A=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
5PAGING NOTE
ALL TRUSSES ARE TO BE SET
AT 2'-0: ON CENTER
EXCEPT A5 NOTED
i
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
A IF MULTIPLE PLY. All
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Span or less ® 30' to 60' Span
Spreader Bar AL
60 degrees
—\ Or less
i2 Tag �__ mpprox 2/3 to
TOL rle span /tip— O Line. 1/2 of Span.
9
RR To BCs'
EFEREFER TO SCSI
Truss. must be set this way if crone used.
Truss must be set this way if crone used.
s is an example. hour truss moy .not notch. This is an example; truss may not notch.
7rusInsist crane operator sets truss this way.
insist crone operator sets truss this way..
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. A
Al R HAN G71I—IE=R F�
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
Carrying Girder
For Truss to Truss
Connections see
., hanger/connector Nails must be as
shown. Guide tabs o
schedule in engineering Dome angle nails.
s package.
>s _ Carried Truss
SEAT PLATES BY CHAMBERS
d�
TRUSSES FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES RE BUILT 'F OR T-IAT MODEL.
AL ARRANJE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24' I LENGTH
I
A DO not `tand on trusses Until they are braced per BCSII & properly nailed to Straps & hangers L FABRICATION AGREEMENT
l .TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal description of the property where the trusses will be Installed Is: -
C L
19'-9" _— ._. ___._.._ 16-3" _ ^ I / The undersigned acknowledges and agrees:
1'
upset=1/4" heel=315116"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
12
4 00
to
-- 2.00 —
12
i
I
upset=1/4" lieel=3 15/16" INDICATES LOAD BEARING
PLUMB CUT END REQUIRED BY TRUSSES
i SUPPLIED BY BUILDER
2 x 4 Top Chord AT A HEIGHT OF 6-0"
WALL HEIGHT 8' ABOVE FINISHED FLOOR
END DETAIL: TYPICAL VAULT
4_
I
I®
I®
I
r
r
r
�1
'/
11001
I � 1
1
�
�
P
I
I
I I
/I I
1 I
1
f
II
_
PON
—
og-
Men
4V
1110
Zq�%00A
MIS
9041
ff NOR
FAA
F ON
FO
05A
IIIIII�1�
�_
®®
FIs
■®
It
■®_-
■_
�Ir
1110
/4%
%///lIIIi
%%/%!%I'////til�//.�/l1
/�I�///%iIa////a,iWZ//�.%
r
®I®I®I®I■I®I■�I�I■I®I■I®li�l®I®I®I®IE�►
PORCH®
••
O
C
1. TNsees will be made In strictaccordance with this truss placement diagram ayout,
I I I which Is the sole authority for determining. successful fabrication of the trusses.
All dlmensfons In this layout have been venfled by tits undersigned.
♦
1
1 � 1
♦
1
1
1
\�
1
.■I■I■II�I®I®�®I�I�I®I®
\ 1
♦1
'�`�1\II`
♦I
`
\ ,
1 1 Wes`\.\\\\,\\\�\\�\\\`\\\\,I\\`\
1
i \'
1
\I
�1
I.
\�
�
i
, teal.
I
I 1
11`
1 I
1 1
1
il`
I I
\
IN
�1
®o�o�o�so����a�000��0®��1\0_0��0����0�0�o�000w���
rrrr+ir�r►.��i wellr��.s.s�ars�l��'++�rrr
®_SIR111
_
Else.
as
46
joi
INS
111
`E
INS
Miss
I�//�
INS
1111111
t.... • • . . - •
IN
I
IaSL
111111
ail
IRS
��
09
A��"��
1 ♦I
�I
\\"1`\\\\.I\`\
\I �i\\\�II`\�
I\`\I
`\\`\i\Vi\,\\i\
1\"\`I��\\�"`\I��`t
®I®I®
10■I®ICI®I®I
I®I�
_I I
a 14'-4"
lop— V \
0
1
" l
1JED. AREAS ARE OF®R
FT
L CONCERN &MUST BE t
I PCH LE
ED CA�ErI1 01 MAY
INDICATE DEVIATION FROM
2.
.3. Unless written notice Is provided by certified mall to Chambers Truss within ten (10)
dayi of delivery the undersigned agrees that no backoharges will be allowed..ln the event
such written notice la fumlahed Chambers Trues shell have three (3) huness days In welch
: 'to begin repairs required, cr to substitute othat trusses, at Chambers opti n.
4. The undersigned acknowledges receipt of "SCSI 1-03" summary sheet by'IPI
e b site suitable for
eke N o
le a b er'e'res nslblll tom 1
b site. It tit ty
Is to o uy Do
6, Dellva J ry
delvery. Chambers Truss has the sole authority to detertnlne Iha suitability of the Job site or a
potion of the Job site for delivery. Chambers Truss will be responsible for dump delivery only.
The buyer Is responsible for additional deliveryexpenses It Chambers Truss has to redeliver
bawuaeJab site Ie not prepared Tor dellvary or buyer le not prepared for delivery of trusses.
Boyar Is responsible to Chambers Trues for towing cos16 duo to sUa conditions.
6. Puce as shown In paragraph 7 below Is sub at to change If any changes are, made in
this.larnia A $60 per hour fee for revisions may be charged by Chambers Truss,
7; Thls -Ise PURCHASE ORDER to Chambers,Truss of the sum agreed to, or If Ink
agreement a reasonable price. Invoice will be made on delivery and paid within terms of net
on dellvary. Invoice
may. be made at scheduled date of delivery If buyer Cannot accept
do,,, of fabricated Wssa. The undersigned agrees to pay Chombers.TNss reasonable
sttomey�s fee for collections In event of payment not timely made. 1.1r2 %per month servi
charge will be added for all sums not paid within terms. .
