ABEL HVAC Layout Mwic Master Bath Dining Kitchen Bath2 10x6 10x6 11 cfm 8 x 4 22 cfm 4 . 10 x 6 10 x 6 29 cfm 4" 82 cfm 101 cf 4 6" 2 Ton ah located in attic 12" 12x12 0 4x20 10 x 6 Th"'wall RA 93 cfm 123cfm 10x6 6" 6" 10 x 6 77 cfm 186 cfm 8" 6 10x6 162 cfm 12x12 8,. Thru wall RA Living Rm / Master Bedroom Bedroom Enclosed Garage E I [ice, -E-P APR 2 RECD I "" IL z CUPY y I Job#: R0218054 g Scale: 10 = 1'0" Performed by JND for: Service Star Cooling and Heating page 1 Lalonde Residence RightSuite@ Universal 2018 5307 Myrtle Dr 18.0.10 RSU07440 Fort Pierce,FL 34982 2018-Mar-29 14:10:08 ...R0218054-Lalonde1R0218054c.rup I AdInk THESE PLAS AivO ALL PROPOSED WORK ARE SUBJECT TO ANC CORRECTIONS - REQUIRED BY FIELD INSPECTORS THAT COPYa BE Nl'd � � @@gg� � PTO n, '66 ai�t ARY'YY❑19L�FERTO , FILE O-APU-1-�Rffi H P-tLL APPLICX- F CODESaA- HVAC Layout IGZhen Mwic Master Bath 10 x 6 10 x 6 80 cfm 177 cfm 6 10x6 8, 10x6 12 cfm 25 cfm 4- 4 10x6 2Ton 80 cfm 10" ah located in attic 6" x 793 cfm 12 x 12 16" Fiala Garage Th`uwall RA 2" Bedroom 10x6 138 cfm 10 x 7 10x6 cfjn 177cfm 2x1 4 8' Thru wall 10 x 6 i 82 cfm Master Bedroom Living Dining Rm� 6" Bath 7-0 ST.LUCIE COUNTY BUILDING DIVISION REVIEWED FORCOMPLIA � REVIEWED BY DATE O - � PLANS AND PER MUST BE KEPT ON B OR NO INSPECTION WI BE MADE Job#: R0218054 Service Star Cooling and Heating Scale: 1/8" = TO" Performed by JND for: Page 1 Lalonde Residence Right-Suite®Universal 2018 5307 Myrtle Dr 18.0.10 RSU07440 Fort Pierce,FL 34982 2018-Feb-23 16:53:06 ...Insurance Company\R0218054b.rup Duct S stem Summa Job: R a -�- wrightSoft. y � Date: 02-07-1807-18 Entire House By: JND Service Star Cooling and Heating Project • • For: Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 LECOPY Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.17 in H2O 0.17 in H2O Available static pressure in H2 p 0 33 O 0.33 in H2O Supply/return available pressure 0.232/0.098 in H2O 0.232/0.098 in H2O Lowest friction rate 0.158 in/100ft 0.158 in/100ft Actual air flow 0 cfm 793 cfm Total effective length (TEL) 209 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mad Ln (ft) Ln (ft) Trunk Bath C 413 0 20 0.159 4.0 OXO VIFX 21.2 125.0 st1 Bedroom C 1668 0 82 0.165 6.0 OXO VIFX 15.8 125.0 st1 Kitchen C 1635 0 80 0.163 6.0 Ox0 VIFX 17.2 125.0 st2 Kitchen-A c 1635 0 80 0.160 6.0 OXO VIFX 24.9 120.0 st2 Living Dining Rm c 3606 0 177 0.172 8.0 OXO VIFX 10.2 125.0 st2 Living Dining Rm-A C 3606 0 177 0.170 8.0 OXO VIFX 11.9 125.0 st1 Master Bath C 246 0 12 0.166 4.0 OxO VIFX 14.9 125.0 st2 Master Bedroom c 2798 0 138 0.158 7.0 OXO VIFX 22.4 125.0 SO Mwic C 505 0 25 0.160 4.0 Ox0 VIFx 20.1 125.0 st2 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 0 418 0.158 532 12.0 0 x 0 VinlFlx st2 Peak AVF 0 375 0.160 688 10.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist . Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mad Trunk rb2 Ox 0 0 793 61.9 0.158 568 16.0 Ox 0 VI Fx C� [E-: u I wlrigtrtsoft, MAR 1 7 RECD 418-Mar-1417:18:38 Right-Suite)Universal 2018 18.0.10 RSU07440 Page 1 ACCA C:IHVAC1aWork File1R0218054-Lalonde1R0218054.rup Calc=MJ8 Front Door faces: N Project Summary Job: R0218054 wri htsoft� rY Date: 02-07-18 9 Entire House By: JND Service Star Cooling and Heating For: Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 FILE Notes: Load calculation was obtained from an electronic copy of CAD drawing. / D- • e • y Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db - 42 -OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9677 Btuh Structure 11912 Btuh Ducts 1397 Btuh Ducts 4199 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 683 Btuh Piping 0 Btuh Equipment load 11074 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 