HomeMy WebLinkAboutARM Investigations Gen SpecsINCLUDES.
• Two -Line LCD Multilingual Digital EvolutionT""
Controller (English/Spanish/French/Portuguese)
with external viewing window for easy indication Of
generator status and breaker position.
• Capability to be installed with 18" (457mm) of a
building*
• True PowerTM Electrical Technology
• Isochronous Electronic Governor
• Sound Attenuated Enclosure
• Closed Coolant Recovery System
• Smart Battery Charger
• UV/Ozone Resistant Hoses
• -L 1 % Voltage Regulation
• Natural Gas or LP Operation
• 5 Year Limited Warranty
• UL 2200 Listed
GENERAC QD
PROTECTOR® SERIES
Standby Generators
Liquid -Cooled Gaseous Engine
Standby Power Rating
Model RG025 (Aluminurn - Bisque) - 25 kW 60 Hz
Model RG030 (AluminUM - Bisque) - 30 kW 60 Hz
Model RGO3 - e - 36 kVV 60 Hz
Model RG060 (Alurninum - Bisque) - 60 kW 60 Hz
I
C
ll.,cO
'lssmnMed In Ne VSR using
tlomeslic and IerelBn Verb
Note: 25-45 kW units are field convertible between *Only if located away from doors, Meets EPA Emission Regulations
natural gas or liquid propane. 60 kW units are windows, and fresh air intakes, and
unless otherwise directed blocal codes, 25, 30 & 45 kW CA/MA emissions compliant
y
built per fuel requirement and are not convertible. 36 & 60 kW not for sale in CA / MA
Applicable for 25kW and 30kW units only.
FEATURES
0 INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION,
GENERAC'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on
doesn't stop there. Total commitment to component testing, reliability all Generac models. It provides optimized FAST RESPONSE to changing
testing, environmental testing, destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
to applicable CSA, NEMA, EGSA, and other standards, allows you to electronically torque -matching the surge loads to the engine. Digital
choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at ±1%.
systems will provide superior performance.
O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
c� TEST CRITERIA; engine to the smallest electronic component.
PROTOTYPE TESTED NEMA M131-22 EVALUATION 0 GENERAC TRANSFER SWITCHES, Long life and reliability are
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
ri
i2 ISO
900 1:
Zooa
GENERAC*
25 • 30 • 36 • 45 • 60 kW application & engineering data
Type
Synchronous
Rotor Insulation Class
H
Stator Insulation Class
H
Telephone Interference Factor (TIF)
<50
Alternator Output Leads 1-Phase
4 wire
Alternator Output Leads 3-Phase
6 wire
Bearings
Sealed Ball
Coupling
Flexible Disc
Excitation System
Direct
VOLTAGE REGULATION
Type Electronic
Sensing Single Phase
Regulation -r 1%
GOVERNOR SPECIFICATIONS
Type Electronic
Frequency Regulation Isochronous
Steady State Regulation - 0,25%
ELECTRICAL . SYST E114
Battery Charge Alternator
12 Volt 15 Amp - 25 & 30 kW
12 Volt 30 Amp - 36, 45 & 60 kW
Static Battery Charger
2 Amp
Recommended Battery (battery not included)
Group 26, 525CCA
System Voltage
12 Volts
GENERATOR FEATURES
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Class H insulation is NEMA rated
All models fully prototyped tested
ENCLOSURE FEATURES
Ensures protection against mother nature.
Aluminum weather
Electrostatically applied textured epoxy paint for added
protective enclosure
durability.
Enclosed critical grade
Quiet, critical grade muffler is mounted inside the unit
muffler
to prevent injuries.
Small, compact, attractive
Makes for an easy, eye appealing installation.
SAE
Sound attenuated enclosure ensures quiet operation.
