HomeMy WebLinkAboutREVISION, CALCS FOR WINDOWS AND SL GL DOORSDATE FILED: REVISION FEE: LOCATION/SITE ADDRESS: 5120 Watersong Way Ft. Pierce PERMIT # 1907-0406 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: Revised energy calc's for windows as requested by inspector CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC046609 ST. LUCIE CO CERT. #: 16222 BUSINESS NAME: JMC Contracting Inc QUALIFIERS NAME: John Cherveny ADDRESS: 601 SE Central Pkwy CITY: Stuart STATE: FI ZIP: 34994 PHONE (DAYTIME): 772-287-0390 FAX: 772-283-0987 OWNERBUILDER INFORMATION: NAME: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: Braden & Braden Architects ADDRESS: 417 SE Coconut Ave CITY: Stuart PHONE (DAYTIME): 772-287-8258 SLCCC: 9123109 Revised 06130117 STATE: Fl r Hsi: ZIP: ZIP: 34996 772-287-8283 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Detached or multiple -family 2. Detached b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2999 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0,312 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.204 14. Heating system: Capacity 34.0 c) Area 7c. 585.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 30.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 2. Masonry (Insulation R-value) 1062. 4.1 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11C. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Address of New Home: City/FL Zip: , FL 4/14/2021 12:40:30 PM EnergyGauge® USA 7.0.00 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HARRIS RESIDENCE Builder Name: HOMES BY JMC Street: Permit Office: ST LUCIE COUNTY City, State, Zip: FL, Permit Number: Y U Owner: BRENT HARRIS Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the boftorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/14/2021 12:40 PM EnergyGaugeeU USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HARRIS RESIDENCE Builder Name: HOMES BY JMC Street: Permit Office: ST LUCIE COUNTY City, State, Zip: , FL, Permit Number: Owner: BRENT HARRIS Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3980.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 3820.00 ft2 b. Concrete Block - Ext Insul, Adjacent R=4.1 160.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2999.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2423.00 112 6. Conditioned floor area above grade (ft2) 2999 b. Knee Wall (Unvented) R=19.0 576.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(585.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 130 a. U-Factor: Sgl, U=0.29 234.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 130 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.35 120.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.19 a. Central Unit 24.0 SEERA6.00 b. Central Unit 24.0 SEER:16.00 c. U-Factor: Sgl, U=0.34 90.00 ft2 SHGC: SHGC=0.20 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 141.00 ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 3.969 ft. Area Weighted Average SHGC: 0,204 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2999.0 sgft.) Insulation Area EF: 0.980 a. Raised Floor R=30.0 2780.