Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOF DECKi t ] �i a s � N :. •. �.,�� wr�`r ut<- to a"r,'Fht�r •a�#y'{,.dar�l�f"�'�%*``��'u+�s •<` y g g Home ': tn9 rn 11 User Registratlon Hot 7oples Submit Surcharge Stars Pa Fact. Publlatlo f�lnruia• � • ►� _ Product Approval USER: Public User prop_p_J_�u Approval t4enupproval 14enu �> Product ornap�Iiu�tion Search Sy > ii atlan U� > ADPlieatlon Detail FL27402-R2 FL Revision to Application Type 2020 Approved Code Version Application Status Approved Comments Archived kfV ,C•'1 � a�t+Y4�E at 1 �xr ns COMWWs aCIS Sltc Map I UAS i Scarch } RUCEIVED M n R 15 2020 1 5'T. Lucie County, Permitting Product Manufacturer Carports Anywhere Address/Phone/Email Stark S.E. County Road 221 tarke,Fl ��";,a�•��i'���'F?t't� FOR (352)468-1116 P LMN C E badom@carpo,�,a+r �' �� UCE COUNTY Brandie Odom ®;$ Authorized Signature bodom@carportsanyvihere.com BOV Technical Representative Address/Phone/Email Quality Assurance Representative FILE COPY Address/Phone/Email Structural Components Category Roof Deck Subcategory Compliance Method Evaluation Report from a Florida Registered Architect or a licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer, or Architect Name who developed the ]ohnathan Green Evaluation Report PE-88223 Florida License , PRI Construction Materials Technologies, LLC Quality Assurance Entity 06/23/2023 Quality Assurance Contract Expiration Date Brian ]aks, P.E. Validated By Validation Checklist - Hardcopy Received FL27402 R2 COI Letter of Certification -Cavorts Anywhere sea ed.odf Certificate of Independence Referenced Standard and year (of Standard) Standard Year 2005 ASTM E 1592 1992 FM 4471 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D J Force Engineering & Testing 19530 Ranibleivoud Drive 1hnnhlc,'1'e:c:ry 77338 Phone: (281)540-6603 F,1X: (281)540.9966 Websile: w�rw.foreeeny inecria►1iyling.cnm Maximum Design Pressure: -57.3 psf -150.9 psf +39A psf +143.1 psf Fastener Pattern: 6".-3"-6"-3"-6"_3"-6" Fastener Spacing: •new:".. m,.....,., i__,..�-- - `-`-`-'-_— 4'-0" O.C. - - 2'-0" O.C. 4'-0" 0_C. 2'-0" O.0 Code Compliance: Evaluation RepartScape: Performance Standards: Reference Data: t The product described herein has demonstrated compliance with The Florida Building Code 2020, Section 1504.3.2,1504.7. The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2020, as relates to Rule 611320-3. The product described herein has demonstrated compliance with: u ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference FM 4471-92 - Foot Traffic Resistance Test 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST 5328) Report No. 667-0060T-18A-E, 667-0061T-18A-D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-006OT-18F, 667-0061T-18E 3. Certificate of Independence Bylohnathan Green, P.E. (No. 88223) @ Force Engineering & Testing (FBC Organization # ANE ID:12901 i Test Standard Equivalency: 1. The FM 4471-20, Foot Traffic Resistance test standard is equivalent to FM 4471-92. Quality Assurance Entity: 'The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. FL# 27402.1 R2 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BYJOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. t Minimum Slope Range: Installation: Insulation: Roof Panel Fire Classification: Shear Diaphragm: Design Procedure: Force Engineering & Testing 19531► Ranrblesmad Drire Humble. 'remm 77338 1'burtc: 128115411.6603 FAX: (2811340-9966 IYebsile: uutr,foreeenl ineerinllesline.eum Minimum Slope shall comply with Florida Building Code 2020, including section 1507.4.2 and in accordance with Manufacturers recommendations. Forslopes less than 3:12, lap sealant must be used in the panel side laps. Install per manufacturer's recommended details. Manufacturer's approved product (Optional) Fire classification is not part of this acceptance. Shear diaphragm values are outside the scope of this report. Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2020 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2020 Chapter 22 for steel, and Chapter 16 for structural loading. FLO 27402.1 R2 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Force Engineering & Testing 19530 Ilambloyand Drive thimble.'feus 77.3.18 I'lli'llm (231) 540-6693 FAX: (281) 540-9966 Wvkvile: 2ACA. -HIM-P-101'41119 FALTQ4EP PATTERN L-1-2-1 Z___ `-512 -14 . 5/4' ILA( 79 GA. IIAMPT01,4_11Q FASTERIT ZAI - "-G,, LAL N AS ITEM HAS BEEN IGITALLY SIGNED AND EALED BY JOHNATHAN BEEN ON THE DATE )JACENTTO THE SEAL PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FL# 27402.1 R2