(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)
Make
Generac
Model
In -line
Cylinders
4
Displacement (Liters)
1.5
Bore (in/mm)
3.05/77.4
Stroke (in/mm)
3.13/79.5
Compression Ratio
11:1
Intake Air System
Naturally Aspirated
Lifter Type
Hydraulic
Make
Generac
Model
In -line
Cylinders
4
Displacement (Liters)
2.4
Bore (in/mm)
3.41/86.5
Stroke (in/mm)
3.94/100
Compression Ratio
9.5:1
Intake Air System
Naturally Aspirated (36 & 45 kW) or
Turbocharged/Aftercooled (60 kW)
Lifter Type
Hydraulic
ENGINE LUBRICATION SYSTEM
Oil Pump Type Gear
Oil Filter Type Full flow spin -on cartridge
4/3.8 - 25, 30, 36 & 45 kW
Crankcase Capacity (qVI) 5.25/4.96 - 60 kW
Type
Closed
Water Pump
Belt driven
2484 - 25 & 30 kW
Fan Speed (rpm)
1865 - 36 & 45 kW
2100 - 60 kW
17.7/449.6 (25 & 30 kW) or
Fan Diameter (in/mm)
22/558.8 (36, 45 & 60 kW)
Pusher (25 & 30 kW) or
Fan Mode
Puller (36, 45 & 60 kW)
[ IlfflIEAW314 {#1
Fuel Type
Natural gas, propane vapor
Carburetor
Down Draft
Secondary Fuel Regulator
Standard
Fuel Shut Off Solenoid
Standard
Operating Fuel Pressure
5-14" water column/9-26 mm HG
LP Fuel Pressure
11 -14" Water Column
NG Fuel Pressure
5 -14" Water Column
GENERAC'
25 • 30 • 36 • 45 a 60 kW operating data
GENERATOR OUTPUT VOLTAGEAW - 60 Hz
UUI i Pr n..._
1201240 V, 10, 1.0 pf
25
_
104
�.. •N{. MGJ
25
nillp nai. Lids Gts zirze (Both)
104 125
RG025
120/208 V, 30, 0.8 pf
25
87
25
87
100
120/240 V, 30, 0.8 pf
25
75
25
75
90
120/240 V, 10, 1.0 pf
30
125
30
125
150
RG030
120/208 V, 30, 0.8 pf
30
104
30
104
125
120/240 V, 30, 0.8 of
30
90
30
90
100
1201240 V, 10, 1.0 pf
36
150
36
150
175
RG036
120/208 V, 30, 0.8 pf
36
125
36
125
150
120/240 V, 30, 0.8 pf
36
108
36
108
125
277/480 V, 30, 0.8 pf
36
54
36
54
188
60
1201240 V, 10, 1.0 pf
45
188
45
200
120/208 V, 30, 0.8 pf
45
156
45
156
175
120/240 V, 30, 0.8 pf
45
135
45
135
150
277/480 V, 30, 0.8 pf
45
68
45
68
80
1201240 V, 10, 1,0 pf
60
250
60
250
300
RG060
120/208 V, 30, 0.8 pf
60
208
60
208
250
120/240 V, 30, 0.8 pf
60
180
60
180
200
277/480 V, 30, 0.8 of
60
90
60 1
90
100
Voltage Dip @ < .4 pf
1 Go% ono/
120/240 V, 10
65
170
RG025
120/208 V, 30
80
130
1201240 V, 30
69
112
120/240 V, 10
75
180
RG030
1201208 V, 30
96
155
120/240 V, 30
83
134
120/240 V, 10
105
240
RG036
120/208 V, 30
44
130
120/240 V, 30
38
115
2771480 V, 30
20
60
1201240 V, 10
105
240
Q4
120/208 V, 30
44
130
i
1201240 V, 30
38
115
277/480 V, 30
20
60
1201240 V, 10
140
320
RG060
1201208 V, 30
70
210
120/240 V, 30
61
182
277/480 V, 30
30
91
Note: Fuel pipe must be sized for full load.
For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG)
For megajoule content, multiply m3/hr x 93.15 (t_P) or m3/hr x 37.26 (NG)
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and
SCAQMD permitting purposes.
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There
is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.
