HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business 'and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE WIN SOR IMPACT
BuilderName: WYNNE DEVELOPMENT
Street: `g�qy�
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner:
Jurisdiction:
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. Newconstructionorexisting
New (From Plans)
9. Wall.Types.(1432.0 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
3. Number of units; if multiple family
1
b: Frame - Wood, Adjacent
c. N/A
R=11.0 208,00 ft2
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is this a worst case?
Yes
10. Ceiling Types (1783.0 sqft.)
Insulation ' Area
a. UnderAttic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2)
1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floorareabelowgrade(ft2)
0
c. N/A
R= ft2
11.. Ducts
R ft2
7. Windows(151.4 sgft.) Description
iArea
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04
111.36 ft2
SHGC: SHGC=0:29
b. U=Factor: Sgl, U=1.11
' 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC' SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A
ft2
SHGC:
13.Heatingsystems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth:
= 2.850 ft.
Area Weighted Average SHGC:
0.285
14. Hot water systems
8. Floor Types (1753.0 sgft.)
Insulation, Area
a. Electric
Cap: 50 gallonsEF:0.970
a. Slab -On -Grade Edge Insulation
R=0.0 175300ft2
b. Conservation features
b. N/A
R= ft2
None
c: N/A
R= ft2
i
15. Credits
Pstat
Glass/Floor Area: 0.086
Total Proposed Modified Loads: 52.17
PASS
Total Baseline Loads: 53.92
hereby certify'that the plans and specifications, covered by'
Review of the plans and
this calculation are in compliance with
the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
-
with the Florida Energy Code.
PREPARED' $ - -
-
Before construction is completed'
�-
DATE: 4-21-2020
this building will be inspected for
compliance with Section 553.908
'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.'
OWNE A NT•
BUILDING OFFICIAL:
DATE
DATE:
i
- Compliance requires certificationby the air'handler unit manufacturer that the air handler enclosure qualifies as
certified factory�sealed in accordance with 11403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with. R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
4/21 /202010:04 AM EnergyGauge® USA 6:0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1. of 6
FORM R405-2017 INPUT•SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms:. 3
Address Type:
Street Address
BdildingType: User
ConditionedArea: 1753
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst.Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 0
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family.
FL,
New/Existing: New (From Plans)
Comment:
i
CLIMATE
/
i Design Temp
Int Design Temp
Heating
Design
DailyTemp
V Design Location
TMYSitei 97.5 % 2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area j Volume
1 EntireHouse
1753 14024
SPACES
Number Name
Area I Volume; Kitchen Occupants
Bedrooms
InfilID.
Finished Cooled
'Heated
1 MASTER BEDROO
224 i 1792 No 0
1
1
Yes
Yes
Yes
2 WIC
63 504 No 0
1
No
Yes
Yes
3 MASTER BATH
56 448 No 0
1
Yes
Yes
Yes
4 M. BATH
61 488 No 0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No 0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No 0"
1
1
Yes
Yes '
Yes
7 DINING/GREAT.RO
588, 4704 No 2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes 0
1
Yes
Yes
Yes
9 BATH
50 400 No 0
1'
Yes.
.Yes
Yes
10 HALL
25 200 No 0
1
No
Yes
Yes
11 FOYER.
92 736 No 0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No 0
1
1
Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO 37ft 0
224 ft2
----
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
I
63ft2
----
0 1
0
3Slab-On-Grade Edge Insulation
MASTiERBATH 8ft 0
56ft2
----
0 1
0
4Siab=On-Grade Edge lnsulation
M.'BATH 7ft 0
i
61ft2
----
0 1
0
5Slab-On-Grade Edge Insulation
LAUDRY 1 ft 0
36ft2
----
0 1
0
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value Area
JoistR-Value
Tile Wood
Carpet
6 Slab -On -Grade Edge Insulation
BEDROOM 2 12 ft 0
180 ft2
____
0 1
0
7 Slab -On -Grade Edgeinsulation
DINING/GREAT 50ft 0
588ft2
____
0 1
0
8Slab-On-Grade Edge Insulation
KITCHEN 11 ft 0
209f12
____
0 1
0
9Slab-On-Grade Edge Insulation
BATH 5 ft 0
I
50 ft2
____
0 1
0
10SIab-On-Grade Edge Insulation
HALL 1 ft 0
25ft2
____
0 1
0
11SIab-On-Grade Edge Insulation
FOYER .9ft 0
92ft2
____
0 1
0
12SIab-On-Grade Edge Insulation
BEDROOM 3 14 ft 0
169 ft2
_
____
0 1
0
ROOF
/
Roof Gable
Roof Rad
Solar
SA Emitt
. Emitt. Deck Pitch
V
# Type Materials Area Area
Color Barr
Absor.
Tested
Tested Insul. (deg)
1 Hip Metal 1847 ft2 0 ft2
Light N
0.4
No 0.9
No 0
18.4
ATTIC.
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented 150
.1753 ft2
N
N
CEILING
# CeilingType
Space R-Value
Ins Type
Area
Framing Frac
Truss Type
.
1 UnderAttic (Vented)
MASTER BEDRO 30
Blown
224 ft2
0.1
Wood
2 UnderAttic(Vented)
WIC 30
Blown
63ft2
0.1
Wood
3 UnderAttic(Vented)
MASTER BATH 30
Blown
56ft2
0.1
Wood
4 UnderAttic. (Vented)
M. BATH 30
Blown
61 ft2
0.1
Wood
5 UnderAttic(Vented)
LAUDRY 30
Blown
36ft2
0.1
Wood
6 UnderAttic(Vented)
BEDROOM 2 30
Blown
180 ft2
0.1
Wood
7 UnderAttic (Vented)
DINING/GREAT 30
Blown
588ft2
0.1
Wood
8 UnderAttic(Vented)
KITCHEN 30
Blown
209ft2
0.1.
