Loading...
HomeMy WebLinkAbout213038-1pd Pool Backfill - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 CONTRACTOR: JOB LOCATION: J SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 April 22, 2021 5174 Tree Top Trail Fort Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # : 213038-1pd/CF/jo PERMIT #: 2012-0713 NUC # 234 Nuc Model: MC -DR Nuc Serial #: MD60308234 PO: #9740 - Young ITEM TESTED Pool Backfill Compaction TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1 North 0'-1' 50 108.3 110.7 97.8% 2 1'-2' 50 - " 95.0% + 3 2'-3' 45 - " 95.0% + 4 3'-4' 45 - it 95.0% + 5 West 0'-1' 50 108.5 110.7 98.0% 6 1'-2' 45 - if 95.0% + 7 2'-3' 45 - " 95.0% + 8 3'-4' 45 - it 95.0% + 9 South 0'-1' 50 108.0 110.7 97.6% 10 1'-2' 50 - if 95.0% + 11 2'-3' 50 - " 95.0% + 12 3'-4' 45 - 95.0% + Soil Description: Brown Sand In Place Moisture: 9.7% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 110.7 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Plumbed Backfill Respectfully Submitted: This item has been electronically signed and sealed by Bryan E. Dahlke, PE FL, Lic. 81439 on the date stated directly to the right using a digital signature. Printed copies of this documents are not considered signed and sealed and the signature must be verified on any electronic copies. Digitally signed by Bryan E Dahlke Date: 2021.04.23 10:02:38-04'00' W 1 IG.V E G 111.0.._.l_.._.L_.._I._..�.._..�.._...' H I I I I T D R110.0 1—.._.�_.._ ._.._�._.. I.._.. . .._... ' P Y I I I I I I I I I C 109.0 _. _.L_.._I._..�.. �.._.. F I I I I I 108.0 I I I I I 107.0 �.._.�_.._.�._.._�._.. --i.._.. -F .._.. 9 10 11 12 13 14 15 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the pool backfill in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the poolbackfill has been altered from the approved inspected condition. Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 4/23/2021 Email to: St Lucie Building Department; loudenmary@aol.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE