HomeMy WebLinkAboutPAJ4 SPEC SHEET..426 41 1707 05 06/19Specifications subject to change without notice. UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1−phase, 60 Hz REFRIGERATION CIRCUIT •Environmentally balanced R-410A refrigerant •Liquid refrigerant filter driers •Copper tube/aluminum fin condenser and evaporator coils EASY TO INSTALL AND SERVICE •Light weight, compact construction ideal for manufactured housing and residential applications •Hand holds built into the unit base pan •Compact, fully self-contained, electric cooling unit with horizontal supply and return ducts •Easy panel accessibility for maintenance and installation •Accessory electric heaters with single point connections •Designed to be serviced from both the side and front •Cabinet air leakage less than 2.0% at 1.0 inch W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C., when tested in accordance with ASHRAE Standard 193 BUILT TO LAST •Vibration isolation provides quiet operation. Compressors have internal over current protection •Direct-drive multi-speed, blower motor standard on all models •No-rust base pan with integrated drain pan standard on all units •Durable pre-painted steel cabinet •Louvered coil enclosure for protection against vandalism and hail damage •Aerodynamic fan blade design reduces the overall sound •All models have factory installed tin-coated copper evaporator coil. (identified with letters TP in the 11th and 12th positions in the model numbers) LIMITED WARRANTY* • 10 year parts limited warranty (including compressor and coils) * 5 years parts limited warranty if not registered within 90 days of original installation. See warranty certificate for complete details and restrictions. UNIT PERFORMANCE DATA Model Number Nominal Tons COOLING Unit Dimensions Height x Width x Depth inches (mm) Operating Weight lbs (kg) Net Capacity BTU/h @ 95°F(35°C)SEER EER PAJ424000KTP0B 2 22,400 14 11.5 30-1/8 x 51 x 32 (765 x 1295 x 813)217 (98) PAJ430000KTP0B 2.5 28,600 14 11.5 30-1/8 x 51 x 32 (765 x 1295 x 813)234 (106) PAJ436000KTP0B 3 34,200 14 11.5 30-1/8 x 51 x 32 (765 x 1295 x 813)255 (116) PAJ442000KTP0A 3.5 41,000 14.5 11.5 34-1/8 x 51 x 32 (867 x 1295 x 813)275 (125) PAJ448000KTP0A 4 47,000 14 11.5 42-1/8 x 51 x 32 (1070 x 1295 x 813)318 (144) PAJ460000KTP0A 5 54,000 14 11.3 42-1/8 x 51 x 32 (1070 x 1295 x 813)344 (156) PAJ4 Product Specifications As an Energy Star® Partner, International Comfort Products has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. Use of the AHRI Certified TM Mark in- dicates a manufacturer’s participation in the program. For verification of certi- fication for individual products, go to www.ahridirectory.org . 2 426 41 1707 05Specifications subject to change without notice. MODEL NOMENCLATURE MODEL SERIES 1 2, 3 4 5,6 7,8,9 10 11,12 13 14 15 P AJ 4 36 000 K TP 0 A 1 P = Package AJ = Air Conditioner 4 = 14 SEER 24 = 2 Tons 30 = 2.5 Tons 36 = 3 Tons 42 = 3.5 Tons 48 = 4 Tons 60 = 5 Tons NOMINAL COOLINGCAPACITY 000 = no factory heat NOMINAL HEATING BTUH (input) K = 208/230−1−60 VOLTAGE TP − Tin Plated Copper Evaporator Main Tubes FACTORY INSTALLED 0 = Standard FEATURE CODE Sales Model Digit Engineering Digit AHRI* CAPACITY RATINGS Cooling Capacities and Efficiencies UNIT SIZE NOMINAL TONS STANDARD CFM NET COOLING CAPACITY AT 95°F (35°c) (Btuh) EER†SEER** 24 2 800 22400 11.5 14 30 2.5 1000 28600 11.5 14 36 3 1200 34200 11.5 14 42 3.5 1400 41000 11.5 14.5 48 4 1600 47000 11.5 14 60 5 1850 54000 11.3 14 LEGEND dB---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance * Air Conditioning Heating & Refrigeration Institute † At "A" conditions--80°F (26.7°C) indoor db/67°F (19.4°C) indoor wb & 95°F (35°C) outdoor db. ** Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or AHRI Standards 210/240---08, 270-1995. Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80°F (26.7°C) db, 67°F wb (19.4°C) indoor entering---air temperature and 95°F db (35°C) outdoor entering---air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. A−Weighted Sound Power Level (dBA) − AHRI STANDARDS 270−1995 UNIT SIZE STANDARD RATING (dBA)TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 125 250 500 1000 2000 4000 8000 24 71 51.7 55.2 58.2 62.0 55.6 49.4 44.0 30 73 60.4 56.6 61.7 64.0 57.4 54.9 46.4 36 75 57.7 61.6 63.9 65.5 60.0 54.4 49.5 42 77 64.8 68.3 72.9 72.2 68.2 62.6 53.1 48 76 58.4 61.9 65.3 65.5 59.7 55.0 47.4 60 80 72.9 65.4 68.8 70.5 65.2 60.5 50.9 426 41 1707 05 3Specifications subject to change without notice. PHYSICAL DATA UNIT SIZE 24 30 36 42 48 60 NOMINAL CAPACITY (ton)2 2.5 3 3.5 4 5 SHIPPING WEIGHT (lb) (kg) 286 130 298 136 329 150 352 160 368 167 402 183 COMPRESSOR TYPE SCROLL REFRIGERANT R­410A REFRIGERANT QUANTITY (lb) QUANTITY (kg) 4.5 2.0 4.8 2.1 6.8 3.0 5.7 2.6 6.3 2.9 7.5 3.4 METERING DEVICE ID Piston TXV ORIFICE OD (in.) (mm) 0.057 1.45 0.063 1.60 0.073 1.85 0.076 1.93 0.080 2.03 N/A OUTDOOR COIL ROWS...FINS/in. FACE AREA (sq. ft) 1...20 9.1 1...20 9.1 2...20 9.1 2...20 10.2 2...20 13.0 2...20 15.5 OUTDOOR FAN NOMINAL AIRFLOW (CFM) DIAMETER (in.) DIAMETER (mm) MOTOR HP (RPM) 2400 20 508 1/8 (825) 2400 20 508 1/8 (825) 2700 20 508 1/4 (1100) 2700 20 508 1/4 (1100) 2700 20 508 1/4 (1100) 3000 20 508 1/3 (1110) INDOOR COIL ROWS...FINS/in. FACE AREA (sq. ft) 2...12 4.3 3...12 4.3 3...12 4.3 3...12 4.9 3...15 4.9 3...15 6.1 INDOOR BLOWER NOMINAL COOLING AIRFLOW (CFM) NOMINAL SIZE W x D (in.) (mm) MOTOR (HP) 800 8 x 11 254 x 203 1/3 1000 8 x 11 254 x 203 1/3 1200 9 x 12 279 x 229 1/2 1400 9 x 12 279 x 229 1/2 1600 11 x 12 279 x 229 3/4 1850 11 x 12 267 x 305 1 HIGH­PRESSURE SWITCH (psig) CUTOUT RESET (AUTO) 650 +/­ 15 420 +/­ 25 RETURN­AIR FILTERS THROWAWAY (in.) (mm) 20x20x1 508x508x25 20x24x1 508x610x25 24x30x1 610x762x25 24x36x1 610x914x25 *Required filter sizes shown are based on the AHRI (Air Conditioning, Heating and Refrigeration Institute) rated airflow at a velocity of 300 ft/min for throwaway type or 450 ft/min for high capacity type. Recommended filters are 1−in. (25.4 mm) thick. Multiplication Factors HEATER kW RATING VOLTAGE DISTRIBUTION MULTIPLICATION FACTOR 240 200 .69 208 .75 230 .92 240 1.00 Example: 15.0 kW (at 240v) heater on 208v = 15.0 (.75 mult factor) = 11.25 capacity at 208v 4 426 41 1707 05Specifications subject to change without notice. DIMENSIONAL DRAWINGS — 24−36 A180299 426 41 1707 05 5Specifications subject to change without notice. DIMENSIONAL DRAWINGS — 42−60 A180309 6 426 41 1707 05Specifications subject to change without notice. SELECTION PROCEDURE A. DETERMINE COOLING AND HEATING REQUIREMENTS AT DESIGN CONDITIONS. Given: Required Cooling Capacity (TC) 34,000 Btuh....... Sensible Heat Capacity (SHC) 25,000 Btuh........ Required Heating Capacity 15,000 Btuh........... Outdoor Entering−Air Temperature 95°F (35°C)..... Indoor Entering−Air Temperature 80°F edb (26.7°C); 67°F (19.4°C) ewb Indoor−Air Quantity 1200 CFM.................... External Static Pressure 0.20 IN. W.C.............. Electrical Characteristics (V−Ph−Hz) 230−1−60..... B. SELECT UNIT BASED ON REQUIRED COOLING CAPACITY (3−TON EXAMPLE) Enter Cooling Capacities table at condenser entering temperature of 95°F (35°C), indoor air entering at 1200 CFM and 67°F (19.4°C) ewb. The 36 unit provides a total cooling capacity of 34,500 Btuh and a sensible heat capacity of 26,040 Btuh. For indoor−air temperature other than 80°F (26.7°C) edb, calculate sensible heat capacity correction, as required, using the formula found following the Cooling Capacities tables. NOTE: Unit ratings are net capacities. C. SELECT ELECTRIC HEAT. The required heating capacity is 15,000 Btuh (given). Determine the electric heat capacity in kW. 15,000 Btuh 3414 Btuh/kW = 3.8 kW of heat required Enter the Accessory Electric Heater table on page 4 for 208/230, single−phase, 036 unit. The 5−kW heater at 240v most closely satisfies the heating required. To calculate kW at 230 V, multiply the heater kW by multiplication factor 0.92 found in the Multiplication Factors table on page 4. 