Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
i -�+ wri5'htsofta Project Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS(dAOL.COM For: BLANDFORD RESIDENCE GEM BUILDERS 4906 BUCHANAN DRIVE, FORT PIERCE, FL Notes: f r Winter Design Conditions Outside db 1 42 Inside db 70 Design TD ! 28 i Heating Summary Job: Date: FEB. 25, 2021 By: RECEIVED MAR 0 2 2020 ST. Lucie County, Permitting Summer Design Conditions OF Outside db 90 OF OF Inside db 75 OF OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 24862 Btuh Structure 20673 Btuh Ducts 7210 Btuh Ducts 10170 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32072 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 29302 Btuh Method Simplified p Latent Cooling Equipment Load Sizing Construction quality 1 Average Fireplaces 0 Structure 3639 Btuh Ducts 2799 Btuh Central vent (0 cfm) 0 Btuh Heating I Cooling (none) Area (fta) 23691 2369 Equipment latent load 6438 Btuh Volume (fta) 236901 23690 Air changes/hour 0.32 ' 0.16 Equipment Total Load (Sen+Lat) 35739 Btuh Equiv.AVF (cfm) 1261, 63 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6042J 1 AHRI ref Coil TEM4AOC42S41++TDR AHRI ref 8703699 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 18.4 kW Sensible cooling 28700 Btuh Heating output 28559 Btuh Latent cooling 12300 Btuh Temperature rise ' 19 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1, 00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 V Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -F- wrightaoft- 2021-Feb-25 08:28:12 """a" RlghtSuite® Universal 2021 21.0.02 RSU08101 Page 1 ... cumnets\WNghtsoftWVAC\BLANDFORD RESIDENCE.rup Calc = MJ8 Front Door faces: NW i A Job: -fj;+- wrightsoft Right-J® Worksheet Dat Entire House Date: FEB. 25, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL $4946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House M WIC 2 3 EVosed wall Room height 220.0 ft 10.0 ft 19.0 It 10.0 ft heat/cool 4 5 Room dimensions Room area 2369.0 ft2 8.0 x 11.0 ft 88.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 ' 13Pr5ocs 2 glazing, cir low-e 2 glazing, cir lcw-e 0.125 0.240 0.240 ne ne ne 3.50 6.72 6.72 1.91 13.88 13.88 450 8 15 403 0 0 1411 54 101 771 111 208 110 0 0 110 0 0 385 0 0 . 210 0 0 I��---GGG V�! 11 2 glazing, cirlow-e 13X5ocs 0,240 0.125 ne se 6.72 3.50 13.88 1.91 24 650 0 520 161 1820 333 994 0 80 0 80 0 280 0 153 I- 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 0.240 0.240 0.240 se se se 6.72 6.72 6.72 9.49 10.99 11.74 12 54 64 7 22 20 81 363 430 114 593 751 0 0 0 0 0 0 0 0 0 0 0 0 -C �t---!{ 13A-5ocs 2 glazing, cir low-e 2 glazing, clr low -a 2 glazing, cir low-e 13A-5ocs 0.125 0.240 0.240 0.240 0.125 sw .sw sw sw nw 3.50 6.72 6.72 { 6.72 3.50 1.91 8.00 10.39 11.7.4 1.91 690 6 15 40 410 629 5 7 12 290 2262 40 '101 269 1015 1203 48 156 469 555 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (G T:::G 2 glazing, dr low-e 2 glazing, cir low-e 0.240 0.240 nw nw 6.72 ( 6.72 13.88 13.88 72 48 0 0 484 323 999 666 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 -_ 1.59 1,37. 