Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revisions
OFFICE USE ONLY: 'DATE FILED: REVISION FEE: RECEIPT# 1 PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION C py 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982.5652 '� (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: / Q� 5307 Myrtle Drive Fort Pierce, FL 34982 ST.LUCIE COUNk FOR COMPLI -DETAILED DESCRIPTION OF PROJECT REVIEWED BY DATE >� REVISIONS: LANS AND PE On Site Modifications-See attached Manual J,D&S MUST BE KEPT O JON WILL B CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CAC055550 ST.LUCIE CO CERT.#: BUSINESS NAME: Service Star Air Conditioning And Heating, Inc QUALIFIERS NAME: Robert Noeker ADDRESS: 18735 E Colonial Dr#100 CITY: Orlando STATE: FL ZIP: 32820 PHONE(DAYTIME): 407-568-4688 FAX: 407-568-2766 ONVNER/BUILDER INFORMATION: NAW: Michael Lalonde ADDRESS:5307 Myrtle Drive CITY: Fort Pierce STATE: FL ZIp: 34982 PHONE(DAYTIME: 518478-3850 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME): FAX: SLCCC: 9123109 Revised 06130/17 r '.\ N -FILE COPY HVAC Layout �11112'-0" � - Strg 25'-0" Kitchen Mwic Master Bath RA over doot 12x4 Dining 10x6 10x6 10x6 10x6 25 cfm 34 cfm 90 cfm 90 cfm 4" 4 6" 6" era, 24 x 0 8 x 4 Bath2 RA overdoot ah located inattic793 CM 16 cfm 10 x 6 12x4 p 20 x 12 4" 178 cfm 24'-0" 8" 24'-0" M ® 64 cfm 6" Enclosed Garage 10x6 10x6 135 cfm 161 cfm RA overdoos 6° 8" 12x4 Living Rm Master Bedroom Bedroom r 38'-0" 12'-0" ►� r� r+r ?e�` `` Y U� � ➢ i i� Job#: R0218054 Service Star Cooling and Heating Scale: 1/8" = TO" Performed by JND/TMN for: Page 1 Lalonde Residence RightSuite®Universal 2018 5307 Myrtle Dr 18.0.11 RSU07440 Fort Pierce,FL 34982 2018-Apr-13 15:12:38 ...R0218054-Lalonde\R0218054c.rup wrightsoft. Duct System Summary Job: R0218054 Date: 02-07-18104/13/18 Entire House By: JNDITMN Service Star Cooling and Heating Project Information M.V For: Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 FIR K. ."Al 31 -11 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.17 In H2O 0.17 in H2O Available static pressure 0.33 in H2O 0.33 in H2O Supply/return available pressure 0.240 0.090 in H2O 0.240 0.090 in H2O Lowest friction rate 0.147 in/100ft 0.147 in/100ft Actual air flow 0 cfm 793 cfm Total effective length(TEL) 224 ft Supply Branch Detail Table Design Htg Cig Design Diarn H x W Duct Actual Ftg.Eqv Name (13tuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath2 c 352 0 16 0.164 4.0 Ox 0 VIFx 15.9 130.0 stl Bedroom C 1393 0 64 0.171 6.0 OX0 VIFx 14.8 125.0 stl Enclosed Garage C 3877 0 178 0.153 8.0 Ox 0 VIFx 26.5 130.0 stl Kitchen C 1958 0 90 0.170 6.0 Ox 0 VIFx 15.6 125.0 stl Kitchen-A C 1958 0 90 0.189 6.0 ox 0 VIFx 6.9 120.0 stl Living Rm c 3512 0 161 0.178 8.0 ox 0 VIFx 10.0 125.0 stl Master Bath G 752 0 34 0.150 4.0 Ox 0 VIFx 19.5 140.0 st2 Master Bedroom C 2946 0 135 0.149 6.0 Ox 0 VIFx 20.5 140.0 st2 I Mwic I G 536 1 0 1 25 1 0.147 1 4.0 1 OX0 VIFx 1 22.8 1 140.0 1 st2 Supply Trunk Detail Table Trunk Htg Cig Design Veloc Diarn H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk stl Peak AVF 0 793 0.147 476 12.8 12 x 20 VinIFIx st2 Peak AVF 0 194 0.147 247 12.0 0 x 0 VinIFIx st'l Return Branch DetaJi Table Grille Htg CIg TEL Design Veloc; Diarn H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 ox 0 0 793 61.3 0.147 568 16.0 ox 0 VIFx F LE COPY wrightsoft- 201 B-Apr-1 3 15:05:46 Right-Suite®Universal=8 