. S. Signature or Inttials anywhere on this sheet constltutes agreement to all terms herein.
9: In consideration of Chambers Truss extending Credit for this material the undersigned
uncendltionally guarantees payment when due of any and all Indebtedness owed to
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including ettpmeys fees, if default In payment for material be made by the
recipient.
10, In the event of any litigation concerning this agreement, the Items furnished hereunder
or payments related to herein, the, parties agree that the sole venue for any such action will
be Saint 6ucle County, Florida.
11. Design responslbllttlesare par -National Standard And Redbmmended GuHollnes On
Responsibilities For Construction using Metal Plate Connected Wood Trusses
ANSIrrPIWTCA 4.2002"`
DATED ..-..~
,SIGNED
Agp18aderbarmayhelegulredper"BCs11.03"b1'pre✓ "IrguryBdamago.
Multiple ply trusses must be fastened togothelr per englneering
before they are set failure to do so can result In roof collap4G,
Temporary and permanent bracing are required and can save life
and property and Is the responslblllty of the truss erector.
:Study the contents of the Information packet Included on delivery
I before setting trusses.
Trirsses must be setand braced porrdeslgn to prevExrtinjuryEr damagm
Trusses must be set plumb and square
Do riot set bunks or stack of plywood, roofing material or any
other cdincentrated loads on trusses, this Can cause collapse.
Do NOT SET TRUSSES USING THIS LAYOUT
CHAMBERS TRIJ;33 iNG
3105 Oleander Avenue
Fort Pierce; Florida 34982-6423
800-551-5932
port Pierce 772-465-2012 Fax 772-465.8711
VeroBeach 772S8SA04it Stuart 772-2863302
ect'sorA a0il `t,q,m`Present-,,,V&'y
s ulbledrawingClIt" t.ys;.NOi a
1'".,'double Check"
of the contractor.
The contractor shall remain responsible
for checking field measurements and
other constr'uctton coterie.. Architect's
apProvai coversgeneral roof shape,
review of truss strapping, and loading on
structure from gravit
Y and uplift loads and
their res at locations.
Approved By '
Date.
Bra en 8, 'Braden A.I.A. P,A.
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County SAINT LUCIE
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
9 Roofing Material Shingle or Shake
0 wry I Loading inPSF Roof R.D.L.
_ H — Top Chord Live 20
s c Top Chord Dead 7 4.2
0,,o I Bottom Chord Live 10 Non -Concurrent
o c Bottom Chord Dead 10 3
TOTAL Load 37 7.2
Duration Factor 1.25
B Wind Speed 165mph
y Top Chord C.B. Sheeting by builder.
Bottom Chord C.B. Sheeting by builder.
v Highest Mean Height 15'-0
Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
I�EV�EWEII� .L.=Restrainin Dead Load C B Continuous Brain
"`ODE IEWE . ESIGN CRITERIA shown above with the
o+ department and your engineer.
ST. LUCIE CO Wien Criteria is the responsibility of the
Buildin Designer and/or En ineer of Record.
Chambers Truss Inc. Drawing Name: M11392
Scale: 1 /4 = 1'
82 total trusses 15 • r diffe ant trusses.
MI 4: RLC A AD:
I
C RLC Reviewed B
y
Date:10/07/15 Revised:03/21/18
Vj FOR Revised:3/05/2020
QWYNNE BUILDING CORP.
DESCRIPTION:
WINDSOR -7-70s/
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
LANs -- 15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT IV111392
Nil
MiTek
�
RE: M11392
THE WINDSOR
0
Site Information:
Customer: Wynne Dev Corp Project Name: M11392
Lot/Block: Model: THE WINDSOR
Address: unknown Subdivision:
City St Lucie County State• FL
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
j
General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
1 Seal# Truss Name Date FILE
1 T19781803 A � 10/9/2020
2 T19781804 Al 10/9/2020 Copy
3 T19781805 A2 10/9/2020 ■
4 T19781806 A3 10/9/2020
5 T19781807 A4 10/9/2020
6 T19781808 A5 10/9/2020
7 T19781809 ATA 10/9/2020
8 T19781810 B 10/9/2020
9 T19781811 BHA 10/9/2020 REVIEWED D FOR
10 T19781812 GRA 10/9/2020 pp��®®
11 T19781813 J1 10/9/2020 CODE COMPLIANCE
13 T19781815 J5 10/9/2020 ST. LUCIE COUNTY
15 T19781817 KJ7 10/9/2020 BOCC
This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision
,,���� t t t ttt1��
AA
based on the parameters provided by Chambers Truss.
S
��� P....
• •' <e ���
Truss Design 9 n Engineer's Name: Albani, Thomas
�� O� ' •
My license renewal date for the state of Florida is February 28, 2021.
Florida COA: 6634
No 39380
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
'
shown (e.g., loads, supports, dimensions, shapes and -design codes), which were
given to MiTek. Any specific information!included is for MiTek
:.• AS TAT E OF : ��
O,
project
customers file reference purpose only, and was hot taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
i�T� ••. 0 R O P •• \���
�i s • • • • • ��
parametersfor the designer
verioathe
yn
51� N A� t.���
d of desiatte these designs
applicabilitys parametersarticular properly incorporate
verify PP tY 9 P P P Y� P 9
gn
1"
into the overall building design per ANSIITPI 1, Chapter 2.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 October 09, 2020
nnra-
1 of 1
Albani, Thomas
9
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T79781603
M11392
A
HIP
1
1
Job Reference o tional
Gnamners I russ, Inc., ton tierce, hL 8.24U s Mar v zuzu mi I eK Inausmes, IOC. I ue Mar 24 12:b4:Uf ZUZU Yage 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-KTRK2jb7uXlhmgejamLw33G2phzq_UFBTsBBV6zXjH_
�1-0-0 610-14 9- -0 , 14-11-0 20-2-13 26-0-0 28-1-2 , 35-0-0
-0-0 6 10-14 2-1-2 5-11-0 5-3-13 5-9-3 2-1-2 6-10-14 -0-0
4.00 12
4x8 = 2x3 II 3x6 = 4x4 = 4x8 =
2x3
d ..., S ,. 7 ..-, a ,.
