Loading...
HomeMy WebLinkAboutBuilding PlansA R C H I T E C T S FRONT ELEVATION SCALE: 3/16"=1'-O" 12 �4 r---FF---TT----I, rr---r,--TT---7-1 rr---TT--r-I--TT----I-T----rr---TT--F-1---,1----7-r----rT---,-T---7 I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II it II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II i---rr---tt----I I----rr---r-I--tt---1 1----rr---tt--r-I--tt----l-r----rr---tt--r1---1 1----rr---tt----1-1-� I 1---1 r--- I t----1 1----I 1---1--1--rtt---11----I r---rtt--r -I-- rt--- y 1----1-1----rt7--1--1----1 1----1 1----7 7----1-1--- 1 1---- rr--- 7T---- -T ---- r-r---F_1__TT--- 7-1---- r1---- TT-_F_1__ I-T---7-1----FF---TT--r_1---77----FF---TT---- 1--- T I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I 1 II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II II I I II II II 11 I I II II II II I I II II II II I LJ REAR ELEVATION SCALE: 3/16"=1'-O" TOP OF DOUBLE BOND BEAM WITH (2) BLOCK COURSES WITH #5 CONTINUOUS AND FILLED WITH 3.000 PSI CONIC. TOP OF DOUBLE BOND BEAM WITH (2) BLOCK COURSES WITH #5 CONTINUOUS AND FILLED WITH 3,000 PSI CONIC. 0 m 0 0 0 0 0 12 �4 ---Tr---T-7----rl---- rl----Tr--- 77----r1----T T- T- r--rl-1 II II II II II II II II II II II III II II II II II II II II II II II III II II II II II II II II II II II III II II II II II II II II II II II III II II II II II II II II II II II III tt----I-r----rr---tt-----r-r----rr---tt----t-t----rl----tt-----t-r---rl-I ---tr----�-r----rl-----t-r----�rt----r-I----Tr----�rt----rl----tr----rr---rrl ---T1----f7----1-1----T1-----IT----rl----T1-----7-1----n----Tr----1-I----rl-I II II II II II II II II II II II III II II II II II II II II II II I II II II II II II II II II II II I II II II II II II II II II II II I � ® II II II II II II II II II II II I II II II II II II II II II II II I II II II II II II II II II II II I II II II II II II II II II II II I II II II II II II II II II II II I � � II II II II II II II II II II II I II RIGHT ELEVATION SCALE: 3/16"=1'-0" 12 �4 -I 1---__17----7T----I,----1-1----77----1-1----T-7---77----17-- rT ---77----I III. II II II II II II II II II II II I III II II II II II II II II II II II I III II II II II II II II II II II II I I I I I I I I I I I I I I I I I I I I I I I I I F-1 III II II II II II II II II II II II I �L� II II II II II II II II II II II I rl��--I F---- tt----I-I----i r----Ft----I-I----t r--- tt----1 1----t-r----tt----I 1-1-1---'-irt-----1-1-----1-I----rr-----rtrt----1-1----1--1----rt-1-----1-7----1-t----7-r----y I-1-1---7 7----77----1-1----T-F----1-1----1-1----T1----77----17----rr- 77----1 III II II II II II II II II II II II I II I II II II II II II II II II II I II ®� I II II I I II II II I II II I II I II II II II II II II II II II I II I II II II II II II II II II II I II I II II II II II II II II II II I II I II II II II II II II II II II I II I II II II II II II II II II II I II I II II II II II II II II II II I II I II II II II II II II II II II I LEFT ELEVATION SCALE: 3/16"=1'-O" City of Port Saint Lucie Building Department Product Approval Submittal Affidavit Permit #: Building Address: Ft. Pierce, Florida Contractor: Jason Hsu FL # or Glass Attachment Method Type, Size, Spacing & Embedment Building Design Product Design Miami -Dade Product Model # Manufacturer Description NOTE: FILL ALL MANUFACTUERER'S PRE -DRILLED HOLES Pressure Pressure HEAD: 1/4" X 3-3/4" TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM FL21135.11 EXTERIOR SWING DOOR FIBER -CLASSIC THERMA-TRU MULLION. JAMBS: 1/4" X 3-3/4" TAPCONS SPACED 3" FROM CORNERS, 14" 27.6 PSF / -30.0 PSF +40.0 40.0 PSF SMOOTH STAR O.C. MAX. SILL: 1/4" DIA. X 2-1/4" TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM MULLION. FL12765.3 ROLLING SERIES 3100 JANUS «» STEEL GUIDE TO CONC.: 3/8" X 4" CONCRETE SCREW SPACED 12" O.C., 23.5 PSF / -25.8 PSF +27.5 / -31.6 PSF OVERHEAD DOOR INTERNATIONAL BARREL ASSEMBLY MOUNTING BRACKET TO CONC.: (3) 3/8" CONC. CORP. SCREWS W/ 1-1/2" MIN. EMBEDMENT MINIMUM 4" HEADLAP AND 6" ENDLAP MECHANICALLY FASTENED TO DECK WITH NOA 18-0409.06 ROOF GARDNER GARDNER «» APPROVED NAILS IN CAPS 6" O.C. MINIMUM AT ALL LAPS AND THREE UNDERLAYMENTS UNDERLAYMENTS ASPHALT CORP. STAGGERED ROWS FASTENED AT 12" O.C. MINIMUM IN THE FIELD OF THE ROLL. NAILS SHALL BE DRIVEN FLUSH AND 90 DEGREES TO THE ROOF DECK. DURATION, DURATION PREMIUM, TRU DEFINITION ROOFING NAILS SPACED 5-5/8" FROM BOTTOM EDGE OF SHINGLE, 1" FROM NOA 17-1211.02 ROOF SHINGLE PREMIUM, TRU DEFINITION OWENS CORNING ROOFING & «» EDGES AND 12" FROM EDGE NAIL, 6 FASTENERS MIN. PER SHINGLE PER ( PER TABLE R301.2 2 ( ) PREMIUM DESIGNER COLORS ASPHALT, LLC MANUFACTURERS RECOMMENDATIONS) COMPONENTS AND CLADDING WIND PRESSURES PER 2020 FLORIDA BUILDING CODE USING INTERIOR ZONE COEFFICIENTS AREA OF OPENINGS (SO. FT.) DESIGN PRESSURE 0 to 19"9 27.6 PSF / -30.0 PSF 20 TO 49.9 26.4 PSF / -28.7 PSF 50 TO 99.9 24.8 PSF / -27.1 PSF 100 TO 499.9 23.5 PSF / -25.8 PSF 500 AND ABOVE 20.6 PSF / -22.9 PSF USING END ZONE COEFFICIENTS AREA OF OPENINGS (SO. FT.) DESIGN PRESSURE 0 to 19.9 27.6 PSF / -37.0 PSF 20 TO 49.9 26.4 PSF / -34.5 PSF 50 TO 99.9 24.8 PSF / -31.2 PSF 100 TO 499.9 23.5 PSF / -28.7 PSF 500 AND ABOVE 20.6 PSF / -22.9 PSF DRAWING INDEX PROJECT & CODE DATA INDICATES TYPICAL VERTICAL I BLOCK CELL WITH CONTINUOUS #5 AND FILLED WITH 3,000 