Wood
9 UnderAttic(Vented)
BATH 30
Blown
50ft2
0.1
Wood
10 UnderAttic (Vented)
HALL 30
Blown
25 ft2
0.1
Wood
11 UnderAttic (Vented)
' FOYER 30
Blown
92 ft2
0.1
Wood
12 UnderAttic (Vented)
BEDROOM 3 30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT 19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Omt To Wall T�fpp
Cavity Width
Space Ft In
Height
Et In
Area
Sheathing Framing Solar
R-Vahle Eraction Ahqnr
Below
o
1
E Exterior Concrete Block-
Int InsuMASTER BE 4.1 16
0 8 0
128.0 ft2
0 0
0.3
0
2
W Exterior • Concrete Block-
Int InsuMASTER BE 4.1 7
d
0 8 0
56.0 ft2
0 0
0.3
0
_ 3
.
S Exterior Concrete Block-
Int InsuMASTER BE 4.1 14
0 8 0
112.0 ft2
0 0
.
0.3
0
4/21 /2020 10:04 AM
i
EnergyGauge® USA 6i 0.02 (Rev
1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT St1MMARV rNFrKi 'icT RRanDT
WALLS
Adjacent Cavity Space .Width
_
Height
Sheathing Framing
Solar Below
0
4
E
Exterior
Concrete Block - Int InsuMASTER BA 4.1 • 8
0
8 0
64.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block - Int Insul M. BATH 4.1 7.
0
8 0
56.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block - Int InsuBEDROOM 2 4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
_ 7
S
Exterior
Concrete Block- Int InsuDINING/GRE 4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
8
W
Exterior
Concrete Block- Int InsuDINING/GRE
_
4.1 20
i
0
8 0
160.0 ft2
0
0
0.3
0
9
W
Exterior
Concrete Block- Int Insul KITCHEN 4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
10
E
Exterior
Concrete Block- Int Insul BATH 4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
11
N
Exterior
Concrete Block- Int Insul FOYER 4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
12
N
Exterior
Concrete Block- Intinsul FOYER 4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_ 13
W
Exterior
Concrete Block- Int InsuBEDROOM 3 .4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block - Int Ins uBEDROOM 3 4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_ 15
N
Garage
Frame - Wood BEDROOM 3 11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Omt
DoorType Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed
to Worst Case.
/
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
'S 3
Metal Low-ESingle Yes 1.04 '0.29
N
32.4 ft2
1 ft 0 in
1 ft5 in
Drapes/blinds
Exterior5
2
E 5
Metal Low-ESingle Yes 1.04 0.29
N
6.9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low-ESingle Yes 1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-ESingle Yes 1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low-ESingle Yes 1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-ESingle Yes 1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft5 in
Drapes/blinds
Exterior5
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft? .26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000.254 1168.7 64.16
120.66
.0881
5
4/21 /202010:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition•(2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency ,
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 15
34.8 kBtu/hr cfm u6 1
sys#1
I
HOT WATER SYSTEM
# . System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 50 gal 60.9 gal
120 deg .
None
SOLAR HOT. WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
/ — Supply---
-- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handier
TOT
OUT QN RLF
Heat Cool
1 Attic
6 175 ft2 1 Attic
55 ft2 DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating Jan Feb
Mar
Mar
•A r
f 'Apr f
Ma Jun Jul
MaY Jun Jul
Auge
[ Aug
Sep
Oct H:Nov
f Oct Nov
Dec
HDec
Venting Jan Feb
Mar
[X] Apr [
May Jun Jul
[ ] Au
Se
[X] Oct Nov
Dec.`
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 78
r
78 78 78
78-
78
78 78 78
78
_
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78 78 78
78
PM
78
78 78
78 78 78
78
78
78 78 78
78
Heating(WD) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 66
66
Heating (WEH) AM
66
66 66
66 -66 68
68
68
68 68 68
68
PM
68.
68 68
68 68 . 68
68
68
68 68 .66
.66
MASS
Mass Type
Area
Thickness Furniture Fraction ,
Space
Default(81bs/sq.4.
0 ft?
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(81bs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(81bs/sq-ft.
ft2
ft
0.3
BEDROOM 2 '
Defaul48lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT RO
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
4/21 /202010'04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS .
Mass Type
Area Thickness Furniture Fraction
Space.
Default(8lbs/sq.ft.
ftz ft 0.3
BATH
Default(8lbs/sq.ft.
ftz ft 0.3
HALL
Default(8lbs/sq.ft.
ftz ft .. 0.3
FOYER
Default albs/s .ft.
ftz ft 0.3
BEDROOM.3
4/21/202010:04 AM EnergyGauge® USA6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
, ' ,
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND' INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT.. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A. continuous air barrier shall be installed in the building:envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in'the air barrier shall be sealed.
not be used as a sealingmaterial.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps.in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic space's shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the -cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum. .
Exterior thermal envelope insulation for framed
walls.shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim .joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including.
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be incontact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvente'd crawl spaces'shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations; and flue shafts opening to
exterior or unconditioned s ace shall be sealed. -
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the: available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on. exterior wall
tubs shall separate them;from the showers,and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
tioxes.or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots -that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed flee sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordancawith the provisions of ]CC-400:
4/21/202010:05 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant. Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy. Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2: Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity .
34.8
c) Area
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab-on=grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
1 OA1.
e) Dedicated heat pump with tank EF
2, Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type. and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier. installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required :by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I'certify that this home has complied with, the Florida Building Code, Energy .Conservation, through the above energy
saving features which will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address:of New Home:y C y \i City/FL Zip: FT. PIERCE. FL
4/21/202010:05:25 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1