HomeMy WebLinkAboutAPPROVED OC Weatherlock Tile & Metal ver 2020Businesslk
4 '! pf
nal Regulation
SCIS Home Log In . User Registration Nat Topics Submit Surcharge Sta[s & Facts Publicatlons Contact Us 6CIS Site Map Links ':. Search
a
product Approvaldbp
r (A USER; Puhllc User
Product 6ggroyal Menu ❑ Product or App kcatign SQsrSh > &piication List n Application DOUR
FL # FL9777-R13
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Small One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg. keeler@ owe nscomIng.com
Authorized Signature Greg Keeler
g reg. keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date
12/31/2024
Validated By
Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year {of Standard}
Equivalence of Product Standards
Certified By
rL9777 R R14002.10a Eval We I Non-HVHZ
finaLWf
5tandard
year
ASTM ❑ 1970
2015
ASTM ❑ 226
2009
ASTM G 155
2013
TAS 103
2020
UL1897
2012
Sections from the Code
Product Approval Method Method i Option b
Date Submitted
10/22/2020
Date Validated
10/23/2020
Date Pending FBC Approval
10/28/2020
Date Approved
12/15/2020
Date Revised
12/17/2020
Summary of Products I
FL #
9777.1
Model, Number or Name f Description
Weatherlock G
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
9777.2 1 Weatherlock G (High Tear)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
9777.3 1 Weatherlock MAT
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ; No
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
9777.4 Weatherlock MAT
Limits of use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
9777.5 Weatherlock Metal
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
9777.6 Weatherlock Metal
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Weatherproofing Underlayment
Installation Instructions
FL9777 R13 II OCR14QQ2.10a 2020 FBC Eval Weatherlock
NNi n=HVHZ Fnal.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R13 AE OCR14002_10a 2020 FBC Eval Weatherlock
Non-HVHZ final-Rdf
Created by Independent Third Party: Yes
Weatherproofing Underiayment
Installation Instructions
FL9777 R13 II OCR14002,10a 2020 FBC Eval Weatherloc
V fin I.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R13 AE OCR14002.10a 2020 FBC Eval Weatherlock
Non-HVHZ final.pdf
Created by Independent Third Party: Yes
Waterproofing Underayment
Installation Instructions
FL9777 R13 II OCR 14002.10b 2020 FBC Eva Weatherloc
HVHZ final_pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R13 AE QCR14002.10b 2020 FBC Eva Weatthgrlock
HVHZ final,piff
Created by Independent Third Party: Yes
Waterproofing Underlayment
Installation Instructions
FL9777 R13 II OCR14002.10a 2020 FBC Eval Weatherlock
Non-HVHZ finpl.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
EL2777 R13 AE OCR14002,10a 2 20 FBC Eval Weatherlock
Non-HVHZ final.pdf
Created by Independent Third Party: Yes
Weatherproofing Underlayment
Installation Instructions
7 R13 II OCRI4002,10a 2020 FBC Eval Weatherlock
Non-HVHZ final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R13 AE 020 PRr rvnierlock
Created by Independent Third Party, Yes
Weatherproofing Underlayment
Installation Instructions
rL9777 R13 11 OCR14002.10FBC Eval h dock
HVHZ final&df
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Design Pressure: N/A
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R13 AE iJCR14002.10b 2020 FBC Eval Weatherlock j
HVHZ final-W J
Created by Independent Third Party: Yes
f9777.7 Weatherlock Specialty Tile & Metal I Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-142.5
Other: See evaluation report for limits of use.
Installation Instructions
FL9777 R13 12 OCR14002.lOa 2020 FSC EyaJ_NLeatherlock
Non-HVHZ final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R13 AE OCRi4002.10a 2020 FBC Eval Weatherlock
Nan-HVHZ final.r2c[f
Created by Independent Third Party: Yes
Contact Us :: 2501 Blair Stone Road, Ta1!ahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EE0 employer. ,riggright 2007-2013 State of FlorLdi :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a publc-retards request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditlonal mail. If you have any questions, please contact 850.487.1395. "Pursuant to section 455.275(S),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
provided may be used for offlclal communication with the licensee. However emall addresses are publlc record. If you do not wlsh to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hsm.
Product Approval Accepts:
Credit Card
Safe
Certificate of Authorization ion bur 2982e
CREEK17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, fH EDITION (2020)
Manufacturer: OWENS CORNING Issued October23, 2020
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465
www. owe n s corning . com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110))
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1, 1507.1.1
Properties;
Physical properties
REFERENCES
Enti
Report No.