PSI CONC. INDICATES TYPICAL VERTICAL I BLOCK CELL WITH CONTINUOUS #5 AND FILLED WITH 3,000 PSI CONC. CVR INDEX / PRODUCT INFORMATION / ELEVATIONS *PLANS DESIGNED TO COMPLY WITH THE 2020 FLORIDA BUILDING CODE A-1.0 FOUNDATION PLAN / FLOOR PLAN TYPE OF CONSTRUCTION: CBS A-2.0 ELECTRICAL PLAN / ROOF PLAN BUILDING DESIGN: ENCLOSED A-3.0 WALL SECTIONS / DETAILS / NOTES WIND SPEED (3 SECOND GUST): 160 MPH NOMINAL DESIGN WIND SPEED: 124 MPH BUILDING CATEGORY: II EXPOSURE:B INTERNAL PRESSURE COEFFICIENT: +/- 0.18 IMPORTANCE FACTOR: 1 MEAN BUILDING HEIGHT: 157 OVERHANG: 1'-4" ROOF PITCH: 4 /12 RECEVED COMPONENTS AND CLADDING WIND PRESSURES: ; R 'All ROOF DEAD LOAD: (SHINGLE ROOF) 17 PSF dne Daaa"Iment t LU VR C010" SHUTTERS: YES NO X IMPACT RESISTANT ASSEMBLY: YES X NO DesP''vLLn G ro uLC 2194 HWY. A1A, SUITE 301, INDIAN HARBOUR BEACH, FLORIDA 32937PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F w W 0 W O h 0. V W q h A STORAGE UILDING FOR: JASON HSU PROJECT#, (FORT PIERCE, FL PAGE: Q F- Q �z O� f- - z UI-O � Q F � Q O O LLJ LL J z_ LLJ LLJ 0 ARCHITECT: STATE OF FLORIDA .sw�a p0,iei PRINT DATE: 3/2/21 SCALE: 3/16"= l'- 0" SHEET CVR A R C H IT E C T S LE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2• A I � 1 � ■ 0._0. I ■ OR FIBER ■ Iij IiI ■ MESH REFERENCE 8� BA HEIGHT AT SLAB CURB VARIA yR� $ e• r—o• j A DETAIL ■ I I ■ � I I I 6x6 — 10.10 WwF I I I I I I ■ I I ■ OR FIBER MESH I SLOPE I SLAB 1'-0• I I I I �/5 ■ I ■ BARS m 6- 3000 PSI CONC. SLAB W/ FIBERMESHON 6 r_p- BARRIEROVERTREATED A COMPACTED CLEAN FILL. q BL. POLY VAPOR DETAIL ER OVER ■ I � � I ■ 1 o I ■ I I I � ■ i I I i I I ■ I I ■ I I I I I I IINDICATES C.M.U. W/ CONCRETE ANDE((1 #5 VERT. REBAR CONT. FROM FOOTING ■ TO TIE BEAM (TYPICAL) I I I I I ■ i I I 3'-0' X 6'-O' 4' CONC. STOOP AT DOOR I I 4" C X 6'-O' --- - I - 4" CONC. STOOP AT DOOR I ■ I I ■ CURB CUT AT DOOR CURB CUT AT DOOR I B B B i ■ L---------------------- ---------- ------ -- ------------------------------- -----------� ■ JON N - 1 4' 0" 14'-0" 4" 0" 14, 0" 4' 0" 14• 0" 4' 0" 14' 0" 4 0" FOUNDATION PLAN SCALE: 3/16•=1'-O' on C�2 0 ■ cYa I ■ ■ 22"X54" ATTIC22•X54• ATTIC W/ %I ACCESS W/ ,/ a ■ STAIRS I \/ I STAIRS ■ _ �-y Frr---i W ■ ■ ■ r— ----- -- r — -- r -- ---- r------- — ----� ■ N -.. .. ■ ■ ■ ■ _ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ N 4,-0" 14 -0" 4'-0" 14'-0" 4'-0" 14•-0" 4'-0" 14'- D" 4'-0" FIRST FLOOR PLAN SCALE: 3/16"=1'-0" IAI IAI L L -N DOOR SCHEDULE O SIZE R.O. Q REMARKS 1 14'-O" X 14'-0" ROLL UP DOOR 4 EXT. DOOR 2 3068 SWING 39-1/2" X 83-1/2" M.O. 2 EXT. DOOR 2194 HWY. A1A, SUITE 301, INDIAN HARBOUR BEACH, FLORIDA 32937PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W