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 219.00 ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.195 Total Proposed Modified Loads: 105.45 PASS SS Total Baseline Loads: 117.01 1 hereby certify that the plans and specifications covered by Review of the plans and vTHE S7* this calculation are in compliance with the Florida Energy specifications covered by this �Oa , • _ : �0� Code. calculation indicates compliance with the Florida Energy Code. PREPAR D BY' Before construction is completed ' - DATE: this building will be inspected for compliance with Section 553.908 ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COP WETR� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/14/2021 12:40 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HARRIS RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2999 Lot # Owner Name: BRENT HARRIS Total Stories: 3 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMES BY JMC Rotate Angle: 0 Street: Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: Family Type: Detached FL, New/Existing: New (From Plans) Comment: REVISED ON 4/14/21 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1609 16090 2 AHU 2 1390 13900 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ENTRY 134 1340 No 0 1 Yes Yes Yes 2 ELEV 1ST FLR 25 250 No 0 1 No Yes Yes 3 STORAGE 1ST FL 60 600 No 0 1 Yes Yes Yes 4 STAIRS UP 105 1050 No 0 1 Yes Yes Yes 5 WIC 56 560 No 0 1 Yes Yes Yes 6 HISWIC 56 560 No 0 1 No Yes Yes 7 BEDROOM 2 246 2460 No 0 1 1 Yes Yes Yes 8 HALLWAY 75 750 No 0 1 No Yes Yes 9 DEN 160 1600 No 0 1 Yes Yes Yes 10 BATH 2 54 540 No 0 1 Yes Yes Yes 11 LAUNDRY 54 540 No 0 1 Yes Yes Yes 12 ELEV 3RD FLR 30 300 No 0 1 No Yes Yes 13 MASTER BEDROO 266 2660 No 0 1 1 Yes Yes Yes 14 HER WIC 120 1200 No 0 1 Yes Yes Yes 15 M TOILET 24 240 No 0 1 Yes Yes Yes 16 M BATH 144 1440 No 0 1 Yes Yes Yes 17 GREAT ROOM 576 5760 No 0 1 Yes Yes Yes 18 KITCHEN 283 2830 Yes 0 1 Yes Yes Yes 19 PANTRY 30 300 No 0 1 Yes Yes Yes 20 CLST 3 10 100 No 0 1 Yes Yes Yes 21 STUDIO 172 1720 No 0 1 Yes Yes Yes 4/14/2021 12:40 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT 5UMMAKY UHEGKLI51 KI=PVK I SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 22 BEDROOM 3 195 1950 No 0 1 1 Yes Yes Yes 23 BATH 3 54 540 No 0 1 No Yes Yes 24 HALL 45 450 No 0 1 Yes Yes Yes 25 ELEV. 2ND FLR 25 250 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation ENTRY 20 ft 0 134 f12 ____ 1 0 0 2 Slab -On -Grade Edge Insulation ELEV 1 ST FLR 1 ft 0 25 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation STORAGE 1 ST F 16 ft 0 60 ft2 ____ 1 0 0 4 Raised Floor STAIRS UP ___ ____ 105 ft2 30 1 0 0 5 Raised Floor WIC 2 ___ ____ 56 ft2 30 1 0 0 6 Raised Floor HIS W IC ____ ____ 56 ft2 30 1 0 0 7 Raised Floor BEDROOM 2 ___ ____ 246 ft2 30 1 0 0 8 Raised Floor HALLWAY ___ ____ 75 ft' 30 1 0 0 9 Raised Floor DEN ____ ____ 160 ft2 30 1 0 0 10Raised Floor BATH 2 ___ ____ 54 ft2 30 1 0 0 11 Raised Floor LAUNDRY ___ ____ 54 ft2 30 1 0 0 12Raised Floor ELEV 3RD FLR ___ ____ 30 ft2 30 1 0 0 13Raised Floor MASTER BEDRO ___ ____ 266 ft2 30 1 0 0 14Raised Floor HER WIC -__ ____ 120 ft2 30 1 0 0 15Raised Floor M TOILET ___ ____ 24 ft2 30 1 0 0 16Raised Floor M BATH ___ ___ 144 ft2 30 1 0 0 17Raised Floor GREAT ROOM ____ ___ 576 ft2 30 1 0 0 18Raised Floor KITCHEN ___ ____ 283 ft' 30 1 0 0 19Raised Floor PANTRY ___ ____ 30 ft' 30 1 0 0 20Raised Floor CLST 3 ____ ____ 10 ft2 30 1 0 0 21Raised Floor STUDIO ____ ___ 172 ft2 30 1 0 0 22Raised Floor BEDROOM 3 ___ ____ 195 ft2 30 1 0 0 23Raised Floor BATH 3 ---- --_ 54 ft2 30 1 0 0 24Raised Floor HALL ___ ____ 45 ft2 30 1 0 0 4/14/2021 12:40 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 25Raised Floor ELEV. 2ND FLR -__ _--- 25 ft' 30 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3354 ft2 Oft° Light N 0.3 No 0.9 No 20 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2999 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic(Unvented) ENTRY 20 Blown 134 ft' 0.1 Wood 2 Under Attic (Unvented) ELEV 1ST FLR 20 Blown 25 ft2 0.1 Wood 3 Under Attic (Unvented) STORAGE 1ST F 20 Blown 60 ft' 0.1 Wood 4 Under Attic(Unvented) STAIRS UP 20 Blown 105 ft2 0.1 Wood _ 5 Under Attic (Unvented) WIC 2 20 Blown 56 ft' 0.1 Wood 6 Under Attic(Unvented) HIS WIC 20 Blown 56 ft2 0.1 Wood 7 Under Attic (Unvented) BEDROOM 2 20 Blown 246 ft2 0.1 Wood 8 Under Attic(Unvented) HALLWAY 20 Blown 75 ft2 0.1 Wood 9 Under Attic (Unvented) DEN 20 Blown 160 ft2 0.1 Wood 10 Under Attic (Unvented) BATH 2 20 Blown 54 ft2 0.1 Wood _ 11 Under Attic(Unvented) LAUNDRY 20 Blown 54 ft' 0.1 Wood 12 Under Attic (Unvented) ELEV 3RD FLR 20 Blown 30 ft' 0.1 Wood 13 Under Attic (Unvented) MASTER BEDRO 20 Blown 266 ft' 0.1 Wood 14 Under Attic(Unvented) HER WIC 20 Blown 120 ft2 0.1 Wood 15 Under Attic (Unvented) M TOILET 20 Blown 24 ft2 0.1 Wood 16 Under Attic(Unvented) MBATH 20 Blown 144 ft2 0.1 Wood 17 Knee Wall (Unvented) GREAT ROOM 19 Blown 576 ft2 0.1 Wood 18 Under Attic(Unvented) KITCHEN 20 Blown 283 ft2 0.1 Wood 19 Under Attic (Unvented) PANTRY 20 Blown 30 ft2 0.1 Wood 20 Under Attic (Unvented) CLST 3 20 Blown 10 ft2 0.1 Wood 21 Under Attic (Unvented) STUDIO 20 Blown 172 ft2 0.1 Wood 22 Under Attic (Unvented) BEDROOM 3 20 Blown 195 ft2 0.1 Wood 23 Under Attic (Unvented) BATH 3 20 Blown 54 ft2 0.1 Wood 24 Under Attic (Unvented) HALL 20 Blown 45 ft2 0.1 Wood 25 Under Attic (Unvented) ELEV. 2ND FLR 20 Blown 25 ft2 0.1 Wood 4/14/2021 12:40 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Ext Insul ENTRY 4.1 9 0 10 0 90.0 ft2 0 0 0.3 0 _ 2 W Exterior Concrete Block - Ex[ Insul ENTRY 4.1 11 0 10 0 110.0 ft2 0 0 0.3 0 _ 3 S Garage Concrete Block - Ext Insul ENTRY 4.1 12 0 10 0 120.0 ft2 0 0 0.3 0 _ 4 W Garage Concrete Block - Ext Insul ENTRY 4.1 4 0 10 0 40.0 ft2 0 0 0.3 0 _ 5 N Exterior Concrete Block - Ext InsLSTORAGE 1 4.1 10 0 10 0 100.