Loading...
HomeMy WebLinkAboutMobile Home Inspection ReportI a t Lucie County Building & Zoning 300 Virginia Avenue t Pierce. FL 34982 ile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone 11 certified. Owner: (Print or Address:. Year / Manufacturer _ i Width C = In Compliance N = Not in 1. Smoke Detector: Installed_ —C� 2. Electrical System Checked 3. Distribution Panel: Missing 4. Electrical Fixtures: Missing ImDroD( GFCI 5. Electrical Ground: Chassis _ Revised N9/05 c C L Date: /0 0? 7 20 cZ O 'pe) 16H L.AKE5 Pi �ECGE r—L— v y Cl✓uB Imp L: tion of orne) -y— (e3 l a a A R (T Serial HUD Plate # FLAUPOW, _ Single Double_ Wind Zone ipliance Fire Safety / Electrical Missing ;posed Wiring Other _Loose Main Missing Breaker Missing Jnplugged Opening Other Installed Improperly Wired Loose Wire !ceptacles not where required Main Panel Gas Pipe Page 1 of 3 FILE C®P*f 0 S Construction G 1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable S� 3. Egress windows: Missing Inoperable C 4. Windows: Broken Glass Inoperable 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing Loose Damaged C 8. Rodent Proofing: Bottom Board Pipe openings Other C 9. Leaks Apparent: Ceiling Doors Floor Roof C. 10. Vertical tie -down straps: Missing Short Damaged i 11. Structural modifications since manufactured: YES_ NO_V C-12. Walls: Structurally Unsound i Loose Weather tight _ Plumbing C 1. Trap: Missing Not connected Other C 2. Plumbing fixtures: Missing Not installed Not Vented -jC— 3. Relief Valve: Missing Inoperable Other C_ 4. Drain Waste and Venting Piping,: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected Other. 2. Deleted Heating/AC system: Not installed Other _ 3. Thermostat: Missing i Inoperable G 4. Air registers: Missing Inoperable G 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 G 6. Gas furnace Water heater vent: Missing 7. Return Air: To Furnace . To A/C _& _ 8. Range: Vent Hood Loose From rooms _ 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty'(50%) or more damaged or deteriorated? YES NO�_ 2. Willa remodeling permit be required? YES NO The provisions of the repair and remodelling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE A LOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected: 7 W Inspected By: 5—M VJ f • �� Slgn ture mquinedl21 Phone Number: (r r —) 3 (� License # 3 � 3` b Page 3 of 3 Englne�a?I Dad rs STEVFN G. WOOD, P.E. FL LIZCENSE 34398 960 SULTAN DR FORT ST LUCYE9 FL