2369 - 2369 3756 3241 88 88 140 120 F 22Artph 1.358 - , 38.02 'l i 0.00 2369 220 8365 .0 88 19 722 0 6 c)AED excursion 1 319 -32 Envelope loss/gain 20974 11532 1527 452 12 a) Infiltration 38BB 1041 336 90 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 1 230 0 0 0 0 Appliances/other 8100 300 Subtotal Qlnes 6 to 13) 24862 20673 1863 841 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 .0 0 14 Subtotal 24862 20673 1863 841 15 Duct loads 29% 49% 7210 10170 29% 49% 540 414 Total room load 32072 1 30844 2403 1255 Air required (cfm) 1367 1367 102 56 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 4 - wrlgl �tsoft- 2021-Feb-25 08:28:12 A " """° """ " " " RightSuite® Universal 2021 21.0.02 RSU08101 Page 1 ...cumnetslWrightsoff WAC\BLANDFORD RESIDENCE. rup Calc = MJ8 Front Door faces: NW -�- wrightsofts Right-J® Worksheet Job: ` Entire House Date: FEB. 25, 2021 QUICK CALCSr INC. BY: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77.2-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM M BATH 2 Exposed wall 45.0 ft 17.0 ft 3 Room height 1 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 16.0 x 21.0 ft 336.0 W 1.0 x 208.0 ft 208.0 ft' Ty Construction number U-value (Btuh/ft-'F) Or HTM (Btuh/ft2) Area (ft-) or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13X.socs 2 glazing, cir low-e 2 glazing, clr low-e 0.125 0.240 0.240 ne ne no � 3.50 6.72 I 6.72 1.91 • 13.88 13.88 80 0 0 80, 0 0 286 0 0 153 0 0 90 0 15 75 0 0 263 0 101 143 0 208 11 2 glazing; cir low-e 13A-5ocs 0,240 0.125 no se 6,72 3.50 13,88 1.91 0 160 0 106 0 371 0 203 0 40 0 40 0 140 0 76 2 glazing, clr low-e 2 glazing, cIr low-e 2 glazing, cir low-e 0.240 0.240 0.240 se se 6.72 6.72 6.72 9.49 10.99 11.74 0 54 0 0 22 0 0 363 0 0 593 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5ocs 2 glazing, cir low-e 0.125 0.240 "se sw sw ; 3.50 ' 6.72 .1.91 8.00 210 0 170 0 595 0 325 0 .0 0 0 0 0 0 0 0 2 glazing, cir lows 2 glazing, clr low-e 13A-5ocs 0.240 0.240 0.125 sw sw nw i 6.72 f 672 3.60 10.39 11.74 1.91 0 40 0 0 12 0 0 269 0 0 469 0 0 . 0 40 0 0 40 0 0 140 0 0 76 V�! 2 glazing, cir low-e 2 glazing, cir low-e 16X19-0md ' 0.240 0.240 0.408 nw nw - 6.72 6.72 1.59 13.88 13.88 1.37 0 0 336 0 0 336 0 0 533 0 0 460 0 0 208 0 0 208 0 0 330 0 0 285 I-G ��-���-��GGGGG G F 22A-tph 1.358 - 38.02 0.00 336 45 1711 0 208 17 646 0 " t 1 I I. f f I if - 6 c)AED excursion -137 -32 Envelope loss/gain 4121 2067 1619 757 12 a) Infiltration 795 213 300 80 b) Room ventilation 0 0 0 0 13 Internal gains: Occupant's @ 230 0 0 0 0 Appliances/other 1500 0 Subtotal (lines 6 to 13) 4917 3780 1920 838 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 17 14 44 37 14 Subtotal 4933 3794 1964 874 15 Duct loads 29% 49%1 1431 1866 29% 49% 569 430 Total room load 6364 1 5660 2533 1 1304 Air required (cfm) 971 251 108 58 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -:+- wrightsoft ^ 2021-Feb-25 08:28:12 Right-Suite® Universal 2021 21.0.02 RSU08101 Page 2 ... cumnstslWdghtsoftHVAC\BLANDFORD RESIDENCE.rup Calc = MJ8 Front Door faces: NW V 0 w h! CT A W N o O cn A W N -• ��Smm OR3333 77— !Ti_n 2 i ` J_ T�j77 77 7 7 7 7 77 Zmmp N �¢ n CD .. cc fo tpp �ctotc 3r 7 q_M Q Asa a 2a2 a as — o ,, 0 c C 0000000000000000. CD y c�w(,�71 NAN N�IV'N +77 IJNN-+,Np NtJ-� M ODO OANOO O(IIOOOfN71 O.O OCN71 v S`G --- .7 7 000 N CN.NC CD mmm0 W m'mm CD ` O 8 N N S N N N S. NN N SI N.N N S � •iN`� ' 4 4• O�OOoo(ji1 _a�.'p Qp .a�O�pp fO�WW'�Wp QWp .... aDST ''4 ST A(OO �.S SS-O+. ... .SV