 1 0 0 16SIab-On-Grade Edge Insulation BEDROOM 2 33 ft 0 159 ft2 1 0 0 17SIab-On-Grade Edge Insulation HALL 1 ft 0 48 ft2 1 0 0 18SIab-On-Grade Edge Insulation LIVING RM 14 ft 0 432 ft2 1 0 0 19SIab-On-Grade Edge Insulation FrOYER 15 ft 0 50 ft2 —� 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2649 ft2 0 ft2 Light N 0.3 No 0.9 No 20 26.6 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Unvented 0 2369 ft2 N N 2/25/2021 8:31 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FnRM PAnri9ngn INPUT _SUMMARY ICHFMI IRT RFPnRT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) M WIC 0 Blown 88 ft2 0.1 Wood 2 Under Attic (Unvented) MASTER BEDRO 0 Blown 336 ft2 0.1 Wood 3 Under Attic (Unvented) M BATH 0 Blown 208 ft2 0.1 Wood 4 Under Attic (Unvented) M TOILET 0 Blown 24 ft2 0.1 Wood 5 Under Attic (Unvented) AHU CLST 0 Blown 12 ft2 0.1 Wood 6 Under Attic (Unvented) LAUNDRY RM 0 Blown 119 ft2 0.1 Wood 7 Under Attic (Unvented) GARAGE CLSTS 0 Blown 30 f12 0.1 Wood 8 Under Attic (Unvented) HALLWAY 0 Blown 89 ft2 0.1 Wood 9 Under Attic (Unvented) DINING RM 0 Blown 216 ft2 0.1 Wood 10 Under Attic (Unvented) KITCHEN 0 Blown 216 ft2 0.1 Wood 11 Under Attic (Unvented) PANTRY 0 Blown 36 ft2 0.1 Wood 12 Under Attic (Unvented) WIC 0 Blown 42ft2 0.1 Wood 13 Under Attic (Unvented) BEDROOM 3 0 Blown 156 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 2 0 Blown 90 ft2 0.1 Wood 15 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 16 Under Attic (Unvented) BEDROOM 2 0 Blown 159 1`12 0.1 Wood 17 Under Attic (Unvented) HALL 0 Blown 48 ft2 0.1 Wood 18 Under Attic (Unvented) LIVING RM 0 Blown 432 1`12 0.1 Wood 19 Under Attic (Unvented) FOYER 0 Blown 50 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE Exterior Concrete Block - Int Inlsul M WIC 5 11 0 10 0 110.0 ft2 0 0 0.3 0 _ 2 SE Exterior Concrete Block - Int Inlsul M WIC 5 8 0 10 0 80.0 ft2 0 0 0.3 0 _ _ 3 NE Exterior Concrete Block - Int InisuMASTER BE 5 8 0 10 0 80.0 ft2 0 0 0.3 0 4 SE Exterior Concrete Block - Int In`suMASTER BE I 5 16 0 10 0 160.0 1`12 0 0 0.3 0 _ 5 SW Exterior Concrete Block - Int InsuMASTER BE 5 21 0 10 0 210.0 ft2 0 0 0.3 0 6 NE Exterior Concrete Block - Int Inlsul M BATH 5 9 0 10 0 90.0 ft2 0 0 0.3 0 _ 7 SE Exterior Concrete Block - Int Inlsul M BATH 5 4 0 10 0 40.0 ft2 0 0 0.3 0 _ _ 8 NW Exterior Concrete Block- Int Inlsul M BATH 5 4 0 10 0 40.0 ft2 0 0 0.3 0 _ 9 NE Exterior Concrete Block - Int In'sul M TOILET 5 3 0 10 0 30.0 ft2 0 0 0.3 0 10 NE Exterior Concrete Block - Int InsuLAUNDRY R 5 7 0 10 0 70.0 ft2 0 0 0.3 0 11 NW Garage Frame - Wood LAUNDRY R 13 5 0 10 0 50.0 ft2 0 0.1 0.3 0 _ 12 NW Garage Frame - Wood GARAGE CL 13 15 0 10 0 150.0 ft2 0 0.1 0.3 0 _ 13 SW Garage Frame - Wood GARAGE CL 13 2 0 10 0 20.0 ft2 0 0.1 0.3 0 _ 14 NE Garage Frame - Wood GARAGE CL 13 2 0 10 0 20.0 ft2 0 0.1 0.3 0 15 NW Garage Frame - Wood HALLWAY 13 4 0 10 0 40.0 ft2 0 0.1 0.3 0 16 SE Exterior Concrete Block- Int InsulDINING RM 5 12 0 10 0 120.0 ft2 0 0 0.3 0 _ 17 NE Garage Frame - Wood DINING RM 13 1 0 10 0 10.0 ft2 0 0.1 0.3. 