HomeMy WebLinkAboutAPPROVED Plans 2021.04.13 FINAL PG (3)A Custom Pool Designed Especially For:
E-1
A Custom Pool Designed Especially For:
E-1 DRAFTED BY: G.S.M.3/3/2021
IF SIGNED DIGITALLY ABOVE,
PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON
ANY ELECTRONIC COPIES
3/3/2021
IF SIGNED DIGITALLY ABOVE,
PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON
ANY ELECTRONIC COPIES
IF THERE IS A DIGITAL SIGNATURE
ON THE FRONT/FIRST PAGE OF
THIS FILE, THIS SHEET IS PART OF
A DIGITALLY SIGNED FILE AND
DOES NOT REQUIRE A SEPARATE
DIGITAL SIGNATURE ON THIS
SHEET MARKHAM SERVICES, INC. (PA 33018) WAYNE MARKHAM BENNETT1820 NE JENSEN BEACH BLVD #685, JENSEN BEACH, FL 34957-7212PHONE # 954-818-3825 E-MAIL wayne@wmb-pe.com3/3/2021
IF SIGNED DIGITALLY ABOVE,
PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON
ANY ELECTRONIC COPIES
IF THERE IS A DIGITAL SIGNATURE
ON THE FRONT/FIRST PAGE OF
THIS FILE, THIS SHEET IS PART OF
A DIGITALLY SIGNED FILE AND
DOES NOT REQUIRE A SEPARATE
DIGITAL SIGNATURE ON THIS
SHEET MARKHAM SERVICES, INC. (PA 33018) WAYNE MARKHAM BENNETT1820 NE JENSEN BEACH BLVD #685, JENSEN BEACH, FL 34957-7212PHONE # 954-818-3825 E-MAIL wayne@wmb-pe.comPOOL LIGHT U.L.
APPROVED
POOL STEEL
LOW VOTLAGE NICHELESS
LIGHT
1 ½”" PVC CONDUIT
LIGHT NICHE DETAIL
FROM 12V TRANSFORMER
N.T.S.
4" MIN. FROM WATER
LEVEL TO TOP OF LENS
POOL LIGHT U.L.
APPROVED
POOL STEEL
LOW VOTLAGE NICHELESS
LIGHT
1 ½”" PVC CONDUIT
LIGHT NICHE DETAIL
FROM 12V TRANSFORMER
N.T.S.
4" MIN. FROM WATER
LEVEL TO TOP OF LENS
NOTE: BOND WIRE TO BE SECURED
TO STEEL WITH APPROVED CLAMP.
TO BE ENCASED IN DECK SLAB OR CONCRETE BOX
PROVIDING MIN.
3" OF COVER AROUND CLAMP
POOL BOND SCHEMATIC
N.T.S.
POOL BOND SCHEMATIC
N.T.S.
TO POOL EQUIPMENT
#8 BARE COPPER WIRE FOR 360 °
WITH 4 JUMPERS TO BE 18" TO 24"
FROM WATERS EDGEWATER LINE
3"
N.T.S.
PER FLORIDA BUILDING CODE
ADAPTION OF N.E.C. 2014 SEC 680.26
EQUIPOTENTIAL
BONDING GRID DETAIL
#8 BARE COPPER WIRE FOR 360 °
WITH 4 JUMPERS TO BE 18" TO 24"
FROM WATERS EDGEWATER LINE
3"
N.T.S.
PER FLORIDA BUILDING CODE
ADAPTION OF N.E.C. 2014 SEC 680.26
EQUIPOTENTIAL
BONDING GRID DETAIL
NOTE: PROVIDE CONTINOUS
SINGLE #8 COOPER BONDED
IN FOUR POINTS (360 ) AROUND
POOL & SPA AS PER N.E.C.
2014 ART. 680.26 (B) & (C)
o
NOTE: PROVIDE CONTINOUS
SINGLE #8 COOPER BONDED
IN FOUR POINTS (360 ) AROUND
POOL & SPA AS PER N.E.C.
2014 ART. 680.26 (B) & (C)
o
NOTE: BOND WIRE TO BE SECURED
TO STEEL WITH APPROVED CLAMP.