o Nrsa0000000'00000000 3� o 0 f0 cal! A - 0 0 00c, 0 0 0 0 0 0 0 008 CA • -. x O rm A V o (p w O O O O O W O CD Es��71 (N V "A:S O O O 0.000 O O O O O-.O 0 0 C �j S fD y� NN AW000 N SO OA (VD O woo 000,000000000V'' ,� I NN0000000.00000.0.00- �^ O C e j coo O'O 0 0 0 0 0 0 0 C X 0 O 00 0080o is 1 oo cc occ000000000000000 r �$ (Cp1 O O O O O p O O) O O O O T O O O O p O O O O O O O O O O O O Z H m O 0 1 v m 0 m -4 O CD rn rF 4 S R FF C n 0 r n N I 0 O 9 - wrightsoft° Right-l® Worksheet Job: ` Entire House Date: FEB. 25, 2021 QUICK CAws, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77,2-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUNDRYRM GARAGE CLSTS 2 Bgmed wall 7.0 ft 0 It 3 Room height I 10.0 ft heat/cool 10.0 It heat/cool 4 5 Room dimensions Room area 17.0 x 7.0 ft 119.0 ftz 15.0 x 2.0 It 30.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ftj Load number (Btuh/ft-L°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Grams N/P/S Heat Cool 6 yJ 13A-5ocs 2 glazing,'cir low-e 6.125 0.240 .ne no 3.50 ! 6.72 1.91 13.88 70 .6 62 0 217 54 . 119 111 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0:240 ne 6.72 13.88 0 0' 0 0 .0 - 0 0 0 11 Zglazing; cir low-e 13A5acs 0.240 0.125 ,ne, se 6.72 3.50 . 13.88 1.91 0 0 0. 0 A, 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.240 0.240 0.240 se se se 6.72 6.72 6.72 9.49 10,99 11.74 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-Sacs ', - 2 glazing, •cir low-e 0.125 0.240 sw, sw 4 3.50 6.72 1.91 8.00 , 0 0 0 0 .0 0 0 0 0 0 0 0 0 0 0 0 2 glazing 'cir low-e. - 2 glazing, cir low-e 0240 0.240 0.125 sw sw nw ( 6:72 'j 6.72 3.50 10.39 . J1.74 1.91 " 0 " 0 0 0 0 0 0 0 0 0 0 0 0 , 0 0 0 0 0 0 0 0 0 0 0 W13A-6ocs 2 glazing, cir low-e 2 glazing, clr low-e 16XlMnid 0.240 0.240 0.408 nw nw 6.72 l 6.72 1.59 13.88 13.88 . 1.37 0 0 119 0 0 119 0 0 . 18.9 0 0 163 0 0 _., _ 30 0 0 30 0 0 48 0 0" 41 C - F 22A-tPh. 1.358 - 38.02 0.00 119 7 266 0 30 0 0 0 { 4 6 c)AED excursion -34 -2 Envelope loss/gain 726 3581. 48 40 12 a) Infiltration 124 33 0 0 b) Room ventilation 0 0 0 0 13 i Internal gains: Occupants @ 230 0 0 0 0 Appliances/other Sm 0 Subtotal nines 6 to 13) 849 891 48 40 Less extemal load 6 0 0 0 Less transfer 0 0 0 0 Redistribution 77 64 -48 -40 14 Subtotal 926 955 0 0 15 Duct loads 29% 49% 269 470 29% 49% 0 0 Total room load 1194 1425 0 0 Air required (cfm) 511 63 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FId- I 2021-Feb-25 08:28:12 �cA "'""'° """'"""` Right -Suite® Universal 2021 21.0.02 RSU08101 Page 4 cumnetslWdghtsoft HVACIBLANDFORD RESIDENCE.rup Calc = MJS Front Door faces: NW i - wrightsoft° Right-J6 Worksheet Job: Entire House Date: FEB. 25, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-486.6799 Fax 772-466-6796 Errreil: QUICKCALCS@AOL.COM 1 Room name HALLWAY DINING RM 2 Exposed wail 0 ft 12.0 ft 3 Room height 10.0 ft heaUcool 10.0 ft heal/cod 4 5 Room dimensions Room area ) 1.0 x 89.0 ft 89.0 ft' 12.0 x 18.0 ft 216.0 ft' Ty Construction number U-value (Btuhlft2--F) Or I HTM (BtuhKt2) Area (ft') or perimeter (ft) Load (Btuh) Area (" or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 13A-56cs ' 0.125 net 3.50 1.91 0 0 0 0`' 0 0 0 0 11 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, dr low-e 13A-5ocs 0.240 0.240 _ 0.240 0.125 ne ne � : neJ se' 6:72 6.72 6.72 3.50 1388 13.88 13.88 1.91 0 0 0 0 � 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 0 0 '. 