5 kW x 0.92 = 4.6 kW 4.6 kW x 3414 Btuh/kW = 15,704 Btuh D. DETERMINE FAN SPEED AND POWER REQUIREMENTS AT DESIGN CONDITIONS. Before entering the air delivery tables, calculate the total static pressure required. From the given, Filter Pressure Drop table, and the Accessory Electric Heat Pressure Drop table find: External static pressure 0.20 IN. W.C. Filter 0.10 IN. W.C. Electric Heat 0.04 IN. W.C. Total static pressure 0.34 IN. W.C. Enter the table for Dry Coil Air Delivery — Horizontal Discharge. At 0.4 IN. W.C. external static pressure and medium speed, the motor delivers 1236 CFM. 7426 41 1707 05Specifications subject to change without notice.PERFORMANCE DATA Cooling Capacities 24 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (24)85 (29)95 (35)105 (41)115 (46) CFM EWB F (C) Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KWTotalSensTotalSensTotalSensTotalSensTotalSens 700 57 (13.9)21.11 21.11 1.61 20.33 20.33 1.80 19.44 19.44 2.00 18.39 18.39 2.22 16.99 16.99 2.45 62 (16.7)21.97 20.56 1.61 21.01 20.12 1.80 19.92 19.58 2.01 18.62 18.89 2.23 16.85 16.85 2.45 63 (17.2)*22.40 16.82 1.61 21.41 16.39 1.80 20.31 15.89 2.01 18.95 15.25 2.23 17.10 14.40 2.45 67 (19.4)24.12 17.41 1.62 23.11 16.98 1.81 21.98 16.51 2.03 20.69 15.99 2.27 19.08 15.31 2.53 71 (21.7)25.87 14.83 1.64 24.84 14.43 1.83 23.69 13.97 2.04 22.40 13.46 2.29 20.92 12.89 2.56 800 57 (13.9)22.00 22.00 1.62 21.20 21.20 1.81 20.32 20.32 2.03 19.24 19.24 2.26 17.84 17.84 2.49 62 (16.7)22.51 21.92 1.63 21.54 21.49 1.82 20.47 20.95 2.03 19.27 19.27 2.26 17.87 17.87 2.49 63 (17.2)*22.88 17.76 1.63 21.86 17.34 1.82 20.73 16.85 2.03 19.36 16.24 2.26 17.53 15.41 2.48 67 (19.4)24.61 18.36 1.64 23.57 17.97 1.83 22.40 17.50 2.04 21.09 16.99 2.29 19.53 16.40 2.56 71 (21.7)26.33 15.46 1.65 25.29 15.08 1.84 24.10 14.63 2.06 22.78 14.13 2.31 21.28 13.57 2.58 900 57 (13.9)22.74 22.74 1.64 21.92 21.92 1.83 21.01 21.01 2.05 19.95 19.95 2.29 18.58 18.58 2.54 62 (16.7)22.99 23.16 1.64 22.01 22.69 1.83 21.02 21.02 2.05 19.97 19.97 2.29 18.61 18.61 2.54 63 (17.2)*23.26 18.63 1.64 22.21 18.21 1.83 21.06 17.74 2.05 19.70 17.18 2.29 17.88 16.36 2.51 67 (19.4)24.98 19.24 1.65 23.91 18.86 1.84 22.71 18.43 2.06 21.39 17.90 2.30 19.82 17.35 2.58 71 (21.7)26.69 16.04 1.67 25.63 15.67 1.86 24.42 15.24 2.08 23.06 14.74 2.32 21.55 14.19 2.60 30 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (24)85 (29)95 (35)105 (41)115 (46) CFM EWB F (C) Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KWTotalSensTotalSensTotalSensTotalSensTotalSens 875 57 (13.9)27.60 27.60 1.98 26.50 26.50 2.19 25.24 25.24 2.42 23.71 23.71 2.67 21.76 21.76 2.93 62 (16.7)28.34 26.09 1.98 26.97 25.48 2.19 25.44 24.73 2.43 23.76 23.76 2.67 21.80 21.80 2.93 63 (17.2)*28.82 21.14 1.99 27.42 20.55 2.20 25.85 19.89 2.44 23.90 19.03 2.67 21.30 17.92 2.91 67 (19.4)31.10 21.94 2.00 29.67 21.41 2.22 28.08 20.78 2.46 26.22 20.05 2.73 23.80 19.09 3.00 71 (21.7)33.50 18.60 2.03 32.03 18.06 2.24 30.40 17.48 2.48 28.60 16.81 2.77 26.45 16.02 3.08 1000 57 (13.9)28.80 28.80 2.01 27.65 27.65 2.22 26.38 26.38 2.47 24.84 24.84 2.73 22.85 22.85 2.99 62 (16.7)29.07 27.98 2.01 27.73 27.50 2.22 26.42 26.42 2.47 24.88 24.88 2.73 22.89 22.89 2.99 63 (17.2)*29.43 22.47 2.01 27.98 21.90 2.22 26.39 21.24 2.47 24.44 20.41 2.72 21.82 19.29 2.95 67 (19.4)31.71 23.32 2.03 30.24 22.82 2.24 28.60 22.20 2.49 26.75 21.50 2.76 24.35 20.58 3.05 71 (21.7)34.11 19.53 2.05 32.60 19.03 2.27 30.92 18.43 2.51 29.06 17.77 2.80 26.90 17.01 3.11 1125 57 (13.9)29.76 29.76 2.04 28.59 28.59 2.25 27.28 27.28 2.50 25.75 25.75 2.77 23.78 23.78 3.05 62 (16.7)29.80 29.80 2.04 28.63 28.63 2.25 27.32 27.32 2.50 25.78 25.78 2.78 23.82 23.81 3.05 63 (17.2)*29.89 23.71 2.04 28.42 23.16 2.25 26.81 22.52 2.49 24.85 21.71 2.75 22.25 20.59 2.99 67 (19.4)32.18 24.61 2.06 30.66 24.12 2.27 29.01 23.55 2.51 27.14 22.85 2.79 24.81 21.99 3.09 71 (21.7)34.59 20.40 2.08 33.04 19.89 2.29 31.31 19.33 2.54 29.40 18.68 2.82 27.22 17.94 3.14 See Legend and Notes on page 10. 