ile Home Inspection Report
All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone 11 certified.
Owner:
(Print or
Address:.
Year / Manufacturer _
i
Width
C = In Compliance N = Not in
1. Smoke Detector: Installed_
—C� 2. Electrical System Checked
3. Distribution Panel: Missing
4. Electrical Fixtures: Missing
ImDroD(
GFCI
5. Electrical Ground: Chassis _
Revised N9/05
c C L Date: /0 0? 7 20 cZ O
'pe) 16H L.AKE5
Pi �ECGE r—L— v y Cl✓uB Imp
L: tion of orne) -y— (e3 l a a A
R (T Serial HUD Plate # FLAUPOW,
_ Single Double_ Wind Zone
ipliance
Fire Safety / Electrical
Missing
;posed Wiring Other
_Loose Main Missing Breaker Missing
Jnplugged Opening Other
Installed Improperly
Wired Loose Wire
!ceptacles not where required
Main Panel Gas Pipe
Page 1 of 3 FILE C®P*f
0
S
Construction
G 1. Exit Doors Operable: Front Back Other
2. Exit Door Locks: Missing Inoperable
S� 3. Egress windows: Missing Inoperable
C 4. Windows: Broken Glass
Inoperable
5. Screens: Missing Damaged
6. Floor System: Joist
Decking Area Damaged
7. Interior Paneling: Missing
Loose Damaged
C 8. Rodent Proofing: Bottom Board
Pipe openings Other
C 9. Leaks Apparent: Ceiling Doors
Floor Roof
C. 10. Vertical tie -down straps: Missing
Short Damaged
i
11. Structural modifications since manufactured: YES_ NO_V
C-12. Walls: Structurally Unsound i Loose Weather tight _
Plumbing
C 1. Trap: Missing Not connected Other
C 2. Plumbing fixtures: Missing Not installed Not Vented
-jC— 3. Relief Valve: Missing Inoperable Other
C_ 4. Drain Waste and Venting Piping,: Missing Not supported
Clean outs Use of fittings Not capped
Heating and Air Conditioning
1. Heating Appliances: Missing Not Connected Other.
2. Deleted Heating/AC system: Not installed Other
_ 3. Thermostat: Missing i Inoperable
G 4. Air registers: Missing Inoperable
G 5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
G 6. Gas furnace Water heater vent: Missing
7. Return Air: To Furnace . To A/C
_& _ 8. Range: Vent Hood
Loose
From rooms
_ 9. Gas Valve: Accessible Installed improperly
10. Gas lines: Not capped Not supported Kinked
Not bonded
Summary
1. Is subject structure found to be fifty'(50%) or more damaged or deteriorated? YES NO�_
2. Willa remodeling permit be required? YES NO
The provisions of the repair and remodelling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE A LOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
THEIR SEAL.
Date inspected: 7 W
Inspected By: 5—M VJ f • ��
Slgn ture mquinedl21
Phone Number: (r r —) 3 (�
License # 3 � 3` b
Page 3 of 3
Englne�a?I Dad
rs
STEVFN G. WOOD, P.E.
FL LIZCENSE 34398
960 SULTAN DR
FORT ST LUCYE9 FL