Scale = 1:60.5
I I
3x4 — 3x4 = 3x6 = 6xB = 3x4 = 3x6 — 3x4 = 3x5
9-0-0 14-11-0
20-2-13
26-
35.0-0
9-0-0
5-11-0
5-3-13
5-9-3
9-0-0
Plate Offsets (X,Y)—
[2:0-0-14,Edge], [4:0-5-4,0-2-0], [8:0-5-4,0-2-0], [10:0-0-6,Edge]
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0�
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017frPI2014
CSI.
TC 0.57
BC 0.47
WB 0.94
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) I/deft
0.42 12-23 >572
0.37 12-23 >659
0.03 10 n/a
Lid
240
180
n/a
PLATES GRIP
MT20 244/190
Weight: 161 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0.
Max Horz 2=-97(LC 10) 1
Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12)
Max Grav 2=467(LC 17), 15=1596(LC'1), 10=685(LC 22)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-5-1 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-639/108, 34=396/0, 4-5=-967/776, 5-7=-967/776, 7-8=454/938, 8-9=-1009/1884,
9-10=-1265/2154
BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-1586/938, 10-12=-1971/1174
WEBS 3-17=-372/461,4-17=-272,451,4-154-1087/1002,5-15=336/386,7-14=-766/399,
8-14=-580/997, 8-12=-958/447,9-121-358/600, 7-15=-1329/2190
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Va'sd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to
13-11-6, Interior(1) 13-11-6 to 26-0-0, Extedor(2) 26, 0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at
joint 15 and 799 lb uplift at joint 10.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
® WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety lnrormaflon available from Truss Plate Institute, 2670 Crain F ighway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
March 24,2020
Job
Truss
Truss Type
City
Ply
T19781804
M11392
Al
SPECIAL
1
1
�THEWINDSOR
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:08 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-of7iF3blfgtYOgDv7Us9cGoCh5CAjz5KiVwkOZzXjGz
1-0-0 8-6-0 11-0-0 14-9-0 19-8-14 24-0-0 27-4-7 35-0-0 6-0-
-0-0 8-6-0 2-6-0� 3-9-0 411-14 4-3-2 3-0-7 7-7-9 -0-0
5x6 =
4.00 12
2x3 11
21 5
3x4 =
6 22
5x8 MT18HS =
Scale = 1:61.3
13 12
5x8 MT18HS =
3x6 = 3x5 = 2.00 12 302 =
LOADING (psf)
SPACING-
2-0-U
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017rrP12014 ,
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
CSI.
DEFL.
in (loc) Udefl Ud
PLATES
GRIP
TC 0.63
Vert(LL)
0.75 11-12 >563 240
MT20
244/190
BC 0.91
Vert(CT)
-1.21 11-12 >348 180
MT18HS
244/190
WB 0.77
Horz(CT)
0.35 9 n/a n/a
Matrix -MS
Weight: 155 lb
FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-7-7 oc puriins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
Max Horz 2=-117(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 1,2)
Max Grav 2=1349(LC 1). 9=1349(LC 11)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3209/2102, 34=3006/2024, 4-5=3022/2080, 5-6=3022/2080, 6-7=-4643/2994,
7-8=-5324/3364, 8-9=-5751/3700 '
BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657! 11-12=-2456/3908, 9-11=-3442/5478
WEBS 3-13=-425/410, 4-13=-354/571, 4-12=-362/617, 5-12=-269/279, 6-12=-1034/712,
6-11=-373/892,7-11=-897/1523,8-11=-404/435
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18: MWFRS (directional) acid C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joints) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 Ib uplift at joint 2 and 825 lb uplift at
joint 9.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall r
building design. Bracing indicatedIs to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss'systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781805
M11392
A2
SPECIAL
1
1
Job Reference o floral
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:09 2020 Page 1
ID:_kfiGCA6bx7j2SylHDXFw7ye3KX-HsZ4SPcOQB?P?zo5hBO08ULMuVYnSPxUxgglY?zXjGy
1-0-0 8-6-0 1M-0 14-9-0 22-M 27-4-7 35-0-0 6-0-
-0- 8.6-0 4-6-0 7-3-0 5-0-7 7-7-9 0-0
Scale = 1:61.3
5x6 = 3x4 =
4.00 12 4 21 5
5x8 =
22 6
12
3x4 = Sx8 = 3x12
3x6 = 2.00 12
10-0-0
1"'
22-M
24-6-8
35-0-0
'
10-0-0
4-g-0
7-3-0
1
2.6-8
10-5-8
Plate Offsets KY)—
[2:0-0-6,Edge], [6:0-4-0,0-2-3], [8:0-1-15,Edge]
LOADING (pso
SPACING- 2-0-01
CSI.