426 41 1707 058Specifications subject to change without notice.COOLING CAPACITIES (CONT) 36 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (24)85 (29)95 (35)105 (41)115 (46) CFM EWB F (C) Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KWTotalSensTotalSensTotalSensTotalSensTotalSens 57 (13.9)33.44 33.44 2.35 31.96 31.96 2.59 29.97 29.97 2.84 27.67 27.67 3.12 25.22 25.22 3.45 62 (16.7)34.22 31.29 2.36 32.42 30.45 2.60 30.12 29.15 2.84 27.72 27.72 3.12 25.24 25.24 3.45 63 (17.2)*34.84 25.34 2.36 32.94 24.51 2.60 30.42 23.42 2.85 27.34 22.11 3.11 24.16 20.79 3.42 1050 67 (19.4)37.73 26.43 2.41 35.79 25.64 2.66 33.57 24.74 2.93 30.40 23.49 3.18 27.11 22.21 3.49 71 (21.7)40.85 22.45 2.44 38.88 21.72 2.71 36.70 20.91 3.00 33.78 19.82 3.27 30.28 18.55 3.57 57 (13.9)34.88 34.88 2.40 33.34 33.34 2.65 31.45 31.45 2.91 28.98 28.98 3.18 26.41 26.41 3.51 62 (16.7)35.12 33.55 2.40 33.20 33.20 2.64 31.51 31.51 2.91 29.02 29.02 3.18 26.46 26.46 3.51 1200 63 (17.2)*35.55 26.89 2.40 33.61 26.06 2.65 31.13 25.01 2.90 28.00 23.71 3.16 24.74 22.34 3.47 67 (19.4)38.47 28.10 2.45 36.47 27.30 2.70 34.20 26.40 2.97 31.08 25.20 3.23 27.68 23.88 3.54 71 (21.7)41.59 23.57 2.48 39.58 22.87 2.75 37.38 22.07 3.04 34.48 21.01 3.33 30.86 19.72 3.62 57 (13.9)36.08 36.08 2.45 34.48 34.48 2.70 32.64 32.64 2.97 30.06 30.06 3.24 27.39 27.39 3.56 62 (16.7)36.12 36.12 2.45 34.54 34.54 2.70 32.69 32.69 2.97 30.11 30.11 3.24 27.44 27.44 3.56 1350 63 (17.2)*36.10 28.35 2.44 34.12 27.53 2.69 31.76 26.55 2.95 28.50 25.18 3.20 25.21 23.76 3.51 67 (19.4)39.04 29.64 2.48 36.98 28.88 2.74 34.70 27.99 3.02 31.57 26.78 3.27 28.16 25.44 3.58 71 (21.7)42.15 24.61 2.51 40.11 23.92 2.78 37.87 23.13 3.08 35.02 22.12 3.38 31.28 20.82 3.67 See Legend and Notes on page 10. 42 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (24)85 (29)95 (35)105 (41)115 (46) CFM EWB F (C) Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KWTotalSensTotalSensTotalSensTotalSensTotalSens 1225 57 (14)41.68 41.68 2.75 38.94 38.94 3.11 35.98 35.98 3.49 32.25 32.25 3.87 28.66 28.66 4.32 62 (17)42.95 38.93 2.75 39.78 36.79 3.12 36.43 34.57 3.50 32.28 32.28 3.87 28.71 28.71 4.32 63 (17)43.70 31.61 2.75 40.44 29.72 3.12 36.99 27.79 3.51 32.43 25.38 3.87 27.98 23.06 4.30 67 (19)47.16 32.78 2.77 43.74 30.91 3.13 40.27 29.04 3.52 36.10 26.97 3.96 31.37 24.61 4.39 71 (22)51.59 26.51 2.78 47.98 24.89 3.15 44.33 23.26 3.55 40.57 21.60 3.99 36.10 19.78 4.49 1400 57 (14)43.43 43.43 2.79 40.56 40.56 3.15 37.56 37.56 3.55 33.84 33.84 3.94 30.06 30.06 4.39 62 (17)44.02 41.66 2.79 40.84 39.39 3.16 37.60 37.60 3.55 33.90 33.90 3.94 30.11 30.11 4.40 63 (17)44.60 33.50 2.79 41.26 31.57 3.16 37.77 29.61 3.55 33.24 27.21 3.92 28.66 24.78 4.36 67 (19)48.06 34.74 2.81 44.57 32.83 3.17 41.00 30.90 3.56 37.08 28.93 4.01 32.09 26.48 4.45 71 (22)52.46 27.65 2.82 48.78 26.00 3.19 45.03 24.35 3.59 41.21 22.67 4.03 36.86 20.91 4.53 1575 57 (14)44.86 44.86 2.83 41.89 41.89 3.19 38.82 38.82 3.59 35.20 35.20 4.02 31.25 31.25 4.47 62 (17)45.00 44.04 2.83 41.94 41.94 3.20 38.88 38.88 3.59 35.25 35.25 4.02 31.28 31.28 4.47 63 (17)45.28 35.25 2.83 41.88 33.29 3.20 38.36 31.31 3.59 33.90 28.93 3.98 29.21 26.39 4.41 67 (19)48.74 36.57 2.84 45.17 34.62 3.21 41.56 32.62 3.60 37.71 30.65 4.05 32.66 28.22 4.50 71 (22)53.13 28.71 2.86 49.38 27.04 3.23 45.55 25.35 3.63 41.66 23.65 4.07 37.49 21.93 4.58 See Legend and Notes on page 10. 