N HVAC Layout Mwic Master Bath Dining IGtchen Bath2 10x6 10x6 11 cfm 8x4 22cfm 4„ 10x6 10x6 29 cfm 4° 82 cfm 101 cf 4 6" 2 Ton ah located in aroc 12" 12x12 4x20 10 x 6 Thr"wall RA 93 cfm 123 cfm 6 6 10x6 10x6 186 cfm 77 cfm 8" 6, 10x6 162 cfm 12x12 B. Thru wall RA Living Rm Master Bedroom Bedroom Enclosed Garage D � APR 1 0 REC'D Job#: R0218054 Service Star Cooling and Heating Scale: 1/9' = TO" Performed by JND for: Page 1 Lalonde Residence RightSuite®Universal 2018 5307 Myrtle Dr 18.0.11 RSU07440 Fort Pierce,FL 34982 2018-Apr-09 12:51:24 ...R0218054-LalondekR0218054c.rup S t Suct sem Summary Job: R0218054 -�- wright5oftm D y Date: 02-07-18 Entire House By: JND Service Star Cooling and Heating Project Information For: Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.17 in H2O 0.17 in H2O Available static pressure 0.33 in H2O 0.33 in H2O Supply/return available pressure 0.253/0.077 in H2O 0.253/0.077 in H2O Lowest friction rate 0.126 in/100ft 0.126 in/100ft Actual air flow 0 cfm 793 cfm Total effective length(TEL) 261 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk Bath2 c 658 0 29 0.185 4.0 OXO VIFx 17.0 120.0 st1 Bedroom c 1722 0 77 0.179 6.0 OXO VIFX 6.3 135.0 st1 Dining c 1850 0 82 0.140 6.0 OXO VIFX 20.9 160.0 st1 Enclosed Garage c 3648 0 162 0.187 8.0 OX 0 VIFX 14.9 120.0 st1 Kitchen c 2262 0 101 0.180 6.0 OXO VIFX 5.7 135.0 st1 Living Rm c 4181 0 186 0.141 8.0 OX 0 VIFX 19.1 160.0 st1 Master Bath c 241 0 11 0.132 4.0 Ox 0 VIFX 25.9 165.0 st1 Master Bedroom c 2762 0 123 0.134 6.0 OX 0 VIFx 23.6 165.0 st1 MWIC c 494 0 22 0.126 4.0 OXO VIFx 30.4 170.0 st1 SupplyD- Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 0 793 0.126 1010 12.0 0 x 0 VinIFIX Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox0 0 793 61.0 0.126 568 16.0 Ox 0 VIFx - wrightsoft- 2018-Apr-09 12:5D:21 Right-Suite®Universal 2018 18.0.11 RSUD7440 Page 1 ACC, ...VAC\aWork File\R0218054-Lalonde\R0218054c.rup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: R0218054 wrightsoft� p p Date: 02-07-18 Entire House By: JND Service Star Cooling and Heating Project Information Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 Cooling Design Conditions Outdoor design DB: 90.0°F Sensible gain: 17819 Btuh Entering coil DB: 77.4°F Outdoor design WB: 78.0°F Latent gain: 4468 Btuh Entering coil WB: 63.8°F Indoor design DB: 75.0°F Total gain: 22286 Btuh Indoor RH: 50% Estimated airflow: 793 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitASHP Manufacturer: Rheem Model: RP1424AJ1NA+RH1T2417STANJA Actual airflow: 793 cfm Sensible capacity: 17374 Btuh 98%of load Latent capacity: 6426 Btuh 144%of load Total capacity: 23800 Btuh 107%of load SHR: 73% Heating Equipment .Design Conditions Outdoor design DB: 42.0°F Heat loss: 14402 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Rheem Model: RP1424AJ1NA+RH1T2417STANJA Actual airflow: 0 cfm Output capacity: 22800 Btuh 158% of load Capacity balance: 30 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 5.0 kW 118% of load Temp. rise: 20 OF Meets all requirements of ACCA Manual S. * wrightsoft- 2018-Apr-09 12:49:55 Al ,„ ,,�,.,� Right-Suite®Universal 2018 18.0.11 RSU07440 Page 1 AC+CA...VAC\aWork File\R0218054-Lalonde\R0218054c.rup Calc=MJ8 Front Door faces: N Project Summary Job: R0218054 Wrlghtsof� , rl�6 Date: 02-07-18 Entire House By: JND Service Star Cooling and Heating �Project Information For: Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 Notes: Load calculation was obtained from an electronic copy of CAD drawing. Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11660 Btuh Structure 13444 Btuh Ducts 1538 Btuh Ducts 4375 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13198 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17819 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3148 Btuh Ducts 1320 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ftz 1176 11A Equipment latent load 4468 Btuh Volume(ft3) 9408 9408 Air changes/hour 0.31 0.16 Equipment Total Load (Sen+Lat) 22286 Btuh Equiv.AVF (cfm) 49 25 Req. total capacity at 0.76 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Rheem Make Rheem Trade Split HP Trade Split HP Model RP1424AJlNA Cond RP1424AJlNA AHRI ref 7489174 Coil RHIT2417STANJA AHRI ref 7489174 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating Input Sensible cooling 18088 Btuh Heating output 22800 Btuh @ 47°F Latent cooling 5712 Btuh Temperature rise 0 OF Total cooling 23800 Btuh Actual air flow 0 cfm Actual air flow 793 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point= 30 OF Backup: Aux Heat Input= 5 kW, Output= 17061 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ad- wr!0ht2F.o4`t- 2018-Apr-09 12:49:55 RightSuite®Universal 2018 18.0.11 RSU07440 Pagel ACCN...VAC\aWork File\R0218054-Lalonde\R0218054c.rup Calc=MJ8 Front Door faces: N ...r, Main File-No.909110888 Lalonde Pa a#14 Building Sketch Borrower/Client Michael&Michelle Lalonde Property Address 5301 M rtle Dr _ City Fort Pierce -- -=- _ County St Lucie State FL Zip Code 34982 Lender GoldWater Bank, N A. 25' 9' ALUMINUM 121 0 ALUMINUM COV/PORCH '- COVERED SCR/PORCH 13' Ac STORAGE N CV W/'D WH T KIT ; UTILITY WALK-IN AREA CLosEr BATH. DIN eu04 BATH .� 1 ALUM N N 1 CAR N LI / (SEE FUNCTIONAL CARPORT BR v B OBSOLESCENCE) ' 38' 12.' 10' 12' En COVERED ENTRY En 26' E �ODIsDVE a D Sketch by Apex Sketch v5 Standard^' APR 1 1U REC Comments: _.......__ ._ _ :.11_ AREA CALCULATIONS SUMMARY1 e t LIVING<AREA BREAKDOWN Y _-- Code Descnptton NetStze Net Totals,;.; < Breakdown i Subtotals r,ni First-;Floor .4 938 00:.. 938 00: First Floor . ,. GAR 1 Car•Ga=age 288.00. 38.0 x 24 .0 912.00 1, Alum Carpoit 240.00. 528 00',_ 2'.0 x 13.0 = = 26.00- - P/P Alum;Gov'Scr/Porch 250.;00- Alum.,Cov/Porch ". _72'.00. Storage Area: 72.00 - _-, Covered_Ent - 130:'00' 524 00 -.- -