Loading...
HomeMy WebLinkAboutConstruction PlansCONTRACTOR: TRI-COUNTY ALUMINUM, INC. PES'1'GN CRITERIA: ,Applicable Codes, Regulations, and Standards 1. The 7th Edition (2020) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADM1 Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-16. Loading Criteria 1. Live Load: 10 PSF per 7th Edition (2020) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 1 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Ultimate Design Wind Speed: Vua =150 Nominal Design Wind Speed: VAsn =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure B 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1 - Patio Cover / Screen Room: Non -Habitable, Unconditioned Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 12" x 0.019" Four Seasons Building Products Steel Rhino Panel. Florida Product Approval Number FL 18464-R2. Foundation Design Existing concrete slab. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if tine existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, snalling. or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 7th Edition (2020) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Florida Aluminum Engineering, Inc. 3. Screen material shall be 18/14 screen unless approved by Florida Aluminum Engineering, Inc. 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 5. Approved concrete screw anchors to be Simpson Titen-HD or equivalent. 6. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or 412 screws 6" from ends and 12" center to center. 7. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type I,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1%- ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: L Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 8. All flashing and weatherproofing shall be provided by the contractor. 9. Door location shall be determined by contractor in the field. 10. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND EXPOSURE HAVE BEEN DETERMINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. RECEIVED FEB ® 9 2020 ST. Lucie County, Permitting 10'-0" o 3X3XO.090 POST 1X3 (TYP) 2X3GIRT `TM 3X3XO.090 a POST I 0 3X3XO.090 POST - 2XDJ :t X 10 N I 2XDJ 3X3XO.090 POST / S-2 \ / S-3 1 A-3 A-3 1'-0" 10'-0" 7'-4" 7'-4" 7'-4" 2X5SMB 2X5SMB Z 4TH WALL 4TH WALL c 2X3XO.045 3"X12"X0.019° END BEAM RHINO PAN 2X3X0.045 END BEAM 2X3XO.045 END BEAM O U Co c� 2X3XO.045 2X5SMB S-4 BEAM EDGEA-3 A-3 BEAM A-3 I I 20'-0" 22'-0" 42'-0" I Co %-- 1'-O' 6'-B" 6'-8" 6'-B" 7'-4" �I 7'-4" 7'-4" 20'-0" II 22'-0" �� •.