HomeMy WebLinkAboutAPPROVED SARKAR roofing permit infoe ST. LUCIE 'CORKS L, e ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETETHE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,SA5,8,7 - Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B,D 1A4587 Concrete or Clay Tile A, B, D, E 1,2,9„4,8,Gj Metal Roofs A, B, D 1,2,S4A6,7' Wood Shingles and Shakes A, B,D 1,2A,6,6,7 Other As Applicable 1zaq r�B7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _ Max. Design Pressure, from the specific product approval system: Deck: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_" oc @ Lap, It Rows_ ®_" oo Zone l_" oc @ Lap, It Rows— ® _" ao Zone 2, oc @ Lap, # Rows _ ®_" m Zone 3—" oc @ Lap, If Rows_ ®_ co Number of Fasteners Per Insulation Board: Zone 1'rZone 1:_Zone 2_Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Section ❑ (Steep Slope Roof System) Roof Systern Manufacturer: JA TAYLOR ROOFING 5V CRIMP Notice of Acceptance Number: FL#17443.1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: -57 Zone 2e: -57 Zane 2n:-9 1 one 2r: -9� Zone 3e-91 Zone 3r:-1 28 Deck Type: FFL7YWOCID Type Urideriayment DUVENS CORNING WEATHERCOCK TILE &METAL FL#9777,7 Roof Slope- 5 1 2 Insulation: Fire Barrier: Ridge Ventilation? Fastener Type &. Spacing: 6" FIELD 14" PERIMETER, BD RING SHANK NAILS Adhesive Type: Type Cap Sheet: Mean Root` Height: 15' FT Roof Covering; METAL Type & Sipe Drip 2"x2" Edge: ST. LUCIE �,:-40RKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values For M, with the values from Mr. If the Mr values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RA512T (Zone 1: _X1._= _J_Mg: _=Mn_ Product ApprovalM (Zone 2e: _X.1_= Mg-=M Product ti_ Approval Mr (Zone 2n: '_xl_= _)-Mg_=Mm,_ Product Approval Mr (Zone 2r. _x x_=Mg:_=Mm_ Product Approval Mr (Zone 3e: '_xt_= , 1-M7._=Mft_ Product Approval Mf (Zone 3r: _X1._= _J-Mgt_=Met _ Product Approval Mr Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Prndurt Annrnval M, M, required Moment Resistance - Mean Roof Height Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4-12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 wmx be useo in conjunction Wrtn a Rat of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F'values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: _x L x W:=) -W:cos r=Fn Product Approval F' (Zone 2e: _x L= x W:=_-W:_ cos r=Fa• Product Approval F' (Zone 2n:x LxW:=)-W:_cos r=Fan_ Product Approval F' (Zone 2r._x L=xW:=_)-W: cos r =Fri Product Approval F' (Zone 3e: _x L =x W:=-W:_Cos r= F,ar_ Product Approval F' (Zone 3r._x L_xW:=_J-W:cos r=F,3r_ Product Approval F' Whereto Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job SRe Roof Slope 0 lob Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mr Product Approval Attachment Resistance Mr Product Approval Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' ProductApproval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval TIIe Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.