9426 41 1707 05Specifications subject to change without notice.COOLING CAPACITIES (CONT) 48 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (24)85 (29)95 (35)105 (41)115 (46) CFM EWB F (C) Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KWTotalSensTotalSensTotalSensTotalSensTotalSens 1400 57 (14)46.69 46.69 3.18 43.96 43.96 3.55 41.20 41.20 3.97 38.15 38.15 4.45 34.26 34.26 4.96 62 (17)48.24 40.86 3.19 45.07 40.07 3.56 41.86 39.18 3.99 38.39 38.02 4.46 34.32 34.32 4.97 63 (17)49.13 33.18 3.19 45.86 32.38 3.57 42.55 31.50 4.00 38.89 30.43 4.47 34.04 28.78 4.95 67 (19)53.03 34.45 3.21 49.63 33.69 3.59 46.16 32.87 4.03 42.51 31.94 4.54 38.08 30.67 5.10 71 (22)58.07 27.87 3.25 54.53 27.15 3.63 50.89 26.37 4.07 47.09 25.48 4.58 43.08 24.48 5.17 1600 57 (14)48.69 48.69 3.24 45.86 45.86 3.62 42.97 42.97 4.06 39.87 39.87 4.56 35.98 35.98 5.08 62 (17)49.45 43.78 3.24 46.24 42.96 3.62 43.08 42.83 4.06 39.93 39.93 4.56 36.04 36.04 5.08 63 (17)50.14 35.19 3.25 46.79 34.40 3.62 43.38 33.54 4.06 39.71 32.52 4.55 34.85 30.91 5.04 67 (19)54.04 36.51 3.27 50.57 35.78 3.65 47.00 35.00 4.09 43.31 34.10 4.60 39.07 33.00 5.18 71 (22)59.08 29.08 3.31 55.45 28.38 3.69 51.71 27.61 4.13 47.83 26.75 4.64 43.74 25.74 5.24 1800 57 (14)50.32 50.32 3.30 47.39 47.39 3.68 44.38 44.38 4.12 41.24 41.24 4.63 37.45 37.45 5.19 62 (17)50.52 46.35 3.30 47.46 47.46 3.68 44.44 44.44 4.12 41.29 41.29 4.63 37.50 37.50 5.19 63 (17)50.90 37.05 3.30 47.50 36.30 3.68 44.02 35.46 4.12 40.35 34.49 4.62 35.52 32.90 5.12 67 (19)54.81 38.44 3.33 51.26 37.75 3.70 47.64 36.98 4.14 43.89 36.11 4.65 39.74 35.07 5.24 71 (22)59.83 30.17 3.37 56.13 29.51 3.75 52.32 28.76 4.19 48.35 27.90 4.70 44.21 26.91 5.30 See Legend and Notes on page 10. 60 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (24)85 (29)95 (35)105 (41)115 (46) CFM EWB F (C) Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KW Capacity MBtuh Total Sys KWTotalSensTotalSensTotalSensTotalSensTotalSens 1500 57 (14)52.95 52.95 3.74 50.23 50.23 4.14 47.43 47.43 4.61 44.47 44.47 5.15 41.30 41.30 5.78 62 (17)55.05 45.97 3.75 51.84 44.39 4.16 48.53 42.78 4.62 45.08 41.06 5.16 41.48 39.18 5.78 63 (17)56.01 37.50 3.76 52.73 36.05 4.17 49.33 34.54 4.63 45.76 32.97 5.17 42.01 31.33 5.79 67 (19)59.99 38.77 3.80 56.43 37.29 4.20 52.75 35.77 4.67 48.90 34.18 5.21 44.88 32.53 5.83 71 (22)65.50 31.45 3.84 61.58 30.06 4.25 57.53 28.62 4.72 53.33 27.13 5.26 48.93 25.58 5.89 1700 57 (14)54.98 54.98 3.81 52.11 52.11 4.21 49.12 49.12 4.68 45.98 45.98 5.23 42.63 42.63 5.85 62 (17)56.20 49.14 3.82 52.89 47.48 4.22 49.49 45.72 4.69 46.04 46.04 5.23 42.69 42.69 5.86 63 (17)57.05 39.66 3.83 53.64 38.16 4.23 50.11 36.61 4.70 46.43 34.99 5.23 42.56 33.29 5.85 67 (19)61.05 41.09 3.86 57.35 39.56 4.26 53.53 37.99 4.73 49.57 36.36 5.27 45.42 34.64 5.89 71 (22)66.61 32.86 3.91 62.53 31.43 4.31 58.37 29.96 4.78 54.02 28.44 5.33 49.49 26.85 5.95 1850 57 (14)56.30 56.30 3.86 53.30 53.30 4.27 50.20 50.20 4.74 46.93 46.93 5.28 43.46 43.46 5.91 62 (17)56.95 51.37 3.87 53.60 49.58 4.27 50.27 50.27 4.74 46.99 46.99 5.28 43.52 43.52 5.91 63 (17)57.68 41.23 3.87 54.17 39.68 4.27 50.58 38.10 4.74 46.82 36.45 5.28 42.89 34.72 5.90 67 (19)61.67 42.77 3.90 57.88 41.20 4.31 54.00 39.60 4.78 49.95 37.93 5.32 45.73 36.18 5.94 71 (22)67.25 33.87 3.95 63.10 32.42 4.36 58.84 30.93 4.83 54.41 29.38 5.37 49.81 27.77 6.00 See Legend and Notes on page 10. 426 41 1707 05 10Specifications subject to change without notice. * At 75°F entering dry bulb - Tennessee Valley Authority (TVA) rating conditions; all others at 80°F dry bulb. LEGEND BF — Bypass Factor Ewb — Entering Wet-Bulb kW — Total Unit Power Input SHC — Sensible Heat Capacity (1000 Btuh) TC — Total Capacity (1000 Btuh) (net) NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: Sensible capacity (Btuh) 1.10 x cfm tldb = tedb − Wet −bulb temperature corresponding to enthalpy air leaving evaporator coil (hlwb) tlwb = total capacity (Btuh) 4.5 x cfm hlwb = hewb − Where: hewb = Enthalpy of air