• s °' i v UJ Q r' .Lo %�o ••• •.. '4� 10'-0" 3X3XO.090 POST o m o I I I p� O A-4 3X3XO.090 POST 8'-6" I� I V-0• ZIUZ-O22I REVIEWED FOR CODE COMPLIANCE STa LUCIE COUNTY socc 2(Zzr2� W L1J W p: Z Z w J X Z Q Z LLJ V) N t� to Q W LU LL O O tY = t1 ~ 2 C - i; Z m •�Of4, z 5 Z H'43 Q W ui WI ZESS z 0 Z gam52 R o N C OZ� ,n o J W LL U- r%' 0- N &- CCO � C7 < Q J "r III W(Au 0 Z0F,rn Z(DtYCY) d N ° -Ji DRAWN BY TP 01 /12/21 SHEET NO: A-1 ALUMMM MEMBERS DEMIENSIONS ��II►II/// `,`ttttttt %, � HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.046" � ,`'C •' • • • y ��' •' . . • 2x3: 2"x3"x0.050" •'. 2 x 4: 2" x 4" x 0.050" w !(� LL 6• 2x5: 2"x5"x0.050" = Q 2 o O OPEN BACK SECTIONS a V 1 * FW- O • Z 1x2: 1"x2"x0.040" • ; i N O Q 0� 1x3: 1"x3"x0.045" l�vt SNAP SECTIONS i� •• Z • •••• 110 2 x 2 Snap: 2" x 2" x 0.045" I , /Y I • • • • p�� ; 2x3Snap: 2"x3"x0.050" 2 x 4 Snap: 2" x 4" x 0.045" I I 3" x 3" x 0.090" I I POST x 0.090" POST I SELF MATING (SMB) (2) 3/8" DIA CONCRETE I -Al 2 x 4 SMB: 2" x 4" x 0.044"x 0.100" SCREW ANCHORS 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" (3" CONC. EMBED) I I I LuW Lu 2 x 6 SMB: 2" x 6" x 0.050"x 0.120" I I (2) 3/8" DIA. CONCRETE SCREW ANCHORS a Z 2 x 7 SMB: 2" x 7" x 0.057"x 0.120" I I (3" CONC. EMBED) INTERNAL/EXTERNAL . m 2 x 8 SMB: 2" x 8" x 0.072"x 0.124" 1" x 3" OB W/ 1/4" CONCRETE INTERNAL/EXTERNAL I I 3" x 3" x 1/8" EXTRUDED W Z l0 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" SCREW ANCHOR 6" I 3" x 3" x 1/8" EXTRUDED I POST BASE W/ (2) 3/8" I Lu Z 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" FROM UPRIGH4D@) I POST BASE W/ (2) 3/8" DIA. THRU BOLTS J 24" O.C. (MIN. 3" EMDIA. THRU BOLTS Q Q O MINIMUM FASTENER EDGE DISTANCE:1/2" - -" — i z Z 0 v)Q MINIMUM FASTENER SPACING: 3/4" WCONCRETE SCREW ANCHOR: aSIMPSON TITEN HD OR EQUIVALENT 0 SHEET METAL SCREWS (SMS):ITW / BUILDEX OR EQUIVALENT °d" ' ' • ° ° d ' : , e F- . ° r V ^ B' = Z „ B T x 3 POST TO CONCRETE CONNECTION DETAIL 3" x 3" POST TO CONCRETE CONNECTION DETAIL Z— /� n A-2 SCALE: NTS A_2 SCALE: NTS . ^� � O Vr N m � -, u z tmn^ - J , �; S Qu.j z Lu zSawaro v -- F W- 3 :aLL 1/8" x 2" x 2" EXTRUDED o z$ ' ANGLE 5052 H-32 ALLOY J LLJ LL W/ (4) #14 x 3/4" SMS o o L L INTO DJ o w REVIEWED FOR ®MPLIAMCE SLAB FOOTING Y1 ' e° 2 114- MIN CONC ANCHOREMBEDMEM ' C LIE COUNTY � SEE PLAN ': a • °. ° ° •e ' e' e• •'° \d �o I I B®C6A d 4 A' CHAIR RAIL MEMBER I I D L; o SIDE VIEW >- w (1) 3/8 DIA. CONCRETE j/j 1"x 1" x 1/8" ANGLE W/ I I J m SCREW ANCHORS UPRIGHT 0 F- (V (2) #14 x 5/8' EACH FLANGE I I uj Z 0_ rn (21/4" CONC. EMBED) i j PRE -HUNG OORJAM DOOR JAMB EACH SIDE OF UPRIGHT O I �' � I I ( 3" x 3" x 