DEFL.
in (loc) Vdefi L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25,
TC 0.66
Vert(LL)
0.72 10 >585 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-0.94 10-19 >447 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.86
Horz(CT)
0.34 8 n/a n/a
BCDL 10.0
Code FBC2017frP12014 ,
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-15
oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 8=0-8-0
Max Horz 2=136(LC 11)
Max Uplift 2=-825(LC 12), 8=-825(LC 12)
Max Grav 2=1349(LC 1), 8=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3211/2064, 3-4=-3017/1998, 4-5=-2580/1800, 5-6=3379/2225, 6-7=5242/3250,
7-8=-5759/3665
BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=1990/3441,
8-10=-3410/5485
WEBS 3-13=-420/418, 4-13=-427/688, 4-12=-337/551, 5-12=-777/605, 5-11=-465/925,
6-11 =-391/277, 6-1 0=-1 318/2268, 7-1 0=-503/530
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) acid C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding,
electronically signed and
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Albani, Thomas, PE
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Using a Digital SignatUfe.
will fit between the bottom chord and any other members.
Printed Copies Of this
7) Bearing at joint(s) 8 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify
document are not considered
capacity of bearing surface. I
signed and sealed and the
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signature must be verified
joint 8.
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cott 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with Mrrek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding Me
fabrication, storage, delivery, erection and bracing of trusses and truss. systems, see ANSI/rP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781806
M11392
A3
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:10 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-127SgIdOBS7Gd7NIFvvehhuYXvu2Bsnd9pPr4RzXjGx
1-0 q 8-6-0 15 0-0 20-0-0 24-6-8 27-4-7 35-0-0
-0-0 8-6-0 "I 1 -0 4-6-8 2-9-15 7-7-9 0-0
4.00 12
5x6 = 4x5 =
14 13 ""
3x5 = 2x3 II 5x6 =
2.00 12
Scale = 1:62.3
3x12 zz
m
OI�r n.
0
Plate Offsets (X,Y)—
[2:0-1-6,Edge], [3:0-3-0,Edge], [8:0-3-0,0-3-4], [9:0-1-15 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.60
Vert(LL)
0.73 11 >572 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-0.97 11-20 >432 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.83
Horz(CT)
0.36 9 n/a n/a
BCDL 10.0
Code FBC20171TP12014,
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 7-12
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-155(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
Max Grav 2=1349(LC 1), 9=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3256/2031, 4-5=2426/1588, 5-6=2680/1790, 6-7=2829/1832, 7-8=5320/3257,
8-9=-5720/3554
BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=-2935/5103,
9-11=-3302/5445 i
WEBS 4-14=0/329,4-13=-897/636,5-12=-316/661, 6-12=-317/616, 7-12=2727/1643,
7-11 =-1 072/1939, 8-11 =-390/391
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-1-0-0 to 2-6-0, Interlor(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom (chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20j0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss'to bearing plate capable of withstanding 825 Ib uplift at joint 2 and 825 lb uplift at
joint 9. 1
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 qualify Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Celt 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
city,
Ply
i
T19781807
M11392
A4
SPECIAL
1
1
�THEWINDSOR
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:112020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-DEhgtSeexIF7FHyUpcQtEvQjTIDGwGhnOT90duzXjGw
�1-0-0 8-6-0 14-9-0 17-0-0 18-0 24-0.8 27-4-7 35.0-0 3,6-0-q
-0-0 8 6-0 '3-0 2-3 0 0-0 fi 6 8 2-9-15 7-7-9 0-0
o'
4.00 12
2x3
5x6 = 4x6 =
6 7
Scale=1:62.3
16 15 6x10
3x5 = 2x3 II 5x8 = 3x12 =
2.00 12
8 6-0 14-9-0 18-0-0 24 6-8 35-0-0
8-6-0 6-3-0 3-3-0 6-6-8 10-5-8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.80
13
>528
240
MT20
244/190
TCDL 7.0
Lumber DOL
1.26
BC 0.95
Vert(CT)
-1.05
13
>400
180
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.98
Horz(CT)
0.39
11
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014 ,
Matrix -MS
Weight: 172 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3 WEBS
REACTIONS. (size) 2=0-8-0, 11=0-8-0
Max Horz 2=-175(LC 10)
Max Uplift 2=-825(LC 12), 11=-825(LC 12)
Max Grav 2=1349(LC 1), 11=1349(LC' 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3253/1989, 3-5=2435/1560, 5-6=2399/1639, 6-7=2217/1501, 7-8=-2380/1519,
8-10=-5361/3228, 10-11=-5716/3480
BOT CHORD 2-16=1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154,
11-13=-3232/5441 i
WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-163/427, 6-14=-309/604,
6-15=-315/409, 8-14=-3146/1901, 8-,13=-1034/1946, 10-13=-343/333
Structural woad sheathing directly applied or 2-6-14 oc purlins.
Rigid ceiling directly applied or 2-2-0 oc bracing.
1 Row at midpt 8-14
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=O.18; MWFRS (directional) and C-C Exterior(2) -1 -0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 11 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 11.
i
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 8834
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety lnformaflon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
City
Ply
THE WINDSOR
Puss
T19781808
M11392
SPECIAL
16
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:13 2020 Page 1
ID:_kflGCA6bx7j2Syl HDXFw7ye3KX-9dpbinfuTNVrUb6twl SLJKWOV6vFOEp3meVhmzXjGu
1-0-0 8-6-0 l 14-9-0 17-6.0 24-6-8 27-4-7 35-0-0 6-0
-0-0 8-6_0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 -0-0
�1
0
3x5 =
5x8 MT18HS 11
4.00 12
14 13
2x3 II l 5x10 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017ITP12014
LUMBER -
TOP CHORD 2x4 SP M 31 'Except'
14,8-11: 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
6-12: 2x4 SP M 30
OTHERS
2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-825(LC 12), 10=-825(LC 12)
Max Grav 2=1349(LC 1), 10=1349(LC 1)
2.00 12
35-0-0
Scale = 1:60.3
3x12
CSI.