entering evaporator coil3. The SHC is based on 80° F (26.7°C) edb temperature of air entering indoor coil. Below 80° F (26.7°C) edb, subtract (corr factor x cfm) from SHC. Above 80° F (26.7°C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 - BF) x (edb - 80). Filter Pressure Drop (IN. W.C.) FILTER SIZE in. (mm) CFM 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 20X20X1 (508X508X25)0.05 0.07 0.08 0.10 0.12 0.13 0.14 0.15 —————————— 20X24X1 (508X610x25)———0.08 0.09 0.10 0.11 0.13 0.14 0.15 0.16 ——————— 24X30X1 (610X762x25)———0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.10 ——————— 24X36X1 (610X914X25)———————0.06 0.07 0.07 0.08 0.09 0.09 0.10 0.11 0.12 0.13 0.14 Accessory Electric Heat Pressure Drop (IN. W.C.) HEATER kW CFM 800 1000 1200 1400 1600 1800 2000 2200 5−20 0.033 0.037 0.042 0.047 0.052 0.060 0.067 0.075 Wet Coil Delivery*— (Deduct 10% for 208−Volt Operation) UNIT SIZE SPEED TAP AIR DELIVERY2 EXTERNAL STATIC PRESSURE (in. W.C.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 24 1 SCFM 965 818 777 731 670 617 563 489 451 391 2 SCFM 1003 921 890 850 809 756 700 659 597 539 3 SCFM 1103 1068 1034 996 962 930 892 821 791 742 30 1 SCFM 1052 1018 984 943 914 879 833 795 732 678 2 SCFM 1141 1107 1069 1036 1006 974 932 899 856 784 3 SCFM 1246 1213 1181 1144 1108 1078 1043 1015 973 931 36 1 SCFM 1281 1225 1178 1142 1098 1053 1008 935 878 840 2 SCFM 1359 1321 1278 1236 1201 1160 1109 1068 992 941 3 SCFM 1476 1441 1403 1366 1323 1289 1245 1201 1159 1117 42 1 SCFM 1453 1408 1373 1337 1295 1255 1215 1177 1134 1068 2 SCFM 1544 1507 1475 1436 1397 1359 1326 1290 1246 1201 3 SCFM 1614 1575 1542 1509 1467 1430 1395 1358 1323 1267 48 1 SCFM 1657 1625 1590 1554 1517 1486 1448 1417 1381 1340 2 SCFM 1707 1673 1644 1614 1586 1549 1515 1479 1449 1407 3 SCFM 1931 1900 1870 1840 1809 1778 1749 1714 1683 1646 60 1 SCFM 1931 1881 1833 1787 1746 1698 1670 1622 1577 1514 2 SCFM 2038 1994 1935 1894 1851 1811 1774 1738 1691 1648 3 SCFM 2144 2113 2052 2001 1974 1928 1898 1860 1824 1773 *Air delivery values are based on operating voltage of 230v, wet coil, without filter or electric heater. Deduct filter and electric heater pressure drops to obtain static pressure available for ducting. NOTES: 1. Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Evaporator coil frosting may occur at airflows below this point. 2. Standard Cubic Feet per Minute. 11 426 41 1707 05Specifications subject to change without notice. TYPICAL CONNECTION WIRING SCHEMATIC—208/230−1−60, 24−60 A14548 426 41 1707 05 12Specifications subject to change without notice. TYPICAL LADDER WIRING SCHEMATIC—208/230−1−60, 24−60 A14549 13 426 41 1707 05Specifications subject to change without notice. TYPICAL FIELD WIRING NOTE: 20kW Heater shown. Smaller heaters have fewer elements and controls A190069 Single−Phase Accessory Electric Heater Wiring 426 41 1707 05 14Specifications subject to change without notice. Electrical Data Model Nominal V­PH­HZ Voltage Range Compressor OFM IFM Nominal kW*Heater FLA MCA MOCP** Min Max RLA LRA FLA FLA 208/240 208 240 208 230 208/230 24 208/230­1­60 197 253 10.3 61.6 0.9 2.8 ­/­­­16.6 16.6 25 3.8/5 18.0 20.8 26.0 29.5 30/30 5.6/7.5 27.0 31.3 37.3 42.6 40/45 7.5/10 36.1 41.7 48.6 55.6 50/60 30 208/230­1­60 197 253 13.5 72.5 0.9 2.8 ­/­­­20.6 20.6 30 3.8/5 18.0 20.8 26.0 29.5 30/30 5.6/7.5 27.0 31.3 37.3 42.6 40/45 7.5/10 36.1 41.7 48.6 55.6 50/60 36 208/230­1­60 197 253 14.1 77 1.5 4.1 ­/­­­23.2 23.2 35 3.8/5 18.0 20.8 27.6 31.1 35/35 5.6/7.5 27.0 31.3 38.9 44.3 40/45 7.5/10 36.1 41.7 50.3 57.3 60/60 11.3/15 54.1 62.5 72.8 83.3 80/90 42 208/230­1­60 197 253 15.9 112.3 1.7 4.1 ­/­­­25.7 25.7 40 3.8/5 18.0 20.8 27.6 31.1 40/40 5.6/7.5 27.0 31.3 38.9 44.3 40/45 7.5/10 36.1 41.7 50.3 57.3 60/60 11.3/15 54.1 62.5 72.8 83.3 80/90 48 208/230­1­60 197 253 19.6 130 1.7 6.0 ­/­­­32.2 32.2 50 3.8/5 18.0 20.8 32.2 33.5 50/50 5.6/7.5 27.0 31.3 41.3 46.6 50/50 7.5/10 36.1 41.7 52.6 59.6 60/60 11.3/15 54.1 62.5 75.1 85.6 80/90 15/20 72.1 83.3 97.6 111.6 100/125 60 208/230­1­60 197 253 23.7 152.5 1.9 7.6 ­/­­­39.1 39.1 60 3.8/5 18.0 20.8 39.1 39.1 60/60 5.6/7.5 27.0 31.3 43.3 48.6 60/60 7.5/10 36.1 41.7 54.6 61.6 60/70 11.3/15 54.1 62.5 77.1 87.6 80/90 15/20 72.1 83.3 99.6 113.6 100/125 ** HACR Type Circuit breaker LEGEND FLA - Full Load Amps LRA - Locked Rotor Amps MCA - Minimum Circuit Amps MOCP - Maximum Overcurrent Protection RLA - Rated Load Amps NOTES: 1. In compliance with NEC (National Electrical Code) requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be Power Supply fuse or circuit breaker. 2. Minimum wire size is based on 60 C copper wire. If other than 60 C wire is used, or if length exceeds wire length in table, determine size from NEC. *Heater capacity (kW) based on heater voltage of 208v & 240v. If power distribution voltage to unit varies from rated heater voltage, heater kW will vary accordingly. OPERATING SEQUENCE Cooling Operation With a call for cooling (Y/G), the contactor is energized which brings on the compressor and outdoor fan. The indoor fan is also energized. When the cooling demand is met, Y and G are de−energized shutting off the contactor. The indoor fan stops after a 60 second delay. Heating Operation With a call for heating (W2), the auxiliary or electric heat energizes along with the indoor blower. In case of staged heating, W3 is energized if the demand is not met. The highest airflow selected is run while the electric heat is in operation. When heating demand is met, W3 and W2 sequentially de−energize shutting off the indoor fan and the electric heater. Continuous Fan With the continuous indoor fan option selected on the thermostat, G is continuously energized keeping the indoor fan running at all times. APPLICATION DATA Condensate trap — A 2−in. (51 mm) condensate trap must be field supplied. 1” (25 mm) MIN. 2” (51 mm) MIN. TRAP OUTLET A08001 Maximum cooling airflow — To minimize the possibility of condensate blow−off from the evaporator, airflow through the units should not exceed 450 CFM/ton. Minimum cooling airflow — The minimum cooling airflow is 350 cfm/ton. Minimum cooling operating outdoor air temperature — All standard units have a minimum ambient operating temperature of 40°F (4.4°C). With accessory low ambient temperature kit, units can operate at temperatures down to 0°F (−17.8°C). Maximum operating outdoor air temperature — Maximum outdoor operating air temperature for cooling is 125°F (51.7°C). 15 426 41 1707 05Specifications subject to change without notice. TYPICAL INSTALLATION TOP COVER INDOOR THERMOSTAT DISCONNECT PER NEC (UNIT AND ELECTRIC HEATER) FROM POWER SOURCE RETURN AIR POWER ENTRY COMPOSITE RUST-PROOF BASEPAN CONDENSATE DRAIN CONNECTION Power Wiring Control Wiring Condenser Airflow Evaporator Airflow LOW VOLTAGE ENTRY A10135 ENGINEERS’ SPECIFICATION GUIDE GENERAL Furnish and install outdoor package, electrically controlled, air conditioner utilizing a reciprocating or scroll compressor for cooling duty. Unit shall discharge supply air horizontally as shown on contract drawings. Nominal unit electrical characteristics shall be ______ v, ______ ph, 60 Hz. The unit shall be capable of satisfactory operation within voltage limits of ______ v to ______ v. Unit power wiring shall enter unit cabinet at a single location. Separate power supply shall not be required for electric heat. COOLING CAPACITY Total cooling capacity of the unit shall be _____ Btuh or greater, and sensible capacity shall be ______ Btuh or greater at conditions of ______ cfm indoor air entering unit at ______F dry bulb, _____ F wet bulb and outdoor entering air of ______F dry bulb. Total design conditions shall be a minimum of ______ Btuh/Watt. The unit shall be capable of cooling operation down to 40 