ENGINE FUEL CONSUMPTION
Natural Gas Propane
(W/h6 /m3 /h,l /not/h.1 111-1
Exercise cycle
60
1.7
0.7
2.5
24
25% of rated load
220
6.3
2.9
9.1
88
RG025
50% of rated load
297
8.4
3.3
12.3
119
75% of rated load
362
10.3
4
15
145
100% of rated load
430
12.2
4.7
17.8
172
Exercise cycle
60
1.7
0.7
2.5
24
25% of rated load
240
6.8
2.6
10
96
RG030
50% of rated load
320
9.1
3.5
13.3
128
75% of rated load
400
11.4
4.4
16.6
160
100% of rated load
492
14
5.4
20.4
197
Exercise cycle
65
1.8
0.7
2.6
25
25% of rated load
210
6
2.3
8.6
83
RG036
50% of rated load
380
10.8
4.2
15.7
151
75% of rated load
545
15.5
5.9
22.4
216
100% of rated load
730
20.7
8
30.1
290
Exercise cycle
65
1.8
0.7
2.6
25
25% of rated load
210
6
2.3
8.6
83
5-i
50% of rated load
380
10.8
4.2
15.7
151
75% of rated load
545
15.5
5.9
22.4
216
100% of rated load
730
20.7
8
30.1
290
Exercise cycle
123
3.5
1.34
5.1
49.3
25% of rated load
267
7.6
2.7
10.5
101
RG060
50% of rated load
483
13.7
5
19
183
75% of rated load
672
19.1
7
26.5
255
100% of rated load
862
24.5
9
33.9
327
GENERAC
25 • 30 • 36 • 45 -, 60 kW operating data
ENGINE COOLING
25 kW 30 kW 36 kW IhMb 60 kW
Air flow (inlet air including alternator and combustion air in cfm/cmm)
2490/70.5
2490/70.5
2725/77.2
2725/77.2
3280/92.9
System coolant capacity (gal/liters)
2/7.6
2/7.6
2.5/9.5
2.5/9.5
2.5/9.5
Heat rejection to coolant (BTU per hr/MJ per hr)
112,000/118.2
135,000/142.4
193,000/203.6
193,000/203.6
270,000/284.9
Maximum operation air temperature on radiator (°C/°F)
60/140
Maximum ambient temperature (°C/°F)
50/122
COMBUSTION REQUIREMENTS
Flow at rated power (cfm/cmm) 62/1.8 72/2 144/4.1 144/4.1 180/5.1
Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode*
59
1 59
61
1 61
F:]75
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load"
72
73
70
73
2
*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be nigher depending on insrauauuu paidffieL s.
EXHAUST
Exhaust flow at rated output (cfm/cmm)
203/5.7
237/6.7
1 300/8.5
420/11.9
494/14
Exhaust temperature at muffler outlet (°C/°F)
593/1100
610/1130
579/1075
593/1100
566/1050
Rated Synchronous rpm I 3600
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration................................................................................................... 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F
Altitude Deration (25, 30, 36 & 45 kW)...............................................................................I % for every 100 m above 183 m or 3% for every 1000 ft above 600 ft
Altitude Deration (60 kW)................................................................................................ 1 % for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
CONTROLLER FEATURES
Two -Line Plain Text LCD Display
......Simple user interface for ease of operation.
Mode Switch: Auto..............................................................................................................................................Automatic
Start on Utility failure. 7 day exerciser
......... .......................... I........ I .........................................
Off
Stops unit. Power is removed. Control and charger still operate.
.....................................
Manual
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
.........................................................................................
Programmable start delay between 10-30 seconds................................................................................................................................................10
sec Standard
Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)
Engine Start Sequence.....................................................................................................................
5 sec
EngineWarm-up.....................................................................................................................................................................................................................1
min
EngineCool-Down..................................................................................................................................................................................................................
Starter Lock-out
cannot re-engage until 5 sec after engine has stopped.
................................................................................................................................Starter
SmartBattery Charger........................................................................................................................................................................................................Standard
Under Voltage Protection
Standard
Automatic Voltage Regulation with Over and ................................................................................................................................
Standard
AutomaticLow Oil Pressure Shutdown..............................................................................................................................................................................
Standard, 72 Hz
OverspeedShutdown..............................................................................................................................................................................................
HighTemperature Shutdown...............................................................................................................................................................................................Standard
OvercrankProtection..........................................................................................................................................................................................................Standard
Standard
SafetyFused......................................................................................................................................................................................................................