0 56 0 0 0 196 0 0 0 107 2 glazing, clr low-e 2 glazing, dr low-e 2 glazing, cir low-e 0.240 0.240 0.240 se l se se, 6.72 6.72 6.72 9.49 10.99 11.74 0 0 0 0 0 0 0 0 0 0 0 0 0 0 64 0 0 20 0 0 430 0 0 751 --G �I------GG 13A 5ocs 2 glazing, clr.low-e 0.125 0:240 sw sw 9.50 6:72 1:91 8.00 .0 0 0 0 '. • 0 0 0 0 0 0 0 0 0 0 0 0 2glazing, clrlow-e 2 glazing, drlow-e; ' 0.240 0:240 sw' , sw 6,72 6.72 `10.39 11.74 '0 . _ 0 0 ` 0 0 - ; 0 0 0 0 0 0 0 0 0 0 0 w 13A 5ocs 0.125 nw 3.60 1.91 0 0 0 0 0 0 0 0 2 glazing, clr low -a 2 glazing, cir low-e 0.240 0.240 nw nw 6.72 6.72 13.88 13.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.37 89 89 141 122. 216 216.. 342 29t F 22A-tph 1.358 , - 38.02 0.00 89 0 0 0 216 12 456 0 6 c)AED excursion 1 -4 257 Envelope loss/gain 141 117 1425 1411 12 a) infiltration 0 0 212 57 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 2W 0 0 0 0 Appliances/other 0 1 650 Subtotal Dines 6 to 13) 141 117 1637 2118 i Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -141 -117 71 59 14 Subtotal 0 0 1707 2176 15 Duct loads 291/6 49% 0 0 29% 49% 495 1071 Total room load 0 0 2203 3247 Air required (cfm) 0 01 1 94 144 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A- wrtgtitsoT I 2021-Feb-25 08:28:12 "'""'"""" """" ' Right -Suite® Universal 2021 21.0.02 RSU08101 Page 5 ... cumnets\Wdghtsoft WAC\BLANDFORD RESIDENCE.rup Calc = MJ8 Front Door faces: NW. - wrightsoft" I Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772466-6796 Email; QUICKCALCS@AOLCOM Job: Date: FEB. 25, 2021 By: 1 Room name KITCHEN PANTRY 2 Exposed wall 12.0 ft 6.0 ft 3 Room height 10.0 ft heaUcool 10.0 ft heaticool 4 5 Room dimensions Room area 12.0 x 18.0 ft 216.0 ft2 6.0 x 6.0 It 36.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuhlffvF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 2 glazing, cir low-e 2 glazing; cir low-e 0.126 0.240 0.240 ne no ne 3:50 6.72 6.72 1.91 13.88 13.88 -" 0 -0 0 0 0 0 .' 0. 0 0 0 0, 0 0 0 0' 0 0 0 0 0 0 0. 0 0 2 glazing, cir low-e , 0.240 -ne ,. 6.72 . - 13.88 0 0 . - 0 , 0 0 0, 0 0 11 13A-5ocs 0.125 se 3.50 1.91 120 108 378 207 60 60 210 115 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.240 0.240 0.240 se se se 6.72 6.72 6.72 9.49 10.99 11.74 12 0 0 7 0 0 81 0 0 114 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 13A5ocs 2 glazing, cir low-e 2 glazing, cirlow-e, 2'glazing,,clrlow-e 13A5 ocs 0.125 0.240 0,240 0.240 0.125 'sw sw sw sw` nw f 3.50 6.72 6.72 6.72 3.50 • 1.91 8.00 10.39 11.74 1.91 0 0. 0 . 0.1 0 0 0 ..0 0 0 ,0 0 0 0 0 0 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 II{ -6 T 2 glazing, cir low-e 2 glazing, cir low-e 0.240 0.240 rw nw 6.72 6.72 13.88 13.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 :2 C 16X19-0md 0.408 - 1.69 1.37 , 216 .216. '342 . 296 36 36 57 49 F- 22A-tph 1,358 - 38.02 i , 0.00 .216 12 456 0 36 6 . 228 0 II •I t . 