TO BE ENCASED IN DECK SLAB OR CONCRETE BOX
PROVIDING MIN.
3" OF COVER AROUND CLAMP
POOL BOND SCHEMATIC
N.T.S.
TO POOL EQUIPMENT
#8 BARE COPPER WIRE FOR 360 °
WITH 4 JUMPERS TO BE 18" TO 24"
FROM WATERS EDGEWATER LINE
3"
N.T.S.
PER FLORIDA BUILDING CODE
ADAPTION OF N.E.C. 2014 SEC 680.26
EQUIPOTENTIAL
BONDING GRID DETAIL
NOTE: PROVIDE CONTINOUS
SINGLE #8 COOPER BONDED
IN FOUR POINTS (360 ) AROUND
POOL & SPA AS PER N.E.C.
2014 ART. 680.26 (B) & (C)
o
ELECTRICAL CODE and NOTES:
National Electrical Code (NEC), NFPA 70 - 2017 shall specifically govern, including Article
680 Swimming Pools, Fountains, and Similar Installations
Article 430.32 Continuous -Duty Motors. Each motor used in continues duty application
shall be protected against overload
Article 680.6 Grounding. Electrical equipment shall be grounded in accordance with Parts V,
VI and VII of Article 250 and connected by wiring methods of Chapter 3, except as modified
by this Article. The following equipment shall be grounded: (1) Through -wall lighting
assemblies and underwater luminaires, other than those low -voltage lighting products
listed for the application without a grounding conductor (2) All electrical equipment located
within 1.5 m (5 ft) of the inside wall of the specified body of water (3) All electrical
equipment associated with the recirculating system of the specified body of water (4)
Junction boxes (5) Transformer and power supply enclosures (6) Ground -fault circuit
interrupters (7) Panelboards that are not part of the service equipment and that supply any
electrical equipment associated with the body of water
Article 680.9 Overhead Conductor Clearances. Overhead conductors shall meet the
clearance requirements in this section. Where a minimum clearance from the water level is
given, the measurement shall be taken from the maximum water level of the specified body
of water. (A) Power. With respect to service -drop conductors, overhead service conductors,
and open overhead wiring, swimming pool and similar installations shall comply with the
minimum clearances given in Table 680.9(A) and illustrated in Figure 680.9(A). (B)
Communications Systems. Communications, radio, and television coaxial cables within the
scope of Articles 800 to 820 shall be permitted at a height of not less than 3.0 m (10 ft)
above swimming and wading pools, diving structures, and observation stands, towers, or
platforms. (C) Network-Powered Broadband Communications Systems. The minimum
clearances for overhead network-powered broadband communications systems conductors
from pools or fountains shall comply with the provisions in Table 680.9(A) for conductors
operating at 0 to 750 volts to ground.
Article 680.10 Electric Pool Water Heaters. All electric pool water heaters shall have the
heating elements subdivided into loads not exceeding 48 amperes and protected at not
over 60 amperes. The ampacity of the branch -circuit conductors and the rating or setting of
overcurrent protective devices shall not be less than 125 percent of the total nameplate -
rated load.
Article 680.11 Underground Wiring Location . Underground wiring shall be permitted
where installed in rigid metal conduit, intermediate metal conduit, rigid polyvinyl chloride
conduit, reinforced thermosetting resin conduit, or Type MC cable, suitable for the
conditions subject to that location. Underground wiring shall not be permitted under the
pool unless this wiring is necessary to supply pool equipment permitted by this article.
Minimum cover depths shall be as given in Table 300.5.
Article 680.22 Lighting, Receptacles, and Equipment. (A) Receptacles. (1) Required
Receptacle, Location. Where a permanently installed pool is installed, no fewer than one
125-volt, 15- or 20-ampere receptacle on a general -purpose branch circuit shall be located
not less than 1.83 m (6 ft) from, and not more than 6.0 m (20 ft) from, the inside wall of the
pool. This receptacle shall be located not more than 2.0 m (6 ft 6 in.) above the floor,
platform, or grade level serving the pool. (2) Circulation and Sanitation System, Location.
