Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED Evaluation Report_Underlayment
NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
Polyglass USA, Inc.
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330
Evaluation Report 3m-PLYG-20-FBCER.A
FL5259-R32 (HVHZ)
Date of Issuance: 12/21/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments, for use in FBC HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen, P.E.
on 12/21/2020. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
©2019 NEMO ETC, LLC
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 2 of 11
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
RAS 115, TAS 110 Material standard ASTM D226 2009
TAS 110 Material standard ASTM D1970 2015
TAS 110 Material standard TAS 103 2020
TAS 110 Material standard ASTM D6163 2015
TAS 110 Material standard ASTM D6164 2011
TAS 110 Material standard ASTM D6222 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Date Entity Examination Reference Date
ERD (TST 6049) TAS 114(J) 11757.08.01-1 8/13/2001 NEMO (TST 6049) ASTM D1970 4-PLYG-18-004.03.18 3/29/2018
ERD (TST 6049) TAS 114(C) P1740.01.07 1/4/2007 NEMO (TST 6049) ASTM D1623, TAS 103 4S-ICP-18-001.07.18-R1 7/23/2018
ERD (TST 6049) ASTM D1623, TAS 103 P11030.11.09-1 11/30/2009 NEMO (TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 1/24/2019
ERD (TST 6049) TAS 117(B) / TAS 114(C) P11030.11.09-2 11/30/2009 NEMO (TST 6049) ASTM D6222 4S-PLYG-18-002.05.19-C 5/20/2019
ERD (TST 6049) ASTM D4977 / TAS 103 P11030.11.09-3 11/30/2009 NEMO (TST 6049) TAS 103 4S-PLYG-18-004.10.19-G 10/8/2019
ERD (TST 6049) ASTM D1970, D4798 P37300.10.11 10/19/2011 NEMO (TST 6049) TAS 103 4S-PLYG-18-004.10.19-I 10/8/2019
ERD (TST 6049) TAS 103 P40390.08.12-1 8/6/2012 NEMO (TST 6049) TAS 103 4S-PLYG-18-004.10.19-L 10/9/2019
ERD (TST 6049) ASTM D1623, TAS 103 P40390.08.12-2 8/7/2012 NEMO (TST 6049) TAS 103 4S-PLYG-18-004.12.19-F 12/18/2019
ERD (TST 6049) ASTM D1623, TAS 103 C41420.09.12-3 9/11/2012 NEMO (TST 6049) TAS 103 4j-PLYG-19-SSUDL-02.A 1/2/2020
ERD (TST 6049) ASTM D6509 P37590.03.13-1-R1 2/5/2013 NEMO (TST 6049) ASTM D1970, D4798 4S-PLYG-18-004.01.20.H 1/14/2020
ERD (TST 6049) TAS 114(J) P39680.03.13 3/4/2013 NEMO (TST 6049) ASTM D1970, D4798 4S-PLYG-18-004.01.20.K 1/14/2020
ERD (TST 6049) ASTM D6164 P37590.03.13-3A 3/6/2013 NEMO (TST 6049) TAS 103 (tile slippage) 4S-PLYG-18-004.01.20.A 1/16/2020
ERD (TST 6049) ASTM D6164 P37590.07.13-1 7/2/2013 NEMO (TST 6049) ASTM D6164 4S-PLYG-18-004.01.20.B 1/16/2020
ERD (TST 6049) ASTM D4601 P45940.09.13 9/4/2013 NEMO (TST 6049) TAS 103 PLYG-SC15855.05.20.A 5/29/2020
ERD (TST 6049) ASTM D1623, TAS 103 P45270.05.14 5/12/2014 NEMO (TST 6049) TAS 103 4j-PLYG-20-SSUDL-01 7/6/2020
ERD (TST 6049) ASTM D1623, TAS 103 6020.09.14-6 9/8/2014 NEMO (TST 6049) ASTM D6222 4q-PLYG-19-SSMBB-05.A 7/23/2020
ERD (TST 6049) TAS 103 P44360.10.14-R1 10/7/2014 NEMO (TST 6049) ASTM D4798, D1623 4j-PLYG-19-SSUDL-05.A 9/10/2020
ERD (TST 6049) ASTM D1970, D4798 P43290.10.14 10/17/2014 NEMO (TST 6049) ASTM D1970 4j-PLYG-20-SSUDL-05.A 9/30/2020
ERD (TST 6049) TAS 114(J) P39680.03.13 3/4/2013 NEMO (TST 6049) TAS 103 4j-PLYG-20-SSUDL-05.C 9/30/2020
ERD (TST 6049) ASTM D1970, D4798 PLYG-SC10130.06.16-1 6/27/2016 NEMO (TST 6049) TAS 103 4j-PLYG-20-SSUDL-11.A 10/21/2020
ERD (TST 6049) ASTM D1623, TAS 103 PLYG-SC10130.06.16-2 6/27/2016 NEMO (TST 6049) ASTM D1970, D4798 4S-PLYG-18-004.12.19.D 10/27/2020
ERD (TST 6049) TAS 103 PLYG-SC10130.06.16-3 6/27/2016 NEMO (TST 6049) ASTM D1623, TAS 103 4p-ICP-20-SSLAP-01.A 12/15/2020
ERD (TST 6049) TAS 103 (tile slippage) PLYG-SC13040.12.16 12/27/2016 UL (QUA9625) Quality Control Service Confirmation (FL) 09/13/2018
ERD (TST 6049) TAS 103 (tile slippage) PLYG-SC12115.08.17 8/8/2017 UL (QUA9625) Quality Control Service Confirmation (TX) 11/07/2019
