t FL# FL10497-RS
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Mule-Hide Products Co.,Inc.
Address/Phone/Email 1195 Prince Hall Dr
Beloit,WI53511-5481
(608)365-3111 Ext809
Iindareith@trinityerd.com
Authorized Signature Timothy McFarland
Iindareith@trinityerd.com
Technical Representative Tim McFarland
Address/Phone/Email 1195 Prince Hall Dr
Suite A
Beloit,WI 535115481
(608)365-3111
tim.mcfarland@mulehide.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/28/2017
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10497 R5 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D6163 2000
ASTM D6164 2005
ASTM D6222 2008
FM 4470 1992
FM 4474 2004
Equivalence o f Product Standards
Certified By
• i
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/16/2015
Date Validated 12/16/2015
Date Pending FBC Approval 12/17/2015
Date Approved 02/10/2016
Summary of Products
FL# Model,Number or Name Description
10497.1 Mule-Hide SBS and APP Modified Self-adhering modified bitumen roof systems
Bitumen Roof Systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10497 R5 II 201S 12 FINAL Al ER MULE-HIDE FL10497-
Approved for use outside HVHZ:Yes R5.Ddf
Impact Resistant:N/A Verified By: Robert Nleminen PE-59166
Design Pressure:+N/A/-480 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this application relates to Evaluation Reports
one particular assembly over concrete deck. Refer to the ER FL10497 R5 AE 2015 12 FINAL ER MULE-HIDE FL10497-
Appendix for other systems and deck types. 2.) Refer to ER, RS.Ddf
Section 5 for other Limits of Use. Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick ere.
Product Approval Accepts:
`," z; M .
Credit Card
Safe
\\,I TRINITY I ERD
APPENDIX 1'ATTACIiM1AENT REQl11REMENTs FOR WINBUPUFT RESISTANCE 'J
Table. Deck Application Type Description Page
1A Wood New or.Reroof(Tear-dff) A-1 Bonded Insulation;Bonded:Abof Cover 3..
1B-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4'
18-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation Bonded Roof Cover 5
iC - Wood- _Ne---w;Reroof(Tear-Off)-or Recover C Mech.Attached Insulation,Bonded Roof Cover 6
1D Wood New,Reroof(Tear.-Off)or Recover D. Prelim.Attached Insulation,Mech,Attached Base.Sheet,Bonded Roof Cover 7
1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,.Mech.Attached Base Sheet(nails),Bonded Roof Cover B
1Pr2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 9
1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9
2A Steel or Conc: New;Reroof(TearvOff)'or Recover C Mech.Attached Insulation;Bonded Roof Cover 10
28 Steel or Conc. New,Reroof(Tear-Off)or Recover D: Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 11
3A-1 Concrete New or Reroof'(TearOff) A-1 Bonded Insulation;Bonded Roof Cover 12-14
3A-2 Concrete New or Reroof(Tear-OfQ A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover Is
3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover SS
4A' LWIC New or'Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 16-17
4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet;Bonded Insulation,Bonded Roof Cover 17
4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet;Bonded Roof Cover 1&19
SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Banded.Roof.Cover 20k
58 CWF New,Reroof(Tear-Off)or Recover A-2 Mech.AttachedAnchor Sheet,Bonded Insulation',Bonded Roof Cover 20
SC CWF New or Reroof(Tear-Off) E Non;Insulated;Mech.Attached Base Sheet,Bonded Roof Cover 20
6A Gypsum. Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 21
68 Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Banded Roof Cover 22
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 22-23
The'followinR notes apply to the systems autllned herein: •
1. The roof system evaluation herein pertains to-above-deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the,A141...Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
+—Wood: Minimum 0.75-inch penetration.
➢Steel: Minimum 0.75-inch penetration and engage:the top flute of the steer deck,
Concrete: Minimum 14nch embedment into pilot hole in accordance with fastenermanufacturers published installation instructions;
3. Unless otherwise noted,insulation may be any one layer or combination of po►yisocyanurate, polystyrene,wood fiberboard,,perlite,gypsum-based roof boardor mineral-wool roof board that meets the CA
requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
4. Minimum.200 psi,.minimum 2-inch thick,lightweight insulating concrete may be substituted for rigid insulation board for System'type D'(mechanically attached base sheet,bonded roof cover),whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck: The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members-shali bein'accordance Wtth FBC requireMents.to the'satisfaction of the AW.'Load'resistance of the roof deck shall be documented through proper'codified and/or FBC Approval documentation.
Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report 1\410000.03.08-RS fbe-FL10497-R5
Certificate of Authorization N9503 Revision5:'12/14/2019
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of23
TRiNITY I ERD
S. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instrudtions.
Y Hot asphalt: Full coverage at 25-30)bs/square.
i Dow Insta-Stik Roofing Adhesive.(D-i5): Continuous 0.75 to 1-inch wide ribbons;.12-incho:c.
i Millennium One Step Foamable Adhesive(M-OSFA): Continuous US to 0.5-Inch wide ribbons,I2-inch o.c.
Y OMG'OlyBond 500(OB500): Continuous'0.75 to 1-inch wide ribbons,l2-inch o.c:(PaceCart or Spot5hot). Note: 01y8ond Green may be used where OlyBond s00 is referenced.
9.OlyBond Classic.(08 Classic): Full coverage at 1 gal/square.
y-31VI CR-20: -- _ Continuous 2.5-3.54nch wide ribbons;124hch o.c. -
Note: When multiple layers(s)of insulation and/arcoverboard are installed in ribbon-applied adhesive;boord)ointsshall be staggered.
Y Note: The maximum edge distance from the adhesive ribbon to the edge of the,insulotion board shall bernofless than one-half the specified tibbonsspacing. !�
6. Unless otherwise noted,all insulations are fiat stock or taper board of the'ininimum thickness noted..Tapered polyisocyanurate'at.the following thickness limitations may be substituted With thefollowing Maximum
Design Pressure(MDP)limitations;:In no case shall these values be used to'Increase'the MDP listings in the tables;rather,if MOP.listing below meets or exceeds that listed for a particular system in the tables,then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
i Millennium One Step Foamable Adhesive(M-OSFA) MDP, -157.5 psf (Min.0.5ynch thick)
:%OMG OlyBond 500(OBS00):. MOP -45.0 psf: (Min:0.5-inch thick Multi-'Max FA-3).
Y OMG OlyBond 500(OB500): -MOP- -187:5 psf (Min.0.5-inch thick 1SO.95+CAL)
OMG OlyBond 500(06500): MDP -315.0 psf (Min:0.5-inch thick ENRGY 3)
i OMG OlyBond 500(OB500): MDP -497.5 psf (Min:0.54nch thick ACFoam II,Poly 150 2)
i 3M CR-20: MDP -1175 psf (Min.1.0-inch thick)
7. Bonded polyisocyanurate.insu►ation boards:shall be maximum 4 x 4'ft.
8. For mechanically attached components or partially bonded insulation;the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone-2/3 enhancements.
9: For fully bonded assemblies,the maximum'design pressure for the selected assembly shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16,and no rational analysis Is permitted.
10. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TA5105 or ANSI/SPRI FX-1.
11. Forexisting:substrates in'a bonded recoverinstallation,the existing roof system snail be examined for compatibility and bond performance with theselected adhesive;and the•existft roof system shall:be capable of
resisting project design pressures on its own merit.to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPOS 1-52,ANSI/SPRI IA-1 or TAS 124.
12. for Recover Applications using System Type D,the insulation is optional;however;the existing roof system shall be-suitable fora recover application:
13. LWIC shall be..cast in accordance with FBC Section 1917 to the.satisfaction of;the Authority Having Jurisdiction.For systems Where specific LWIC is referenced,refer•to current LWIC Product Approval for specific deck
construction and limitations. For systems where specific LWIC is not referenced,the.minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,
reference Is*made to FBC'Sectian 1917.4.1,Point 1.
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report M10000.03.08-RS for FL10497-R5
Certificate of Authorization#9503 ' Revision 5:12/1412015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Paget of23
TRINITY ERD
TABLE IF-1-WOOD DECKS—NEW CONSTRUCTION an REROOF.{TEAR-OFF}.
SYSTEMTYPEE.NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NAILS),BONDED ROOF COVER
Base Sheet Roof Cover SeeTable1 MDP(psf).
System Deck(see ( )
No, Note 1) Base, Fasten Attach Base Ply. Cap
To1i6R AFpwp Bn59 %Y;..
—Min.15/32— 9-Inch o.c.at-2-Inch tap and18-Inch o.c.intwo(2),.
W-19 inch plywood Nall Base 51mplex MAXX Cap. equally spaced,staggered center rows (Optional)'APPTA APP--TA. 45.0x
W-20 Min.15/32• Nail Base Simplex MAXX Cap 9-inch ox.at 2-inch lap and 12-inch o.c.in two(2), (Optional)APP-TA APPTA -52.5.
Inch plywood` equally spaced,staggered center rows
W-21 Min,15/32 APPTorch Base,Nail Sale Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c..at3•Inch lap and 6-tnch.o.c.in four(4), (Optional)APp TA APP=TA'. 52.5
inch plywood 11 gouge x min.1.25-inch long annular grooved shank) equally spaced,staggered center rows
Nall'Base,PolyglassG2 Base;
Min.19/32- CertainTeed GlaSbaw,Firestone `32 go :1=518•inch.diameteetincaps withal ga.annular 8-inch o:a in'4-inch lap and 84nch.o:c.In three(3),
W-221.
lnch'plywood MB Base,)M Perma-Ply28,Tamko Ang.shank.nails equally spaced;staggered centerrows (Optional)APP TA. APP-TA -60;0
Glass Base or GAFGLAS P75
Min,15/32- 32 go.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.in 4-inch lap and 8-Inch o.c.in four(4),
W-23 inch plywood Polyglass GZ Base,Nail Base: ring shank nails. equally spaced,staggered center rows (Optional)APP-TA APP TA 67S
W-24 Min.15/32- Polyglass G2 Base,Nail Base, Simplex MAXX Cap 10-Inch o.c.In 4-Inch lap and 10-Inch o.c.In three (Optional)APP TA' APP-TA -75.0
inch plywood. (3),equally spaced;staggered center rows
W 25 Min.15/32- Pol lass 9-inch o.c.in 4-inch lap and 9-inch o.c.in four(4),
Inch plywood y8 G2 Base,Nail Base Simplex P MAXX Cap equally spaced,staggered center..rows (Optional}APP-TA APRTA 90.0
W-26 Min.15/32- Nail Base Simplex MAXX Cap 6-inch o.c.at 2-inch lap and 6-Inch o.c.in two(2), (Optional)APP=TA APP TA -96:0
Inch plywood- equally spaced,staggered centerrows
Min.15/32- Elastobase Simplex MAXX Ca 6-inch o.c.at 2-Inch lap and 6-inch o.c,in three
W Z7 (3};
Inch plywood p equally spaced,staggered centerrows (Optional)APP-TA APP.-TA d-52.5
W 28 Min.19/32- Elastobaseor Elastabase Poly. 32 go,1-5/8-inch diametertin caps with 11 ga.annular 6-inch o.c-in 4-inch lap and 6-inch o.c.In four(4), (Optional)APP-TA APP-TA
Inch plywood ring shank nails equally spaced staggered center rows
W-Z9 Min.15/32- Nail Original Simplex Cap Nails(1-inch metal head diameter;: 6-inch o.c.at 3-inch Tap and 6-inch o.c:in four, (Optional)SOS-SA SOS-5A,APPinch plywood 12 gaugexmin.1.25•Inch long annulargrooved shank), equally spaced,staggeredcenter rows SAAPP-TAMin.19/32- 32 ga.,1-5/8-Inch diameter tin caps with 11 ga:annular S=inch o.c.in 4-inch lap and S-Inch a.c.in.three, SBS-SA,APP-
W-30 Inch I Nall Base (Optional)SBS-Sa
plywood ring shank nails equally spaced,staggered'centerrows SA,APP-TA
W-31 Min.19/32- Nail Base 32 ga.,.1.5/8-Inch*diameter tin caps.with it go.annular 4-inch o.c.in 4-Inch lap and-4-inch o.c.In four, (Optional)SBS-SA SBS-SA,APP- 97 5
inch plywood ring shank nalls. equally spaced,staggered center rows SA,APP+TA.
32 ga.,1-5/8•inch diameter tin caps with 11 go.annular
Min.19/3& 6-inch o.c:1n 44nch tap and 64nch o.c.in SBS-SA;APP-
W-32 Inch plywood Nall Base ring shank nails;Note:Tin caps are to be primed with equally four.,spaced,staggered center rows (Optional)SBS-SA SA,APP-TA -112.5
Mule-Hide 121 or ASTM D41 primer.
Exterior Research and Design,U.C.d/b/a Trinity)ERD Evaluation Report M10000.03.08-115 for FL10497-RS
Certificate of Authorization H9503 Revision 5:12/14/2015
Prepared by:.Robert Ni'eminen,PE-59166: Appendix 1,Page 8 of 23