6 c)AM excursion -40 -7 Envelope bss/gain 1257 576 495 167 12 a) Infiltration 212 57 106 28 b) Room ventilation 0 0 0 0 13 home gains: Occupants Q 230 0 0 0 0 1 Appliances/other 1 1600 0 Subtotal (lines 6 to 13) 1469 2233 601 185 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1469 2233 601 185 15 Duct loads 29% 49% 426 1098 29% 49% 174 91 Total room load F1896 3331 776 276 Air required (cfm) 81 148 33 12 I Calculations approved WACCA to meet all requirements of Manual J 8th Ed. -FI.F wrightsoTt 2021-Feb-25 08:28:12 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 6 ...cumnets%Wdghtso8 WAMBLANDFORD RESIDENCE.rup Calc = MJ8 Front Door faces: NW i 1 e6ed mN .seoe} joo0 luojd 9rn = oleo dru•30N301S3M OMOdONVISXOVAH gosl46pM%sleuwno••• 40L9onSM ZO'0'LZ 4ZOZ ioriamun c9allnS-146IM ZL:8z:909Z-gad-LZOZ 1 sa;ogy6sam " P� Ms r lenuew jo sluaweipbei HE leew Ol VOOV q POAOJCICIU suollelnoleo 04 LL EZ 99 (wdo) p81lnbw j.M Z617Z 96LL 9Z9 L09L Peol woos lelol ZZ9 tot "/o6V %6Z VLL L9£ 0/66V %6Z I smi Iona 54 LL94 V6E4 V9£ 9VZ4 IelolgnS VL 9 oL 0 0 uolingPlslPatl 0 0 0 0 Jolsuail sse-I 0 0 0 0 peol WOW sse-1 Z99L VM VSE 9VZL i (EL ol9 saul0 IelolgnS 0004 0 je4lo/ssouepd* 0 0 0 0 0£Z sluedn000 :Su1e6lewalul £L 0 0 0 0 uollallluen wootl (q L9 ZLZ Z9 o£Z uollwlLlul (e ZL gm ZLLL £6Z 940E ule6/ssol edolaw3 SE V4- uols naxe O3'd(o 9 I 0 99V Z4 99L ` 0 roo EL ZV 0010 Wee " 89£'l , 4dlb2Z d £LZ LVZ 99L 99L LS L9 ZV' ' ZV LET6S'L -, 80V'0 Pw06LX94 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 99'£L 9 OM ZL'9 ZL'9 mu mu OVZ'0 OVZ'0 e-Nq Jp '6u1ze16 Z e-mol Jp 'Bulzel6 Z 0 0 99L 0 0. 10L 0 0 L- 0 6. 9L 0 0 0 0 0" . 0 0 0 0 0 o , 0 ' L6'L VL'LL 6E'OL ° 09'£ ZL'9 ZL'9 '9 mu ms ms SZ4'0 OVZ'0 OVZ•O sooweE a-mofp �'Buhl6 Z e-moI jp 'BuIze16 Z 0 0 0 0 0 0 0 0 00'9 ZL'9 .ms OVZ'0 e-mol ip Bulze16 Z LOZ 89£ SOL', OZL, 9LL oz 09 09 Wl 09'E °ms.9ZVO sbog-VeL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 VL'L4 66% ZL'9 ZL'9 es es OVZ'O OVZ'O s-moI jp '6ORO Z e-mol ap '6ulze16 Z 0 0 0 0 0 0 0 0 6V'6 ZL'9 es OVZ'o s-mol -0o 'BulzelB Z //�//j����1 0 0 0 0 0 0 0 0 V£4 0 SVZ 0 OL 0 - OL 0 46'L 99'£L OS'E ZL'9 I es eu ' SZL'0 OVZ'O soovM s-nnol Jp 'Burzel6 Z: L L 0 0 0 0 0 0 0 0 0 0 0 0, 0 0, 0 89'£6 NUZL'9 ZL'9 eu 1.eu " oVZ'0 OVZ'O -e-NOI �p 'Bu¢e16 Z e-mol Jp 'BUIZOIB.Z—I ''0 i 0 0 0. 0 0• 0 0 0 L6'L. 09'£ feu SZL'0 _ soo9'd£4 ffrrAA 9 POO le8H S/d/N ssoJO POO leeH S/d/N ssa1O 1000 leeH I IC) (d.-.UXn19) enlPA-n jagwnu uollorulsu00 A.L (4nlg) PWI (4) jalewuad jo (eu) ew (4nig) Peol (u) lelewuad jo (sl)) Ew (zll/4nlg) n1H Lu O'94L zu OZV sale wooM S u OZL X O'EL u 0'9 X OL SWISuewlp wood V Ioa/lea4 u 0'OL u o'ZL l000/1e84 u 0'OL a O'EL 1461e4 wooM Il—Pasocba E Z E nOONMS £ ON eweu wOOM L :Ag LZOZ'BZ'83d mea :qor n00'IOditow0N01no :o-3 96L9-99V ZLL -j 66L9-991,-ZLL :su04d 9464E 1:1 '30M31d 1MOd '3NVI 310n11S LLE '3NI `s3wo moini) esnoH aAMu3 ;aays)ljoM gIr-}yBib i �Uos4tj6iann - ►- wrightsoft Right -A Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-066-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM Job: Date: FEB. 25, 2021 By: 1 Room name BATH 2 CLST 2 2 3 E�rosed wall Room height 10.0 ft 10.0 ft heat/coot 20 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 10.0 ft 90.0 ft' 9.0 x 2.0 ft 18.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (fn Load number (Btuh/ft'--'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) � Heat Cool Gross NIP/S Heat Cod Gross N/P/S Heat Cool 6 13A-5ocs 2 glazing, cir low-e 2 glazing, dr low-e 0.125 0.240 0.240 ne ne ne ' 3.50 1 6.72 6.72 1.91 13.88 13.