F (4.4 C) as shipped from the factory. CABINET Unit cabinet shall be constructed of phosphated, bonderized, zinc−coated, prepainted steel. Basepan shall be made of a single−piece non−corrosive, composite material. Evaporator−fan compartment interior cabinet surfaces shall be insulated with a minimum 1/2−in. (12.7 mm) thick, flexible fiberglass insulation, coated on the air side with aluminum foil. Cabinet panels shall be easily removable for servicing. Outdoor coil shall be protected by metal louvered panels. COMPRESSOR Compressor shall be fully hermetic type with external vibration isolation. CONDENSER SECTION Condenser fan shall be of the direct−driven propeller type blades, riveted to corrosion−resistant spiders, and shall be dynamically balanced and discharge air vertically upwards. Condenser coils shall have aluminum−plate fins mechanically bonded to copper tubes with all joints brazed. Tube sheet openings shall be belled to prevent tube wear. EVAPORATOR SECTION Fan shall be multi−speed with direct drive motor as shown on the equipment drawings. Fan wheel shall be made from steel, be double−inlet type with forward−curved blades with a corrosion−resistant finish and dynamically balanced. Evaporator coils shall have aluminum−plate fins mechanically bonded to copper tubes with all joints brazed. Tube sheet openings shall be belled to prevent tube wear. MOTORS Compressor motors shall be of the refrigerant cooled type with line break thermal and current overload protection. All fan motors shall have permanently lubricated bearings, and inherent automatic reset thermal overload protection. Condenser fan motor shall be totally enclosed. REFRIGERANT SYSTEM Refrigerant system shall include fixed orifice or TXV metering system. CONTROLS Unit shall be complete with self−contained low voltage control circuit. APPROVALS Unit shall be UL listed as a total package for safety requirements. All wiring shall be in accordance with NEC. Unit shall be rated in accordance with AHRI Standards 210/240. Cabinet insulation shall conform to ASHRAE Standard 62.2 Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. Unit shall have a sloped drain pan that conforms to ASHRAE Standard 62.2. ACCESSORIES Field−installed accessories shall include solid−state compressor short−cycle device, outdoor thermostat, room thermostats, electric heaters with single−point connection, crankcase heater, and low−ambient kit. 426 41 1707 05 16Specifications subject to change without notice. OPTIONS AND ACCESSORIES PART NUMBER ITEM DESCRIPTION FIELD INSTALLED ACCESSORY CPHSTART002A00 Compressor Start Kit Compressor Start Kit assists compressor start-up by providing additional starting torque on sing phase units only.X CPCRKHTR008A00 Crankcase Heater Crankcase Heater provides anti-floodback protection for low-load cooling applications. 24 - 36 CPCRKHTR004A00 42 - 60 CPLOWAMB001A00 Low Ambient Kit Low Ambient Kit (Motormaster II Control) allows the use of mechanical cooling down to outdoor temperatures as low as 0°F (-18°C) when properly installed.X NRTIMEGD001A00 Time Guard II Automatically prevents the compressor from restarting for at least 4 minutes and 45 seconds after shutdown of the compressor. Not required when a corporate programmable thermostat is applied. X Accessory Electric Heaters CATALOG ORDERING NO. NOMINAL CAPACITY (kW) USED WITH SIZES CIRCUIT BREAKER (Yes/No) STAGES 24 30 36 42 48 60 ELECTRIC HEATERS (208/230-SINGLE PHASE-60Hz) CPHEATER125A0*3.8 / 5.0 No 1 √√√√√√ CPHEATER126A0*3.8 / 5.0 Yes 1 √√√√√√ CPHEATER127A0*5.6 / 7.5 No 2 √√√√√√ CPHEATER128A0*5.6 / 7.5 Yes 2 √√√√√√ CPHEATER129A0*7.5 / 10.0 No 2 √√√√√ CPHEATER130A0*7.5 / 10.0 Yes 2 √√√√√√ CPHEATER131A0*11.3 / 15.0 Yes 2 √√√√ CPHEATER132A0*15.0 / 20.0 Yes 2 √√ √ =Approved combination Copyright 2019 International Comfort ProductsLewisburg, Tennessee 37091 USAwww.GoComfortmaker.com