Failureto Transfer Protection..............................................................................................................................................................................................Standard
Standard
LowBattery Protection........................................................................................................................................................................................................
Standard
50 Event Run Log...............................................................................................................................................................................................................
Exerciser
FutureSet Capable ..............................................................................................................................................................................................Standard
Standard
IncorrectWiring Protection.................................................................................................................................................................................................
InternalFault Protection.....................................................................................................................................................................................................Standard
External Fault Capability
..................................................................Standard
Common
GovernorFailure Protection................................................................................................................................................................................................Standard
25.30*36. 45.60kW
GENERAC®
WWWWMNNNM
available accessories
Model # Product Description
Generac's Mobile Link allows you to check the status of your generator from
anywhere that you have access to an Internet connection from a PC or with
G006463-4 Mobile Link'" any smart device. You will even be notified when a change in the generator's
status occurs via e-mail or text message. Note: Harness Adapter Kit required.
Available in the U,S. only.
G006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid -cooled units compatible with
Mobile LinkT".
G006175-0 - 25 & 30 kW If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit
G005630-1 - 36, 45 & 60 kW Cold Weather Kit to maintain optimal battery temperature. Kit consists of battery warmer with
thermostat built into the wrap.
G006174-0 - 25 & 30 kW Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for
G005616-0 - 36, 45 & 60 kW Weather Kit extended periods of time. For liquid cooled units only.
G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris.
If the generator enclosure is scratched or damaged, it is important to touch-up
G005703-0 - Bisque Paint Kit the paint to protect from future corrosion. The paint kit includes the necessary
paint to properly maintain or touch-up a generator enclosure.
G006176-0 - 25 & 30 kW
G006172-0 - 36 & 45 kW Scheduled The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware necessary
G006171-0 - 60 kW Maintenance Kit to perform complete maintenance on Generac liquid -cooled generators.
G006664-0 Local Wireless Completely wireless and battery powered, Generac's wireless remote monitor
Monitor provides you with instant status information without ever going outside.
G006665-0 Wireless Remote Recommended for use with the Wireless Remote on units up to 60 kW, required
Extension Harness for use on units 70 kW or greater.
Smart Management Modules are used in conjunction with the Automatic
G006873-0 Smart Management Transfer Switch to increase its power management capabilities. It provides
Module (50 Amps) additional power management flexibility not found in any other power
management system.
G006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of
an emergency.
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the
Wi-Fi LP Fuel Level connected LP fuel tank. Monitoring the LP tank's fuel level is an important step
G007005-0 in making sure your generator is ready to run during an unexpected power
Monitor 9 p
failure. Status alerts are available through a free application to notify when your
LP tank is in need of a refill.
GENERACO
25 & 30 kW installation layout
Drawing #OK8420-B (1 of 2)
m m0
O
i Q
Q U
¢ U
o wx�3mzo �
¢z�w m�a
OK 6 ZQ NLL Fm
0 o aoo�p m moos
OR=
3 o�ira �w oF�o��wyy aF��z
�tW�w mQ �oNw�wii� rc�Naxw
o �pQ; pwwo iNLL~ALL
S>LLowo-mow
N �
d' ZZ UW�iUm>U'U •rK h
m wup�a Z Na QO a _ Euz ��xO�m
urc mrcoomFF a�Ur3a
na=.w~U
S� mamrc o wx 2.zmaw
Syll
poQ�o aw
p Sz�a morxo'� c� amwLL3aomw
OJU
O OO�i .rw�O�oap3u�ia�0o00�mu
w OOiOWUwiU�wi�ZpU�x�mKOmmaWO
_ON2pKNU'WmZ�wafvlamKOwa I-
w5� �co>�zoxr<a<nowi�_4am�xoNw�m�wa
�x1-d K WU > OFi LL�Eiuy
oNucdu�za�xa ion�moo 3zmox�
,U�?LLzzoaLL c�oiLLLLONwm of om_fo
m ump�V ��i���w�oomom
Ox"�x�pQzzN¢wsW>
z mzQ�osg,iwziUwwwor
vPnrmcF'm
fw
o��Ja
UKxZ�m-
aQO
WttU
Ow
wp2
mao
�) �! I��1��
w
two
yZU
>
w Oo
Ym viWw
z z 2
mJ
KO
am
3
im
o
aom
o�y
¢ix
L.