Standard
Year
PRI Construction
Materials Technologies (TST5878)
NEI-039-02-02-01
ASTM a 1970
2015a
PRI Construction
Materials Technologies (TST5878)
NEI-042-02-01 REV2
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST5878j
NEI-045-02-01
ASTM G 155
2013
PRI Construction
Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2013
PRI Construction
Materials Technologies (TST5878)
NEI-093-02-02
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST5878)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction
Materials Technologies (TST5878)
0CF-237-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2011
PRI Construction
Materials Technologies (TST5878)
OGF-252-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST5878)
OCF-293-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST5878)
OCF-296-02-02
ICC-ES AC 188
2012
ICC-ES AC 48
2012
PRI Construction
Materials Technologies {TST5878}
OCF-297-02-01.1
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST5878)
OCF-318-02-01
ASTM D 1970
2015a
PRI Construction
Materials Technologies (TST5878)
OGF-320-02-01
ASTM G 155
2005a2013
PRI Construction
Materials Technologies (TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction
Materials Technologies (7ST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction
Materials Technoiogies (TST5878)
CCF-355-02-01
UL 1897
2012
PRI Construction
Materials Technologies (TST5878)
137870120
TAS 103
2020
PRI Construction
Materials Technologies (TST5878)
1378TO121
ASTM D 1623
2019
TAS 103
2020
Determined to be equivalent to ASTM D 226-09, Type I
and II
FL9777-R13
1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TF-cHNICAL SI`RVICEs, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
❑WENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Underlayments (Non-HVHZ)
WeatherLock® G
WeatherLock® G is an ASTM ❑ 1970 self -adhered underlayment constructed from SBS
(Brentwood, NH or
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
Houston, TXj
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLockED G is permitted to be used as prescribed in FBC Section 1507.1.1 and
Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof
deck shall be limited to a maximum 30 days.
WeatherLock® Mat
WeatherLock® Mat is an ASTM ❑ 1970 self -adhered underlayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in
Houston, TX}
1-sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal
dimensions of 3-ft x 66.7-ft.
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 and
Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on the roof deck
shall be limited to a maximum 30 days.
WeatherLockO Metal
WeatherLockOD Metal is an ASTM D 1970 self -adhered underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock(@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 and
Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on the roof deck
shall be limited to a maximum 90 days.
WeatherLock®
WeatherLock@ Specialty Tile & Metal is an ASTM 0 1970, TAS 103 and. FRSAlTRI
Specialty Tile & Metal
Florida High Wind Concrete and Clay Tile Installation Manula, Sixth Edition compliant
(Brentwood, NH)
self -adhered underlayment constructed from SBS modified asphalt and surfaced with a
non -woven polyester fabric. The product is supplied in 2.14 sq. rolls with nominal
dimensions of 3-ft x 71.3-ft.
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1 and Table 1507.1.1.1. Weatherl-ockS Specialty Tile & Metal is
permitted to be used with adhered clay or concrete tile roofing using Dupont TILE
BONDTM Roof Tile Adhesive. Exposure on the roof deck shall be limited to a maximum
90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock® G
WeatherLock® G (High Tear) is an ASTM ❑ 1970 self -adhered underlayment used as an
(High Tear)
alternative to ASTM D 226, Type II roofing felt. The underlayment is composed of SBS
(Houston, 730
modified asphalt with a fiberglass mat internal reinforcement and is surfaced with
granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls
with nominal dimensions of 3-ft x 65-ft.
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 and Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on
the roof deck shall be limited to a maximum 30 days.
OCR14002.10a FL9777-R13 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which [his report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock& tlnderlayments (Non-HVHZ)
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All underdayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6" and laps staggered rain. 6-ft.from preceding course.
Additionally, if applying WeatherLockO Specialty Tile & Metal, end laps shall be primed
with ASTM ❑ 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches
across the width of the lap.
It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment).
Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when installed on
roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WINd RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504,9
Underlavment Svstem No.1 — WeatherLock Specialty Tile & Metal Only
Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnalled along the
selvage with minimum 12ga., 1-114-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.1fla FL9777-R13 Page 3 of 4
This evaluation report is provided for State of Florlda product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLvcki& Undertayments (Non-HVHZ)
1] This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
Ioad pressures for components and cladding.
10) Maximum Design Pressures for a given underayment shall meet or exceed the design wind Ioad$
determined for the roof assembly.
11 j All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
�-o-0 llR
.•`1�'G'�E�(,•E 1VS IDS .�
w No 7.4021
w
*.
3 STATE CF
'r•,��s �O N At �E�,'�
CERTIFICATION OF INDEPENDENCE
2020.10.23
09:42:37
-04'Q0'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, ar ccntrolled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
CeIy.ZC9IiY�fi[rk1
END OF REPORT
FL9777-R13
4of4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.