W 0 U W 0 0. U W A ti A ti STORAGE 3UILDING FOR: JAsoN HSU PROJECT# FORT PIERCE, FL PAGE: ARCHITECT STATE OF FLORIDA ELC.A PRINT DATE: 3/2/21 SCALE: 3/16"=1'-0" SHEET A 1.0 A R C H I T E C T S 2194 HWY. A1A, SUITE 301, INDIAN HARBOUR BEACH, FLORIDA 32937PH: 321.802-3591 www.abdesigngroup.com AA #: 0003325 A F W W 0 W 0 F 0. r- W W A h Q h STORAGE 3UILDING FOR: JASON HSU PROJECT# FORT PIERCE, FL PAGE: z Q J z d Q J -J Qa 91, rK O F-- wry J w ARCHITECT: STATE OF FLORIDA nm PRINT DATE: 3/2/21 SCALE: 3/16" =1'-0" SHEET A 20 A R C H I T E C T S 12 ASPHALT SHINGLE ROOFING OVER R 15# FELT ON 5/8" CDX PLYWOOD SHEATHING PER AND PRE-ENGINEERED WOOD ROOF TRUSSES AT 24" O.C. (SEE ROOF NAILING PATTERN DETAIL) HURR. STRAP ® EACH TRUSS STRUCTURAL NOTES: WATERPROOFING NOTES: REFER TO CONNECTOR 'SCHED.- 1. WIND LOAD REQUIREMENTS AT 160 MPH PEAK WIND GUST FOR 1. PRIOR TO BUCK INSTALLATION, TREAT THE MASONRY OPENING WITH A P.T. 2X4 BLOCK W/ CASE 3 SEC. BURST PER ASCE 7-10 / 2017 FBC. CMU WATER RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE CMU WATER RESISTANT HARDENED NAILS AT 24" O.C. 2. WINDOWS, DOORS, AND GARAGE DOORS SHALL BE DESIGNED TO COATING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S THE 2017 FLORIDA BUILDING CODE RESIDENTIAL 6TH EDITION. RECOMMENDATIONS. THE APPLICATION OF THE CMU WATER RESISTANT TOP OF BLOCK 3. ALL FLOOR SLABS TO BE OF 3000 PSI CONCRETE PLANT MIX COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE OPENING 8" 4" THICK WITH FIBER MESH AND/OR 6 X 6-10//10 W.W.M. W/ MIN. MINIMUM EACH DIRECTION. ALL CMU WATER RESISTANT COATINGS SHALL REFER TO EXT. ELEV. 1" COVER ON 6 MIL POLY VAPOR BARRIER OVER BE INSTALLED PRIOR TO BUCK INSTALLATIONS. • 1X6 HARDITRIM FASCIA COMPACTED CLEAN FILL. AND DRIP EDGE OVER 4. FIBER MESH REINFORCEMENT: FIBERS SHALL BE 1/2" TO 3/4" 2. INSTALL BUCKS SO THERE ARE NO EDGE GAPS EXCEEDING 1/8" 8"x8" U-BLOCK TIE -BM. FILLED 2X4 SUBFASCIA COLLATED POLYPROPYLENE FIBERS. REQUIRED DOSAGE RATE BETWEEN BUCK AND MASONRY. W/ CONIC. & (1) #5 REBAR CONT. SHALL BE AS SPECIFIED BY THE MANUFACTURER. FIBERS SHALL BE USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD PRE-ENG'RED PRECAST LINTEL CEMENTITIOUS RECOMMENDATIONS AND WITHIN TIME AS SPECIFIED IN "ASTM C94". OF SEALANT BETWEEN THE BUCK AND THE MASONRY TO PREVENT THE SEE SHEET A 4.0 FOR DETAILS COATING ON HIGH RIB THE FIBERS SHALL COMPLY WITH ASTM DESIGNATION C1116 PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END METAL LATH SOFFIT TYPE 111 4.1.3 AND WITH APPLICABLE BUILDING CODES. OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASAGE OF LIQUID 1'-4" WITH CERTIFICATION OF