DEFL.
in (loc) I/deft L/d.
PLATES
GRIP
TC 0.81
Vert(LL)
0.8012-13 >526 240
MT20
244/190
BC 0.92
Vert(CT)-1.2812-13 >329 180
MT18HS
244/190
WB 0.74
Hcrz(CT)
0.36 10 n/a n/a
Matrix -MS
Weight: 160 lb
FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 6-12
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=-2397/1763, 6-7=-5452/3624, 7-9=-5398/3482,
9-10=-5732/3689
BOT CHORD 2-14=-1865/3040, 13-14=-1865/304d, 12-13=-1223/2137, 10-12=-3431/5459
WEBS 3-14=0/303, 3-13=-861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526,
7-12=-323/388,9-12=-321/306
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70111; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1 -0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom Ichord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20Apsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of trusstobearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
1
0
This item has been
electronically signed and
sealed by Alban!, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
- .. - --- — -- --- ....... _._ _ ........ _._-. __ i_-.. ----- — — __....... _.
® WARNING - VeHfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the appllcablllty of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss;systems, see ANSUTP/f Quality Criteria, DSB.89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE WINDSOR
T19781809
M11392
ATA
COMMON
5
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:14 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-dpMzW7gWEgdi61g3UkzarX2EkWJA7jTD4RN3DCzXjGt
1-0-0 8-4-0 12-11-0 17 6 0 22-1-0 26-8-0 35-0-0 6-0-
-0-0 8.4-0 4-7-0 4-7-0 4-7-0 4-7-0 8.4-0 -0-0
4.00 12
4x5 =
Scale=1:59.5
17 '" 15 "" "' 14 '" 12
3x6 — 2x3 II 4x6 = 3x8 = 2x3 II 3x6 =
3x8 =
4x6 =
LOADING (psf)
SPACING-
2-0-0i
CSI.
DEFL.
in (loc)
Vdefi
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.33 14-15
>999
240
TCDL 7.0
Lumber DOL
1.25
BC 0.68
Vert(CT)
-0.64 14-15
>652
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.59
Horz(CT)
0.13 10
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014I
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
PLATES GRIP
MT20 ' 244/190
Weight: 166lb FT=0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-2-15 oc bracing.
Max Horz 2=-179(LC 10)
Max Uplift 2=-775(LC 12), 10=-775(LC!12)
Max Grav 2=1399(LC 1). 10=1399(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3404/1963, 3-5=2807/1637, 5-6=-2801/1739, 6-7=2801/1739, 7-9=-2807/1637,
9-10=-3404/1963
BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188i 14-15=-966/2053, 12-14=-1739/3188,
10-12=-1739/3188
WEBS 6-14=-560/968, 9-14=-681/524, 6-15=-560/968, 3-15=-681/524
NOTES- '
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=7011; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directorial) and C-C Exterior(2) -1-0-0 to 2-6-0, Interlor(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60 1
3) 100.Olb AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom 'chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.bpsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at
joint 10.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not ��AA
a truss system. Before use, the building designer must verify the applicabllity of design parameters and property Incorporate this design Into the overall .•Y�-
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible peisonal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
1 N
I�
d
Job
Truss
Truss Type
Oty
Ply
WINDSOR
I
T19781810
M11392
B
COMMON
2
1
�THE
I
Job Reference o tional
cnamoers I russ, Inc., t-on Pierce, t-L 6.24U s Mar 9 2o2U Min eK Inoustnes, Inc. Tue Mar 24 12:54:15 2020 Page 1
ID: kfiGCA6bx7j2Sy1HDXFw7ye3KX-5OwLjSh8?_IZuFF2SVpOlbSRwk4sA4MJ57cmfzXjGs
1-0-0 8-3-5 14-0-0 17-6-0 21-0-0 26-8-11 35-0-0 6-0-
-0-0 8-3-5 5-8-11 3 6 0 3-0-0 5-8-11 8-3-5 -0-0
Scale = 1:59.3
4.00 12 3x6 =
6
1 n
ta,
O
3x4 = 2x3 II 3x6 = 3x4 = 3x4 = 3x6 = 2x3 II 3x4 =
0
35-0-0
LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft Lid PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TIC 0.34 Vert(LL) -0.11 14-15 >766 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.24 17-20 >715 180
BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.03 10 n/a We
BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 149 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural woad sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. Al bearings 0-8-0.
(lb) - Max Horz 2=-179(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC
12)
Max Grav All reactions 250 lb or less at joint(s) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC
1)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-945/572, 5-6=181/256, 6-7=-181/258, 9-10=-945/574
BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-;14=-393/858, 10-12=-393/858
WEBS 3-17=-5/301, 3-15=-81 9/591, 5-15=-277/325, 7-14=-277/326,9-14=-819/592,
9-12=-5/301
NOTES- '
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
This item has been
DOL=1.60
electronically signed and
3) This truss has been designed for a 10.0 psf bottom'chord live load nonconcurrent with any other live loads.
sealed by Albani, Thomas, PE
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
using a Digital Signature.
5) Provide mechanical connection (by others) of trusslto bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at
Printed copies of this
joint 15, 453 lb uplift at joint 14 and 371 lb uplift at Joint 10.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall r
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE WINDSOR
I
T19781811
M11392
BHA
BOSTON HIP
1
1
Job Reference (optional)
Gnam hers truss, Inc., ron rterce, rL d.z4U S mar a zuzu mi I eK mousmes, Inc. i ue mar z4-Iz:D4:l t zuzu rage I
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb7HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
15.6.0 21-6.0
1-0-0 7-M 9-6-0 11-0-0 13-6-01 -017-6-0 19-6-0 21-0-0 23-6-0 25.6-0 28-0-0 35-0-0 6-0-0
-0-0 7-" 2-6-0 2-" 2-0-0 0-6 1-6-0 2-0-0 2-0-0 1-6-00-6 2-0-0 2-0-0 2-6-0 7-M -0-0
Scale = 1:62.4
TOP CHORD MUST BE BRACED BY END JACKS,
ROOF DIAPHRAGM, OR PROPERLY CONNECTE 4.00 12 4x4 =
PURLINS AS SPECIFIED.
57 15 58 17
56 12 59
3x6 55 9 20
54 8 60 22 3x6
5x12 =53 4 6 x6 = 3x4 2,01 5x12
3 11 16 19 1 23 26 697
63
1
52 4
r;
N1 2 28 29 N N
35 42 43 34 44 33 45 46 47 48 32 49 31 50 51 30
3x6 = 6x8 = 6x8 = 3x6 = 3x4 =
3x4 =
I
7-0-0 14-0-0 21-0-0 28-0-0 35-0-0
7-0-0 7-0-0 7-0-0 7-0-0 7-0-0
Plate Offsets (X,Y)— [3:0-64,0-1-121,[32:0-3-8 0-3-01
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefi Ud PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a
BCDL 10.0 Code FBC2017/TP12014i Matrix -MS Weight: 208 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32
JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=179(LC 7)
Max Uplift All uplift 100 Ib or less at joint(§) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8).
28=-434(LC 8)
Max Grav All reactions 250 lb or less at joints) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1).
28=626(LC 1)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1692/1103, 3-4=-105/259, 27-28=1129/710, 3-5=-041/520, 5-7=436/514,
7-10=436/514, 10-11=-436/514, 11-13=-436/514, 13-16=436/514, 16-18=436/614,
18-19=436/514, 19-21=-382/412, 21-23=-382/412, 23-25=-382/412, 25-27=-387/418
BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039
WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=8101782, 19-32=772/745,
27-32=-1484/1044,9-10=-463/453,20-21=462/454
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom' chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20,Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at
joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28.
8) Graphical purlin representation does not depict the, size or the orientation of the purin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at
7-0-0, 158 Ib down and 206 Ib up at 9-0-12, 158 lb down and 206 Ib up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 Ib
down and 206 Ib up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206
lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at
25-114, and 158 Ib down and 206 Ib up at 27-11 4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 Ib down at 9-0-12, 69
Ib down at 11-0-12, 69 lb down at 13-0-12, 69 Ib tlown at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at
19-11-4. 69 lb down at 21-11-4. 69 lb down at 23-11-4. and 69 lb down at 25-11-4. and 69 lb down at 27-11-4 on bottom chord.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
The designfselection of such connection device(§)Is the responsitnrity of otFiers----- ----------- —'
® Am fac8l$fElblalftmatainvat5dFaisir fAlto) of bias MBEFORE USE.
D61gntiAwigrgpp 6vijh MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a trO�yrt��spllyphWt4Yhg designer must verify the applicability of design parameters and property Incorporate this design Into the overall �•
bul in esh n. g I I to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty,
Ply
THE WINDSOR
T19781811
M11392
BHA
BOSTON HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 2
1 D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM 1 K3EfmPcjgXzXjGq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 36-39=-20, 1-3=-54, 3-15=-54, 15-27=-54, 27-29=-54
Concentrated Loads (lb)
Vert:35=-373(F) 30=-23(F) 42=-23(F) 43=-23(F) 44=-23(F) 45=-23(F) 46=-23(F) 47=-23(F) 48=-23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F)
54=-1 18(F) 55=-118(F) 56=-118(F) 57=-118(F) 58=-118(F) 59=-118(F) 60=-118(F) 61=-118(F) 62=-118(F) 63=-118(F)
I
®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall t
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T19781812
M11392
GRA
HIP
1
1
�THEWINDSOR
!
Job Reference (optional)
�.nanruers I rubs, 111c., runt rrerce, rL o.Z4u s mar s ZUZU mi I eK mousunes, Inc. I ue mar Z4 1Z:o4:1`J ZuZu rage l
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYb17yXOVouLyEj5gvQzxjGo
MID,14-11.0 21-5-2 28.0-0 35-0-0 __ 0,
1-0-0' 7-0-0 i 7-11-0 6-6-2 6 614 7-0.0 -0-0
Scale = 1:60.3
5x12 MT18HS =
4.00 12 3x5 II 3x6 = 4x8 =
3 22 1 23 24 25 4 26 27 5 28 629 30 31 32
4x8 =
7
I�
15 33 . 34 14 35 13 36 37 38 1239 11 40 41 10
3x4 = 2x3 11 3x6 = 5x14 = 3x4 = 4x6 = 2x3 11 3x5 =
7-0-0 14-11-0
21-5-2
28-0-0 35-M
7-0-0 7-11-0
6-6-2
6-6-14 7-0.0
Plate Offsets (X,Y)—
[3:0-9-0,0-2-8],[6:0-3-8,0-2-0],[7:0-5-4,0-2-4] [13:0-4-0 0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL,
in (loc) Udefl Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.94
Vert(LL)
0.30 10-21 >792 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.67
Vert(CT) -0.30 10-12 >812 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr NO
WB 1.00
Horz(CT)
0.09 8 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014 '
Matrix -MS
Weight: 153 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-9-5 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-6-8 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 6-13
4-13: 2x6 SP No.2
2 Rows at 1/3 pts 3-13
REACTIONS. (size) 2=0-8-0, 13=0-8-0, 8=0-8-0 ,
Max Horz 2=-78(LC 6)
Max Uplift 2=448(LC 8), 13=-2442(LC' 8), 8=-1159(LC 8)
Max Grav 2=755(LC 17),13=3223(LC-1),8=1225(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1534/729, 3.4=-1052/1347, 4-6=1052/1347, 6-7=-1946/1834, 7-8=-2978/2565
BOT CHORD 2-15=-586/1423,13-15=-596/1464,12-13=-1710/1946,10-12=-2359/2830,
8-10=-2329/2789
WEBS 3-15=-159/733, 3-13=-2917/1869,4-13=-848/801,6-13=-3504/3050, 6-12=-430/666,
7-12=-940/731, 7-10=-489/690
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
This Item has been
4) All plates are MT20 plates unless otherwise indicated.