0.090" POST . c� � }Sz LL C. yNa-LL - ` I DRAWN BY °4 4• TP V x 3" BASE PLATE " '' . ° "• DATE DRAWN ANCHORED TO CONC W/ 1/4" d ;° a ; ' 01 /12/21 CONCRETE SCREW ANCHOR ° 4 '. (MIN. 1 1/4" EMBED) ° •'a °a REVISION 6" MAX EACH SIDE OF POST e 1 AND 24" O.C. MAX ° C CHAIR RAIL TO POST CONNECTION DETAIL 2 _ FRONT VIEW A-2 SCALE: NTS - DJ-1 UPRIGHT TO CONCRETE PRE -HUNG 4 SHE A_2 DOOR LOCATION DETAIL SCALE: NTS A-2 ^J 3" x 12" RHINO - ,,��`I{III ' #14 x 3/4" SMSW/ PAN PANEL ```�\ NEOPRENE FACED #14SMSx3/4"W! � WASHER @ 4" O.C. •••.•• WASHER @ 12'CO.C. ALONG ���` • � LENGTH o � � � OF ALL END BEAMS � Q =a :w � FLASHING SHING � :•� Z Y � �/// •••.••••• 2"x3"TOP RAIL - NO ANGLE REQUIRED UNLESS � I J I RISER #14x314"SMSW( OTHERS O // SPLICED OR CORNER - � Q 2�� x 3� PANEL NEOPRENE FACED 3" x 12' RHINO / ATTACH W/ (4) #10 x 4" LG END BEAM WASHER @ 4" O.C. PAN PANEL Z i i � 3" 1 `ryry IIIIUt/I/ //i O / I • •. • '•��c�2 LL •••� AA� 1` - w — a H v• O ` ' • • Q�Oj ,``�� 1111111���� x E a W W a W �C'. Z ` Cn z zL W z Lp J C_' a z LL z O N vu'i z N a W i W CC Ll C z O = d a c c LA C C IL �j g o C z Z N m C t= m m p J z G V N N N fJ LL Z.mn a .� 22 �,-m g a <mm W w a m m a W K� w Q _Z �IQ-F Q LL O IZ $ C LL 3 a a z_ C C LL x 3 z c L N D' CL C W O LL a Q z 2 ZjW C Q� j z UJI Z 0 O rn ySZyU0� C. SN(LLLLL DRAWN BY TP DATE DRAWN 01 /12/21 REVISION 4 SHEET NO: A-3- x! Ll J V 101, u- Owl o CD ,:_ w =a :� �c w is o 0 co • �?3 •, Z . .• ��II/I / 111111 / 1111f�� x ul w W W f0_ c Z �c Z W Lo W Z w z Z J Q Z LLL z O °' V) L z C Ln Q W W V - u_ O G. a a - _ c a ��{ ®® ��Q3I FOR O ZEWED Zmm� LL C CODE COMPLIANCE z z x g a p.� S GIwpm o LUCIE CO UN� COUNTY D J � soccJ W wag W O~o Z Q W zavv u � g~ALL a s 1D o O Zin ~ LJI . W 3" RHINO PAN ROOF PANEL 2" x SMB EDGE BEAM a a o #14 x 3/4" SMS W/ NEOPRENE FACED WASHER @ 12" O.C. #14 x 3/4" SMS W/ ALONG LENGTH OF ALL NEOPRENE FACED END/CROSSBEAMS WASHER @ 4" O.C. 2" x 3" x 0.045" END BEAM 2" x 3" x 0.045"_ KNEE BRACE 1 1/2" x 21/8" x 1 1/2" x 0.062" x 3" LONG ALUM RECEIVING CHANNEL W/(3) #12 x 3/4" SMS EA. FACE & (3) #12 x 3/4" INTO POST —"V-- \_3" x 3" x 0.090" POST S-7 KNEE BRACE CONNECTION DETAIL A-4 SCALE: NTS a a a 2" x 3" x 0.045" KNEE BRACE 3" RHINO PAN ROOF PANEL 1 112" x 21 /8" x 1 1/2" x 0.062" x 3" LONG ALUM RECEIVING CHANNEL W/ (3) #12 x 314" SMS EA. FACE & (3) #12 x 3/4" INTO POST #14 x 3/4" SMS W/ NEOPRENE FACED WASHER @ 4" O.C. 12" MAX OVERHANG S-H KNEE BRACE CONNECTION DETAIL A -A SCALE: NTS x 3" x 0.090" V) D_ W 0 � U (D 0 Q W W W � (1)Lo m zp�o) zC�O_M d N 0_ LL DRAWN BY TP DATE DRAWN 01 /12/21 REVISION 1 _ A a _ SHEET NO: A -4