a-aUQ
KOm
�y
■
mm
»rc�
mOo
mw..
o
p
>ti
OQ
E�
m a6
p
rco
Oj
i0 W
oW
u n ULL
v_ w
Z1-
Iz
S
S
v
rc
ii ,Y F
ULLO
w
ZO z 4
W �•
UOLL
a o i
'ag
tt
o$
m
�mt=
NO w
O
¢m ¢zWZF-
Ow W�(Uj03Y
G'
mZZwwU wrn
�f.wWZW mQI-r
�w!zdOw 1I2-yOi
�W
m90
mmw 0x m
�30wd
GENERAC"
25&30kW
w�
O z
�m
o�
Z0
Z -
ZO
O0 U
W
V Z
F Z
O
O
>a
Omw
O
<U Id
so
O
¢Z
aw
�aYa
�W
FK
N GI
O�
Z_
. U
installation layout"
Drawing #OK8420-B (2 of 2)
GENERACO
Drawing #OK8636-B (1 of 2)
U
LL W
F
z0LLg0
0000C�
f LL'NW W
U wLLLLZ
¢a7Cfw
OW O z �
Q
H U
W U I- J Z Z Ld
W O 'n ILm R'
�ozW� 0oz o wvg o
�Owlo w p0� rt� m `nr3 U
aH7LL O Zx^x3 z_O c9 t=w¢ z
N W Z U LL' Q Z 6 J Z H LL -.. W
OX-4O W
a.
z�wY O Oa00zz WE 2
W. zw�z
¢
3if0za o zoiz>o - ¢zoz
"oO°¢ OON OOOFp WW8 m "POOz WU'
g r�oJ J� mFN�p�t7w Z.
_m ZwU3 z �¢ JoW��a?O OW -W W,
�xw?¢ 2¢N� <N22WNa¢� =ZLLzo
nWj3� W Np �ZQZ LL,ZZ OJ�3U7 N=Uj�
getLL. QfA Uw�aU�U' O DOH
avoi¢o d���ci
wa0Za WWaj p=�QmQJ�NW�NpW
LL' WJmO 40W OUpaWm W �Z W W lull)'
�
z�ama W3U)K
KO�
zWUzc xLL,1, zap m0
°i?oR� m°.-��oao3N�Zo�a���LLa
❑zirzvi~W�OpFmFpm=aOd3LLz�o0
O ��Z z 8UxxZcn w ZO W 4y�v0i w w,-- Q�
Z LL'OQp�N��f¢ZUZF�OWOQW�NOWZ
��Z2MJU000Q¢OwpsW ZU) W7�KJQ
�H W FQQJFm W �J UZUQZp Yi JN W"G �21Wia
W W LL U W O a LL W x 7 H O Q LLKLL LL O W (7 a p O F CL
� p 72ZOJ UZ J U 07 H J J J d p g Z Z Z j 0 H N LL
?��IaLLOQOQdQrnUth ¢KO =N m7WU�OXULU WOWNOW.FZJUOn�omKQ�-a
N Q�
y
w
N y
rc rc
y N
=
rc �
0 0 0
W N
w
w
N F
W N
y F
W W
w
0 O
tll
O
W K
o
w
m¢ w
RR
W U
w>��awmm�ax
w
w
wa W
YLLw>
ua.