electronically
ally Signed and
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed Albans, Thomas, PE
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
using a Digital Signature.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at
Printed copies of this
joint 13 and 1159 lb uplift at joint 8.
document are not Considered
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at
signed and sealed and the
7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down
signature must be verified
and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-114, 90 lb down and 155 lb up at
19-11-4, 90 lb down and 155 lb up at 21-114, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-114, and
on any electronic copies.
203 lb down and 329 lb up at 28-0-0 on top chord, land 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb
Thomas A. Alban! PE No.39380
down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at
MlTek USA, Inc. FL Cart 6834
17-0-12, 63 lb down and 3 lb up at 17-114, 63 lb down and 3 lb up at 19-114, 63 lb down and 3 lb up at 21-114, 63 lb down and
6904 Parke East Blvd. Tampa FL 33610
3 lb up at 23-114, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-114 on bottom chord. The
Date:
design/selection of such connection device(s) is the responsibility of others. •
March 24,2020
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
®IC�Jt;A}:sltat�eld®rA�rs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
•
MaMtVf1W9relga�uv2h MTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
aWss system. Bef re se, the building designer must verify the applicability of design and incorporate this design Into the
parameters property overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781812
M11392
GRA
HIP
1
1
Job Reference (optional
unamoers I russ, Inc., Tort Tierce, I-L
tf.z4u s mar a zuzu Nii i eK mcustnes, inc. i Lie mar z4 iz:a4: I a zuzu rage z
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvQzXjGo
LOAD CASE(S) Standard I
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-7=-54, 7-9=-54, 16-19=-20
Concentrated Loads (lb)
Vert: 3=-147(B) 7=-147(B) 15=-452(B) 13=40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=90(B) 28=-90(B) 30=-90(B) 31=-90(B)
32=-90(B)33=-40(B)34=-40(B)35=-40(B)36=-40(B)37=-40(B)38=40(B)39=-40(B)40=-40(B)41=40(B)
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability, of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTF11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
T19781813
M11392
AMONO
TRUSS
8
1
�THEWINDSOR
Job Reference o tional
cnamoers I russ, Inc., ion Fierce, rL u.z4u s mar a zuzu net I eK inousmes, Inc. I ue Mar z4 iz:54:ia zuzu rage i
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYblBwXAho7vyEj5gvQzXjGo
-1-0.0 1-0-0
Scale = 1:6.1
3x4 =
LOADING (psf)
SPACING- 2-0-01
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25,
TC 0.18
Vert(LL)
-0.00
5
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25'
BC 0.02
Vert(CT)
-0.00
5
>999
180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2017frP12014 '
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD 20 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=48(LC 12)
Max Uplift 3=-4(LC 9), 2=-140(LC 12)
Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections. i
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall�e
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss,systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
'
T19781814
M11392
J3
MONO TRUSS
8
1
Job Reference (optional)
GnamoerS I russ, Inc., rorr vierce, r•L tf.24U 6 mar v ZUZU mi I eK maustnes, Inc. I ue Mar Z4 1Z:b4:ZU ZUZu rage i
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-SzkEmAIHgWOrgg8Dq?4_SoIMZxUHXa95SNgNRszXjGn
1-0-0 3-0-0
1-0-0 3-0-0
Scale = 1:9.4
3x4 =
LOADING (psf)
I
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Well
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL)
0.01
4-7
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.19
Vert(CT)
-0.01
4-7
>999
180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MP
Weight: 11 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Meichanical
Max Harz 2=85(LC 12)
Max Uplift 3=-54(LC 12). 2=-147(LC 12)„ 4=-4(LC 12)
Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 llb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. .