ERD (TST 6049) TAS 103 PLYG-SC13035.08.17 10/31/2017 UL (QUA9625) Quality Control Florida BCIS Current
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 3 of 11
4. PRODUCT DESCRIPTION:
Product Material Standard Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced, SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced, SBS modified bitumen base sheet
4.3 Elastoflex S6 G ASTM D6164
TAS 103 (partial)
FL, PA Polyester-reinforced, SBS modified bitumen cap sheet
4.4 Elastoflex S6 G FR ASTM D6164
TAS 103 (partial)
FL Polyester-reinforced, SBS modified bitumen cap sheet
4.5 Polyflex G ASTM D6222
TAS 103 (partial)
FL Polyester-reinforced, APP modified bitumen cap sheet
4.6 Polyflex G FR ASTM D6222
TAS 103 (partial)
FL Polyester-reinforced, APP modified bitumen cap sheet
4.7 Polyflex SA P ASTM D6222
TAS 103 (partial)
FL, TX Polyester-reinforced, APP modified bitumen cap sheet
4.8 Polyflex SA P FR ASTM D6222
TAS 103 (partial)
FL, TX Polyester-reinforced, APP modified bitumen cap sheet
4.9 Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate surface
4.10 Polystick MTS Plus ASTM D1970
TAS 103
FL, NV, PA,
TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, surfaced with poly-film
surface
4.11 Polystick TU Max ASTM D1970
TAS 103
FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane with a 190 g/m2 polyester fabric surface
4.12 Polystick TU P TAS 103 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a granular
surface
4.13 Polystick TU Plus ASTM D1970
TAS 103
FL, PA, TX Nominal 80-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with a polyester fabric
surface
4.14 Polystick XFR ASTM D1970
TAS 103
NV, TX Nominal 80-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, surfaced with a textured
film surface
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance
unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC Non-High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 4 of 11
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section: TAS 110(S10),
RAS 115
TAS 110(S11),
RAS 118, 119 & 120 RAS 133 TAS 110(S11) RAS 130
Underlayment Asphalt
Shingles
Clay and Concrete Tile Metal Slate or Slate-
Type Shingles Wood Mechanical Attach Adhesive-Set
Elastobase
Yes
(Alternate to
D226, Type II)
Yes
(as Base Sheet,
See 5.8)
Yes
(as Base Sheet,
See 5.8)
Yes
(Alternate to
D226, Type II)
Yes
(Alternate to
D226, Type II)
Yes
(Alternate to
D226, Type II)
Elastobase P
Yes
(Alternate to
D226, Type II)
Yes
(as Base Sheet,
See 5.8)
Yes
(as Base Sheet,
See 5.8)
Yes
(Alternate to
D226, Type II)
Yes
(Alternate to
D226, Type II)
Yes
(Alternate to
D226, Type II)
Elastoflex S6 G No Yes Yes
(See 5.6.1) No No No
Elastoflex S6 G FR No Yes No No No No
Polyflex G No Yes Yes
(See 5.6.1) No No No
Polyflex G FR No Yes No No No No
Polyflex SA P No Yes Yes
(See 5.6.1) No No No
Polyflex SA P FR No Yes No No No No
Polystick IR-Xe Yes No No No Yes Yes
Polystick MTS Plus Yes Yes No Yes Yes Yes
Polystick TU Max No Yes Yes
(See 5.6.1) Yes No Yes
Polystick TU P No Yes No No No Yes
Polystick TU Plus Yes Yes Yes
(See 5.6.1) Yes Yes Yes
Polystick XFR Yes Yes No Yes Yes Yes
5.6.1 Adhesive-set tile is limited to use of the following underlayment / tile-adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE-ADHESIVE COMBINATIONS1
Underlayment Adhesive Florida Product
Approval
Polystick TU Max or Polystick TU Plus DAP Foam “Touch ‘n Seal
StormBond Roof Tile Adhesive” NOA 20-0309.05
Polystick TU Max or Polystick TU Plus Dupont “Tile Bond™ Roof Tile
Adhesive” FL22525
Elastoflex S6 G, Polyflex G, Polyflex SA P, Polystick TU Max or Polystick TU
Plus
ICP Adhesives and Sealants
“Polyset® AH-160” NOA 17-0322.03
Polystick TU Max or Polystick TU Plus ICP Adhesives and Sealants
“Polyset® RTA-1” NOA 18-0131.02
1 Refer to Tile Manufacturer’s or Adhesive Manufacturer’s Florida Product Approval for Overturning Moment Resistance Performance.