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block - Ext InsLSTORAGE 1 4.1 6 0 10 0 60.0 112 0 0 0.3 0 _ 7 E Exterior Concrete Block - Ext Insu6TAIRS UP 4.1 15 0 10 0 150.0 ft2 0 0 0.3 0 8 W Exterior Concrete Block - Ext Insul WIC 2 4.1 8 0 10 0 80.0 ft2 0 0 0.3 0 9 S Exterior Concrete Block - Ext Insi6EDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.3 0 _ 10 W Exterior Concrete Block - Ext Insi6EDROOM 2 4.1 18 0 10 0 180.0 ft2 0 0 0.3 0 _ 11 E Exterior Concrete Block - Ext Insul DEN 4.1 11 0 10 0 110.0 ft2 0 0 0.3 0 _ 12 S Exterior Concrete Block - Ext Insul DEN 4.1 14 0 10 0 140.0 112 0 0 0.3 0 _ 13 W Exterior Concrete Block - Ext Insul DEN 4.1 8 0 10 0 80.0 ft2 0 0 0.3 0 _ 14 E Exterior Concrete Block - Ext Insul BATH 2 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 _ 15 E Exterior Concrete Block - Ext InsuILAUNDRY 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 _ 16 N Exterior Concrete Block - Ext InsdMASTER BE 4.1 14 0 10 0 140.0 ft2 0 0 0.3 0 17 W Exterior Concrete Block - Ext InsLIMASTER BE 4.1 19 0 10 0 190.0 ft2 0 0 0.3 0 _ 18 E Exterior Concrete Block - Ext Insul HER WIC 4.1 10 0 10 0 100.0 ft2 0 0 0.3 0 _ 19 E Exterior Concrete Block- Ext InsulM TOILET 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 _ 20 N Exterior Concrete Block - Ext Insul M BATH 4.1 12 0 10 0 120.0 ft2 0 0 0.3 0 _ 21 E Exterior Concrete Block - Ext Insul M BATH 4.1 8 0 10 0 80.0 ft2 0 0 0.3 0 _ 22 W Exterior Concrete Block - Ext Insul M BATH 4.1 9 0 10 0 90.0 ft2 0 0 0.3 0 _ 23 N Exterior Concrete Block - Ext InstOREAT ROO 4.1 28 0 10 0 280.0 ft2 0 0 0.3 0 24 E Exterior Concrete Block - Ext InsGREAT ROO 4.1 25 0 10 0 250.0 ft2 0 0 0.3 0 25 W Exterior Concrete Block - Ext InsOREAT ROO 4.1 25 0 10 0 250.0 ft2 0 0 0.3 0 _ 26 W Exterior Concrete Block - Ext Insul KITCHEN 4.1 9 0 10 0 90.0 ft2 0 0 0.3 0 _ 27 W Exterior Concrete Block - Ext Insul PANTRY 4.1 6 0 10 0 60.0 ft2 0 0 0.3 0 _ 28 W Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.3 0 _ 29 N Exterior Concrete Block - Ext Insul STUDIO 4.1 4 0 10 0 40.0 ft2 0 0 0.3 0 _ 30 E Exterior Concrete Block - Ext Insul STUDIO 4.1 14 0 10 0 140.0 ft2 0 0 0.3 0 _ 31 S Exterior Concrete Block - Ext Insul STUDIO 4.1 15 0 10 0 150.0 ft2 0 0 0.3 0 _ 32 W Exterior Concrete Block - Ext Insul STUDIO 4.1 5 0 10 0 50.0 W 0 0 0.3 0 _ 33 S Exterior Concrete Block - Ext InsLBEDROOM 3 4.1 13 0 10 0 130.0 ft2 0 0 0.3 0 _ 34 W Exterior Concrete Block - Ext Ins01EDROOM 3 4.1 15 0 10 0 150.0 ft2 0 0 0.3 0 35 E Exterior Concrete Block- Ext Insul HALL 4.1 9 0 10 0 90.0 ft2 0 0 0.3 0 4/14/2021 12:40 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 E 7 Vinyl Low-E Single Yes 0.29 0.22 N 30.0 ft' 2 ft 0 in 1 ft 4 in None None _ 2 S 9 Vinyl Low-E Single Yes 0.29 0.22 N 48.0 ft' 6 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 3 W 10 Vinyl Low-E Single Yes 0.29 0.22 N 12.0 fV 2 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 4 E 11 Vinyl Low-E Single Yes 0.31 0.18 N 12.0 fF 2 ft 0 in 1 ft 4 in None None _ 5 S 12 Vinyl Low-E Single Yes 0.31 0.16 N 8.0 ft' 2 ft 0 in 1 ft 4 in None None 6 S 12 Vinyl Low-E Single Yes 0.29 0.2 N 40.0 ft- 2 ft 0 in 1 ft 4 in None None _ 7 E 14 Vinyl Low-E Single Yes 0.31 0.18 N 6.0 ft- 2 ft 0 in 1 ft 4 in None None 8 E 15 Vinyl Low-E Single