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Va4--128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift at joint 4. I
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
I
® WARNING - Vedfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overalls
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
T19781815
M11392
J5
MONO TRUSS
8
1
�THEWINDSOR
Job Reference o tional
Chambers I fuss, Inc., Fort Pierce, FL 8.24U s Mar 9 ZUZU MITeK Industries, Inc. Tue Mar 24 12:54:21 ZUZU Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-wAHc WlvbgWiRpjPOibDeOrOoKYG1PFhlawzlzxGm
1-0-0 6-0-0
1-0 0 5-0-0
Scale = 1:12.7
3x4 =
i
5.0-0
5.0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.73
Vert(LL) 0.07
4-7 >863 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.70
Vert(CT) -0.06
4-7 >964 180
BCLL 0.0
Rep Stress Incr YES I
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 17lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=123(LC 12)
Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12)
Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd= 128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections. 1
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
I _
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. '
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall ISO
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUiP/14uality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Trtiss Type
City
Ply
THE WINDSOR
T19781816
M11392
J7
MONO TRUSS
24
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL j 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:21 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-wAHcWlvbgWiRpjPOibDeOrSnKmPGIPFhlawzlzXjGm
-1-0-0 7-0-0
1-0-0 7-0-0
Scale: 3/4'=l'
3x4 =
7-0-0
7-0-0
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.47
Vert(LL)
0.17
4-7
>494
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.2.5
BC 0.39
Vert(CT)
-0.19
4-7
>447
180
BCLL 0.0
Rep Stress Incr
YES 1
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=161(LC 12) 1
Max Uplift 3=-153(LC 12), 2=-211(LC 12), i4=-12(LC 12)
Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3)
I
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (li) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C'C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf;on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections. 1
5) Provide mechanical connection (by others) of truss to be plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at
joint 2 and 12 lb uplift at joint 4. 1
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall�e
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safetylnformadon available from Truss Plate Institute, 2670 Crain Highway! Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781817
M11392
KJ7
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:22 2020 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-OMr BsmXM7eZ3zlbyQ7SAONhnk9g?RvOwhJUWIzXjGI
-1-5-0 6-8-12 9-10-1
1-5-0 6-8-12 3-1-5
Scale = 1:20.6
3x4 = Zxa II 5
30 =
6-8-12 9-10-1
6-8-12 3-1-5
LOADING (pso
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.20
TCDL
7.0
Lumber DOL
1.25
BC 0.26
BCLL
0.0
Rep Stress Incr
NO !
WB 0.24
BCDL
10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 2=0-11-5, 5=Mechanical
Max Horz 2=192(LC 8) 1
Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=-238(LC 8)
Max Grav 4=156(LC 13),2=379(LC 1), "61(LC 1)
FORCES. (lb) -Max. CompJMax. Ten. -All farces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-838/366
BOT CHORD 2-7=487/798, 6-7=487/798
WEBS 3-7=0/307, 3-6=-920/561
DEFL. in (loc) Udefl Ud PLATES GRIP
Vert(LL) -0.04 7-10 >999 240 MT20 244/190
Vert(CT) -0.08 7-10 >999 180
Horz(CT) 0.01 5 file n/a
Weight: 38 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at
joint 2 and 238 lb uplift at joint 5.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plo
Vert: 2=0(F=27, B=27)-to-4=-133(F=-39, B=-39), 8=0(F=10, B=10)4o-5=-49(F=-15, B=-15)
This item has been
electronically signed and
sealed by Alban!, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
I
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ��®®
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall i�Y�•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPH Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Hlghway,!Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Symbols
Numbering System
General Safety Notes
PLATE LOCATION AND ORIENTATION
3/4' Center plate on joint unless x, y
offsets are indicated.
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
Failure to Follow Could Cause Property
Damage or Personal Injury
Dimensions are in ft-in-sixteenths.
1. Additional stability bracing for truss system, e.g.
Apply plates to both sides of truss
1 2 3
diagonal or X-bracing, is always required. See BCSI.
and fully embed teeth.
TOP CHORDS
2. Truss bracing must be designed by an engineer. For
1/ �r
0'
C1-2 C2-3
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
16
WEBS At4
�,� N � 03.
O
bracing should be considered.
Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
U
4. Provide copies of this truss design to the building
O 0-
00
designer, erection supervisor, property owner and
FOr 4 x 2 orientation, locate
C7-8 C6a
all other interested parties.
plates 0- yie from outside
BOTTOM CHORDS
5. Cut members to bear tightly against each other.
edge of truss.
8 7 6 5
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
This symbol indicates the
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
locations are regulated byANSI/rPI 1.
required direction of slots in
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
7, Design assumes trusses will be suitably protected from
connector plates.
THE LEFT.
the environment in accord with ANSI/TPI 1.
'Plate location details available In M'tTek 20/20
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
software or upon request.
9. Unless expressly noted, this design is not applicable for
PLATE SIZE
PRODUCT CODE APPROVALS
use with fire retardant, preservative treated, or green lumber.
ICC-ES Reports:
10. Camber is a non-structural consideration and is the
The first dimension is the plate
responsibility of truss fabricator. General practice is to
4 x 4 width measured perpendicular
ESR-1311, ESR-1352, ESR1988
camber for dead load deflection.
to slots. Second dimension is
ER-3907, ESR-2362, ESR-1397, ESR-3282
11. Plate type, size, orientation and location dimensions
the length parallel to slots.
indicated are minimum plating requirements.
LATERAL BRACING LOCATION
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
Indicated_ by symbol shown and/or _ _ _
by text in the bracing section of the
Trusses are designed for wind loads in the plane of the
truss unless otherwise -shown.--
13. Top chords must be sheathed or purrns provided at
spacing indicated on design.
output. Use T or I bracing
if indicated.
Lumber design values are in accordance with ANSI/TPI 1
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
section 6.3 These truss designs rely on lumber values
BEARING
established by others.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
Indicates location where bearings
approval of an engineer.
(supports) occur. Icons vary but
reaction section indicates joint
© 2012 MiTekO All Rights Reserved
17. Install and load vertically unless indicated otherwise.
_ _
number where bearings occur.
Min size shown is for crushing only.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
Industry Standards'
19. Review all portions of this design (front, back, words
ANSIITP11: National Design Specification for Metal
and pictures) before use. Reviewing pictures alone
is not sufficient.
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
®
20. Design assumes manufacture in accordance with
BCSI: Building Component Safety Information,
MiTek
ANSVTPI 1 Quality criteria.
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
21.The design does not take into account any dynamic
Connected Wood Trusses.
MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020
or other loads other than those expressly stated.