COMPLIANCE SHALL BE MADE AVAILABLE THROUGH THE CUT ENDS, AND THE ENTIRE EXTERIOR FACE AND RETURN NEON REQUEST. STANDARD ACI 302 PROCEDURES FOR PLACING, SURFACE OF THE BUCK SHALL BE COATED WITH A LIQUID APPLIED WATER SCREENED D V VENTS FINISHING, AND CURING SHALL BE FOLLOWED WHEN USING RESISTIVE COATING SEALANT. - �D-OOR HDR. HT. SPACED 48" O.C. FIBER MESH CONCRETE. / PER PLANS 5. CONCRETE MASONRY UNITS SHALL MEET ASTM C90. 4. PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON WINDOW / DOOR FRAMES AT ALL PERIMETER ON FRONT AND BACK SURFACE PRIOR TO 6. MORTAR TO BE TYPE 'M' OR 'S': GROUT TO BE 3000 PSI WINDOW / DOOR INSTALLATION. AT 28 DAYS. FOLLOW GROUT CONFINEMENT PROCEDURES AS DEFINED IN ACI 53-99. f'm = 1500 psi 5. AFTER WINDOW / DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THE BUCK (OR PRECAST SILL) AND THE WINDOW / DOOR TO 8. REBAR TO BE SIZE #5 GRADE 40, CONT." ENSURE A WATER RESISTANT INTERIOR AIR SEAL AROUND THE ENTIRE TOP OF FILL CELLS AND PERIMETER. CHANGES OF DIRECTION WITH MINIMUM LAP OF 30 9. OMIT 10. UPLIFT CONNECTORS TO PROVIDE CONTINUITY FROM ROOF TRUSSES THRU PLATES TO SLAB AND FOUNDATION PER ENCLOSED DETAILS. 11. EPDXY ANCHOR ALTERNATE: THREADED ANCHOR ROD MAY BE USED IN LIEU OF ANCHOR BOLTS -FOR USE AS PLATE ANCHORS OR HURRICANE ANCHORS. THE FOLLOWING CRITERIA MUST BE MET: ANCHOR 2SIZE CONC. HOLE SIZE MIN. HOLE DEPTH 5/8 7/8.. 7" 3/4,. 1 8 7/8" 1 1/8" DOUBLE KNOCK OUT BLOCK BOND BEAM AFTER HOLE IS DRILLED ALL CONCRETE DUST MUST BE R&OVED WITH #5 CONTINUOUS AND FILLED BOND BEAM HT. PRIOR TO EPDXY INSTALLATION. THREADED ROD (MIN. A36 WITH 3,000 PSI CONC. PER PLANS STEEL) AND REBAR TO BE FREE OF DIRT OR GREASE. LOAD ON ROD OR REBAR CANNOT OR BE APPLIED UNTIL 12 HOURS AFTER APPLICATION. TWO COMPONENT EPDXY RESIN MATERIAL TO BE MIXED PER MFG. DIRECTIONS. 12. MISSING DOWEL PLACEMENT NEW HOLE SHALL BE DRILLED 7/8" TO 1" WIDE AND 10" DEEP. AFTER HOLE IS DRILLED ALL CONCRETE DUST MUST BE REMOVED PRIOR TO EPDXY INSTALLATION. THREADED ROD (MIN.. A36 STEEL) AND REBAR TO BE FREE OF DIRT OR GREASE. LOAD ON ROD OR REBAR CANNOT OR BE APPLIED UNTIL 12 HOURS AFTER APPLICATION. TWO COMPONENT EPDXY RESIN MATERIAL TO BE MIXED PER MFG. DIRECTIONS. WOOD STRUCTURAL NOTES: 1. ALL WOOD TO BE SPECIES, GROUP, AND GRADE AS SHOWN ON DETAILS. DAMAGED WOOD NOT TO BE USED. 2. GROUP 1I WOOD IS SOUTHERN YELLOW PINE #2. Fb=1200 PSI, E=1,600,000 PSI, M.C.