18.0.11 RSUD7440 Page i ACCA ...vAc\awork FilMR0218054-Lalande\R0218054c.rup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: R0218054 - wrightsoft9 Date: 02-07-18/04113118 Entire House By: JND/TMN Service Star Cooling and Heating Project Information For: Lalonde Residence 5307 Myrtle Dr, Fort Pierce, FL 34982 Cooling Equipment Design Conditions Outdoor design DB: 90.0°F Sensible gain: 17284 Btuh Entering coil DB: 77.6°F Outdoor design WB: 78.0°F Latent gain: 4562 Btuh Entering coil WB: 63.9°F Indoor design DB: 75.0°F Total gain: 21847 Btuh Indoor RH: 50% Estimated airflow: 793 cfm Manufacturer's Performance Data at Actual Design Conditions 104 Equipment type: Split ASHP y ��! 4� sr ' Manufacturer:' Rheem Model: RP1424AJ1NA+RH1T2417S ,A + V. r k-, V . l:ee P L.w`' .!�4 r r T a a d Actual airflow: 793 cfm ? � a4 E ° fi. s � f Sensible capacity: 17374 Btuh 101% of load /° Latent capacity: 6426 Btuh 141 of load ' 6 ,h 4 si Total capacity: 23800 Btuh 109%of load SHR: 73% Heating Equipment Design Conditions Outdoor design DB: 42.0°F Heat loss: 14582 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F FI 'L�' E COPY Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Rheem Model: RP1424AJ1NA+RH1T2417STANJA Actual airflow: 0 cfm Output capacity: 22800 Btuh 156%of load Capacity balance: 30 of Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 5.0 kW 117% of load Temp. rise: 20 °F Meets all requirements of ACCA Manual S. - wrightsoft- 2018-Apr-1315:05:19 Right-Suite®Universal 2018 18.0.11 RSU07440 Page 1 ACCA...VAC\.Work File\R0218054-Lalonde\R0218054c.rup Calc=MJ8 Front Door faces: N Job: R0218064 ft wrightso - Project Summary Date: 02-07-18104/13118 Entire House By: JNDrrMN Service Star Cooling and Heating IRA Project Information 1_7 For: Lalonde Residence 1 5307 Myrtle Dr, Fort Pierce, FL 34982 W-1 a Notes: Load calculation was obtained from an electro aidd�4' Des,ign Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 *F Outside db 90 'F Inside db 70 'F Inside db 75 'F Design TD 28 'F Design TD 15 'F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11739 Btuh Structure 12674 Btuh Ducts 1596 Btuh Ducts 4611 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0. Btuh Piping 0 Btuh Equipment load 13335 Btuh Use manufacturer's data y Ratelswing multiplier 1.00 Infiltration Equipment sensible load 17284 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3193 Btuh Ducts 1369 Btuh Central vent(0 cfm) 0 Btuh He tin Cool' (none) a]Area(ft2) 1229 1226 Equipment latent load 4562 Btuh Volume(ft3) 9808 9808 Air changes/hour 0.31 0.16 Equipment Total Load (Sen+Lat) 21847 Btuh Equiv.AVF(cfm) 51 26 Req,total capacity at 0.76 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Rheem Make Rheern Trade Split HP Trade Split HP Model RP1424AJlNA Cond RP1424AJlNA AHRI ref 7489174 Coll RHIT2417STANJA AHRI ref 7489174 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 18088 Btuh Heating output 22800 Btuh @ 47°F Latent cooling 5712 Btuh Temperature rise 0 'F Total cooling 23800 Btuh Actual air flow 0 cfm Actual air flow 793 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.79 Capacity balance point= 30'F Backup: Aux Heat Input= 5 kW, Output= 17061 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fid- '0 Z_ Right-Suite(D Universal 2018 18.0.11 RSU07440 Roe I ACCK...VAC\aWork Fi(e\R0218054-Lalonde\R02180W.rup Cato=MJ8 Front Door faces: N E