Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business 'and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE WIN SOR IMPACT BuilderName: WYNNE DEVELOPMENT Street: `g�qy� Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner: Jurisdiction: DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. Newconstructionorexisting New (From Plans) 9. Wall.Types.(1432.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 3. Number of units; if multiple family 1 b: Frame - Wood, Adjacent c. N/A R=11.0 208,00 ft2 R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1783.0 sqft.) Insulation ' Area a. UnderAttic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floorareabelowgrade(ft2) 0 c. N/A R= ft2 11.. Ducts R ft2 7. Windows(151.4 sgft.) Description iArea a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0:29 b. U=Factor: Sgl, U=1.11 ' 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC' SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heatingsystems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: = 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sgft.) Insulation, Area a. Electric Cap: 50 gallonsEF:0.970 a. Slab -On -Grade Edge Insulation R=0.0 175300ft2 b. Conservation features b. N/A R= ft2 None c: N/A R= ft2 i 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.17 PASS Total Baseline Loads: 53.92 hereby certify'that the plans and specifications, covered by' Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance - with the Florida Energy Code. PREPARED' $ - - - Before construction is completed' �- DATE: 4-21-2020 this building will be inspected for compliance with Section 553.908 ' I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code.' OWNE A NT• BUILDING OFFICIAL: DATE DATE: i - Compliance requires certificationby the air'handler unit manufacturer that the air handler enclosure qualifies as certified factory�sealed in accordance with 11403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with. R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 4/21 /202010:04 AM EnergyGauge® USA 6:0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1. of 6 FORM R405-2017 INPUT•SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms:. 3 Address Type: Street Address BdildingType: User ConditionedArea: 1753 Lot# OwnerName: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst.Case: Yes PlatBook: BuilderName: WYNNE DEVELOPMENT RotateAngle: 0 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family. FL, New/Existing: New (From Plans) Comment: i CLIMATE / i Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMYSitei 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area j Volume 1 EntireHouse 1753 14024 SPACES Number Name Area I Volume; Kitchen Occupants Bedrooms InfilID. Finished Cooled 'Heated 1 MASTER BEDROO 224 i 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0" 1 1 Yes Yes ' Yes 7 DINING/GREAT.RO 588, 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1' Yes. .Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER. 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 37ft 0 224 ft2 ---- 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 I 63ft2 ---- 0 1 0 3Slab-On-Grade Edge Insulation MASTiERBATH 8ft 0 56ft2 ---- 0 1 0 4Siab=On-Grade Edge lnsulation M.'BATH 7ft 0 i 61ft2 ---- 0 1 0 5Slab-On-Grade Edge Insulation LAUDRY 1 ft 0 36ft2 ---- 0 1 0 4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulation BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 7 Slab -On -Grade Edgeinsulation DINING/GREAT 50ft 0 588ft2 ____ 0 1 0 8Slab-On-Grade Edge Insulation KITCHEN 11 ft 0 209f12 ____ 0 1 0 9Slab-On-Grade Edge Insulation BATH 5 ft 0 I 50 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulation HALL 1 ft 0 25ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulation FOYER .9ft 0 92ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulation BEDROOM 3 14 ft 0 169 ft2 _ ____ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt . Emitt. Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.4 No 0.9 No 0 18.4 ATTIC. V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 .1753 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type . 1 UnderAttic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63ft2 0.1 Wood 3 UnderAttic(Vented) MASTER BATH 30 Blown 56ft2 0.1 Wood 4 UnderAttic. (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 UnderAttic(Vented) LAUDRY 30 Blown 36ft2 0.1 Wood 6 UnderAttic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 UnderAttic (Vented) DINING/GREAT 30 Blown 588ft2 0.1 Wood 8 UnderAttic(Vented) KITCHEN 30 Blown 209ft2 0.1. Wood 9 UnderAttic(Vented) BATH 30 Blown 50ft2 0.1 Wood 10 UnderAttic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 UnderAttic (Vented) ' FOYER 30 Blown 92 ft2 0.1 Wood 12 UnderAttic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Omt To Wall T�fpp Cavity Width Space Ft In Height Et In Area Sheathing Framing Solar R-Vahle Eraction Ahqnr Below o 1 E Exterior Concrete Block- Int InsuMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 2 W Exterior • Concrete Block- Int InsuMASTER BE 4.1 7 d 0 8 0 56.0 ft2 0 0 0.3 0 _ 3 . S Exterior Concrete Block- Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 . 0.3 0 4/21 /2020 10:04 AM i EnergyGauge® USA 6i 0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT St1MMARV rNFrKi 'icT RRanDT WALLS Adjacent Cavity Space .Width _ Height Sheathing Framing Solar Below 0 4 E Exterior Concrete Block - Int InsuMASTER BA 4.1 • 8 0 8 0 64.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int Insul M. BATH 4.1 7. 0 8 0 56.