Yes 0.31 0.18 N 6.0 ft' 2 ft 0 in 1 ft 4 in None None 9 N 16 Vinyl Low-E Single Yes 0.35 0.19 N 48.0 W 8 ft 0 in 1 ft 4 in None None 10 W 17 Vinyl Low-E Single Yes 0.29 0.22 N 12.0 ft- 2 ft 0 in 1 ft 4 in None None 11 E 19 Vinyl Law-E Single Yes 0.31 0.18 N 6.0 ft- 2 ft 0 in 1 ft 4 in None None _ 12 N 20 Vinyl Low-E Single Yes 0.34 0.2 N 45.0 ft- 2 It 0 in 1 ft 4 in Drapes blinds Exterior 5 13 N 23 Vinyl Low-E Single Yes 0.34 0.2 N 45.0 0- 2 ft 0 in 1 ft 4 in None None _ 14 N 23 Vinyl Low-E Single Yes 0.35 0,19 N 72.0 fF 8 It 0 in 1 ft 4 in None None 15 W 25 Vinyl Low-E Single Yes 0.29 0.22 N 36.0 ft- 2 ft 0 in 1 ft 4 in None None 16 W 26 Vinyl Low-E Single Yes 0.29 0.22 N 12.0 ft' 2 It 0 in 1 ft 4 in None None 17 E 30 Vinyl Low-E Single Yes 0.31 0.18 N 15.0 ft- 2 ft 0 in 1 ft 4 in None None 18 S 31 Vinyl Low-E Single Yes 0.29 0.2 N 40.0 ft' 2 ft 0 in 1 ft 4 in None None 19 W 32 Vinyl Low-E Single Yes 0.29 0.22 N 24.0 ft- 4 ft 0 in 1 ft 4 in None None 20 S 33 Vinyl Low-E Single Yes 0.29 0.22 N 48.0 fi 6 ft 0 in 1 ft 4 in None None _ 21 W 34 Vinyl Low-E Single Yes 0.29 0.22 N 12.0 ft' 2 ft 0 in 1 ft 4 in None None 22 S 12 Vinyl Low-E Single Yes 0.29 0.2 N 8.0 ft' 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 672 ft' 672 ft' 16 It 10 ft 4.1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 3498.8 191.96 360.38 .2144 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 17 kBtu/hr 2 sys#2 4/14/2021 12:40 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts _ 1 Central Unit/ Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None STORAGE 1SlORJH2 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / --- Supply---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 130 W Attic 13 ft' Default Leakage Attic (Default) c(Default) c 1 1 2 Attic 6 130 ft2 Attic 13 ft' Default Leakage Attic (Default) c(Default) c 2 2 TEMPERATURES Programablef CFans: xThermostat:`x],JN HeatinDec g Jan Feb Mar Apr AApr ffeiling �X May Jun [ Jul j Aug �Cj ] Sep f[X1] Nov�fX1I OctOct Nov Dec Venting I Jan I 1 Feb l l l X Mar l�l [ Jun I Jul 11 Aug EX� E 1 Sep [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 ft' 0 ft 0.3 FOYER Default(81bs/sq.ft. ft' ft 0.3 UTILITY Default(81bs/scift ft' ft 0.3 GREAT RM Default(8 lbs/sq.ft. ft' ft 0.3 PANTRY Default(8 lbs/sq.ft. W ft 0.3 KITCHEN/DINING Default(8 lbs/sq.ft. ft' ft 0.3 ARRIVAL Default(8 lbs/sq.ft, ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. W ft 0.3 WIC Default(8 lbs/sq.ft. W ft 0.3 ENTRY HALL Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM 3 4/14/2021 12:40 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 CLST 3 Default(B lbs/sq.ft. ft' ft 0.3 DEN Default(8 lbs/sq.ft. ft' ft 0.3 POOL BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft' ft 0.3 HALLWAY Default(8 lbs/sq.ft. ft' ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft' ft 0.3 M BATH Default(8 Ibs/sq.ft. It, ft 0.3 M HALL Default(8 lbs/sq.ft. It, ft 0.3 M WIC Default(8 Ibs/s .ft. ft' ft 0.3 MASTER BEDROO 4/14/2021 12:40 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.