k z
m
'o o
z
w a
a
Sd
o z
O
�on
a
z Z Z
W
� W
U
Z W
OUP
W 0 Z
UO�
zWN
way
Lea
Y�
mw
~O
cn z
m W
UN
U
N O W
K
O
J Q
W
W Q
W
W
O
installation layout
U
z
O
N
�� ro z
wZ
OW UOtAQIx-
QU
z a lW- WJQ C! SS W
W W O Z m W~
W O
WOW OwWQZ
U W z� U W
Uw =¢na.m�Wm
H
O 3 w
�J 4�
W W
ro
�ro W �
�O
QJQ F'
—roc K(7
Ox
Z Z
Z
OZ
()a
w0
Zz
z0
0 ,_
U
U'z
J0
OU
>�
w
Op
QU
(7 z
= J
09
Q z)
W w
Z
Q n%
O
N
GENERAC®
inst
allation layout
Drawing #OK8636-B (2 of 2)
3
w
w
0
W
w
J
60 kW
Drawing #OL2090-B (1 of 2)
OZ 0 Z ❑
J 9 a w w
MSUhJLLI
Z Z W in (a OJO d'
St=7 QW� L °zN p W g r=i)
�❑ W W" W,
LL (~j�K> 23 NH¢ OJ
d W, O W" ° Z ^xx> z O C5 F- W Q Z
N F a= W Z J Z r LL = W fn W
X W2�x OO a�pW- fi <::
LU of
.03 z a. DaoF
❑6O �¢zOOzz m w°��
❑ z
3o�za o zo=z>o ¢zoBz
a�°oN °ai °oO�Wo Q _ooUw
o �a ❑w a~o�U x < wo
,LL.o- �° Q-IRQ.-NU WPHZI
MzWUW z �a JO���a?Q °"WWr
�pc7a �' O wo ❑>W❑pOZLL �(nKF-
�xWZQ F-Qyf aNNWNKaLL' a2LLO�
2
N3FWn ilaz ��QZZo 3'm �2. W-
WO❑ LL J W< K Q 2 9 U W� Q U o zz p 7 F. x 0
a J y F❑ O W U K Z Q U} W❑� Z �� U D Z
F,]OZ r LL. Za> ❑U0� FQJ ❑p fA W `L v1 pQ W
W tlJ�Wtl1 Y?i W�..J}�FN�=0 r2 WF- W�+-WN
UpQ~� W�O�?i ZwZ U' �LLIJ F-En JOU
05Zjd %0O-7ID 00Z�ZWW��NWLL�Fa-Z
p'QU
ozzFzn=w�oJo°m�o�=Q°�3LLz�oo
o0°o�zo��=zn°owyayOQQ�N�O°amWaW
Z N r°
2F-WFg6d�Mgw8Zo>ZOzf2vaiw,zi¢LLa
3J ExLL
W LL Z Z W a °-_ W 2 a a OU Q LL 0 O W m a
W UpU W paU❑~20
7 J Q J0g J ZZZO pF-p y LL
QNU Law
f_N WO(~b=?� W O� W 7(p NW W~xO
WIXM
F' RWQZdr OOWOWTTzWWmW,m7mNo QWK
z �KNaaU� �i- iris red rn
0
w. o'
WW
WW
W W
O W
z
K
i O z
w
(W/1
o 0F
N
LL
J
w
W O
V E
z V
w%Owozrc_w
zLL
W
w m
z
E z
k Q
W 0
N
�
O a Z
o
o
K
a
�y
Q Z
Z Z
Z W
a2
�w
U
LU CL
Z LU
OU
W 0 ZP
UOF
W LU
I a-
wu°_0.
Q
U
r
w0
go0LLN°
200x
wF- W W
U W LL d Z
aa7ww
Ma}
NSF
J
Ui w
of W� z
O W Q °U W a~
JZ� �y C)
LU
} ❑ W
ww0 Oi J w�°
w W W p
F W W r Q Z
(D ZFU W
�mQQOw
w C) v) C%Q LLm J[n
aJa F'
pK(�
W M
�O O
�z
m
, W
U N
K
Q
Q
U
OO�w
Z
CL
w?NO
U
°°wU
W N Q W
O Wzw
W UQW
w Q2 LL'
W
a
GENERACO
installation layout
O
Z
Za
O�
U°
U
Z W
Z Q
O2
C)
W LL
?r
Ja
J Z
W
7
tL M
W
W
U)
LL
W
J
GENERACO
60 kW
ow >
W ¢a
w o=
pp .3
(7 Z
JO
00
w
0O y
F
QU
N
Q
J
W
O
O?
�w
�z
<o
aw
� QYQ
7W
F�
ym
F
W C)
O�
?U
oa
(V
installation layout
Drawing #01-2090-8 (2 of 2)
GENERAC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin OL0037SBY--L 9/25/17