16794 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2936 Btuh Ducts 1187 Btuh Central vent (0 cfm) 0 Btuh Heatingg cooling (none) Area(W 938 938 Equipment latent load 4123 Btuh Volume(ft3) 7504 7504 Air changes/hour 0.31 0.16 Equipment Total Load (Sen+Lat) 20917 Btuh Equiv.AVF(cfm) 39 20 Req. total capacity at 0.73 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Rheem Make Rheem Trade Split HP Trade Split HP Model RP1424AJlNA Cond RP1424AJlNA AHRI ref 7489174 Coil RH1T2417STANJA AHRI ref 7489174 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 17374 Btuh Heating output 22800 Btuh @ 47°F Latent cooling 6426 Btuh Temperature rise 0 OF Total cooling 23800 Btuh Actual air flow 0 cfm Actual air flow 793 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point=26 OF Backup: Aux Heat Input=5 kW, Output= 17061 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft 2018-Feb-23 16:55:21 Right-Suite®Universal 2018 18.0.10 RSU07440 Page 1 ,4CCP. CAHVAC1aWork File\R0218054-Lalonde\R0218054.rup Calc=MJ8 Front Door faces: N Job: R0218054 - - wrightsoft° Manual S Compliance Report Date: 02-07-18 Entire House By: JND Service Star Cooling and Heating Project Information For: Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 Cooling Design Conditions Outdoor design DB: 90.0°F Sensible gain: 16794 Btuh Entering coil DB: 78.2°F Outdoor design WB: 78.0°F Latent gain: 4123 Btuh Entering coil WB: 64.1°F Indoor design DB: 75.0°F Total gain: 20917 Btuh Indoor RH: 50% Estimated airflow: 793 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Rheem Model: RP1424AJ1NA+RH1T2417STANJA Actual airflow: 793 cfm Sensible capacity: 17374 Btuh 103% of load Latent capacity: 6426 Btuh 156% of loadTotal capacity: 23800 Btuh 114% of load SHR: 73% E COPY Heating Equipment Design Conditions Outdoor design DB: 42.0°F Heat loss: 12153 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Rheem Model: RP1424AJ1NA+RH1T2417STANJA Actual airflow: 0 cfm Output capacity: 22800 Btuh 188% of load Capacity balance: 26 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 5.0 kW 140% of load Temp. rise: 20 °F Meets all requirements of ACCA Manual S. * wrightsoft- 2018-Feb-2316:55:21 'Ar. Right-Suite®Universal 2018 18.D.10 RSU07440 Page 1 ACCA C:IHVAC1aWork File1R0218054-Lalonde\R0218054.rup Calc=MJ8 Front Door faces: N -F -wrightsoft• Rlglit=J®Worksheet Job: R0218054 Entire House Date: 02-07-18 By: JND Service Star Cooling and Heating 1 Room name Hall 2 Exposed wall 0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 1.0 x 52.7 ft 5 Room area 52.7 ft' i Ty Construction U-value Or HTM Area (ft') Load Area toad number (Btuh/B;°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 W. 12870sw 0.097 -n. 2.72.: . '2.34 0 0 0 0 128-0sw 0.097 a 2.72 2.34 0 0 0 0 4A5-2ob 0.660 a 15.68 40.74 0 0 0 0 4A5-2ob 0.560 a 15.68 40.74 0 0 0 0 11 II NO 0.350 a 9.80 9.27 0 0 0 0 y/ 128 Osw' 0.097 s i G '4A5.2ob 0.560 , s 15.68 16.16 0 0 D 0 W 12B-Osw 0.097 w 2.72 2.34 0 0 0 0 I--G 4A5-2ob 0.560 w 15.68 38.59 0 0 0 0 L— G 4A5-2obd 0.560 w 15.68 41.55 0 0 0 0 P ::12B-Osw" 0 097 = 272 .1.33 45 45 123 60 C 1613 30ad 0.032 _- 0.90 1.60 53 53 47 84 0 cw; 27.- :0.00 ',;53 0 S � 5 i 6 c)AED excursion -7 Envelope loss/gain 170 138 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal Qines 6 to 13) 170 138 Less external load 0 0 Less transfer 0 0 Redistribution -170 -138 14 Subtotal 0 0 15 Duct loads 14% 35% 01 0 Total room load 0 0 Air required(cfm) 1 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wright.oit^i 1 �-�••�� Right-Suite®Universal 2018 18.0.10 RSU07440 2018-Feb-2316:55:21 Page 5 At& C:IHVAC1aWork File\R0218054-Lalonde\R0218054.rup Calc=MJ8 Front Door faces: N