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0. 0 0 w 11 2 glazing,. dr-low-e 13A-5ocs 0.240 0.125 ne se { 6.72 I 3.50 , 13.88 1.91 , 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.240 0.240 0.240 se se se 6.72 6.72 6.72 9.49 10.99 11.74 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir love-e . 0.125 0.240 sw sw r 3.50 6.72 1.91 8.00 100 6 94 5 329 40 180 48 - 20 0 20 0 70 0 38 0 Ti13A-5ocs 2 glazing, cir low-e 2 glazing,, clrlow-e 13A-6ocs 0:240 0.240 0.125 sw sw rnv f 6.72 1 6.72 3.50 ' 10.39 11.74 1.91 0 0 0 0 0 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 0.240 0.240 nw nw 1 6.72 1 6.72 13.88 13.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.37 90 90 143 123 18 18 29 25 F 22A-tph 1.358 - 38.02 i i i i i F 0.00 90 10 380 0 18 2 76 0 6 c)AED excursion 19 -3 Envelope loss/gain 892 370 175 60 12 a) Infiltration 177 47 35 9 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 200 0 subtotal (lines 6 to 13) 1069 618 210 70 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 130 56 -210 -70 14 subtotal 1199 674 0 0 15 Duct loads 29% 49% 348 331 29% 49% 0 0 Total room load 1547 1005 0 0 Air required (cfm) 66 45 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk- wrtgtitsofe" I 2021-Feb-2508:28:12 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 8 ...cumnetslWrightsoft WACIBLANDFORD RESIDENCE.rup Colo = MA Front Door faces: NW -�- wrigFatsoft Right-J@ Worksheet Job: Entire House Date: FEB. 25, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: QUICKCALCS@,AOL.COM 1 Room name BEDROOM 2 HALL 2 Exposed wall 33.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 159.0 ft 159.0 ft2 4.0 x 120 ft 48.0 ft2 Ty Construction U-value Or I HTM Area (ft2) Load Area (ft' Load number (Btuh/ftkPF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 0.125 ne 3.50 1,91 70 46 161 88 0 0 0 0 2 glazing, dr low-e 2 glazing, cir low-e 0240 0.240 ne ne ` 6.72 6.72 13.88 13.88 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 �i13A5ocs ' 11 2 glazing, cir low -a 13A-5ocs 0,240 0.125 ne" se I 6:72 3.50 13.88 1.91 24 0 0 0 161 0 333 0 0 0 0 0 0 0 0 0 E-G 2 glazing, clr low-e 0.240 se 6.72 9.49 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.240 se 6.72 10.99 0 0 0 0 0 0 0 0 l�_GG 2 glazing, dr low-e 0.240 se 6.72 11.74 0 0 0 0 0 0 0 0 13A5ocs 2 glazing, cir low-e, 0.125 0.240 sw sw 3.50 6.72 1.91 8.00 130 0 130 0 455 0 249 .0 0 0 0 0 0 0 0 0 2 glazing, dr,low-e 0.240 , sw '6.72 10.39 0 0 0 0 0 0 0 0 V�! 2 glazing, dr low-e 13A 5ocs 0.240 0.125 . sw nw 6.72 3.50 11.74 1.91 0 130 0 112 0 392 0 214 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, dr low -a, 0.240 0.240 nw nw 6.72 6.72 13.88 13.88 18 0 0 0 121 0 260 0 0 0 0 0 0 0 0 0 I�--(G' C 16X19-0md 6.408 - 1.59 1.37 159 159 252 ` 218 48 48 76 66 F 22A tph 1.358 - 38.02 ,I I 0.00 159 33 1255 0 48 0 0 0 6 c)AED excursion -61 -2 Envelope loss/gain 2797 1291 76 63 12 a) infiltration 583 156 0 0 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 250 0 Subtotal (lines 6 to 13) 1 3380 1697 76 63 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 115 43 -76 -63 14 Subtotal 3495 1740 0 0 15 Duct loads 29% 49% 1014 856 29% 49% 0 0 Total room load 4509 2596 0 0 Air required (cfm) 192 115 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A-- -FP- wrigti!t:ncwe�- 2021-Feb-25 08:28:12 AEEA�"""" RightSuite® Universal 2021 21.0.02 RSU08101 Page 9 ... cumnets%WdghtsoftWACIBLANDFORD RESIDENCE.rup Calc = MJ8 Front Door faces: NW + wrightsoft, I Right-JWorksheet Entire H,, ouse QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emall: QUICKCALCS@AOL.COM Job: Date: FEB. 26, 2021 By: 1 Room name LIVING RM FOYER 2 Exposed wall 14.0 ft 15.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft hwycool 4 5 Room dimensions Room area 24.0 x 18.0 ft 432.0 ft' 10.0 x 5.0 ft 50.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ftj Load number (Btuh/ftILT) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-S - 2 glazing;. cir low-e 2 glazing, cir low-e 0.125 0.240 0.240 ne ne ne 3.50 6.72 6.72 1.91 13.88 13.88 0 0 0 0 0 0 0 0 0 '0 0 0 '0 0'° 0 0 0 0' 0 0 0 0 0 0 11 2glazing, cirlow-e 13A-5ocs 0.240 0.125 no se l 6.72 3.50 13.88 1.91 _ 0' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G 2 glazing, clr low-e 0.240 se 6.72 9.49 0 0 0 0 0 0 0 0 1�----GG 2 glazing, cir low-e 2 glazing,, cir low-e 0.240 0.240 se se 6.72 6.72 10.99 11.74 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5ocs 0.125 sw 3,50 1.91 . 01 0 0 0 50 50 175 96 2 glazing,.cIr low-e 0.240 sw 6.72 &00 0 0 0 0 0, 0 0 0 2 glazing, dr low-e 2 glazing dr low-e 13A,Socs 0.240 0.240 0.125 sw sw nw 6.72 6.72 3.50 10.39 11.74 1.91 0 0 140 0 0 86 0 0. 301 0 0 164 0 0 100 0 0 52 0 0 182 0 0 99 2 glazing, clr low-e 2 glazing, cir low-e 16X19-0md 0.240 0.240 0.408, nw nw - 6.72 6.72 1.59 13.88 13.88 1.37 54 0 432 0 0 432 363 0 685, 749 0 591 0 48 50 0 0 _ - 60 0 323 79 0 666 68 C F 22A•tph i 1.358 - 38.02 li I i 0.00 • 432 14 . 532 0 50 15 570 0 6 c)AED emurslon 204 183 Envelope loss/gain 1881 1709 1329 1113 12 a) Infiltration 247 66 265 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1 900 1000 Subtotal (lines 6 to 13) 2129 2675 1594 2184 Less exlemal load 0 0 0 0 Less transfer i 0 0 0 0 Redistribution 30 25 01 0 14 Subtotal 2159 2700 1594 2184 15 Duct loads 29% 49% 626 1328 29% 490A 462 1074 Total room load 1 2785 4028 1 2057 I 3258 Air required (cfm) 119 179 88 144 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigF�tsolFt 2021-Feb-25 08:28;12 RightSuite® Universal 2021 21.0.02 RSU08101 Page 10 ...cumnetslWdghtsofl WAC\BLAND FORD RESI D ENCE. rup Calc = MJ8 Front Door faces: NW wrightsoft® Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS c�1 OL.COM For., BLANDFORD RESIDENCE, GEM BUILDERS 4906 BUCHANAN DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1367 cfm Job: Date: FEB. 25, 2021 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1367 cfm 201 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 1547 66 45 1.000 6.0 Ox 0 VIFx 44.4 135.0 st3 BEDROOM 2 h 4509 192 115 1.000 7.0 Ox 0 VIFx 50.8 135.0 st3 BEDROOM 3 c 2492 77' 110 1.000 7.0, Ox0 VIFx 47.9 135.0 St3 DININGRM c 3247 94' 144 1.000 8.0 Ox0 VIFx 36.4 115.0 st1 FOYER c 3258 881 144 1.000 8.0 Ox0 VIFx 65.8 135.0 st3 KITCHEN c 3331 81 148 1.000 8.0 Ox 0 VIFx 36.4 115.0 st1 LAUNDRY RM c 1425 51 63 1.000 6.0 Ox 0 VIFx 11.0 115.0 st2 LIVINGRM c 4028 119 179 1.000 8.0 Ox0 VIFx 45.2 135.0 st3 M BATH h 2533 108 58 1.000 6.0 Ox0 VIFx 10.2 115.0 st2 M TOILET c 437 17 19 1.000 5.0 Ox0 VIFx 13.0 115.0 st2 MwIC h 2403 102 56 1.000 6.0 Ox0 VIFx 30.8 135.0 st4 MASTER BEDROOM h 3182 136 125 1.000 7.0 Ox0 VIFx 32.1 135.0 st4 MASTER BEDROOM -A h 3182 136 125 1.000 7.0 Ox0 VIFx 29.1 135.0 st4 PANTRY h 776 33 12 1.000 4.0 Ox0 VIFx 34.1 115.0 st1 WIC h 1607 68 23 1.000 5.0 Ox0 VIFx 39.1 115.0 SO Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 541 593 1.000 755 12.0 0 x 0 VinlFlx st1 SO Peak AVF 817 020 1.000 861 14.0 0 x .0 VinlFlx st4 Peak AVF 374 306 1.000 846 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 550 447 1.000 833 11.0 0 x 0 VinlFlx " Wrightsoftm 2021-Feb-25 08:28:20 •µ•• • u.M ,•a •. Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 ..cumnetslWrightsoft WAC%BLANDFORD RESIDENCE.rup Cale = MJ8 Front Door faces: NW Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1367 1367 0 0 0 0 Ox 0 VIFx -�- wrightsoft- 2021-Febr25 08:28:20 . . Right -Suite® Universal 2021 21002 RSU08101 Page 2 ...cumnetslWrightsoft WVACIBLANDFORD RESIDENCE. rup Calc = MJ8 Front Door faces: NW 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA RE Ce�h'L TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERI a MAR ®� 2="' Project Name: BLANDFORD RESIDENCE Builder Name: GEM BUILDERS Street: 4906 BUCHANAN DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce t� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall, be sealed. Rim joists Rim joists shall include the. air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subficor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the tap of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be providedl between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Diping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Diates and walls or ceilin s. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. r 2/25/2021 8:32 AM EnergyGauge® USA'7.0.00 - FlaRes2020 FBC, 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 MAR 0 2 2020 ST. Lucie County, Perrni-; � ENERGY PERFORMANCE LEVEL (EPL) DISPLA ARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 4906 BUCHANAN DRIVE, FORT PIERCE, FL, 1. New construction or ebsting New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=5.0 2200.00 ft2 b. Frame - Wood, Adjacent R=13.0 520.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2369.00 ft2 6. Conditioned floor area (W) 2369 b. N/A R= ft2 7. Windows•" Description i Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.24 358.00 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: AHU CLST R ft2 6 175 SHGC: SHGC=0.15 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 41.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 7.067 ft. Area Weighted Average SHGC: 0.150 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): W ft2 2 a. Electric EF: 0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2369.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 I certify in this based Florida Energy Efficiency Code for Building a features which will be installed (or exceeded) le, a new EPL Display Card will be complbted - - *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Cod Energy Conservation, contact the Florida Building Commission's support staff: C **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not fLR% 2/25/2021 8:32 AM EnergyGauge® OSA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1