Receptacles that provide power for water -pump motors or for other loads directly related
to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the
inside walls of the pool. These receptacles shall have GFCI protection and be of
the grounding type. (3) Other Receptacles, Location. Other receptacles shall be not less than
1.83 m (6 ft) from the inside walls of a pool. (4) GFCI Protection. All 15 - and 20-ampere,
single-phase, 125-volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool
shall be protected by a ground-fault circuit interrupter.
DESIGNER
BLAZER, LORI
1200 PARKLAND BLVD
FORT PIERCE, FL 34982
GEORGE GALISZEWSKI
BLAZER, LORI
1200 PARKLAND BLVD
FORT PIERCE, FL 34982
GEORGE GALISZEWSKI
¾” PVC CONDUIT W/ 2 #6 HOT,
1 #10 GRND. 1 #10 NEUTRAL
EXISTING PANEL 2P
60A BREAKER
FEEDING POOL
WP GFI 6' TO 20' FROM
WATER
48" MIN.
(2) 12V 20W NICHELESS
L.E.D. LIGHTS (POOL)
1" NON-CORROSIVE
CONDUIT
2 #12,
1 #12
GRND.
(1) JUNCTION BOX
ELECTRICAL RISER DIAGRAMBELOW WATERN.T.S.
EXISTING
METER
F.P.L.
POOL
DECK
LEVEL
8" MIN.4"-6" MIN.POOL
PANEL
SALT CHLORINATOR 2 #12, 1 #12 GRND.
HEAT PUMP 2 #6, 1 #10 GRND.
POOL PUMP 3 #12, 1 #12 GRND. GFCI PROTECTED
1. IN POOL AREA GROUND ALL BOXES, RAILS, LIGHT, MOTOR ECT WITH
#8 BARE COPPER WIRE
2. ALL ELECTRICLA TO COMPLY WITH 2014 NATIONAL ELECTRICAL
CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY
AT POINT OF CONNECTION
3. #3 - #12 THHN CU WITIN ½” MIN. CONDUIT FOR POOL LIGHT(S).
4. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B).
5. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL – BY
OTHERS.
6. PROVIDE W.P.G.F.C.I. OUTLET 6' MIN - 20' MAX FROM WATER’S EDGE.
7. APPLY PERIMETER SURFACE AS PER FBC E4201.2 EXP 2.2
ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EXISTING SERVICE AND PANEL HAS
ENOUGH CAPACITY TO ACCOMMODATE THE ADDED POOL EQUIPMENT LOAD PER NEC 220.82"
¾” PVC CONDUIT W/ 2 #6 HOT,
1 #10 GRND. 1 #10 NEUTRAL
EXISTING PANEL 2P
60A BREAKER
FEEDING POOL
WP GFI 6' TO 20' FROM
WATER
48" MIN.
(2) 12V 20W NICHELESS
L.E.D. LIGHTS (POOL)
1" NON-CORROSIVE
CONDUIT
2 #12,
1 #12
GRND.
(1) JUNCTION BOX
ELECTRICAL RISER DIAGRAMBELOW WATERN.T.S.
EXISTING
METER
F.P.L.
POOL
DECK
LEVEL
8" MIN.4"-6" MIN.POOL
PANEL
SALT CHLORINATOR 2 #12, 1 #12 GRND.
HEAT PUMP 2 #6, 1 #10 GRND.
POOL PUMP 3 #12, 1 #12 GRND. GFCI PROTECTED
1. IN POOL AREA GROUND ALL BOXES, RAILS, LIGHT, MOTOR ECT WITH
#8 BARE COPPER WIRE
2. ALL ELECTRICLA TO COMPLY WITH 2014 NATIONAL ELECTRICAL
CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY
AT POINT OF CONNECTION
3. #3 - #12 THHN CU WITIN ½” MIN. CONDUIT FOR POOL LIGHT(S).
4. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B).
5. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL – BY
OTHERS.
6. PROVIDE W.P.G.F.C.I. OUTLET 6' MIN - 20' MAX FROM WATER’S EDGE.
7. APPLY PERIMETER SURFACE AS PER FBC E4201.2 EXP 2.2
ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EXISTING SERVICE AND PANEL HAS
ENOUGH CAPACITY TO ACCOMMODATE THE ADDED POOL EQUIPMENT LOAD PER NEC 220.82"