0 18 SE Exterior Concrete Block- Int InW KITCHEN 5 12 0 10 0 120.0 ft2 0 0 0.3 0 19 SE Exterior Concrete Block - Int Insul PANTRY 5 6 0 10 0 60.0 ft2 0 0 0.3 0 _ WIC 10 0 70.0 ft2 0 0 0.3 0 _ 20 SE Exterior Concrete Block- Int Insul 3 5 7 0 _ 21 SW Exterior Concrete Block- Int Insul WIC 3 1 5 6 0 10 0 60.0 ft2 0 0 0.3 0 2/25/2021 8:31 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT �. WALLS Adjacent Space Cavity Width St In Height Et In Area Sheathing Framing RAW- Erectonn Solar Ahczor Below rZr:;de_0A _ 22 SW Exterior Concrete Block - Int InsuBEDROOM 3 5 12 0 10 0 120.0 ftz 0 0 0.3 0 23 SW Exterior Concrete Block - Int In'sui BATH 2 5 10 0 10 0 100.0 ft2 0 0 0.3 0 _ 24 SW Exterior Concrete Block -1nt Insul CLST 2 5 2 0 10 0 20.0 ftz 0 0 0.3 0 25 NE Exterior Concrete Block'- Int InsuBEDROOM 2 5 7 0 10 0 70.0 ft' 0 0 0.3 0 _ 26 SW Exterior Concrete Block - Int InsuBEDROOM 2 5 13 0 10 0 130.0 ftz 0 0 0.3 0 27 NW Exterior Concrete Block - Int InsuBEDROOM 2 5 13 0 10 0 130.0 ftz 0 0 0.3 0 _ _ 2B NW Exterior Concrete Block - Int Insul LIVING RM 5 14 0 10 0 140.0 ftz 0 0 0.3 0 _ 29 NE Garage Frame - Wood LIVING RM 13 18 0 10 0 180.0 ftz 0 0.1 0.3 0 _ 30 SW Exterior Concrete Block - Int Insul FOYER 5 5 0 10 0 50.0 ftz 0 0 0.3 0 _ 31 NW Exterior Concrete Block - Int I �sul FOYER 5 10 0 10 0 100.0 ftz 0 0 0.3 0 _ 32 NE Garage Frame - Wood FOYER 13 5 0 10 0 50.0 ftz 0 0.1 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated HALLWAY None . .23 3 8 24 ftz WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 4 Vinyl Low-E Single Yes 0.24 0.15 Y 54.0 ftz 2 ft 0 in 1 ft 4 in None None 2 SW 5 Vinyl Low-E Single j Yes 0.24 0.15 Y 40.0 ftz 2 ft 0 In 1 ft 4 in None None 3 NE 6 Vinyl Low-E Single Yes 0.24 0.15 Y 15.0 ftz 2 ft 0 In 1 ft 4 in None None 4 NE 10 Vinyl Low-E Single Yes 0.24 0.15 Y 8.0 ftz 2 ft 0 in 1 ft 4 in None None 5 SE 16 Vinyl Low-E Single Yes 0.24 0.15 Y 64.0 ftz 16 ft 0 in 1 ft 4 in None None 6 SE 18 Vinyl Low-E Single Yes 0.24 0.15 Y 12.0 ftz 16 ft 0 in 1 ft 4 in None None 7 SW 22 Vinyl Low-E Single Yes 0.24 0.15 Y 15.0 ftz 2 ft 0 in 1 ft 4 in None None 8 SW 23 Vinyl Low-E Single Yes 0.24 0.15 Y 6.0 ftz 2 ft 0 in 1 ft 4 in None None 9 NE 25 Vinyl Low-E Single Yes 0.24 0.16 Y 24.0 ftz 2 ft 0 In 1 ft 4 in None None 10 NW 27 Vinyl Low-E Single Yes 0.24 0.15 Y 18.0 ftz 2 ft 0 in 1 ft 4 in None None 11 NW 28 Vinyl Low-E Single Yes 0.24 0.15 Y 54.0 ftz 7 ft 0 in 1 ft 4 in None None 12 NW 31 Vinyl Low-E Single Yes 0.24 0.15 Y 48.0 ftz 12 ft 0 in 1 ft 4 In None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 624 ftz 624; ftz 50 ft loft 13 2/25/2021 8:31 AM EnergyGauge® UISA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R40W020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000444 2763.8 151.63 284.67 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ split Single SEER: 16 41 kBtu/hr 1230 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS — Supply — V # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 175 ft2 Attic 18 ft' Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Venting Jan Feb C Maarr ng Jan Feb Mar ��Apr Ceiling Fans: [X] [X] [ j Oct Apr May Jun [ ] Jul Aug I ] Sep 11 Oct Jun [ ]Jul Aug [ ]Sep lxl Nov C Nov LIDec Deec 2/25/2021 8:31 AM EnergyGauge® Ui SA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68. 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft, ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8lbs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(81bs/sq.ft. ft2 ft 0.3 GARAGE CLSTS Default(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8lbs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8lbs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(81bs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/s .ft. f? ft 0.3 FOYER 2/25/2021 8:31 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7