=19% MAX.,TYP, PINE GROUP III WOOD IS DOUGLAS FIR -LARCH, SOUTHERN YELLOW PINE, HEM -FIR, OR SPRUCE -PINE -FIR. 3. ROOF TRUSSES TO BE SET WITHIN 5" OF STUD LOCATED BELOW. CEMENTITIOUS COATING OVER 4. END JOINTS IN STRUCTURAL DOUBLE TOP PLATE SHALL BE OFFSET AT LEAST 4'. STRUCTURAL DOUBLE PLATES TO BE 8x8x16 CONC. BLOCK NAILED AT 6 O.C. MAX. 5. EXT. SHEATHING ON WALLS TO BE MIN. 15/32" COX PLYWOOD. WALL NAIL PATTERN TO BE 6" O.C. W/ 10d NAILS UNLESS OTHERWISE NOTED, 6. ALL STRUCTURAL LUMBER (EXCLUDING PREENG. WD. TRUSSES) 1-#5 VERT. BAR TIED INTO TO BE #2 OR BETTER GROUP 11, UNLESS OTHERWISE NOTED. #5 BAR DOWEL W/ STD HOOK "7. STRUCTURAL HEADER SIZES SHOWN ON ROOF FRAMIN PLAN AND RUNNING INTO LINTEL ARE TO BE #2 OR BETTER, SPECIES GROUP II. HEADER SHALL (LOCATIONS PER FDTN. PLAN) HAVE A MIN. 1/2 COX PLYWOOD SPACER. B. MAX. 1" HOLE DRILLED INTO EXTERIOR STRUCTURAL STUDS. 9. STUDS TO BE DOUBLED AT EACH END OF SHEARWALL AS PER DRAWINGS. 10. WHEN ANCHORING (2) WOOD ITEMS TOGETHER, THE LENGTH OF HURRICANE STRAP MUST BE EQUALLY HALF ON EA. ITEM. I 11. NAIL PATTERNS: -DOUBLE PLATE AT 12" O.C. OUTSIDE THE SPLICE ZONE (SEE NOTE #4). -DOUBLE STUD NAIL PATTERN AT 12 O.C. I -DOUBLE HEADER NAIL PATTERN AT 6" O.C. AT EA, EDGE, 12" O.C. INTERNALLY. -HEADER TO STUD- 4" O.C. EA. HEADER MEMBER 5' -STUD TO TOP OR BOTTOM PLATE (2)16d END NAILED OR (2)16d TOE NAILED EA. SIDE -ALL INTERIOR HEADERS TO BE (2) 2x O ROOF EDGEif O r WITH 1/2" FLITCH GLUED AND NAILED WITH 16d AT 8" O.C. STAGGERED. - - - - - - - - - 12. ROOF SHEATHING TO BE MIN. 15/32" COX ( y�A O (j I �3 ROOF 6 MIN. CONC. SLAB PLWOOD NAILED PER ROOF NAILING PATTERN EDGE DIAGRAM. - - - - - - OVER PSI) W/ FIBER MESH 13. ALL NAILING SPECIFIED TO BE APPLIED BY NAIL GUN O OVER VAPOR BARRIER I 4' OVER CLEAN COMPACTED AND/OR MANUALY. O I O I� _ RIDGE TERMITE TREATED FILL --�0--0" 14. TRUSS BRACING PER TRUSS MFG. DRAWINGS. Y OP OF SLAB 15. AT ALL INTERIOR WALLS THAT ARE NOT LOAD BEARING, I 2 2 O � METAL STUDS MAY BE SUBSTITUTED FOR WOOD STUDS. - - - - I FINAL GRADE 16. ANCHOR „ I �1 1 LCC 1 1 I g 0 BOLTS 8" LONG x 1/2 DIA. WITH A 2" F O O O STUCCO STOP AS REQ'D. SQUARE X 1/8" THICK HURRICANE WASHER EMBEDDED 5" PER LOCAL BLDG. DEPT. UNLESS 17.ALL EXTERIOR CEILING TO BE STUCCO FINISH ON HIGH RIB O aPy O O O it • CONC. FTG. PER METAL LATH. FOUNDATION PLAN ZONE 1-USE 8d RING SHANK NAILS ® 6" O.C. ZONE 2-USE 8d RING SHANK NAILS ZONE 3-USE 8d RING SHANK NAILS TYP EXT. BLOCK WALL O ® 6" D.C. 0 ® 4" D.C. NAILING PATTERN FO R ROOF ROOF SHAPE REPRESENTS TYPICAL ZONES ONLY. 2194 HWVY, AIA, SUITE 301, INDIANI HARBOUR BEACH, FLORIDA 32937PH: 321-.802-3591 www.abdiesigngroup.com AA #: 0003325 F W W v W 0 h a U W A h A 2 ti STORAGE UILDING FOR: JASON HSU PROJECT.# 200 000 2021- FORT PIERCE, FL PAGE: I- (n U __I (W Q _J W J W >Q ARCHITECT STATE OF FLORIDA d1 AICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 3 2 21 SCALE: 3/16"=1'- O" SHEET A 3.0