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 5 of 11
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates (designed to meet wind loads for project)
Type Primer Material(s)
Polystick IR-Xe, Polystick MTS Plus,
Polystick TU Max, Polystick TU P,
Polystick TU Plus, Polystick XFR,
Polyflex SA P or Polyflex SA P FR
self-adhering
Deck ASTM D41 structural concrete
Base Sheet N/A ASTM D226, Type II felt, Elastobase, Elastobase P
Elastoflex S6 G or Elastoflex S6 G
FR hot asphalt Deck ASTM D41 structural concrete
Base Sheet N/A ASTM D226, Type II felt, Elastobase, Elastobase P
Polyflex G or Polyflex G FR torch-applied Deck ASTM D41 structural concrete
Base Sheet N/A Elastobase, Elastobase P
5.8 Attachment Limitations:
Refer to Section 6
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base Mechanically attached 30
Polystick IR-Xe Mechanically attached 90
Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick
XFR Any type (per Table 1) 180
Elastoflex S6 G, Polyflex G or Polyflex SA P Adhesive-set tile roof system 180
Elastoflex S6 G, Elastoflex S6 G FR, Polyflex G, Polyflex G FR, Polyflex SA P or
Polyflex SA P FR Mechanically attached UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Staging Slope
Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) Prohibited without battens
Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12
Polystick MTS Plus
Flat 6-tile stack (4 over 2) 5:12
Lugged 6-tile stack (4 over 2) 4:12
Polystick TU Max
Flat 6-tile stack (4 over 2) or 10-tile stack 7:12
Lugged 6-tile stack (4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat or Lugged 6-tile stack (4 over 2) 7:12
Polystick TU Plus
Flat or Lugged 6-tile stack (4 over 2) 7:12
Flat or Lugged 10-tile stack 6:12
Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 6 of 11
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Approved Assemblies:
6.3.1 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Underlayment mechanically fastened to deck
Underlayment: One or more plies of Elastobase or Elastobase P with a minimum 4-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate-type shingles, wood
shakes or wood shingles.
6.3.2 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Cap Ply: Elastoflex S6 G applied in hot asphalt or
Polyflex G torch-applied or
Polyflex SA P, self-adhering
and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive-set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.3 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Cap Ply: Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch-applied or
Polyflex SA P FR or Polystick TU P, self-adhering
and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 7 of 11
6.3.4 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Cap Ply: Polystick IR-Xe self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate-type shingles, wood shakes or wood shingles.
6.3.5 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate-type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
6.3.6 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 8 of 11
6.3.7 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Plus, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
6.3.8 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap-edges and 12-inch o.c.
in a grid-pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max or Polystick TU Plus, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved adhesive-set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.9 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap-edges and 18-inch o.c. in two (2)
equally spaced, staggered center rows.
Cap Ply: Elastoflex S6 G applied in hot asphalt or
Polyflex G torch-applied
and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive-set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 9 of 11
6.3.10 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap-edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Cap Ply: Polyflex SA P, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive-set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.11 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap-edges and 18-inch o.c. in two (2)
equally spaced, staggered center rows.
Cap Ply: Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch-applied
and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
6.3.12 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap-edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Cap Ply: Polyflex SA P FR or Polystick TU P, self-adhering, self-adhering and back-nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 10 of 11
6.3.13 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P felt with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap-edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate-type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
6.3.14 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap-edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
6.3.15 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap-edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self-adhering and back-nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Plus, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
NEMO|etc.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 11 of 11
6.3.16 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32” plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap-edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max or Polystick TU Plus, self-adhering and back-nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved adhesive-set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.17 Deck Type 3: Structural concrete, non-insulated
Deck Description: Min. 2,500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Underlayment: Elastoflex S6 G applied in hot asphalt or
Polyflex G torch-applied or
Polyflex SA P, self-adhering
Surfacing: FBC HVHZ Approved adhesive-set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.18 Deck Type 3: Structural concrete, non-insulated
Deck Description: Min. 2,500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self-adhering
Cap Ply: Polystick TU Max or Polystick TU Plus, self-adhering
Surfacing: FBC HVHZ Approved adhesive-set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4
herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL LLC – QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -