HomeMy WebLinkAboutAPPROVED, SECTION 1525 ROOFING FORMSROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1525
High Velocity Hurricane Zones Uniform Permit
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS BELOW:
Roof System
Required Sections of the Permit
Application Form
Attachments Required See List
Below
Clo.o7w—Slope Application
A,B,C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A,B,C
4,5,6,7
s haltic Shingles
Concrete or Clay Tile
A,B,D
1,2,4,5,6,7
A,B,D,E
2,3,4,5,6,7
Metal Roofs
A,B,D
1,2,3,4,5,6,7
Wood Shingles and Shakes
A,B,D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1.
Fire Directory Listing
2•
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component Product Approval
5.
Municipal Permit Application
6.
Owner's Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing / Calculation Documentation
GAZoning 20091Forms and Sample documents%Website Documents'. Build ingi.Forms%hv_hurricane roof .app.pdf Modified: 07.17.2015
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1525
High Velocity Hurricane Zones Uniform Permit
Section A (General Information
Permit Number:
Contractor's Name: FHIA, LLC _
Job Address: 4703 Juanita Ave Fort Pierce FL 34946
® Low Slow
® Asphaltic Shingles
❑ New Roof
ROOF CATEGORY
❑ Mechanically Fastened Tile
❑ Metal Panel/ Shingles
❑ Prescriptive BUR-RAS 150
0 Re -Roofing
Low Slope Roof Area (SF)
607 So Ft
ROOF TYPE
❑ Mortar / Adhesive Set Tile
❑ Wood Shingles/ Shakes
❑ Recovering ❑ Repair
ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF)
3685 Sq Ft
Section B (Roof Plan)
❑ Maintenance
Total (SF)
4292 Sq Ft
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow
drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and
location of parapets.
SEE ATTACHED
DRAWINGS FOR
ROOF DETAILS
G:17_oning 20WForms and Sample documentslWebsite Documents%BuildingkFormslhv,hurricane_roof app.pdr Modified: 07.17.2015
t,
4703 Juanita Ave, Fort Pierce, FL 34946-1041 OTENDED COVERAGE 3/11/2020
Pitch Diagram
Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 4
Disclaimer: With Extended Coverage, only the predominant pitch may be noted due to resolution o photo. Refer to pitch table for
more information. 6c-* Vs I
lq!�r_'CR 1.
"AICI L 1�
��„ZIIe gtec"', :56Z 8
4W
4-,
E
. N s
ILI 7
Note: This diagram contains labeled Pitches for facet areas larger than 20.0 Aguare feet. In some cases itch labels have been removed for
readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. + and +9). Blue shading indicates a pitch o 3/12 and greater.
Gray shading indicates Flat, 1112 or 2/12 pitches.
Disclaimer: This report was produced using EagleView Extended Coverage Technology, Due to a variety or reasons including, but not limited to: tree
coverage, poor images, low photo resolution or other blockages, this report DOES NOT offer an accuracy guarantee. EagleView recommends that
anyone using this report field verify the yellow -shaded sections.
w .;. 2008-2021 EagleVrew Technologies, I and PKmmetry International Corp. —All Rights Reserved Protected b European Patent
Report: 38859208 covered b one or more o US. Patent Nos. 9,078,436; T, 145,578: #, I70,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; %67D.961. 5
8,542,88Q 9,244,589; 9,329,749; 9,599,466. Other Patents Pending.
Florida Home Improvement Assoc Page 6
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1525
High Velocity Hurricane Zones Uniform Permit
Section C ( Low Sloped Roof Systems)
Fill in Specific Roof Assembly Components and
Identify Manufacturer Fastener Spacing for Anchor/ Base Sheet
(If a component is not used, identify as "NA")
System Manufacturer: CERTAINTEED CORP Field 8— "oc@LAP.#Rows 3 @ 8 'oc
*Product Approval # _ FL16709.1 Perimeter s=`oc@LAP.#Rowse@ 6 'oc
Design Wind Pressures, From RAS 128 or Calculations
Garner 4 "oc@LAP.#Rows 3 @4 "oc
*Pmaxl: -42.8 Pmax2: -71.7 Pmax3: -108
*Max: Design Pressure, From the Specific Product
Approval System.
'Not required for prescriptive RAS 150 systems.
Approval System: -60
Deck: WOOD
Type: WOOD
Gauge/ Thickness: "
Slope: "
Anchor/ Base Sheet & No. of Ply(s): NAILBA,9F SA
Anchor/ Base Sheet Fastener Bonding Material:
1 1 /4 IRS NAILS & TIN CAPS
Insulation Base Layer: NIA -
Base Insulation Size and Thickness: N/A
Base Insulation Fastener/ Bonding Material:
NIA
Number of Fasteners Per Insulation Board
(From N.O.A. or R.A.S. 150 Table 2)
Field: __NM. Perimeter:. N!A_ Corner: WA
Illustrated Components Noted and Details as
applicable
Wood blocking, Gutter, Edge Termination,
Stripping, Flashing, Continuous Cleat, Cant Strip,
Base Flashing, Counter- Flashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height,
Height Base Flashing, Component Material,
Material Thickness, Fastener Type, Fastener
Spacing, or Submit Manufactures Details that
Comply with RAS I 1 I and Chapter 16
STUCCO
Top Insulation Layer: URETHANE CAULK
Top Insulation Size and Thickness: N/A CENTER FLASHING
Top Insulation Fastener/ Bonding Material: GALV. 26 GA FLASHING I
NIA PLY -..A 4- O/C NAILS
Base Insulation Size and Thickness: GLASSBASE rNDRok
NAILBASEBase insulation Fastener/ Bonding Material: 1518
LOOSELAID 3' X 3'
Ply Sheet(s) and No. of Ply(s): PI YRASE
Ply Sheet Fastener/ Bonding Material:
SELF ADHERING 26 GA GALVANIZED DRIPEDGE NAILED 4 OIC W 1
Top Ply: Fi! INTAST1C A CAP Fib UL
Top Ply Fastener/ Bonding Material
SELF ADHERED
Surfacing: N/A --
1' FT. Parapet
Hei ht
12'
MOD BIT
FLASHING
CEMENT
FT Mean
Height
G:1Zoning 20091Forins and Sampic documentslWebsite Documents\Buiiding\Forms�.hv hurricane roof app.pdf Modified: 07.17.2015
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1525
High Velocity Hurricane Zones Uniform Permit
Section D (Steen Sloped Roof System)
NOTE: Items 3 & 4 are not required for shingles with NOA
1. Roof System Manufacturer:
2. Notice of Acceptance Number:
FL5444.1
3. Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Pmax 1: -39.1 Pmax2: -68.1
Roof Slope:
4 ,t : 12"
Steen Sloped Roof System Description
Deck Type: WOOD 5/8"
Pmax3: -1 fl6.7
Type Underlayment: CERTAINTEED WINTERGAURD NOA# FL30046.1
Insulation: NIA
Ridge Ventilation? \
YES
Mean Roof Height 9 "
Fire Barrier: N/A
1 1/4 RS NAIL 6" OC@LAPS 12"
Fastener Type & Spacing: OC t- FIELD. 2 ROWS
Adhesive Type: N/A
Type Cap Sheet: NIA
Roof Covering: ASPHALT SHINGLES
Type & Size Drip Edge: 3 x 3 GLAVANIZED 26GA
GAZoning 2009'.rorms and Sample documents'..Website Documents. Building rormslhv hurricane roof app.pdf Modified: 07.17.2015