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 _ 7 S Exterior Concrete Block- Int InsuDINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 8 W Exterior Concrete Block- Int InsuDINING/GRE _ 4.1 20 i 0 8 0 160.0 ft2 0 0 0.3 0 9 W Exterior Concrete Block- Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 E Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 11 N Exterior Concrete Block- Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 N Exterior Concrete Block- Intinsul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _ 13 W Exterior Concrete Block- Int InsuBEDROOM 3 .4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block - Int Ins uBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _ 15 N Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 'S 3 Metal Low-ESingle Yes 1.04 '0.29 N 32.4 ft2 1 ft 0 in 1 ft5 in Drapes/blinds Exterior5 2 E 5 Metal Low-ESingle Yes 1.04 0.29 N 6.9 ft2 1 ft 0 in 1 ft 5 in None None 3 E 6 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in None None 4 S 7 Metal Low-ESingle Yes 1.04 0.29 N 39.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W 8 Metal Low-ESingle Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in None None 6 W 13 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft5 in Drapes/blinds Exterior5 GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft? .26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000.254 1168.7 64.16 120.66 .0881 5 4/21 /202010:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition•(2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency , Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15 34.8 kBtu/hr cfm u6 1 sys#1 I HOT WATER SYSTEM # . System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg . None SOLAR HOT. WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS / — Supply--- -- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area LeakageType Handier TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 1 Attic 55 ft2 DefaultLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Cooling Jan Feb Heating Jan Feb Mar Mar •A r f 'Apr f Ma Jun Jul MaY Jun Jul Auge [ Aug Sep Oct H:Nov f Oct Nov Dec HDec Venting Jan Feb Mar [X] Apr [ May Jun Jul [ ] Au Se [X] Oct Nov Dec.` ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 r 78 78 78 78- 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 -66 68 68 68 68 68 68 68 PM 68. 68 68 68 68 . 68 68 68 68 68 .66 .66 MASS Mass Type Area Thickness Furniture Fraction , Space Default(81bs/sq.4. 0 ft? 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(81bs/sq.ft. ft2 ft 0.3 LAUDRY Default(81bs/sq-ft. ft2 ft 0.3 BEDROOM 2 ' Defaul48lbs/sq.ft. ft2 ft 0.3 DINING/GREAT RO Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN 4/21 /202010'04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS . Mass Type Area Thickness Furniture Fraction Space. Default(8lbs/sq.ft. ftz ft 0.3 BATH Default(8lbs/sq.ft. ftz ft 0.3 HALL Default(8lbs/sq.ft. ftz ft .. 0.3 FOYER Default albs/s .ft. ftz ft 0.3 BEDROOM.3 4/21/202010:04 AM EnergyGauge® USA6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 , ' , 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND' INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT.. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A. continuous air barrier shall be installed in the building:envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in'the air barrier shall be sealed. not be used as a sealingmaterial. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps.in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic space's shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the -cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. . Exterior thermal envelope insulation for framed walls.shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim .joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including. insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be incontact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvente'd crawl spaces'shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace Shafts, penetrations Duct shafts, utility penetrations; and flue shafts opening to exterior or unconditioned s ace shall be sealed. - Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the: available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on. exterior wall tubs shall separate them;from the showers,and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls tioxes.or air -sealed boxes shall be installed. HVAC register boots HVAC register boots -that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed flee sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordancawith the provisions of ]CC-400: 4/21/202010:05 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant. Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy. Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2: Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity . 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab-on=grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 1 OA1. e) Dedicated heat pump with tank EF 2, Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. . 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type. and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier. installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required :by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I'certify that this home has complied with, the Florida Building Code, Energy .Conservation, through the above energy saving features which will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address:of New Home:y C y \i City/FL Zip: FT. PIERCE. FL 4/21/202010:05:25 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1